MOTOR STARTER के लिए CABLE, MCB, CONTACTOR & OVER LOAD RELAY SIZE SELECTION कैसे करते है?

  Рет қаралды 78,734

SN TECHNICAL

SN TECHNICAL

4 жыл бұрын

In this video we explain how to select cable size,mcb,contactor,and over load relay size to run 3 phase motor
In this video we explain all size selection for run 10 hp motor and explain woth full calculation
For more learning about more about electrical component size selection just watch and learn
How to calculate kwh or electrical bill calculation
• WHAT IS KWH(UNIT)? HOW...
Cable testing with multimeter
• HOW TO TEST CABLE WITH...
Reverse forward starter power wiring connection
• REVERSE FORWARD STARTE...
Manual reverse forward starter with limit switch
• How to make Reverse fo...
Automatic reverse forward starter
• Star Delta starter pow...
Automatic reverse forward motor starter connection
• Automatic reverse forw...
3 phase rccb test on single phase supply practical
• 3 PHASE RCCB मे SINGLE...
3 phase ammeter connection with selector switch
• 3 PHASE AMMETER CONNEC...
8 pin relay testing with multimeter
• 8 PIN RELAY TESTING WI...
How to check ceiling fan common start run with multimeter
• 3 WIRE CEILING FAN COM...
How to make dol starter with relay
• How to make dol starte...
How to check ceiling fan common start run with series lamp
• Video
ammeter connection with current transformer
• 3 PHASE AMMETER CONNEC...
Cooler motor testing with series test lamp
• COOLER MOTOR TESTING W...
Street light timer setting
• STREET LIGHT TIMER SET...
Air compressure power & control wiring practically
• AIR COMPRESSURE के ST...
3 phase cable testing with megger
• HOW TO CHECK CABLE INS...
3 phase motor test with megger
• Induction motor test (...
Dol starter control from different points
• MOTOR CONTROL FROM DIF...
How to make reverse forward motor starter
• How to make Reverse f...
Manual reverse forward starter with limit switch
• How to make Reverse fo...
Automatic reverse forward starter
• Star Delta starter pow...
Automatic reverse forward motor starter connection
• Automatic reverse forw...
Thanks for watching

Пікірлер: 98
@akashlenka3213
@akashlenka3213 4 жыл бұрын
Mera full doubt clear ho gaya Thanks bro
@venkataramanakeetha1560
@venkataramanakeetha1560 2 жыл бұрын
Clean and neat so thankful to you sir
@lijuabraham1401
@lijuabraham1401 4 жыл бұрын
Sir super 🙏🙏🙏🙏❤❤ bahuth acha video
@anilkumaryadav2885
@anilkumaryadav2885 4 жыл бұрын
Achhi jankari diye sir
@jugadproject89
@jugadproject89 2 жыл бұрын
Very nice super sir
@abhijeetparida8911
@abhijeetparida8911 4 жыл бұрын
really helpful topic
@purushottamyadav1932
@purushottamyadav1932 4 жыл бұрын
आज ऐसा विडियो मिला है। जिससे बहुत सारे शंकाऐ साफ हो गई। बहुत-बहुत धन्यवाद श्रीमान जी
@ramadhargautam8631
@ramadhargautam8631 4 жыл бұрын
Very good information sir
@rahulnangare1062
@rahulnangare1062 2 жыл бұрын
Very good information ☺️
@LalSingh-ws2cq
@LalSingh-ws2cq 4 жыл бұрын
Good I am watching this channel
@ness8583
@ness8583 4 жыл бұрын
Bhut acha video h bhai
@sewarammasram2214
@sewarammasram2214 4 жыл бұрын
बहुत अच्छा समझाया है आपने लेकिन थोड़ी स्पीड ज्यादा है मतलब जल्दी जल्दी बोलते हैं । बहुत बहुत धन्यवाद सर जी ।
@yogendrasahu7533
@yogendrasahu7533 3 жыл бұрын
Best video fully understand
@vishalbhosale9985
@vishalbhosale9985 4 жыл бұрын
Nice video. Ty
@deepakjha9504
@deepakjha9504 2 жыл бұрын
Good lucid Information bhaiya. Kaun sa standard apne follow kiya hai is design ke liye?
