Your videos are very informative and thorough. Well Done!!! Question? I am trying to replace an S5 Rack of IP246 Positioning modules, I want to use an S7-1500 -1PN with TM2 Posinput modules and analog output modules (Drive Analog Setpoints) to control positioning axes with an SSI encoder feedback. Would that be the most efficient way to go?
@electricalautomation Жыл бұрын
If you migrate your system from S5->STEP7->TIA Portal, then you could use the way you wrote. using TM+SSI encoder and analog out can build up a position closed loop control in S7-1500 and basically your migrated program will have a very minimum change. Another way is that using a servo motor and servo drive and using the 2nd encoder channel from the servo drive (e.g. S120 DRIVE-CLiQ module) for measuring your load side position feedback. Is this application come from Iron and Steel RH air O2 gun application?
@PatrickCatalini Жыл бұрын
@@electricalautomation No We are using it for automatic Size format change in the medical film industry. The IP246 module already has most criteria defined I imagine I can use things like incremental speed, software limits, Forward and Reverse Accel /Decel, etc. I am trying to upgrade incrementally so I am thinking of using FDL(open Comm) to communicate between the S5-135U and S7-1500 to transfer target values and other data.
@housamfraunhofer44732 жыл бұрын
ich habe Siemens S120 , power module 27A,600vdc, and Double motor Module 600 vdc , 3Ac 400v 3A: is it suitable to connect with motor 400vac , 6,7A ?
@electricalautomation2 жыл бұрын
not recommended
@koffikoudjra23622 жыл бұрын
Hi thank you for sharing this with us, may you help me with the "sizer, TIA Selection Tool Online/Offline" links, please ?
@electricalautomation2 жыл бұрын
Please find the link for TIA selection tool new.siemens.com/global/en/products/automation/topic-areas/tia/tia-selection-tool.html
@koffikoudjra23622 жыл бұрын
Thank you very much!
@tznalcn3 жыл бұрын
Isnt tia portal basic enough for s7 1200 plcs with servo drive? For 1 axis robots for example. Great videos btw
@electricalautomation3 жыл бұрын
Yes, S7-1214 or higher can support 4 axis (single axis) control. You can use stepper motors or Siemens SINAMICS S210 servo motor as drive.
@tznalcn3 жыл бұрын
@@electricalautomation Is it not possible for example with 1211C DC/DC/DC + V90 + Siemens Servo? If not how could we make it happen? Maybe with ET200? Thanks for the answer
@electricalautomation3 жыл бұрын
@@tznalcn Yes, it is possible. V90 is a good choice. some area cannot sale or buy SINAMIC V90. If you can buy V90, it is cost effective servo system, it also support profinet with s7-1200.
@tznalcn3 жыл бұрын
@@electricalautomation Hey thanks for the information. By the way as I said before great videos. If you are looking for a topic for videos, TIA Selection Tool examples for motion control would be a great choice! Have a nice day!
@gr.imadeddine3243 жыл бұрын
Intresting topic, great video, thanks for sharing !
@electricalautomation3 жыл бұрын
Glad you enjoyed it! Thanks watching!
@siphongxongo85893 жыл бұрын
My King in Motion Control Salute....!!!!!
@electricalautomation3 жыл бұрын
Thanks Bro.
@rahulravi44243 жыл бұрын
I would suggest you to have another Playlist relating SIMIT....it doen't have good resource except the manuals from siemens
@electricalautomation3 жыл бұрын
Thanks for the tip!
@braincrackz3 жыл бұрын
Hello can you share about alarm trigger and handling in siemens s7 300 cpus. If thats okay for you. Thanks
@electricalautomation3 жыл бұрын
Hello, do you mean using Siemens HMI to show the alarm, and the PLC is S7-300? It would be coming month but not recent. I am working on the motion control and communication series these months. Thanks for watching!
@braincrackz3 жыл бұрын
@@electricalautomation not really in the HMI because i am not that yet but the logic i made in DBs can be use in HMI for future use. I only focus on the logic i made a logic for alarm trigger using bools and the problem is i want to make a reset that is in MOVE because i cannot afford to use so TONS of Reset Bit. Using 300 cpu. The idea is splicing the word command into bit in 300 its not possible.anyhow i love watching your videos its more advance
@electricalautomation3 жыл бұрын
I roughly see what you talked about. From my programming style, using the bits from a word from individual alarm, then compare this "word=0" for alarm summary.
@fernandocadena_3 жыл бұрын
Great video!
@electricalautomation3 жыл бұрын
Thanks for watching!
@ahmedatef55632 жыл бұрын
Amazing topics
@electricalautomation2 жыл бұрын
Glad you like them! Thanks!
@alialshammary71889 ай бұрын
thanks for sharing
@BallAndBeam3 жыл бұрын
Great video. Thanks.
@electricalautomation3 жыл бұрын
Thanks watching, welcome!
@tarik.b14003 жыл бұрын
wonderfull job thank you
@electricalautomation3 жыл бұрын
Thanks! This is one of the play lists I am proud of. thanks for watching!
@industrialautomationkotttu88413 жыл бұрын
Keep going
@electricalautomation3 жыл бұрын
Thanks! will do! I am working on some videos about DC Motor positioning control by using S7-1200. They will be launched soon.
@Suppy-m7r20 күн бұрын
❤❤
@sotanluy2240 Жыл бұрын
thanks your so much, video very interesting :>.
@electricalautomation Жыл бұрын
Glad you liked it!
@abujafor79153 жыл бұрын
Thanks
@electricalautomation3 жыл бұрын
Welcome
@kalegamingtv220010 ай бұрын
from this video, i know, i bought wrong device for synchronize position
@electricalautomation10 ай бұрын
Hopefully the video could be helpful. Would you pls let me know which drive and PLC you bought, and which kind of application you want to do