New Gas Furnace Careless Installer Mistakes

  Рет қаралды 92,220

Anti DIY HVAC

Anti DIY HVAC

Күн бұрын

Пікірлер: 288
@thecatdaddy1974
@thecatdaddy1974 2 жыл бұрын
Everyone says what you should do or have your guys to do, But I like your honesty and shows we are humans and make mistakes, checklist or not.
@joekerr8634
@joekerr8634 5 жыл бұрын
Your guys should test fire everything, summer or winter.
@juancastillo5078
@juancastillo5078 4 жыл бұрын
I thought the same thing... even if it is nat gas, dial both in, test fire, check pressures everywhere and room temps. i got so annoyed at a previous employers! that being said, we always test fired and gave it a good burn in
@F150_King_Ranch
@F150_King_Ranch 5 жыл бұрын
This is why my company has a service technician do a start up on every new install to insure job is done correct and equipment is working properly
@MikeLeonard
@MikeLeonard 5 жыл бұрын
Same. Adjust refrigerant. Combustion analysis. Test wiring and safeties.
@bahopik
@bahopik 5 жыл бұрын
@@giggleherz I'll take one too
@sknight0391
@sknight0391 5 жыл бұрын
Usually the crawl space ends up being "worse" than what you thought it was going to be. That's a nice one.
@mattbauckman9907
@mattbauckman9907 4 жыл бұрын
I usually disable the fan and burn in the heat exchanger until the limit trips. Also should document inlet gas pressure and manifold pressure. Up here in the Northeast there’s a minimum clearance of 10’ for condenser near the gas meter. Start up sheets are a requirement at my company. Everything gets documented and put in customer file. Gas pressures, voltages (primary AND secondary), what metering device, subcool, superheat, delta t, model, serial, filter sizes. Also a combustion analysis with 2 copies printed out, one for on site and one for the file. Good install and service techs don’t often come naturally, they have to be created. I wish I had a Chevy van like yours instead of a Ford Transit. I’ve had both and prefer the GM. The side access is awesome too. Love your vids 👍
@naturekid1335
@naturekid1335 5 жыл бұрын
Back in my installer days, we had a startup sheet checklist we had to fill out and sign, before turning in to the office. Avoided lots of stupid callbacks. My current company doesn't, and as the service tech that has to go back and tighten wires and connect drain hoses, drives me nuts, especially on super busy days. During last service meeting, service manager said he is going to start implementing them as the callbacks have gotten out of hand lately. Bout time.
@scottk0623
@scottk0623 4 жыл бұрын
Ted, people can say what they like. I like the fact that you show it all good or bad their fault or yours, we all have the same issues unless your a “Super Tech” I haven’t seen one yet. Thanks for the candid video’s
@55metalmonkey
@55metalmonkey 3 жыл бұрын
Ted, make a commissioning sheet for your installers. We use them and it keeps people from making goofy mistakes at the end of a long ass day in the freezing cold or baking heat. Prevents a lot of call backs for dumb stuff and proves they system works correctly and within manufacturers spec.
@1948Noam
@1948Noam 2 жыл бұрын
After every installation we always ran the units through a test on all safety features. Out of season we returned to check A/C or Heating whatever the case maybe! Great job!
@fsu3784
@fsu3784 5 жыл бұрын
I’ll move to S. C. To work for you! Been installing for 16 years and love it. Was slow at first because I was too particular about how good my work looked but never sacrificed that for speed just got faster. Work smarter not harder. Love the channel!
@larrykeenan598
@larrykeenan598 5 жыл бұрын
My son manages a large HVAC company (around 150 employees) in eastern North Carolina. They have installation crews and also startup techs who do all startups and tests. Installers are not expected to do startups. The tech does an inspection before startup and notes problems. If they are minor, the tech will fix them. Major problems go back to the installation crew who make the repairs on their own time.
@mikejones-ku5ix
@mikejones-ku5ix 5 жыл бұрын
Good luck bringing people back on their own time for any mistakes. Also that is illegal to have a guy work for free. Let him get hurt on that job off the clock and your brother will be working at Walmart as a door greeter.
