Every house I have owned I have done this. Great job!
@gordiehattrick9 ай бұрын
Great video! Keep in mind, that genny puts out a high THD. Be careful powering sensitive electronics, which is just about everything today. The Westinghouse WGEN115000TFC has a bit more power output, is TriFuel and the most important feature is a THD less than 5%.
@deanowright3595 ай бұрын
Thanks for this useful information Just bought a 13000 Predator Will go Shipp for a Westinghouse They are hard to find
@marcusguajrdo735 ай бұрын
Cheap generator predator uses copper wire
@benton920743 ай бұрын
@@marcusguajrdo73 Seems odd that Predator only offfer 90 day warranty and Westinghouse comes with a 3 year warranty if its so cheap why such a big difference. I did some research and most of the Westinghouse are copper wound as well. They do have a few aluminum on the very low end, but most are copper wound I think. I am still shopping around myself.
@jonny85473 ай бұрын
I keep reading statements like this everywhere but I also keep hearing that it’s not a big deal and people have been using regular generators for decades with no problem. Even the power company has a much larger total harmonic distortion than 5%. I’m still shopping around d myself and don’t claim to be an expert
@stinerart1Ай бұрын
An electrical engineer tested a 13k tri with a legit meter device and got 6%. Just because predator states the 23% does not mean it is that high. Funny that there is always this comment, duromax reps earning their coin for sure.
@alanjbuddendeck18610 ай бұрын
Very informative. Straightforward, clear and very easy to understand. Really appreciate the helpful information. I'll use this to ask my electrician about a propane-based whole-house solution for my house and barn. Again, very helpful and clear. Much appreciated from the Virginia Piedmont.
@Create20810 ай бұрын
Thank you!
@brandonmartin92985 ай бұрын
Man that interlock is a great idea! Thanks for showing that!
@Upwegoo10 ай бұрын
You are very inspiring and this is the kind of life I’m starting to build
@Create20810 ай бұрын
Thank you!
@AXNJXN15 ай бұрын
Excellent video and I have the same Generator thus, purchased it for this exact same need. It's a dirty sinewave but it gets the job done for the cost value. I'll be doing the exact same transfer switch setup, with the only exception of upgrading to 6AWG for load values vs the 8AWG and never have to look at it again. Thank you for the clear shot video.
@ACommenterOnYouTube4 ай бұрын
how do you know its dirty ?
@timnevitt29933 ай бұрын
@@ACommenterOnKZbin because it dont have inverter to clean up the power wave
@ACommenterOnYouTube3 ай бұрын
@@timnevitt2993 well dirty power does not hurt electronics as most electronics have filters on their input power supply. Next its the voltage spikes that hurt the electronics. Most electronics use 105-240V so any voltage in that area is safe, if the voltage goes above 240V, thats when you have an issue. Next most name brand generators might have "dirty" power but they clean up once they go under load. They are only "dirty" when on idle and no load because there is no reason to be clean with no load. Next a guy here on KZbin did show a champion generator and showed the "dirty" sinewave under idle but when he put a load on it, it cleaned up a lot.
@stinerart1Ай бұрын
@@ACommenterOnKZbin my 13k has run everything no problem. No flickering or drama from devices at all.
@ACommenterOnYouTubeАй бұрын
@@stinerart1 I believe that "clean" power is a $$ scam gimmick. And i have seen the sine wave from an inverter generator and its actually CLEANER than the power from the utility. And if the utility power being somewhat dirty does not damage electronics, i dont think a little more dirty power from a generator will do anything. As i said before, there is NO evidence of electronics being damaged from "dirty" power but def YES from voltage spikes
@muaythai11878 күн бұрын
Exactly the guidance that I needed. Thank you.
@russgenders75507 ай бұрын
dude!! killer. Thanks for this video. I'm so sick of our power outages over here been looking for an affordable solution!
@2AToday10 ай бұрын
Great video! Love what you did with putting the channel name above the work bench btw
@Create20810 ай бұрын
Thank you!
@CremeDeLaCreme729 ай бұрын
Any info on how long a tank of propane will last on continuous run and what the decible level is of the generator?
@jwhite266 ай бұрын
Well depends on what size tank I bet.
@mcw15939 ай бұрын
Considering that some high current loads could be active at the time of disconnect, I would flip the generator input breaker at the panel first instead of at the generator. Why? Because opening a circuit with high current flow will cause an arc and the breaker in the panel is more durable than the ones they installed in the generator. It is also easier to replace on failure.
@Create2089 ай бұрын
Thank you for the info!
@34dawgsgo7 ай бұрын
Thanks. Good to know these connecting steps. Easy to forget. Have the same setup for 2nd home. Duromax 1300 dual fuel.
