Multiple Problems on A No Cooling Call!

  Рет қаралды 19,506

HVAC GUY

HVAC GUY

Күн бұрын

In this video I visit a customer who had no cooling! #hvacguy #hvaclife #hvactrainingvideos #hvac #airconditioner #hvactechnician #hvactroubleshooting #furnace #heatpump #hvacinstall #capacitor #runcapbandit #skilledtrades #bluecollarpride
Merch Store : hvac-guy-2.cre...
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Makita Wet/Dry Vac: amzn.to/3VVHpsz
Veto OT-LC: amzn.to/3wSK1Nj
Appion AV760: amzn.to/3OkrwHC
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Bluetooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Пікірлер: 66
@AaronPowellvox
@AaronPowellvox 8 ай бұрын
I had a replacement that I did where the old unit was almost touching the meter. I had always told the customer about it when doing maintenance. When I went to replace it, the customer and his son helped me make a new flat area 3 feet away from the meter. It was great having all the help.
@NathanZSolomon
@NathanZSolomon Ай бұрын
Many of us customers are willing to help. But we don't want to "helicopter" over you. I think you can sense us as we start talking some of the jargon and yet still don't know what we mean. If you think we're willing to help, just ask. We love to help. I recently replaced the capacitor-only (HERM?) capacitor for my Santa Fe Classic Dehumidifier. I tested it and found it low on ohms. So I replaced it. Too bad it's probably a lack of refrigerant probably due to rub-out of one part or another.
@kens.3729
@kens.3729 8 ай бұрын
This Customer definitely got their Money’s Worth on this Unit. 25+ years old but Not Working because of many issues. Sounds Like the Cicadas were in Town. 😬👍
@kcMan7938
@kcMan7938 8 ай бұрын
I use to carry a bunch of 1” and 2”sheet metal strips cut from scrap that I would use to hold down capacitors and hang line sets . Those older Rudd and Raheem units were tough units . A lot of them still in service .
@justinrichard4190
@justinrichard4190 8 ай бұрын
i like perforated strap, i use it for lots of things
@MiloTorres-yx5jw
@MiloTorres-yx5jw 8 ай бұрын
Always in the plumbing pipe supply area , in the box stores... 👍✌️🙏☝️😎
@kg4muc
@kg4muc 8 ай бұрын
Can’t beat a little corn on the cob after a successful repair! Good job on the repair and cleaning up after the run cap bandit!
@HVACGUY
@HVACGUY 8 ай бұрын
Thanks 👍
@brettwalker4915
@brettwalker4915 8 ай бұрын
I worked at a property in Florida that had these units on all of their apartments. They ran great for many years as long as you kept up the maintenance on them. Easy to work on!
@danobrien3109
@danobrien3109 8 ай бұрын
Code is the same here in Ontario Curtis. Three feet from the meter regulator to the contactor in the condensor. 👍🇨🇦
@kdawson020279
@kdawson020279 8 ай бұрын
NEC loves that 36" of clearance. I freaking wish the places I do electrical work believed in it. I'm getting my 608 cert next month, so I go from relatively experienced electrician to green as hell HVAC guy. So, I get to figure out how much I don't know about the part of the system you feed liquid money under pressure into. These videos have been immensely helpful.
@CA-lk6fd
@CA-lk6fd 8 ай бұрын
We had a Ruud Achiever heat pump for many years on our house, replaced it with a Rheem when it finally kicked the bucket. My neighbors are still using theirs from 1995.
@steveoh9838
@steveoh9838 8 ай бұрын
Nice bonus snack 👍
@HVACGUY
@HVACGUY 8 ай бұрын
Yes it was!
@williamserver4332
@williamserver4332 8 ай бұрын
I love those old rheem units to work on. Great video
@HVACGUY
@HVACGUY 8 ай бұрын
Thanks
@TomLawson05
@TomLawson05 8 ай бұрын
Great job Curtis straightening out the run cap bandit thanks for the video
@robalexander7348
@robalexander7348 8 ай бұрын