@DoctorMeh
@DoctorMeh 5 жыл бұрын
Holy shit. This vid helped me with my HVAC and about a week later my neighbors. Thought you should know and Thanks!
@fighkb
@fighkb 5 жыл бұрын
Having a checklist after installation may help avoid this issue, I like your videos thank you for sharing.
@HockeyTownHooligan5
@HockeyTownHooligan5 5 жыл бұрын
Fernando Garnica When I used to do install, we would always run the unit through a few start ups to make sure it worked before just leaving. Even when we did furnace changes in the summer, fire it up and see if it works! AC we had to wait until it was warm enough to get good pressure tests.
@seroxide
@seroxide 5 жыл бұрын
I agree. I have a friend that requires a check sheet be signed off on on every installation. He said it all but stopped call backs.
@ZERO-F2G-
@ZERO-F2G- 5 жыл бұрын
@@seroxide In 33 years I have yet to see a checklist stop callbacks. Ive seen a lot of those signed off on, yet still had a callback that was on the installation crew. But as a manager what I have found to reduce them to near none, is good training, and competition. No callbacks on installer error equals a bonus, since they all vie to be number one they pay far more attention than a check sheet to sign provides.
@fespinoza287
@fespinoza287 5 жыл бұрын
Fernando Garnica a checklist is a great idea. However they’re only as effective as the installers who fill them out. Can’t tell you how many times I went on callbacks, coming behind the install crew who checked all the boxes, to find the things they said they did were not done.
@Ericbakereb1
@Ericbakereb1 5 жыл бұрын
I'll be a perfect installer when you show me s perfect service tech
@its_bob_from_accounting801
@its_bob_from_accounting801 5 жыл бұрын
nailed it.
@jacklynn6164
@jacklynn6164 3 жыл бұрын
what you dont start and check after a install
@brianfoughty9006
@brianfoughty9006 5 жыл бұрын
Hey ted big fan of your videos man you do great work. My only thing is if that gas valve was still shut off from the factory then nobody set gas pressures on that furnace.
@James_Bowie
@James_Bowie 5 жыл бұрын
The very least you'd expect an installer to do is to actually TEST the installation.
@williammarik6159
@williammarik6159 5 жыл бұрын
Ted. As a contractor in Cleveland,heads would roll.
@Eddy63
@Eddy63 5 жыл бұрын
Great crawl space and great vid ... Don't be to rough on the installer they all make mistakes ...
@ares3914
@ares3914 5 жыл бұрын
I started in residential and now I'm in industrial. Residential is full of green guys. You may need to look in commercial or industrial hvac techs for s good installers
@NorCal-refrigeration
@NorCal-refrigeration 5 жыл бұрын
Nothing like working for free. It happens. Great time to set gas psi and check temp rise. It must have been hot 🥵 as heck during install.
@throttlebottle5906
@throttlebottle5906 5 жыл бұрын
I agree, that's a deluxe crawl space, I also love when attics have a large cat-walk and full head height, but a few obstructions for you to duck under. you normally wont get either unless it's McMansion lol
@picturemetrollin2093
@picturemetrollin2093 5 жыл бұрын
I always check gas pressure on a fire up. I learned that lesson the hard way! The installers took out a regulator and tied the new furnace into a 2lb line! When I turned on the gas I ruptured the diaphragm and the house filled up gas...... like to have sh*# my pants when I come from the odu! lol I'll never forget that lesson.
@ezekiellackey3439
@ezekiellackey3439 3 жыл бұрын
Ted, I'm from Ohio. I just make take you up on the job offer if I ever move that way. Love your style and personality.
@7_sn2
@7_sn2 5 жыл бұрын
Question... How can you possibly leave an installation without checking combustion, pressures, o2 levels etc. I am not a gas ticketed guy, but I have seen some crazy tagged installs. The last one I just looked at the installer allowed glue to run over two of the three burners, leaving furnace to run on a single flame. Wrote his tag and left. Where is the over site in this industry?
