CV Data Analysis through OriginLab - Calculation of Specific Capacitance - 17

  Рет қаралды 73,979

NanoWorld

NanoWorld

Күн бұрын

Пікірлер: 106
@abdulhaseebhatti
@abdulhaseebhatti 2 жыл бұрын
Sir sir sir sir, wallah it's brilliant... You have no idea how much you helped me
@RahulKumar-wx6jz
@RahulKumar-wx6jz 4 жыл бұрын
Hi man, I have seen all of yr videos. Really helped me in research. Please upload more. Thanks.
@rilujoseph9591
@rilujoseph9591 4 ай бұрын
Excellent Video! So useful!!!!!!
@ananyasagnihotri7333
@ananyasagnihotri7333 3 жыл бұрын
Thank you! Found it very useful. Please upload a tutorial on calculating surface area, heterogeneous rate constant from the Laviron equation using CV data.
@muthiahpillaipalanichamy3939
@muthiahpillaipalanichamy3939 3 жыл бұрын
Excellent presentation. Thanks to you
@nanoworld6122
@nanoworld6122 3 жыл бұрын
Glad it was helpful!
@samiraakif
@samiraakif 2 күн бұрын
Just great. Thank you very very very much. God bless I understood everything.
@amrradwan4279
@amrradwan4279 5 жыл бұрын
Excellent video, go ahead!
@Mosesnewtechnology
@Mosesnewtechnology 2 жыл бұрын
Thank you for that great and easy-to-follow procedure, it's very helpful
@treewhite596
@treewhite596 5 жыл бұрын
Thank you for the content, really useful.
@ZaidLHadi
@ZaidLHadi 5 жыл бұрын
Fantastic ... it's a good idea .. keep going ...thanks a lot
@adithya4993
@adithya4993 5 жыл бұрын
Great content!!!! Finding it helpful!!!!
@shadeepa
@shadeepa Жыл бұрын
Many thanks for uploading. very helpful video
@prg2457
@prg2457 4 жыл бұрын
fantastic job, very informative.
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Glad you enjoyed it!
@RAVIKUMAR39496
@RAVIKUMAR39496 4 жыл бұрын
So great Sir. You have strong teaching skill. Your way of presentation can very nice sir thank you so much
@maedeharvani4124
@maedeharvani4124 4 жыл бұрын
A perfect explanation! Thank you.
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Glad you enjoyed it!
@sumitdubal7887
@sumitdubal7887 4 жыл бұрын
Thank you. Nice explanation. Please share some videos related Galvonastatic charge discharge test with calculation of energy density and power density.
@dr.alial-riyahee1202
@dr.alial-riyahee1202 2 жыл бұрын
Thank you so much dear. I am still waiting additional videos of Cyclic Voltammetry.
@aliyaliyah4759
@aliyaliyah4759 Жыл бұрын
this is really helpful! thank you for explain this
@kevinkantize844
@kevinkantize844 4 жыл бұрын
very very helpful, well detailed, i loved it. Thank you so much.
@shakrajabeen9522
@shakrajabeen9522 3 жыл бұрын
Thankyou so much for sharing.....
@dingzhang3588
@dingzhang3588 5 жыл бұрын
could you please show how to calculate electrochemical active surface area (ECSa)
@farhanzafar9030
@farhanzafar9030 4 жыл бұрын
Amazing work
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Thank you! Cheers!
@공희정-r1h
@공희정-r1h 4 жыл бұрын
Thank you. It is very helpful.
@SMS-yq8ks
@SMS-yq8ks Жыл бұрын
Thanks a lot. It is very useful
@meme1usa
@meme1usa 4 жыл бұрын
I loved this video, thank you so much!!!
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Glad you enjoyed it!
@manzarch2700
@manzarch2700 3 жыл бұрын
very informative👍
@AbdulWahab-ub6kt
@AbdulWahab-ub6kt 5 жыл бұрын
Really helpful and significant video. Thanks a lot for uploading such great work. Dear Team Nanoworld! Would you please attach reference of paper describing this method. It’ll further add authenticity to calculations illistrated in this video. Regards.