@3gasman6 ай бұрын
I just purchased the same generator for our new house. I had electricians wire a power feed from my shop back to the house during the build. I can now power back to the house main panel from the shop and only need to roll generator around the corner under my porch roof
@prestonrenify2 ай бұрын
You made that look so easy...thanks. Suggest you take a serious look at the power quality rating of that generator (THD
@FireoftheGreeks10 ай бұрын
Pretty sweet setup! One question though, why do you have your panel outside the house and not in the shop? Worst case situation: Someone could roll up and shut the entire house down from outside.
@Create20810 ай бұрын
Thank you! I have that panel outside, a 200a sub panel in the shop, and a 125a sub panel in the living area. Most houses have a main disconnect at the service panel outside like mine. It’s pretty crazy but yes, a lot of people could have their entire house shut down from the outside!
@peterkohler725910 ай бұрын
Beautiful home and great idea. I did the same thing on my house a couple years ago. Is there a reason you used 8 GA versus 6 GA? 8 GA is rated for 40 amps whereas 6 GA is 55A. Typically use 6 GA wire for 50A breakers. By code around here you’d have to swap out the 50A breaker for a 40 since the wire couldn’t handle the 50A. Just wanted to make sure you knew that. Cheers!
@Create20810 ай бұрын
Thank you! Wire size depends on a few factors, if you are using a romex or cable you would size off the 60 degree chart but because I’m using THHN wiring it’s rated for the 75 or 90 degree chart. 75 degree chart for #8 is rated for 50a and 90 degree chart is rated for 55a. But that’s why the premade cable had to be #6 wiring. because the 60 degree chart. Hope that makes sense!
@LandonLavore7 ай бұрын
Per NEC your are not to exceed 80% of the load. That would fail inspection with 8AWG. Just be careful doing DIY.
@Create2087 ай бұрын
Code reference?
@jwhite266 ай бұрын
He knew
@AstroRocketDogs4 ай бұрын
Did you have to mess with the generator to change bonded neutral to floating or is it ok to leave it as is?
@avguytx43617 күн бұрын
It needs to be floating neutral to run to a house and not bonded. Bonded is when you run the generator as a stand-alone for tools, etc.
@tomryan46483 ай бұрын
Great video, well explained
@marklloyd41535 ай бұрын
I saw a short video on this generator not put out the right amount of power damaging stuff in the home . No problems on your end ? I’m thinking he was trying to sell a voltage reader
@jackd74944 ай бұрын
Well done young man.
@jimmybrad1568 ай бұрын
Nice view @ 12:00
@Howard8923 ай бұрын
Will that setup run the house AC unit as well?
@marcusharley3064Ай бұрын
Will not run an entire house with AC/Heater running. You need at least an 18000 kvw generator to barely run everything in your house. If you want to run your AC, Heater, fridge, septic pumps, TV, a couple lights, you need 26000 kvw generator.
@avguytx43617 күн бұрын
@@marcusharley3064 False
@robertduncan27423 ай бұрын
Would this unit run a smaller home with furnace, refrigerator, freezers, ac and accessories to dryer
@robertclemmons72812 ай бұрын
Great video by the way
@paulvaso8524Ай бұрын
8:24 u can see the light in the back normal, and at 10:55 we can see it flashing. That means the energy quality must be pretty bad
@marcusharley3064Ай бұрын
You are very correct, plus it was barely powering his house.
@randydobson81487 ай бұрын
Great video...I am going to do this very soon. One question. When you say the entire house, does that include the central AC? Thanks
@Create2087 ай бұрын
Thank you! Yes it does.
@lapprentice6 ай бұрын
Make sure you install the Easy Start to your AC to ensure you can run AC with any portable generator.
@randydobson81486 ай бұрын
@@lapprentice Thanks for that information. I will call my AC company and see what they say.
@marcusharley3064Ай бұрын
@@lapprentice With the easy start it does help, but you still need to have enough KVWs to run your entire house.
@SuperBiz247 ай бұрын
Can see your light surging in shop.. what’s thd on this unit.. I’m looking to do same and had this one in mind or the 9500 inverter
@projectswithjw6 ай бұрын
23%
@benchoflemons3985 ай бұрын
Probably terrible. No inverter
@marcusharley3064Ай бұрын
It's not an Inverter generator, with a surge like that, it will burn out your smart TVs and computers, and cable box. And it was surging because it was barely powering his house.
@joshe95185 ай бұрын
Electrician here.We generally use #6 for 50 Amps.However, those short whips being #8 shouldn’t cause issues. That said great set up. I’m about to do the same thing at my house. I’m running natural gas though.
