MS03b. [Siemens Motion Control] TIA Portal Technology Object (TO) Configuration [4/10]

  Рет қаралды 25,985

Electrical Automation Hands-On

Electrical Automation Hands-On

Күн бұрын

Пікірлер: 26
@selimalan8145
@selimalan8145 3 жыл бұрын
Very useful channel. Thank you for being such a channel Greetings from Turkey
@electricalautomation
@electricalautomation 3 жыл бұрын
Thanks Buddy, Welcome!
@hamzajmili92
@hamzajmili92 4 жыл бұрын
Thank you for this effort
@electricalautomation
@electricalautomation 4 жыл бұрын
Thanks! Welcome to my channel!
@maza6357
@maza6357 3 жыл бұрын
Thank you for great videos
@electricalautomation
@electricalautomation 3 жыл бұрын
My pleasure! Thanks! I am working on the encoder/high pulses counter of S71200. Those videos are coming soon!
@2tan90
@2tan90 2 жыл бұрын
thank you
@electricalautomation
@electricalautomation 2 жыл бұрын
Welcome! Enjoy!
@TheGreen18
@TheGreen18 3 жыл бұрын
Great Videos Is it possible to Axis that is not from Siemens with the TO? For example Beckhoff?
@electricalautomation
@electricalautomation 3 жыл бұрын
99% the Motion control and the servo drive will be the same brand. The key reason is the communication fieldbus protocol as well as the telegram. If you do have to cross the brand, most common way is to use analog output to control the drive speed and read the encoder use the encoder module.
@marcshiftsolve2947
@marcshiftsolve2947 Жыл бұрын
Is it possible to use s7-1200 cpu instead of s7-1500 cpu's? and as well as to use stepper motor rather than servo motor?
@electricalautomation
@electricalautomation Жыл бұрын
You can view the video, it is using the DC motor, but the idea is the similar MS04a. Setup Positioning Axis via Analog Output, DC Motor, and Encoder kzbin.info/www/bejne/hZWXlKSggtinarM MS04b. Program DC Motor Positioning Control via S7-1200 and TIA Portal kzbin.info/www/bejne/jX-5k5qfa5x7nLM
@elnursucayev6625
@elnursucayev6625 2 жыл бұрын
Thank you. very useful lessons. Please show how you can instal all tia portal version on one PC
@electricalautomation
@electricalautomation 2 жыл бұрын
They can be installed together. You'd better install from the lower version V12 to V17 higher version one by one. It is not recommended to install multiple versions of WinCC Professional in one system. Regular Step7 and WinCC advanced should be no issue.
@elnursucayev6625
@elnursucayev6625 2 жыл бұрын
@@electricalautomation Thank you very much
@richardbanda2817
@richardbanda2817 Жыл бұрын
Great explanation and that you. Would you perhaps have a video of setting up two synchronous axes?. If so, may you kindly direct me to that please.
@electricalautomation
@electricalautomation Жыл бұрын
Hope this video would be helpful kzbin.info/www/bejne/nprIZWmPmZhqq6s
@sedatcemkzltoprak735
@sedatcemkzltoprak735 Ай бұрын
hello, on my program ı cant see axis type / Virtual axis what should ı do ? and without this how ı can control the motor? best regards,
@electricalautomation
@electricalautomation Ай бұрын
Are you using Siemens S7-1500? I guess you are using S7-1200.
@sedatcemkzltoprak735
@sedatcemkzltoprak735 Ай бұрын
@electricalautomation no i was using s7 1500, but I guess i have a some installation error that's why I delete all program and download again now is working.
@michalkall9206
@michalkall9206 Жыл бұрын
Hello, I cant see in my TIA portal option for Virtual Axis, u know where can be problem?
@electricalautomation
@electricalautomation Жыл бұрын
Are you using S7-1500 PLC? Which revision of TIA Portal are you using? I assume you are using S7-1200 PLC or old revision of TIA, they don't support virtual axis.
@EngOmar-kz9qv
@EngOmar-kz9qv 3 жыл бұрын
Thank you very much for your effort . in simotion scout i was using _LineModule_Control function block to enable 36KW SLM infeed but now i am using TIA PORTAL V13 and i don't found this function block . Please how can i find and using this function block ? . Regards
@electricalautomation
@electricalautomation 3 жыл бұрын
Simotion is different system comparing with T-CPU or S7-1500T. In TIA Portal, power up a Axis need to use "MC_Power"
@EngOmar-kz9qv
@EngOmar-kz9qv 3 жыл бұрын
@@electricalautomation if i want to enable 36KW smart line infeed, also i have to use MC_Power ?
@electricalautomation
@electricalautomation 3 жыл бұрын
@@EngOmar-kz9qv No, sorry, MC_Power is used to power up axis. For the Smart Line Infeed enable, maybe search "xx Infeed xx" FB, the "Linemodule" may be changed to "infeed"
MS03a. [Siemens Motion Control] TIA Portal Single Axis Control - Project Introduction [3/10]
4:38
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
MS02. [Siemens Motion Control] 9 Questions About Siemens Motion Control [2/10]
32:08
Electrical Automation Hands-On
Рет қаралды 23 М.
MS06F-1. [Siemens S210 #06-1] Positioning TO Technology Object in TIA Portal - Configuration
33:36
Motion Control has never been so easy
10:41
Siemens Knowledge Hub
Рет қаралды 33 М.
TIA Portal: UDT's (User Defined Types) - Part 1
16:27
Hegamurl
Рет қаралды 47 М.