@randomthoughts8782
@randomthoughts8782 2 жыл бұрын
ur video is nice but i am facing problem that current at y=axis is in 10exp-7 range and mostly in vidos and reported data it is in 10exp-4 range as is in ur case, m i doing mistake in some conversion or what? please guide
@BiplabKDeka
@BiplabKDeka 3 жыл бұрын
Great explanation. really helpful. Plz make videos on how to calculate Energy and power density with unit conversion.
@aadilkhan9196
@aadilkhan9196 5 жыл бұрын
A.O.A Really good one and nicely explained.But I have an objection. I hope you will try to resolve it. During surface area calculation we should use area within the CV loop , actually you divide the equation by 2 to get that area (area within the CV loop) .But in example solution you have determined that area (within the loop) then you should not divide the equatiuon by 2.
@nanoworld6122
@nanoworld6122 5 жыл бұрын
This formula is used for both, i.e. 2 electrodes as well as 3 electrodes electrochemical work station data. In the case of the 2 electrode system, if we considered the electrodes are symmetric (ideally) then we should not divide it by 2 ( we considered it is already divided). I performed my CV characterization in 3 electrodes electrochemical work station ( As I mention it in my video), that's why I divide it by 2.
@randomthoughts8782
@randomthoughts8782 2 жыл бұрын
@@nanoworld6122 i am facing problem that current at y=axis is in 10exp-7 range and mostly in vidos and reported data it is in 10exp-4 range as is in ur case, m i doing mistake in some conversion or what? please guide
@usamahmahmood1099
@usamahmahmood1099 5 жыл бұрын
very helpful thanx
@zubairahmad2538
@zubairahmad2538 5 жыл бұрын
Thanks for nice video. Could you show how to calculate Capacitance from charge and discharge curves .
@uthmanalli4636
@uthmanalli4636 2 жыл бұрын
Looking forward to this. especially when you have a battery like discharge curve. Thanks
@nilankardiyali8121
@nilankardiyali8121 3 ай бұрын
Sir, what will be the unit of area calculated from the CV curve?
@rana2585
@rana2585 4 жыл бұрын
please add a video on overpotential calculation from CV nd LSV... also for onset potential
@EnglishSimplified27
@EnglishSimplified27 3 жыл бұрын
pls tell what is unit of I current
@mdsaifurrahman5376
@mdsaifurrahman5376 3 жыл бұрын
Thanks for sharing
@AsmaaHamdyTamam
@AsmaaHamdyTamam 11 ай бұрын
really appreciate your efforts. Could I ask how could you calculate the specific capacitance from three electrode system in GCD and CV. thanks in advance
@TheIITianleader
@TheIITianleader Жыл бұрын
please make a video of detailed calculation of galvanostatic Charge discharge for a Supercapacitor.
@Cutepie-tg1re
@Cutepie-tg1re Жыл бұрын
kzbin.info/www/bejne/nIOlloR5hdx2gtE
@collegephysics3362
@collegephysics3362 Жыл бұрын
Nice video
@sharafpc786
@sharafpc786 2 жыл бұрын
What does the capacitance during discharge exactly means? Little confused here.. isn't it the device capacitance? Why need to subtract it from charging capacitance to get the device capacitance?
@Oceancoop
@Oceancoop 4 жыл бұрын
Thanks for nice video.
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Always welcome
@ranaarslanafzal4452
@ranaarslanafzal4452 Жыл бұрын
Can you help me with the Electrochemical active surface area calculation?
@le5722
@le5722 4 жыл бұрын
Thank you for the nice video! When calculate the enclosed area, what is the difference between the function of Polygon-absolute area and Integrate-absolute area?
@mennatullahghaleb5916
@mennatullahghaleb5916 Ай бұрын
Thanks alot
@9847356129
@9847356129 3 жыл бұрын
calculate diffusive and capacitive contributions for electrode material can you do video on this
@Tsastm
@Tsastm Жыл бұрын
Sir what is the interpretation of the area of the CV curve? I mean if it's large what does it say and vice-versa
@jagadeswarchandra4951
@jagadeswarchandra4951 Жыл бұрын
the integration has an error , the v in k is not included
@ruchindagooneratne7684
@ruchindagooneratne7684 4 жыл бұрын
Love all the vids! I do have a question with regard to the final equation. Since the absolute area was used, shouldn't eq (6) be used instead of (10)? Meaning, that the specific capacitance doesnt need to be divided by 2? Thanks!