Well done Curtis, that was a nice tidy up with this A/C unit, it should run much sweeter now 👍 Au
@jthonn
@jthonn 8 ай бұрын
Another oldie but goodie. Nice re-wiring. It sounded great. I wish they still made them like that. Thanks for sharing.
@ThomasWalker-m2y
@ThomasWalker-m2y 8 ай бұрын
The run cap bandit must have been training his students, There must be a Run cap bandit collage in Georgia. Because those guy's are everywhere . I bet he's offering another course in condenser placement along with the run cap placement.
@alandahlstrom7213
@alandahlstrom7213 5 ай бұрын
Some (a lot) of them migrate south to Florida. My favorite is when they just let it hang by the wires under the fan motor. Tape over the terminals you say? Run cap bandit don't have time for that. Don't get me started on the ones who leave old compressors, fan motors, etc. on rooftops of condos.
@stephenbullock-yn3vh
@stephenbullock-yn3vh 8 ай бұрын
Great job Curtis 👍
@HVACGUY
@HVACGUY 8 ай бұрын
Thanks 👍
@andreeriner811
@andreeriner811 4 ай бұрын
I’ve never seen so many Raheem and Rudd unirs you are always working on. I actually where I live have accounts with both of them. I think I’m gonna start putting them out again. The only reason I didn’t I was getting such a good deal from modern supply and Furgusons and then all of a sudden they got ridiculously high on me. I may try to do some renegotiating with those guys, I like the units
@myfastcars
@myfastcars 8 ай бұрын
Would have enjoyed to see the nasty filter and wrap it up with if it was cooling satisfactorily or not. Love the channel.
@chrisscott1547
@chrisscott1547 8 ай бұрын
It's well agreed that capacitors' lifespan is shortened by heat (most of it internally generated by dielectric losses.) Leaving the cap in the box provides insulation from cooling air and makes the problem worse.
@chrisnapier5626
@chrisnapier5626 8 ай бұрын
Great job,Curtis!
@HVACGUY
@HVACGUY 8 ай бұрын
Thanks!
@stex1985
@stex1985 8 ай бұрын
Corn on cob tip. Can’t beat that😁
@billkunert7281
@billkunert7281 8 ай бұрын
It's nice to see the shrubs cut back from thr A/C
@stevencossaboon3237
@stevencossaboon3237 8 ай бұрын
Nice work Curtis.
@HVACGUY
@HVACGUY 8 ай бұрын
Thanks!
@woodystokes1543
@woodystokes1543 8 ай бұрын
Nice work man 😊as always 😊
@willwise9445
@willwise9445 8 ай бұрын
I see this unit a lot in your videos I bet you know it well
@macogarage6428
@macogarage6428 8 ай бұрын
Nice, nice job. Thank you so much for sharing your experience with us.
@Hornsfan64
@Hornsfan64 8 ай бұрын
2:18 - Based on the tape measure I gave to my wife, that’s way more than 3’ away from the unit!! 😊😊
@buffalobobbayoushow6040
@buffalobobbayoushow6040 8 ай бұрын
A one pole contractor is for “trickle heating” or”trickle charge “.The run capacitor will charge and discharge at 60 HZ resistance in the compressor windings will make a small amount of heat keeping the compressor warm.
@bills6946
@bills6946 4 ай бұрын
If one pole remains live and there is no return path available, how does it keep the compressor warm? It is an open circuit with a leg hot all the time. Look at the schematic on the cover and report back to support your conclusion.
@jeremyfogt6798
@jeremyfogt6798 8 ай бұрын
If I haven't watched you for awhile and know you are a pretty honest guy, a first time watcher would have thought it a little suspect that the unit was running when you got there with a clogged filter and needing a little charge and the next step shows you replacing parts. Just a note for future editing.
@HVACGUY
@HVACGUY 8 ай бұрын
Maybe I could explain better
@Garth2011
@Garth2011 8 ай бұрын
She likely steamed that corn cob in a bamboo basket so it was just right. BTW, all cob corn should be cooked in the husk, never peeled first, as the flavors of the husk transfer onto the corn as it heats. The only way to cook 'em and many folks say no salt or butter is needed when cooked that way as they are so flavorful.
