Hello Sir, I would love to ask you, where did you get the 0.5 and what do you mean by increment. Much appreciated!
@satou79938 ай бұрын
Hello Sir, I am having trouble with my file inputting the moving loads, I would love to ask for your help
@satou79938 ай бұрын
I am getting 5 errors sir, can you please explain why sir
@arnoldatotaanАй бұрын
Sir how do you remove the 10 warning, or is it from the range??
@BeingCivilАй бұрын
as I started the moving load from outside the beam that's why the warning. you can ignore that.
@ehabshawi66662 жыл бұрын
you're the best
@AhliSunnahRasulullahSAW4 жыл бұрын
Hi, can you please use Staad Pro Connect Edition for your future video?
@sibhichelvane69184 жыл бұрын
Clear explanation 👍
@BeingCivil4 жыл бұрын
Thank you 😊
@nithishnayaka.y.b73682 жыл бұрын
How to apply in curved span?please let me know
@AshishSingh-l3x Жыл бұрын
I want only one vehicle load, the vehicle length is 75m with wheels on 1m intervals and its moving on two inclined beams of 150m with a slope of 1:20. can you help me
@raviprasadvoletiBR16L6 ай бұрын
How to generate these moving loads using 'open staad' function?
@shashankshashi32034 жыл бұрын
Hello sir please make a video on designing of suspension bridge using staad pro
@basimalbayati6603 жыл бұрын
Dear please can we do combination for the moving load and dead load ,kind help please
@BeingCivil3 жыл бұрын
@ 02:45 Add Dead Load case No in predefined load case to be added.
@basimalbayati6603 жыл бұрын
@@BeingCivil Thanks so much for your kind reply, but unfortunately combination not performed, I don't know why program not perform combination between moving load and other liads, please did you tried such a case, best regards
@BeingCivil3 жыл бұрын
yes I have tried. You can combine any one primary load case to moving load cases. go to staad input file. write ADD LOAD 1 at the end of load generation line. eg. LOAD GENERATION 500 ADD LOAD 1 (where load case 1 is Dead Load)
@basimalbayati6603 жыл бұрын
@@BeingCivil Dear sorry for disturbing your time, thanks so much, I will try and inform you, kindly send me your WhatsApp number, to communicate with you, best regards
@BeingCivil3 жыл бұрын
send messege to my facebook page. facebook.com/beingcivilchannel
@mudavathgopalnaik65526 ай бұрын
Hlo Sir, there is no Visible the loads to move How to see the loads.I can try number of times.
@ianandrewverallo91003 жыл бұрын
how about for inclined surface??
@BeingCivil3 жыл бұрын
It is till not possible in staad..
@amirhamzanadeemshaikh77403 жыл бұрын
I'm getting error (cannot create load generation command) can you sir please explain why ? I applied same procedure
@BeingCivil3 жыл бұрын
please send the file beingcivilchannel@gmail.com
@hasiburrashid19663 жыл бұрын
I'm getting this errors **ERROR- Number of Primary Cases exceeds value entered please somebody help me
@BeingCivil3 жыл бұрын
send the input file beingcivilchannel@gmail.com
@hasiburrashid19663 жыл бұрын
@@BeingCivilalready solved... but thanks for reacting... I'm still sending the file.. I'm a beginner. so, please check it
@PRAVEENCHARY773 жыл бұрын
WHY I ADDED 4 FOR 25+4? WHY 4?
@BeingCivil3 жыл бұрын
the length of the vehicle 4m. And length of the bridge is 25 m. The total distance covered by the vehicle to fully cross the bridge = bridge length + vehicle length.= (25+4) m