@muhammadadeelasghar3236
@muhammadadeelasghar3236 3 жыл бұрын
Good observation. I've explained it in my comment.
@troi818
@troi818 9 ай бұрын
@@muhammadadeelasghar3236 Can you explain agian why you did not use equation 6 since the area from origin is already absolute area?
@MuhammadZiaurrehmanFaurooqi
@MuhammadZiaurrehmanFaurooqi 4 ай бұрын
Mashallah great
@renukakumari8064
@renukakumari8064 4 жыл бұрын
Good evening sir..How can I get specific capacity from cyclic voltametery curve?
@raghvendradubey3228
@raghvendradubey3228 4 жыл бұрын
Hi, excellent tutorial...👏 could you please elaborate, how to prepare solution and electrodes configuration during electromica?l process
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Will upload soon
@zahraa3maran
@zahraa3maran 11 ай бұрын
How I can get the file pdf , please.
@sabashahin_
@sabashahin_ 2 жыл бұрын
how to find area under a curve with respect to y-axis on Origin?
@ahmedattia7941
@ahmedattia7941 3 жыл бұрын
hank you for the nice video! When calculate the enclosed area, what is the difference between the function of Polygon-absolute area and Integrate-absolute area?
@uthmanalli4636
@uthmanalli4636 2 жыл бұрын
Can we get an answer to this question, please? I've been curious about it. They both give different values of area, and I've seen different videos where integrate-absolute area has been used instead of polygon-absolute area, Why is this?
@sharafpc786
@sharafpc786 2 жыл бұрын
Yes please
@randomthoughts8782
@randomthoughts8782 2 жыл бұрын
ur video is nice but i am facing problem that current at y=axis is in 10exp-7 range and mostly in vidos and reported data it is in 10exp-4 range as is in ur case, m i doing mistake in some conversion or what? please guide
@kirannargatti
@kirannargatti Жыл бұрын
Really helpful and great explanation. But one thing is not clear, in case of 3 electrode system if we consider absolute area from origin software, then the capacitance equation will be A/2mk(v2-v1) or A/mk(v2-v1)? and in given example, final answer 33.89 is correct or it should be 67.78?
@guadalupesuarez5002
@guadalupesuarez5002 4 жыл бұрын
I have a doubt, the potential is in Volts not mV such as appear in the original file? and the rate scan in mV?
@nanoworld6122
@nanoworld6122 4 жыл бұрын
yes, the potential is in Volts and the scan rate in in mV
@randomthoughts8782
@randomthoughts8782 2 жыл бұрын
ur video is nice but i am facing problem that current at y=axis is in 10exp-7 range and mostly in vidos and reported data it is in 10exp-4 range as is in ur case, m i doing mistake in some conversion or what? please guide
@randomthoughts8782
@randomthoughts8782 2 жыл бұрын
in origin file, potential is in mv range
@IftikharAnfal
@IftikharAnfal 8 ай бұрын
I wish the music was not that dominant
@adillasasongko7227
@adillasasongko7227 2 жыл бұрын
Why it divided by two?
@navinmech540
@navinmech540 4 жыл бұрын
How A2 is just negative of A1? A2 magnitude is lesser than A1.
@ManSingh-mw1il
@ManSingh-mw1il 4 жыл бұрын
i have one query. you have area in (AV), mass in (g), scan rate in (mV/s), potential window in (V) so how do you got capacitance in F/g. I think area should be in (mAV)
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Please re-watch this video, and note everything in your note book and then re-think about it.
@ManSingh-mw1il
@ManSingh-mw1il 4 жыл бұрын
@@nanoworld6122 yes sir, i got it now, you have converted scan rate into V/s during calculation. Thank you for replying sir.