@bentrujillo6406
@bentrujillo6406 4 жыл бұрын
I would ask you don’t your guys do a start up at the end of a install? How do you know gas pressure in and out ? Temp rise? How come you didn’t do that since you know it has never been started?
@audiedickert1745
@audiedickert1745 5 жыл бұрын
Sir, I could be wrong but I believe you were looking for me. Im as close to a Perfect installer as it comes. Lol. Never been to S. Carolina but I've been looking for a new town to move to for a couple years. Until my daughter turns 5. Once shes 5 I gotta go where ever her moms living. But until she starts kinder I can pretty much go where ever. "@Anti DIY HVAC"
@christophermiller1520
@christophermiller1520 5 жыл бұрын
I’m an excellent installer and sheet metal guy with 20 yrs experience and have really been thinking of relocating. I have plenty of pictures of my installs and references. I own a small company but I’m getting tired of the northeast
@ajeberhardt3106
@ajeberhardt3106 5 жыл бұрын
I wish I was able to go to a new install and find the gas valve off and just turn it on and walk away. Be in and out in 10 mins but if they left that gas valve off then that means they didn’t test run the system. Now it’s my responsibility to make sure the system it set up properly. Meaning you should check and set up the gas valve to proper pressure with the doors on. All gas appliances should be running at the same time. Also have to take temp rise across the heat exchanger to properly set up the fan speed in heating. Then with the fan speed set properly you can now check static pressure of the system and verify it’s within range pre manufacturers spec. Also drill hole in venting to preform a combustion test to verify the system is burning properly. Make sure the crawl space door is closed and the furnace door is on to get actual readings. After completing the combustion test use fire Rated silicon to seal up the hole. Also fill the condensation collection trap so exhaust fumes are leaking into the crawl space/home from the condensate. But that’s just me. I would feel right just walking away cause I’ll be responsible if some was to happen.
@TedCookHVAC
@TedCookHVAC 5 жыл бұрын
Valve switched off to remove manometer and forgot to switch it back on ..... so I was told anyway.
@ajeberhardt3106
@ajeberhardt3106 5 жыл бұрын
That may be the case but I’m particular so I would end up having to go through it all over I didn’t see a hole for combustion and or holes for statics I could of very much missed them in the video but I would go about it like a system start up. How come you don’t run fresh air in to the furnace.
@bymarksheetmetal8998
@bymarksheetmetal8998 5 жыл бұрын
Get a cover on that switch
@stylez8444
@stylez8444 5 жыл бұрын
Personally i test heat and cool idc what season it is. I wanna walk away knowing I did everything 100% take pride in what I do.
@roadhammmer
@roadhammmer 5 жыл бұрын
Give him the nickname gas valve bandit
@Tradesmen
@Tradesmen 2 жыл бұрын
Good stuff. S. Carolina must have an amazingly low cost of operating a business. Cost of living must be amazing as well. Texas will average $1200-$2500 daily depending on the city your installing in. For someone with 10+yrs of installing.
@mikeantj
@mikeantj 5 жыл бұрын
I like the linesets just lying on the ground in the crawlspace
@tytig94
@tytig94 5 жыл бұрын
Your not the only one going through this lately. Our company has had lots of call backs lately for closed gas valves, and off switches(mostly PM's). Just leave the damn thing running when you leave!!!
@macmac3374
@macmac3374 5 жыл бұрын
That's standard company procedure at my company. Always make sure the system is functioning properly and on before walking out the door.
@picturemetrollin2093
@picturemetrollin2093 5 жыл бұрын
First thing you do on a pm is make sure it works! Last thing you do on a pm is make sure it works! lol
@easymoney1590
@easymoney1590 5 жыл бұрын
Maybe you should test your gas pressures and get a delta t when initiating a new unit
@altarara9858
@altarara9858 4 жыл бұрын
Furnace number two: the 3”x 2” pvc coupling is supposed to be installed right on the top of the furnace.