@ryancashmore7924 ай бұрын
Great video and nice setup. This is the only video I’ve found where the generator inlet box is attached directly to the side of the panel. Is that acceptable? Is there a reason more people don’t do it? Thanks.
@mikekjellman10 ай бұрын
well edited!
@Create20810 ай бұрын
Thank you!
@NeoB-Lac5 ай бұрын
The sinewave is very dirty on that generator, look at the light at 8:24 compared to 10:54 you need an inverter generator
@CadeSubscriptionAccount5 ай бұрын
That has less to do with THD and him trying to draw more than it can supply.
@Turbo_Todd4 ай бұрын
Only need sine wave for sensitive electronics, but you can buy inexpensiveline filters and protect everything. Way more affordable. That said, I've been using noisy generators for years and never had a problem.
@yuriys31643 ай бұрын
Can you link what some of the filters are? This is a great idea, have not heard of this option before
@marcusharley3064Ай бұрын
@@Turbo_Todd Ad a surge protector to your panel box.
@robertclemmons72812 ай бұрын
I have the same generator you do. How can I get a list of items that you used for your project. I want to do the same thing. Thanks.
@cashmoreoctober19733 ай бұрын
Thanks i have the same generator but dont know how to setup my home. I have a fuse panel so im not sure how to connect it because it isn’t a breaker panel. I know i need to pull the main out when using a generator but can i use a fuse instead of a breaker to feed my generator into the home?
@RonaldBattagliaJr8 ай бұрын
What 50amp cable did you purchase?
@jkidd200710 ай бұрын
I'm new here and I don't see a link to "the web site" for a list of parts.
@Create20810 ай бұрын
Sorry I forgot to add it to the description. I got all of my parts from www.geninterlock.com
@codyschwoch54513 ай бұрын
Those that are thinking of generators, I would recommend this generator due to the price of it, as well as the fact that it is multiple gas if need to be, but one thing that I would like to let people know since I own it, I would know getting more wattage using Gasoline so that 13,000 W is gasoline and on a raisin occasions you can get close to that with propane but not completely with propane you can get about 11,000 W maybe 12,000 W so that’s something for people to think about if they’re looking for a generator is yes you get a generator that gets multiple gasbut each gas type produces a different amount of wattage
@lishajoyh81546 ай бұрын
Like a damn boss bro great video!
@oscarpuente20294 ай бұрын
got the generator, now I need the wire up kit.
@PartneredAdmin5 ай бұрын
Who does the install? Can you please recommend someone in Houston area?
@carloswaters99377 күн бұрын
Not being a electrician. How mutch you think it would be to hire somebody?
@asgard16810 ай бұрын
How does one know if power from the main grid is back?
@Create20810 ай бұрын
I’m pretty sure the meter readout would only be on if the power was on. So if that readout was visible the power should be back on.
@balexan5307 ай бұрын
You need to change your wires to 6 gauge if you want to use the 50 amp breaker. Number 8 is rated for 40 amps and number 6 is rated for 55 amps. Currently you will burn up your wire before you trip your breaker.
@Nicholas2011ist7 ай бұрын
The chances of the generator putting out more than 9600 watts continuously (40 amps at 240V) is pretty low. There's circuit diversity factors that can be taken into account. Ampacity is also dependant of the temperature rating of the insulation and the length of the run.
@balexan5307 ай бұрын
@@Nicholas2011ist breakers are sized to protect the wire. It would never pass inspection. It's your building.
@Create2087 ай бұрын
Unless I’m missing something, #8 THHN on the 75 degree chart is rated for 50a.
@rab1255 ай бұрын
What is the dimensions of the box-- the generator comes in. Wanting to know if I need to rent a truck or my van can work.
@juliocs54835 ай бұрын
A lot of businesses ship for free…I got a generator from HD and they shipped. Cus yes they are heavy.
@marcusharley3064Ай бұрын
If your van has double doors, it's more than enough.
@Defianthuman5 ай бұрын
I'm sure it charges it on its own battery charging but I have also seen people who plugged the trickle charger into one of the 120v outlets, and had additional charging while running seems unnecessary.
@codyschwoch54513 ай бұрын
And if you use propane, you should always slowly open your propane tanks just opening them full blast like he did could potentially run the propane control bladder system
@richardliandro27896 ай бұрын
Can it power 3.5 ton ac unit also
@marcusharley3064Ай бұрын
No
@josenavarro-ue7zu7 ай бұрын
dude, you need #6 for a 50 amp not #8. under size wire will heat up and catch fire before the breaker trips under the rite conditions!!!!
@Create2087 ай бұрын
Code reference? #8 THHN on 75 chart is 50a?
@DougP-q4d6 ай бұрын
He is probably thinking about NM not THHN but you aren’t supposed to exceed 80% of the rating for safety so #8 THHN would be 40amp continuous safe but I’d guess you’re fine either way.
