No A/C Service Call That I Will Not Forget | HVAC

  Рет қаралды 4,577

AB HVAC

AB HVAC

27 күн бұрын

I did what I could to try and get these people going. I had no idea what was really going on, and i was so exhausted that I began second-guessing myself. Tried to remember the basics and keep going forward, I think I got the right diagnosis.
#hvacmaintenance #hvac #hvaclife #hvacrepair #bluecollar #techlife #airconditioner #fieldpiece #servicetechnician #attics #controlboard #transformer #exhausted #voltage

Пікірлер: 66
@RobertTuck-vo8cw
@RobertTuck-vo8cw 24 күн бұрын
I always check for VAC across the incoming wires. Also you violated code and safety by using the ground for a neutral return. If a problem develops in the ground and it opens - the entire indoor unit can become energized to 120VAC due to the back feed from the hot wire. Since you had a hot and neutral wire problem, it is entirely possible to have a ground problem arise. (I know that you did it to get them by)
@ccthepope
@ccthepope 24 күн бұрын
No, You were perfectly correct in saying. "Thank you Jesus" at the end of the video! I have worked field service for 46 years and when I gave thanks for finally getting the answers I need, I got more help in the future. FYI, this also works in all my life's troubles. (I am now 69 years old).
@joshr2828
@joshr2828 25 күн бұрын
Stupid and accomplished at the same time 😂 glad to know that I’m not the only one out here! Great work man!
@robinsymonds5353
@robinsymonds5353 23 күн бұрын
You ain't stupid bro you're a professional
@FernandoGarcia-lv3mj
@FernandoGarcia-lv3mj 16 күн бұрын
To me happen almost same thing,with carrier furnace , couple models have a safety it working with ac and heat crazy rigth, have power on all the unit except on comun and red almost make me crazy. Call a experience technician and he told me cheq for rollout and presure switch and guess what a freaky roll switch wasent work that wy dont have 24 volt on my slot for thermostat 😅😅😅😅 they conected in secuency for the whole unit and go back to 24v on the board.
@sbnatomicrecords
@sbnatomicrecords 25 күн бұрын
I feel you champ. It's happens In this hvac field. On Wednesday everything went wrong and was second guessing myself. Making rookie mistakes 😂
@user-bh8no8wn8z
@user-bh8no8wn8z 11 күн бұрын
I would have check from hot to neutral if ok,then it's inside the air handler
@patrickbell4687
@patrickbell4687 25 күн бұрын
A good self-assessment of your work isn't a bad thing. Every call is a learning experience. Good job AB!! Enjoy the weekend. 😊
@ELITECLIMATESOLUTIONS
@ELITECLIMATESOLUTIONS 24 күн бұрын
Hey buddy I used to live in Conyers GA. right off of 20, and worked for a company called Reliance heating and air, I've been in those attics in the middle of July and that shit ain't no joke!!!!! the heat coming of the sun is unlike anything I have ever felt before you can feel your skin cooking!!! anyway I moved back north to southeastern MI GOD BLESS YOU BROTHER
@MoonRambo702
@MoonRambo702 25 күн бұрын
Sounds like u lost the neutral. I always check the hot and neutral for 120, instead of only hot to ground, because that only tells 1/2 of the story.
@AB_HVAC
@AB_HVAC 25 күн бұрын
Yeah, lesson learned
@daviddunn9898
@daviddunn9898 25 күн бұрын
I like your video I would slow down and explain exactly what you did I have learned a lot watching Keep up the good work
@spenceryelinek4313
@spenceryelinek4313 21 күн бұрын
I know the feeling, brother. I've been doing this for 5 years and still have calls like this. Working long hours and in the heat, you can't always think straight.
@jkmarshall3553
@jkmarshall3553 25 күн бұрын
Great job getting that unit up and working! Enjoy your weekend!
@AB_HVAC
@AB_HVAC 25 күн бұрын
You too!! Thanks for watching!!
@AaronPowellvox
@AaronPowellvox 25 күн бұрын
Great work man.
@tonymartin9271
@tonymartin9271 24 күн бұрын