@jorgeespinoza4002
@jorgeespinoza4002 2 жыл бұрын
God You Are Good! 🙏🏼❤️
@MindzEnt
@MindzEnt 5 жыл бұрын
Even techs do it sometimes when doing heating maintenance, so I won’t bash installers for leaving gas valve off.
@its_bob_from_accounting801
@its_bob_from_accounting801 5 жыл бұрын
nailed it
@redxraider0613
@redxraider0613 5 жыл бұрын
I had one the other day, new unit installed in the summer and first cold snap heat didn't work. I was training a new guy and I said "bet you lunch its the gas valve" long story short he owes me lunch
@kingconker7795
@kingconker7795 5 жыл бұрын
I had a no heat call yesterday where one of our installers didn't connect the drain on a 90 percent and flooded the whole basement till it finally kicked off. 👨‍🎓👨‍🎓
@royalwins2030
@royalwins2030 4 жыл бұрын
Near perfect employees are almost impossible to find. Those that are very very good typically start their own businesses.
@gerryrig5012
@gerryrig5012 5 жыл бұрын
Installers Should Test Both A/C Cooling AND Heating Test Even If Its In The Summer To Make Sure That Furnace Is Ready When It Gets Cold Next Week...
@phildegruy9295
@phildegruy9295 9 ай бұрын
I would make sure the installers or Tech in charge test the A/C, Heat, check/set gas pressure, verify/adjust refrigerant charge, record values, and otherwise commission the unit and explain to the homeowner how the new thermostat operates and what to expect with the new system?
@jandeband
@jandeband Ай бұрын
Yu did not explain the first one, question, i converted from nat gas to lp, should my furnace fire up with nat gas residue in the supply line ? Thanks
@m3maximation
@m3maximation 5 жыл бұрын
I found a gas valve shut off a couple weeks ago on a new install. Fired right up!
@mychoclabwinston
@mychoclabwinston 5 жыл бұрын
Reason why it was off because they shut it off to take the manometer fitting out, ran across this a few times on new installs. I still take the pressures to make sure they actually fired it.
@puretoronto
@puretoronto 5 жыл бұрын
So the installer never even tested the furnace after install? How do you put in equipment, and leave without testing?
@Guillotines_For_Globalists
@Guillotines_For_Globalists 5 жыл бұрын
Why is it that these high efficiency furnaces do not need an air filter for the combustion intake? I am curious. Also have you ever heard an inducer motor that occasionally has a bit of a noise to it, like there's something very small bouncing around inside? We had our new furnace and A/C installed in late June. Been using heat now for a few weeks, works great! But if I put my ear up really close to the furnace I can sometimes hear something in there. Hard to tell what exactly since it is so quiet, but I can hear something.
@Valeij221
@Valeij221 2 жыл бұрын
You can have visible tape on your units? Our company’s told us electric companies mark it down and we have to cover tape or not use it.
@pineychristian
@pineychristian 5 жыл бұрын
Every install should get a full combustion analysis , set gas pressure , temp rise test and check / set blower speed. That ends issue with new installs. You print and staple copy of combustion analysis to customer invoice so its a legal document showing how you left furnace after install. Plus if you dont fire that thing first time customer does smokes out house and smell customer freaks out thinking something is seriously wrong with a brand new furnace..
@roberttrains
@roberttrains 5 жыл бұрын
Maybe it is time for some paperwork for your installs. Thinking of a check list they fill out per job. they might hate it for a couple of weeks but it might slow your call backs for these simple mistakes.
@rocketrider1405
@rocketrider1405 5 жыл бұрын
or even a smartphone app with a checklist that when completed can be emailed to the customer
@cdarrell1985
@cdarrell1985 5 жыл бұрын
You can give them all the checklists and paperwork you want, but that wont make a careless installer who doesn't take pride in his work, suddenly start caring.
@ZacherYT
@ZacherYT 5 жыл бұрын
Still strange to see the furnace in the attic! :) in Basements for us canucks.
@jaybrooks1098
@jaybrooks1098 4 жыл бұрын
I know what you need to send as a Christmas gift to that installer.