@shelkaze6242
@shelkaze6242 4 жыл бұрын
thanks for tutorial, much helpful.lol
@speedstar6140
@speedstar6140 4 жыл бұрын
Don't you think that the unit of scan rate should also be V/s instead of mV/s that you are using while calculating Cp in excel sheet. Since 1 F is equal to 1 A.s/V
@nanoworld6122
@nanoworld6122 4 жыл бұрын
I think you did not watch it carefully. When putting formula, I multiply it with 10^-3. This means I already used V/s for the rate. Please re-watch
@speedstar6140
@speedstar6140 4 жыл бұрын
@@nanoworld6122 Ok
@subalakshmi3835
@subalakshmi3835 4 жыл бұрын
thank you
@nanoworld6122
@nanoworld6122 4 жыл бұрын
You're welcome
@mohamedbousnobra7989
@mohamedbousnobra7989 2 жыл бұрын
Merci bien pour la video. Quel est l'intervalle de Cp qui permet de juger que le matériau étudié peut être utilisé dans le stokage des énergies? Est il possible d'avoir le contenu de cette video sour forme de fichier word ou pdf
@yhana8836
@yhana8836 4 жыл бұрын
Hi, I have a question. How ti know the mass of active material
@nanoworld6122
@nanoworld6122 4 жыл бұрын
Hello Mulya, You can measure it through weight balance.
@mouhcineazriouil4544
@mouhcineazriouil4544 3 жыл бұрын
@@nanoworld6122 I think the masse used in the preparation of concentration which the CV recorded in.
@SiddhantB9
@SiddhantB9 5 жыл бұрын
Very helpful video, thanks a lot. I had a question which I hope you'll help me with. Why is the area A2 = (V1 - V2) Cp*m*k at 6:36?
@nanoworld6122
@nanoworld6122 5 жыл бұрын
This was for discharching of capacitor.
@chemistrybangladesh
@chemistrybangladesh 5 жыл бұрын
nice
@shashikantyadav1473
@shashikantyadav1473 3 жыл бұрын
Hi Sir, Can you please provide that CV data excel file. I just want to plot and calculate the area for discharging time? If possible please help me with charging and discharging formula on the basis of C&V. Thanks and regards,
@mohammadmansour5299
@mohammadmansour5299 Жыл бұрын
Please i need this word document quickly😢
@NareshKumarD17
@NareshKumarD17 3 жыл бұрын
could you please share this word file
@nanoworld6122
@nanoworld6122 3 жыл бұрын
Please send me an email asking for the file.
@zahraa3maran
@zahraa3maran 11 ай бұрын
@@nanoworld6122 your email,please 🙏
@wildamardhatillah5784
@wildamardhatillah5784 3 жыл бұрын
「ビデオサウンドは、私の想像を超えて、かなり良いです」、
@kusuma33
@kusuma33 Ай бұрын
alhamdulillah.....
@renukakumari8064
@renukakumari8064 4 жыл бұрын
Please reply sir 🙏
@loverspptloversppt1480
@loverspptloversppt1480 2 жыл бұрын
you need to clarify the content
@uchechichibukomiracle1958
@uchechichibukomiracle1958 4 жыл бұрын
Thank you
@nanoworld6122
@nanoworld6122 4 жыл бұрын
You're welcome
@novmannabeel8080
@novmannabeel8080 Жыл бұрын
thank you
Dunn Method Clarification Step by Step
18:20
Haff East
Рет қаралды 9 М.
The Lost World: Living Room Edition
0:46
Daniel LaBelle
Рет қаралды 27 МЛН
Getting Started with Cyclic Voltammetry
23:20
NSF Center for Synthetic Organic Electrochemistry
Рет қаралды 64 М.
How to determine the specific capacitance from cyclic voltammetry data
21:20
Cyclic Voltammetry
20:50
Michael Vitarelli
Рет қаралды 22 М.
Cyclic Voltammetry: Interpretation of Simple Cyclic Voltammogram
13:43
Pumidech Puthongkham
Рет қаралды 50 М.
Tutorial 17-Current dependence on scan rate from CV
6:18
EChem Channel
Рет қаралды 28 М.
Day in the Life of a Data Analyst (Work From Home) | *Realistic*
9:05
Coding with Dee
Рет қаралды 194 М.