Been there done that! I know the feeling when you finally get it working. Good job keeping with it until the end. Mama aint raise no quitter !
@AB_HVAC
@AB_HVAC 24 күн бұрын
Ya gosh darn right!!!
@stevencarrillo3615
@stevencarrillo3615 25 күн бұрын
I would have done the same as you did and I did learn something new thanks
@AB_HVAC
@AB_HVAC 25 күн бұрын
Man I hate the way I left the wire but we will go back out and tidy it up
@stevekaniaris829
@stevekaniaris829 23 күн бұрын
Watched a few of your videos, fun watches. Old tech here., Remember from school and keep to this day. LINE, CONTROL, LOAD, RETURN. Have a good weekend.
@gordonpotts753
@gordonpotts753 24 күн бұрын
When ur in an attic like that it's very hard. Take breaks. Lol.lol. I luv ur attitude.
@justwork_hvac
@justwork_hvac 25 күн бұрын
Have a great weekend brother 🤟💯🌎
@redneckways1617
@redneckways1617 24 күн бұрын
That has happened to every tech…if you get to the point of exhaustion then EVERYTHING seems to go backwards…
@RepairProTrepreneur
@RepairProTrepreneur 17 күн бұрын
Hi bro, Great job!. I think it was a loose neutral wire in the circuit. Check in the switch box and all neutral wire connections.
@AB_HVAC
@AB_HVAC 17 күн бұрын
Well the weird thing about it was the hot leg in that wiring from the switch to the furnace had no more continuity. I found a few staples it was crushed by but I couldn't find a conceise break. It was so confusing that's why I ran a new wire. Just mad I only had 8gauge with me 🙃
@lifecycles6791
@lifecycles6791 17 күн бұрын
Great job
@DennisBuckley-yd6cl
@DennisBuckley-yd6cl 22 күн бұрын
Yeah always check from the hot leg to neural. I like a meter that has a LOZ setting for ghost voltage also when checking A/C Voltage.
@coastalcarolinarocks
@coastalcarolinarocks 24 күн бұрын
I always check on furnace boards from hot to actual neutral. I’ve had skewered readings from reading to ground before and it’s got me all messed up
@coastalcarolinarocks
@coastalcarolinarocks 24 күн бұрын
Just finished the video, good job lol. Remember with transformers and 120v, common and neutral are literally grounded. What that does is on the 24v side it no wires are grounded, each wire will have around 12v, once you ground one of them that one becomes the common and the other one becomes hot 24v. Same with 120 applications. Stay hydrated brother
@ramonestrada38
@ramonestrada38 23 күн бұрын
Hope you go back and remove the code violation (neutral to frame ground) which it is unsafe for other techs and residents if the ground ever opens. I'm an industrial electrician of 40 some year's and this won't be your first and last head ache. Been there several times through out my career. You can never stop learning because electricity is like an open story book with no ending. Keep up the good work and keep those videos coming.👍
@TimS-wy8mj8yw4c
@TimS-wy8mj8yw4c 24 күн бұрын
I used to use a small wire tie and jam it in the switch and its frame.
@jonnyaasen1018
@jonnyaasen1018 13 күн бұрын
Do do do do do
@markcotter2355
@markcotter2355 22 күн бұрын
Like to see you trying to learn. Your Neutral wire is lost or broken to the furnace. Need electrical work. Should always check voltages from common to power or power to power. Never line one to ground. Transformer was not bad.
@AB_HVAC
@AB_HVAC 22 күн бұрын
Yeah, I think I said that at the end of the video. But that was the first time I came across that. It was so weird
@404aladdin9
@404aladdin9 20 күн бұрын
I always use common never use the cabinet for ground
@chrisscott1547
@chrisscott1547 24 күн бұрын
Don't rely on chassis for 120/240 measurements. Also, sometimes the 24 vac common is not connected to chassis.
@meridianline7291
@meridianline7291 24 күн бұрын
I had almost the same issue except the voltage side was blowing not incoming power issue. Low voltage fuse was not blown
@AB_HVAC
@AB_HVAC 24 күн бұрын
Man, it's the fun part about the job tho
@daftydirtybird6940