@SergioMeneses2009
@SergioMeneses2009 8 ай бұрын
Lately you have to work in this rudds models
@PosterityOf1776
@PosterityOf1776 8 ай бұрын
No leak test ??
@HVACGUY
@HVACGUY 8 ай бұрын
They didn’t want one
@gas_man1565
@gas_man1565 8 ай бұрын
the relief valve suppose to be 3 ft not the meter its self (-: the relief could be piped away and it would be ok
@YTsux24-7
@YTsux24-7 8 ай бұрын
15:02 "That coil 'probably' has a TXV on it." So you're charging by super cooling, which is a balance between superheat and subcooling? (Edit) I replayed this several times to make sure I actually heard what I thought I heard before responding.
@bobshanery5152
@bobshanery5152 8 ай бұрын
Not sure I understand what you saying. If its a TXV then you ignore superheat and only go by subcooling. Piston you do the reverse. TXV is supposed to maintain a constant superheat.
@HVACGUY
@HVACGUY 8 ай бұрын
Exactly
@YTsux24-7
@YTsux24-7 8 ай бұрын
​@bobshanery5152 Always confirm before adjusting the charge: Filter is clean. Blower is clean. Outdoor coil is clean. Indoor coil is clean. And... What the metering devise actually is. "Probably a TXV" could also be "Probably a piston."
@ryanhutto7724
@ryanhutto7724 8 ай бұрын
The way that subcooling is bouncing. Wonder if it’s got 407 in it.
@harrydickson4575
@harrydickson4575 8 ай бұрын
👍👍👍
@bobstebbins703
@bobstebbins703 8 ай бұрын
👍
@sofalvr
@sofalvr 8 ай бұрын
How are you taking accurate pressure readings with your service bag sitting on top of the condenser fan? That's a very bad habit that I see you do over and over.
@richardwarner2214
@richardwarner2214 7 ай бұрын
You maybe should not have all that stuff blocking the condenser fan, non restricted air flow Is everything in proper HVAC operation.
@randypurdy4085
@randypurdy4085 8 ай бұрын
I thought r22 was phased out.
@jamesjohnson427
@jamesjohnson427 8 ай бұрын
Not for repairs
@UnknownSource08
@UnknownSource08 8 ай бұрын
They don’t make it anymore. What we have is what we have. Over $1000 per 30 pound tank out here in Vegas.
@lencholimited3389
@lencholimited3389 8 ай бұрын
Excuse me sir, part of the country lies in your work.
@davidca96
@davidca96 8 ай бұрын
needs a thirty fahhve fahhve
@JohnSmith-ug5ci
@JohnSmith-ug5ci 8 ай бұрын
Just my opinion but you put that cap in a bad place as it is rubbing up against one of the wires on the contactor.
@rickwilcox3315
@rickwilcox3315 8 ай бұрын
Your Chanel would be alot better and get more subs if you would show some customers redactions... Cheers!! Will sub if that happens..
@HVACGUY
@HVACGUY 8 ай бұрын
I can’t really do that for legal reasons
@rickwilcox3315
@rickwilcox3315 8 ай бұрын
@@HVACGUY Just use the ones that say its ok for you to use in your vids make sure that you have them saying it ok on vid before using? It would help your numbers forsure.
@jm69charternet
@jm69charternet 8 ай бұрын
Good job but i would have ran the yellow low voltage wire under the high voltage wire on the contacker
@danobrien3109
@danobrien3109 8 ай бұрын
Code is the same here in Ontario Curtis. Three feet from the meter regulator to the contactor in the condensor. 👍🇨🇦
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
Гениальное изобретение из обычного стаканчика!
00:31
Лютая физика | Олимпиадная физика
Рет қаралды 4,8 МЛН
This Could’ve Been BAD!!
15:52
Quality HVACR
Рет қаралды 20 М.
THE BEER IS WARM AND BOTH GLYCOL UNIT'S ARE DOWN
30:20
HVACR VIDEOS
Рет қаралды 67 М.
I HATE Mitsubishi MiniSplits
15:41
HVACR Survival
Рет қаралды 142 М.
Homemade Autocascade Refrigeration System (plus Anhydrous Ammonia)
15:57
Hyperspace Pirate
Рет қаралды 122 М.
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН