Very useful channel. Thank you for being such a channel Greetings from Turkey
@electricalautomation3 жыл бұрын
Thanks Buddy, Welcome!
@hamzajmili924 жыл бұрын
Thank you for this effort
@electricalautomation4 жыл бұрын
Thanks! Welcome to my channel!
@maza63573 жыл бұрын
Thank you for great videos
@electricalautomation3 жыл бұрын
My pleasure! Thanks! I am working on the encoder/high pulses counter of S71200. Those videos are coming soon!
@2tan902 жыл бұрын
thank you
@electricalautomation2 жыл бұрын
Welcome! Enjoy!
@TheGreen183 жыл бұрын
Great Videos Is it possible to Axis that is not from Siemens with the TO? For example Beckhoff?
@electricalautomation3 жыл бұрын
99% the Motion control and the servo drive will be the same brand. The key reason is the communication fieldbus protocol as well as the telegram. If you do have to cross the brand, most common way is to use analog output to control the drive speed and read the encoder use the encoder module.
@marcshiftsolve2947 Жыл бұрын
Is it possible to use s7-1200 cpu instead of s7-1500 cpu's? and as well as to use stepper motor rather than servo motor?
@electricalautomation Жыл бұрын
You can view the video, it is using the DC motor, but the idea is the similar MS04a. Setup Positioning Axis via Analog Output, DC Motor, and Encoder kzbin.info/www/bejne/hZWXlKSggtinarM MS04b. Program DC Motor Positioning Control via S7-1200 and TIA Portal kzbin.info/www/bejne/jX-5k5qfa5x7nLM
@elnursucayev66252 жыл бұрын
Thank you. very useful lessons. Please show how you can instal all tia portal version on one PC
@electricalautomation2 жыл бұрын
They can be installed together. You'd better install from the lower version V12 to V17 higher version one by one. It is not recommended to install multiple versions of WinCC Professional in one system. Regular Step7 and WinCC advanced should be no issue.
@elnursucayev66252 жыл бұрын
@@electricalautomation Thank you very much
@richardbanda2817 Жыл бұрын
Great explanation and that you. Would you perhaps have a video of setting up two synchronous axes?. If so, may you kindly direct me to that please.
@electricalautomation Жыл бұрын
Hope this video would be helpful kzbin.info/www/bejne/nprIZWmPmZhqq6s
@sedatcemkzltoprak735Ай бұрын
hello, on my program ı cant see axis type / Virtual axis what should ı do ? and without this how ı can control the motor? best regards,
@electricalautomationАй бұрын
Are you using Siemens S7-1500? I guess you are using S7-1200.
@sedatcemkzltoprak735Ай бұрын
@electricalautomation no i was using s7 1500, but I guess i have a some installation error that's why I delete all program and download again now is working.
@michalkall9206 Жыл бұрын
Hello, I cant see in my TIA portal option for Virtual Axis, u know where can be problem?
@electricalautomation Жыл бұрын
Are you using S7-1500 PLC? Which revision of TIA Portal are you using? I assume you are using S7-1200 PLC or old revision of TIA, they don't support virtual axis.
@EngOmar-kz9qv3 жыл бұрын
Thank you very much for your effort . in simotion scout i was using _LineModule_Control function block to enable 36KW SLM infeed but now i am using TIA PORTAL V13 and i don't found this function block . Please how can i find and using this function block ? . Regards
@electricalautomation3 жыл бұрын
Simotion is different system comparing with T-CPU or S7-1500T. In TIA Portal, power up a Axis need to use "MC_Power"
@EngOmar-kz9qv3 жыл бұрын
@@electricalautomation if i want to enable 36KW smart line infeed, also i have to use MC_Power ?
@electricalautomation3 жыл бұрын
@@EngOmar-kz9qv No, sorry, MC_Power is used to power up axis. For the Smart Line Infeed enable, maybe search "xx Infeed xx" FB, the "Linemodule" may be changed to "infeed"