@VikasKumar-lx5di
@VikasKumar-lx5di 4 жыл бұрын
Very nice video sir 👌
@KamleshKumar-hu4yw
@KamleshKumar-hu4yw 4 жыл бұрын
Usefull vedio sir
@magiclifestar7611
@magiclifestar7611 4 жыл бұрын
Nice work sir
@rizwanraaz4565
@rizwanraaz4565 4 жыл бұрын
Kindly explain about busbar panel for 10hp motor too. Thanx
@nabindratharu4893
@nabindratharu4893 4 жыл бұрын
2hp single phase ka vedio banau sir g....
@azgarelectronicelectrical7756
@azgarelectronicelectrical7756 3 жыл бұрын
Shukriya bhai sahab
@manjulakarunathilaka7949
@manjulakarunathilaka7949 3 ай бұрын
Thanks brother ❤ 🙏
@ayushmanpadhy3497
@ayushmanpadhy3497 4 жыл бұрын
Nice👌👌
@mohanji5530
@mohanji5530 4 жыл бұрын
Very useful video thanks sir
@prabhashrai3447
@prabhashrai3447 4 жыл бұрын
Sir very good
@lingaiahyellewar3617
@lingaiahyellewar3617 4 жыл бұрын
Very nice video
@anujpanchal8926
@anujpanchal8926 4 жыл бұрын
Bahut dino baad pasndida video bnai
@SNTECHNICAL
@SNTECHNICAL 4 жыл бұрын
Thanks
@anujpanchal8926
@anujpanchal8926 4 жыл бұрын
@@SNTECHNICAL 😀😁😀😀🙏🙏💕💕
@anujpanchal8926
@anujpanchal8926 4 жыл бұрын
Apna whatsapp no. Do
@mdferozali389
@mdferozali389 4 жыл бұрын
Hi sn technical ,12hp k liye konsa capacitor lagana hoga, 0.9 power factor
@karthicknilan6760
@karthicknilan6760 3 жыл бұрын
Wow jie, u r genius!!!!., all vedios fantastic🤘😝🤘...
@SNTECHNICAL
@SNTECHNICAL 3 жыл бұрын
Thanks
@md.faridullah6137
@md.faridullah6137 3 жыл бұрын
@@SNTECHNICAL Thanks for your nice video. Brother, i watch another video from Electrical dost ( a youtuber). He mention there, the size of mcb = FLC+ 50%×FLC, Main contactor and Delta contactor rating= FLC×58%, and Star contactor size= FLC×33%. Please reply, how is it possible. Thanks.
@RAHULSingh-dj8oy
@RAHULSingh-dj8oy 2 жыл бұрын
Sir poori cable size btayiye
@RAHULSingh-dj8oy
@RAHULSingh-dj8oy 2 жыл бұрын
Ki 35 sq mm se lekker 300 sq tk amp Ka farmula
@RAHULSingh-dj8oy
@RAHULSingh-dj8oy 2 жыл бұрын
Please sir help me
@ramadhargautam8631
@ramadhargautam8631 4 жыл бұрын
Sir PLC ke upar video banaiye
@starcodeengineeringsolutio9532
@starcodeengineeringsolutio9532 4 жыл бұрын
Is it only for DOL starters?
@rehmatamin3217
@rehmatamin3217 Жыл бұрын
Very good
@SNTECHNICAL
@SNTECHNICAL Жыл бұрын
Thanks
@panchananmukherjee7091
@panchananmukherjee7091 3 жыл бұрын
Good.idya
@SNTECHNICAL
@SNTECHNICAL 3 жыл бұрын
Thanks
@naomsi9550
@naomsi9550 2 жыл бұрын
Sir, single phase 1HP motor ke liye mcb, wire size bataeye...
@sudeepsingh6912
@sudeepsingh6912 4 жыл бұрын
Thanks
@sukhrajsinghkoura1857
@sukhrajsinghkoura1857 4 жыл бұрын
Cnc machine ke Electricals component ke upper video banye sir
@MN-be7sx
@MN-be7sx 4 жыл бұрын
NOTO (normally open-timed open) and NCTC (normally closed- timed closed) timers par video banay please
@viswanathaniyer2372
@viswanathaniyer2372 4 жыл бұрын
good video
@gulfamshaikh8440
@gulfamshaikh8440 3 жыл бұрын
Thanks sir
@swapnilwaghmare4197
@swapnilwaghmare4197 3 жыл бұрын
👍
@viswanathaniyer2372
@viswanathaniyer2372 4 жыл бұрын
nice
@syamchandu1594
@syamchandu1594 4 жыл бұрын
Super video
@SNTECHNICAL
@SNTECHNICAL 4 жыл бұрын
Thanks
@jeetendrakumar3704
@jeetendrakumar3704 Жыл бұрын
Aap kisi ka 2 HP se lekar 12 Tak single fez aur 3 fez mein MCB conductor overload relay or cable uska ek video banai hai aur usko ek PDF file banakar download kar dijiyega taki ham logon PDF download karke kabhi bhi kaun sa motor ke liye Sahi chun sakte hain