@sn0isle4 ай бұрын
The generator is only capable of 41 amps at max load with gasoline. On propane is 9100watts 9100 divided by 240 volts equals 37.9 amps.
@realamericanz46414 ай бұрын
I’d imagine in real life if he’s running absolutely everything and taching out that generator. He could walk over and grab that extension cord, Feeling of it. I’d be shocked if it was ever hot or even warm to the touch. I’ve been running set ups just like his for years myself.
@OLSMOKY3 ай бұрын
Super helpful to former city-folks like me! 😂
@thm35257 ай бұрын
Great video.
@potlickerhound726210 ай бұрын
hows my boy Jet a doing?
@Create20810 ай бұрын
Unfortunately Jet passed away last year.. But you can see our dogs Mesa and Roxi in this video!
@juansifuentes39176 ай бұрын
Bit of advice, change that #8 wire and replace it with a #6 wire.
@timdixon922425 күн бұрын
Folks You can use a surge suppressor in line for electronics with these. Other than that nothing else is going to be affected greatly.
@gilt93776 ай бұрын
Dumb question..The output plug on the generator says 42 amp max...why do you say it has a 50?
@projectswithjw5 ай бұрын
The outlet is a 14-50R. It is a 50 amp receptacle whether or not the generator can put out 50 amps.
@ACommenterOnYouTube4 ай бұрын
10k running watts for $1100 ...... How dirty is that power after 50% capacity ??
@marcusharley3064Ай бұрын
It's a 13,000 running 10,500 watts.
@ACommenterOnYouTubeАй бұрын
@@marcusharley3064 No its not. Its 13k STARTING watts and 10k running watts
@marcusharley3064Ай бұрын
@@ACommenterOnKZbin Forgot my comma man, 13,000 , running 10,500 watts.
@ACommenterOnYouTubeАй бұрын
@@marcusharley3064 You are still wrong. To correct you a 2nd time: Its 13,000 STARTING watts AND 10,000 RUNNING watts
@RLoose949412 күн бұрын
The whole gist of having a backup source is for emergencies. Run only essentials so the argument is over nothing, either have some power or do not have power.
@davidlemay47619 ай бұрын
Remember to buy spark plugs for your generator.😅
@JacobBitner6 ай бұрын
Ha, I'm in Houston now and it's day 8 with no power. 10w30 oil is hard to find, spark plugs are scarce and anything electrical related to generators are sold out so everyone stock up on these extra parts. Filters, plugs, oil, and definitely gas
@CadeSubscriptionAccount5 ай бұрын
Don't run 10w30. Run 0w40 or 5w40 full synthetic. They hold up much better. Even still, I drain and fill every 48 hours of constant run time.
@TonyStewart-wl8dv7 ай бұрын
So if you can run 8 hours on five gallons to run 24 hours at 3 dollars per gallon that’s 45 dollars a day to be smart about this having a battery backup would help but yes the battery are not cheap. Good video guy.
@NHWilderness9 ай бұрын
I’m in ahh of the landscape,not a neighbor in sight
@justincunha522128 күн бұрын
Should have used 6G wire with 50 amp breaker
@jonkenny5938 ай бұрын
What is the winding made of?
@kaidenstowell848710 ай бұрын
I sent you an email about an emergency hand pump I own a company that build easy to use and install emergency hand pumps for wells
@brianharris70292 ай бұрын
I don't know why predator generators don't automatically charge the battery, annoys me that you need a seperate cable to charge the battery
@DieselGeneratorfromALAD7 ай бұрын
any needs of generator power range 1kw-2500kw , feel free to let me know.
@michaelhardy1955 ай бұрын
Good idea Eco flow delta pro 3 system check online and emergency backup power whole home
@theMister072 ай бұрын
I’m considering the Ecoflow DPU
@jmd1653 ай бұрын
#6 wire is for 50 amps. #8 is for 30 amps he keeps saying #8 wire but it looks like #6
@Tylers247 ай бұрын
Skipping through parts on the video. No sub. Show the entire process
@sinner-saint3616 ай бұрын
67 bucks for that little piece of sheet metal? Stupid expensive
@XxAtomic646xX9 ай бұрын
how is the thd on this? id be worried about powering tvs and shit on something with higher than 5% thd
@CadeSubscriptionAccount5 ай бұрын
TVs arent really a concern anymore. Stoves, fridge, AC... That's what Im worried about.
@brianharris70292 ай бұрын
23%
@marklloyd41535 ай бұрын
I saw a short video on this generator not put out the right amount of power damaging stuff in the home . No problems on your end ? I’m thinking he was trying to sell a voltage reader