@bigstepper2235
@bigstepper2235 3 жыл бұрын
are you worth more in the field if you know installation and service side of the trade?
@proudlysig3934
@proudlysig3934 4 жыл бұрын
Really dig the videos man question why don't you guys snorkel the flu pipes we here in va We cut them about a inch away from the wall and 90 up and 90 out just wondering
@LuxAudio389
@LuxAudio389 Жыл бұрын
Yup that installer knows the run cap bandit too.
@billyrichverygoodcoverever2717
@billyrichverygoodcoverever2717 9 ай бұрын
This careless whisper drives me nuts, I like Ted anyway!
@douro20
@douro20 4 жыл бұрын
Why would they have gas furnaces and electric water heaters? A bit odd that the air check tubing in those furnaces is square...
@Rezcat-y6r
@Rezcat-y6r 5 жыл бұрын
Time for a company meeting, Ted!
@gregmccarthy6011
@gregmccarthy6011 5 жыл бұрын
i run unit from stat before leaving. allows me to sleep at night
@linejumper9741
@linejumper9741 5 жыл бұрын
Hacky looking install jobs. Tell your boys to clean it up .
@Kman-hw9pf
@Kman-hw9pf 4 жыл бұрын
Is Trane still making the XR series furnaces? Or is the S series furnaces the only choice now?
@alex-sv8to
@alex-sv8to 2 жыл бұрын
Those heat calls for new units with the gas valve off tells me they were not run during an install inspection. I find this disturbing because of any install issues or defects that could have been present. I also have to question if gas pressure and flow was checked. I am sure not. I would not be as kind as you when encountering some of these issues that you do.
@ares3914
@ares3914 5 жыл бұрын
I see on the second call the drain on the coil gor the a/c is hooked up on the secondary and the primary is plugged. You'll be back to service that install again in the spring. That's a weak installer and may be still green. You'll need to get rid of him or have someone watch his install
@waltradcliffe4482
@waltradcliffe4482 5 жыл бұрын
I am in auto repair had a guy forget to put the castle nuts on the ball joints because he was always on his phone lucky for me I had to raise it up to put a wheel liner in and heard the clunk every week it was something lost or broke or he didn’t show up when I was the busiest I was jeopardizing my business and house with this guy & had to let him go I went back to a one man operation now if something is wrong it is on me also I don’t have all the paperwork that is involved with employees.
@TheWoodman064
@TheWoodman064 5 жыл бұрын
I may not be perfect but at a minimal I would have changed that rusty galvanized pipe for a new one but most definitely I would have test fired before ever leaving and have left the switches on!
@richardsnyder3900
@richardsnyder3900 5 жыл бұрын
Pipe is black iron not galvanized
@TheWoodman064
@TheWoodman064 4 жыл бұрын
@@richardsnyder3900 I am talking about the one directly above the gas valve! It just does not look good in a new install and I would have changed it!
@malcolmshvac6692
@malcolmshvac6692 5 жыл бұрын
Gotta ask is copper legal for natural gas in SC?
@mykalimba
@mykalimba 4 жыл бұрын
At 1:19, it looks like there is a screw missing where the large circular piece (fan shroud?) is mounted. Right around the 12 o'clock position on the shroud, just below and left of the rightmost yellow nub.
@twopumpsandimdone309
@twopumpsandimdone309 5 жыл бұрын
Ever go to a service call after an install to find an installer error, and the homeowner wants compensation?
@Sixta16
@Sixta16 5 жыл бұрын
The compensation they get is the free warranty call like this already.
@phoenixhvac-r828
@phoenixhvac-r828 5 жыл бұрын
I've been there, it use to bother me, now i just turn it around on them and tell them that I'll be waiving the service charge for them.
@w.miller7282
@w.miller7282 4 жыл бұрын
I noticed the electric water heaters too, idk why they aren’t gas since the house obviously has it.
@HVACRNorth
@HVACRNorth 5 жыл бұрын
Cool vid...heating season begins...back charge then lol👍up here ABS Flue is against code.