@mohanji5530
@mohanji5530 4 жыл бұрын
Yhe ju cable current batya hai yhe kitni length per 6amp lye sakta hai
@mohanji5530
@mohanji5530 4 жыл бұрын
Sir cable size dol motor k lye hai
@sushilkindo1988
@sushilkindo1988 4 жыл бұрын
Plzz sir zss, pull cord, bss contactor emergency switch control diagram chahiye
@sujoydas5151
@sujoydas5151 4 жыл бұрын
0.5 HP, 0.37kw , 1phase kirloskar chotu pump keliye konsa MCB kharidna chahiye?
@sangameswararaonetula1989
@sangameswararaonetula1989 3 жыл бұрын
Star&delta stator se two cables motor ka pas ayega,that cables how to select R Y B & Y B R. AND Motor se 6 wires ayega, that wires how to select R Y B & Y B R. PLEASE EXPLAIN SIR
@matheen8
@matheen8 4 жыл бұрын
Sir apka video par sound problem hae, dubara upload kijiye , hum dusra channel k video dekhe tey 🔊 speaker hamara theek h , laikin video ka sound thik se nahi aa Raha h aur volume bhi low hae.. muje sunna h yeh video
@chandraprasadchapagai1075
@chandraprasadchapagai1075 3 жыл бұрын
Sir motor starting current motor ka FLC ×3 hota ha na
@kanchanpatil9214
@kanchanpatil9214 2 жыл бұрын
2.5 sqmm copper wire 1 phase ke liye...Yane RYB each 2.5 sq mm...Aise hai kya
@ismailsiddiqui8556
@ismailsiddiqui8556 4 жыл бұрын
ELCB ka bhi batao
@satyendrarajput5014
@satyendrarajput5014 3 жыл бұрын
Sir yadi 10 hp ki motor ko ham, star delta starter par lagayenge tab star contactor k size aur main & delta contactor k size kya hoga
@maheshmaurya5738
@maheshmaurya5738 4 жыл бұрын
Agar 1 min main 6 se 8 baar on off karna ho motor ko to kitne amp ka o/l relay contactor aur mcb lagana hoga
@muhammadsaleemmuhammadhani411
@muhammadsaleemmuhammadhani411 4 жыл бұрын
Sir ap nay ye to btaya hi nae k kitni length pay 6 amp lay sktay hayn. Ye na ho k 6 amp k hisab say cable ki length ziada kr li jay to cable gram ho ya jal jay.
@Ravikumar-ol8wk
@Ravikumar-ol8wk 2 жыл бұрын
In contactor calculation how you take 1.5 please explain sir
@KP-ub1ms
@KP-ub1ms 3 жыл бұрын
Motor have high starting current. Because of that we should use starter. And starting curent will be 6 times greater than full load curnt. Then i dont knw how you are connecting 2.5 cable for 10hp.
@niharranjanprusty9899
@niharranjanprusty9899 3 жыл бұрын
170 hp ke batyiye sir ?
@shankarjadhav3106
@shankarjadhav3106 4 жыл бұрын
Sir contactor flc ke 58% lagana chahiye to aapne 50% kaise lagaya or MCB Selection ki 1.5 kaise aaya plz clear kijiye jara
@muhammadsaleemmuhammadhani411
@muhammadsaleemmuhammadhani411 4 жыл бұрын
Ye btayn k 50 meter lenght pay amp kitnay lay sktayhayn or 100 amp pay kitnay amp lay sktay hayn. Ta k cable ki length ziada honay ki wja say koi msla na ho.
@satishkasote2537
@satishkasote2537 2 жыл бұрын
sir please explain safety factor thumb rule not imp, extact annalyasis is imp
@TUFAN_GAMING_44
@TUFAN_GAMING_44 4 жыл бұрын
M p c p Kon si motar me yuj kar sak te he
@kshitishsingha4359
@kshitishsingha4359 3 жыл бұрын
300 mitar dur me,kitne mm ka cable lagaga,3hp ka mitar.
@pkumarray4899
@pkumarray4899 2 жыл бұрын
Control for MCB ??
@shakirirfani5579
@shakirirfani5579 4 жыл бұрын
Are You Engineer or Technician? your steps for sizing the cable , CB and contactors are wrong. You are following non standard methods.
