New microscope lenses: longer working distance!

  Рет қаралды 1,349

Curious Scientist

Curious Scientist

Күн бұрын

In this video, I briefly show you the new lenses I got for my microscope. They will make my work easier, especially when I work with chips and transistors whose silicon dies are sitting in a small dimple.
Join my channel membership: / @curiousscientist
Relevant article: curiousscienti...
Silicon dies: curiousscienti...
Parts and tools: curiousscienti...

Пікірлер: 3
@mateuszbogusawski7649
@mateuszbogusawski7649 6 ай бұрын
your microscope system is 160mm tube length, and new objectives are infinity (if I see it correctly) you should use some tube lens with correct value. That's why the working distance is off, with the correct tube lens you will get much better results. Nice video
@CuriousScientist
@CuriousScientist 6 ай бұрын
Wow, thank you very much! You answered the question in the video within like 5-10 minutes after I published it. 😎I had a feeling that it has something to do with the tube, but due to the lack of my knowledge on these systems, I could not really point out what's wrong. I will look up these tube lens and if it is not a huge investment, I might get one in the future. Thank you once again!
@-VK2NP
@-VK2NP 6 ай бұрын
Just to add an infinity microscope has an extra lens either in the tube or head , hope you sought it or just sell the 2x and buy one for a 160mm tube length, the 20x looks ok
DIY Scanning Laser Microscope
22:05
Breaking Taps
Рет қаралды 444 М.
The Numitron: An obvious idea that wasn't very bright
23:21
Technology Connections
Рет қаралды 1,6 МЛН
Cape Coral, Florida Fire Department rescues alligator stuck in storm drain
00:30
NERF TIMBITS BLASTER
00:39
MacDannyGun
Рет қаралды 14 МЛН
Шаурма с сюрпризом
00:16
Новостной Гусь
Рет қаралды 6 МЛН
🔬 10 Things I wish I knew when I started Microscopy as a Hobby
14:25
Microbehunter Microscopy
Рет қаралды 115 М.
How to Make a Real Diamond - (Not Clickbait)
8:51
JerryRigEverything
Рет қаралды 6 МЛН
Why a 3000x microscope magnification does not make sense!
9:47
Microbehunter
Рет қаралды 285 М.
🔬Microscope objectives explained
34:02
Microbehunter Microscopy
Рет қаралды 36 М.
I tried to make a camera sensor
30:00
Breaking Taps
Рет қаралды 1,1 МЛН
Adam Savage's New Digital Microscope!
21:37
Adam Savage’s Tested
Рет қаралды 188 М.
The "Impossible Torpedo" was real
16:33
Steve Mould
Рет қаралды 1,7 МЛН
Cape Coral, Florida Fire Department rescues alligator stuck in storm drain
00:30