@tim2269
@tim2269 4 жыл бұрын
Do they all make that low electric hum when not running?
@EluderRacing
@EluderRacing Жыл бұрын
I have a hard time believing these calls are you saying these guys are not testing firing these units before they leave the job? how is a job considered done and signed off on without running the unit???
@theloweshow3047
@theloweshow3047 5 жыл бұрын
no equipment test, or run through? did they even sniff/test the gas!?
@Cody-ye3ye
@Cody-ye3ye 4 жыл бұрын
U don’t have your installers run the furnaces and check pressures?
@jburr36
@jburr36 5 жыл бұрын
looks like a coaching opportunity for your installers
@FrostBlueFire
@FrostBlueFire 5 жыл бұрын
Someone is gonna get a tongue lashin'
@luisaleman4008
@luisaleman4008 4 жыл бұрын
Aren't your installers suppose to test ac and heat while they finish with the installation? The company I work for we do that, plus theirs final inspection by a technician like 3 days later to check pressures and adjusted the gas valve also static pressure
@watermanone7567
@watermanone7567 5 жыл бұрын
Easy and good fix. Do you back charge the installers for their mistakes? Thanks for the video.
@mikejones-ku5ix
@mikejones-ku5ix 5 жыл бұрын
Do you get back charged for your mistakes at work??? I bet you have cost a company money in wasted time or mistakes, payroll deduction time for all of us.
@titovazquez589
@titovazquez589 2 жыл бұрын
I saw a big mistake and no one commented on it. They used copper pipe for the gas and the copper causes a chemical reaction that damages the parts of the heater. so mr cook a husted also needs to update
@AdamWBush
@AdamWBush 5 жыл бұрын
At 5:14 secondary drain is plugged with a non-threaded blue cap that is not designed to be water tight might be back for a water leak next summer good luck
@bkoz319
@bkoz319 5 жыл бұрын
9:41 baller!!!!
@maranlou2542
@maranlou2542 5 жыл бұрын
Dude don’t wanna leave nice crawl space! 🤣🤣🤣
@jacklynn6164
@jacklynn6164 3 жыл бұрын
pretty sad. dont they have to start and check after the installation? after 40 years in the trade i dont remember this ever happening. we had times something would not come on but not from something this bad
@claypyrotech7473
@claypyrotech7473 5 жыл бұрын
So they didn't test it when it was installed. The company that installed my new AC and Furnace they tested both 3 times.
@HVACingMyWay
@HVACingMyWay 5 жыл бұрын
I’ve been installing trane for awhile now and that’s the first time I’ve ever seen a single stage s9
@TunedOut4Ever
@TunedOut4Ever 5 жыл бұрын
Hi! I love to watch your videos and love learning all about the trade! I have a question for you! I have photos to show it, but my brand new single stage 5-Ton American Standard/ 85% Furnace A-Coil cabinets sweats tremendously! House is 2455 Sq Ft, built in 2003 and the old Lennox system sweat, but not as bad. The furnace sits in a cabinet inside, but has attic ducts to allow air to pass in for the furnace. On top of all that, the unit has a bit of a vibration to it. Random things rattle like the garage door and some picture frames. Very subtle, but it is audible. Thoughts? Lol
@patrickr412
@patrickr412 5 жыл бұрын
The problem is its 5 ton. the designer should have put 2 separate 2.5 ton systems in to zone the house this always is a better option. 5 ton is basically commercial and it needs huge huge ductwork to prevent equipment air starvation that leads to vibrating and over cooling and sweating which I'd garuntee in a 2500sqft home they definitely didn't design the ductwork correctly for 5 ton. A remedy for sweating would be to wrap the duct that's sweating tightly and thoroughly in R8 duct insulation wrap and ul rated silver insultape to seal it off from the ambient air around it. But I'd get a professional to consultate with you in person about whether or not the ductwork can properly support that 5ton
@TeemarkConvair
@TeemarkConvair 2 жыл бұрын
the last one, the "warranty" job: do the installers not check ALL the functions after the install? unfortunately your having to be called out gives your company a bad name regardless of the cause.