@mirtayyab6718
@mirtayyab6718 3 жыл бұрын
Some confusion about selection of mcb and contector. Motor having high current in starting. I have some miss understanding . where you multiply 1.5 with full load current . Please 🙏 clear my this miss understanding. I am 80% understand . Your video also very helpful for me.
@jeetendrakumar3704
@jeetendrakumar3704 Жыл бұрын
Iska shortcut Tarika kya hai
@mustafeezalam8936
@mustafeezalam8936 3 жыл бұрын
Assalam alekum sir, sir 30 hp pe kitne ka contactor overloud lagaye
@deepakjha9504
@deepakjha9504 2 жыл бұрын
Ram Ram bhaiya.
@jaikisaanelectricintali4770
@jaikisaanelectricintali4770 4 жыл бұрын
Sir mere 5hpmoter hai or3.7klw Me or us 11mpr moter me diya huaa hai or 13se21ki रीले है और मैने जो आप ने फार्मूला बताया इसके हिसाब से 9mpr arha haior relet 6se10aa rahi hai ab mujhe kush samaj nhi aarha hi ki konsa sahi hai sr ap mujhe batay9925243939
@mokavamsi9650
@mokavamsi9650 4 жыл бұрын
I have small doubt witha that contactor selection We need to select the contactor with 50% extra but why your calculating 13.837*1.5 ????
@Vivek-yn7jb
@Vivek-yn7jb Жыл бұрын
if we multiply something with 1, we get its 100% or original value. eg. 20 * 1 = 20, if we multiply something with .5 we get only 50% value eg. 20 x 0.5 = 10, Hence, if we multiply something with 1.5 we get its (original value + 50% of original value) 20 x 1.5 = 30 as you can see here 50% of 20 i.e. 10 is added to its original value (20 + 10 = 30). i dont know how i explained.. still i tried
@NandKishor-uc3ui
@NandKishor-uc3ui 4 жыл бұрын
3pole ki MCB 25A ki aati h kya
@RC-fn3nh
@RC-fn3nh 3 жыл бұрын
Haa
@NandKishor-uc3ui
@NandKishor-uc3ui 4 жыл бұрын
Or sir contacter to FLCka 58% Ka lagana Chahiye aap 50% Ka bta rhe ho
@divsirider6803
@divsirider6803 4 жыл бұрын
7.5 hp ka
@haldeeppatle9637
@haldeeppatle9637 3 жыл бұрын
40 hp motor ke liye realy size bataiye
@sandychoudhari7106
@sandychoudhari7106 3 жыл бұрын
kw 37 FLC 66 CONTACTOR DOL 70 STAR DELTA 40(STAR) 70 (MAIN & DELTA) OLR DOL 57 TO 70 S/D 32 TO 50 BACKUP FUSE 80 CABLE 35 AL 25 CU
@praviningole9196
@praviningole9196 Жыл бұрын
1.5 कैसे आया....
@pkumarray4899
@pkumarray4899 2 жыл бұрын
Contactor selection samjh nahi sir clear nahi hua
@sikandargupta9148
@sikandargupta9148 4 жыл бұрын
Sir motor ka starting current high hota hai Plz Your size selection is wrong Really wrong methode
@NandKishor-uc3ui
@NandKishor-uc3ui 4 жыл бұрын
Sir MCB isme aapne 20A ki bataai h formule ke hisaab se to 25A ki hame lagani Chahiye ,single MCB me 3phase ki 3wire kese lagayenge sir
@noushadali5496
@noushadali5496 4 жыл бұрын
Sir aapka number kya hai
@bepositive1593
@bepositive1593 3 жыл бұрын
Arre sir Ye 50 % and ×1.5 samaz me nahi aaya
@ranjithp6087
@ranjithp6087 3 жыл бұрын
Wrong method sir,please use coordination chart
DO YOU HAVE FRIENDS LIKE THIS?
00:17
dednahype
Рет қаралды 58 МЛН
MEGA BOXES ARE BACK!!!
08:53
Brawl Stars
Рет қаралды 35 МЛН
1 or 2?🐄
00:12
Kan Andrey
Рет қаралды 37 МЛН
Why Star Delta Starter used in Motor
14:25
Deepakkumar Yadav
Рет қаралды 693 М.
Motor Winding Calculation Formula |  Perfect Engineer
9:30
Perfect Engineer
Рет қаралды 498 М.
DO YOU HAVE FRIENDS LIKE THIS?
00:17
dednahype
Рет қаралды 58 МЛН