@rocker8692
@rocker8692 4 жыл бұрын
I might have to come up there.Im in Florida now.
@Jeff_S...
@Jeff_S... 5 жыл бұрын
I'm a tech, but I get sent out in a crunch, time to time, to do quick one man changeouts. I just couldn't see not starting it up to make sure it was running right. Nothing worse than a callback.
@Mrflash222006
@Mrflash222006 5 жыл бұрын
Turned off after commissioning ? I take it gas and burner pressures have to be taken for the paperwork
@its_bob_from_accounting801
@its_bob_from_accounting801 5 жыл бұрын
how are you guys passing inspection without having at least 18" of straight flue pipe off the inducer before a 90 ell ?
@kenthomas4668
@kenthomas4668 5 жыл бұрын
because it's impossible in that crawlspace
@JohnstonPettigrew
@JohnstonPettigrew 5 жыл бұрын
The installers we're anti diy too........and where was the premium test run?
@greg778123
@greg778123 5 жыл бұрын
Love your videos but wish you would make audio a little louder
@I.C.E908
@I.C.E908 4 жыл бұрын
I don’t know a lot about furnaces but I do know some stuff. One thing I know is the new furnaces are crap! There cheaply made and barely last 10 years. A balloon can last longer than these things. I have a very old furnace from the 1940’s it still works and it works like a charm!
@danomite359
@danomite359 2 ай бұрын
This is NOT going to be any fun! -- LOL I love this guy. He's me.
@force311999
@force311999 3 жыл бұрын
at 0:25 sec. do I see the pvc vent has a gap were it needs a coupling
@RichardMyers-gx5fw
@RichardMyers-gx5fw 5 жыл бұрын
The gas nipple looks pretty bad, rust?
@dannyp3652
@dannyp3652 5 жыл бұрын
done see the point of off/on switch on gas valves , we test ours system on both modes it does t matter how hot it is
@dannyp3652
@dannyp3652 5 жыл бұрын
*dont
@antoniosantiago2770
@antoniosantiago2770 5 жыл бұрын
How many installs a week. How much you pay service tech.
No Heat S9V2 Gas Furnace simple fix
10:08
Anti DIY HVAC
Рет қаралды 44 М.
Yearly Furnace Cleaning And Maintenance Pro Tips
8:56
Everyday Home Repairs
Рет қаралды 1,1 МЛН
Will A Basketball Boat Hold My Weight?
00:30
MrBeast
Рет қаралды 124 МЛН
🕊️Valera🕊️
00:34
DO$HIK
Рет қаралды 16 МЛН
Smart Sigma Kid #funny #sigma
00:14
CRAZY GREAPA
Рет қаралды 86 МЛН
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 11 МЛН
Replacing Your Gas Furnace Is Easier Than You'd Think.
58:23
The DIY HVAC Guy
Рет қаралды 337 М.
Easter Egg in Furnace ? ICP Comfortmaker Gas Induced Draft Fail
31:20
Top 5 Furnace Problems and How to Fix Them
20:07
Word of Advice TV
Рет қаралды 1,4 МЛН
Installation of New Carrier Furnace and Ductwork in an Attic
7:27
Albert Air Inc.
Рет қаралды 2,8 М.
Old TRANE Gas Furnace repair
36:31
Anti DIY HVAC
Рет қаралды 21 М.
The Most Common Reason Why A Gas Furnace Won't Turn On
8:25
Everyday Home Repairs
Рет қаралды 1,7 МЛН
I Should’ve Known BETTER…| HVAC Install
13:05
Quality HVACR
Рет қаралды 302 М.
Goodman Gas Furnace failed
31:46
Anti DIY HVAC
Рет қаралды 43 М.
How To Replace your Furnace and AC Yourself | iDIY |
37:11
Centennial Renovation
Рет қаралды 36 М.
Will A Basketball Boat Hold My Weight?
00:30
MrBeast
Рет қаралды 124 МЛН