@daftydirtybird6940 25 күн бұрын
I had to watch this a couple times. So your nuetral on your board wasnt grounded properly and was recieving less voltage overall, so you connected it to a grounding screw and got the correct voltage.
@AB_HVAC
@AB_HVAC 23 күн бұрын
Correct
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd 25 күн бұрын
So I got a call on a 100% OA unit today. Water leak on ceiling tile, 2nd time, I’m #2 on this call. Get to site, do a visual on roof. Notice refrig flashing in sight glass both compressors running. Hear belt squeaking, open panel and belt spinning faster than pulley😂😂. Head back down, pop ceiling tile, notice there’s a return in ceiling. 24 x 24 Eggcrate return is plugged. 4000 cfm with about 85% fully plugged. So, not 100% OA unit after all. Bottom of OA unit has heavy sweat, which is dripping on ceiling tile. So I get up on a ladder, turn flashlight off and notice sunlight coming in all 4 sides of curb. Fix, clean RA grille, spray foamed gaps to seal curb, change belt, add refrigerant, fill sight glass. Unit no longer sweating on bottom side. 5 hours. Just my day. It is hot. I’m in AL. So my prognosis, lack of return air, loose belt, under charged refrig level, no load on coil, coil got very cold, outside air through curb infiltration, dewpoint issue on bottom side of curb metal plates from all of the fore mentioned and wa-la, rain on the ceiling tile. Nice vid A.
@AB_HVAC
@AB_HVAC 25 күн бұрын
Man that sounded like a poop show
@rafaelandreano
@rafaelandreano 24 күн бұрын
Did you do a leak search to rule out possible leak ?
@MetalDetectingwithCZkidd
@MetalDetectingwithCZkidd 24 күн бұрын
@@rafaelandreano no leak search.
@robinsymonds5353
@robinsymonds5353 23 күн бұрын
I work on a circuit that kept breaking down under load
@Hvacnc
@Hvacnc 25 күн бұрын
That would’ve got me too. Just always check all legs to a ground screw
@AB_HVAC
@AB_HVAC 25 күн бұрын
Well that's the thing, to ground on the frame, where the ground screw was connected I would get 120, but from the hot leg for transformer to neutral on board I was getting 102. Idk why it was doing that but it was just 🤯
@bobshanery5152
@bobshanery5152 25 күн бұрын
@@AB_HVAC There is an issue with the grounding system or a potential fault in the electrical circuit. There could be voltage drop or resistance in the circuit between the transformer and the board. It could be a loose connection somewhere or some damaged wiring rubbing on something. My guess would be something loose and the vibration from the unit over time finished the job. It can create high resistance. Let us know when you go back if you find it. I'm curious.
@frankevans588
@frankevans588 23 күн бұрын
It happens to us all brother...
@AB_HVAC
@AB_HVAC 23 күн бұрын
Thanks for the understanding 🙏🏽
@edwardsoto7379
@edwardsoto7379 19 күн бұрын
You do a good job always. however you need to learn a bit more about how electricity works. Other than that, good job.
@jrsmyth9761
@jrsmyth9761 22 күн бұрын
DON"T check to ground!!! Check to neutral. Did you put the original transformer back in?
@AB_HVAC
@AB_HVAC 22 күн бұрын
I didn't at the time but I didn't throw it away, it's still up there
@AaronPowellvox
@AaronPowellvox 25 күн бұрын
Those switches sometimes get hot and crack causing the power to not go through them. Sometimes if you jiggle the switch it will turn on intermittently. Then you can just replace it. I haven’t finished watching so I’ll see what your conclusion is.
@AB_HVAC
@AB_HVAC 25 күн бұрын
I have never had that weird of a grounding issue before. Normally if I do, it's like a grounding issue causing the flame rod to not read correctly during heat mode
@chrisscott1547
@chrisscott1547 24 күн бұрын
Austin, in this stage of your career, you are doing great. Keep learning all you can. Sometimes when something appears to have two or more unrelated problems, and the unit has worked recently, you gotta ask yourself "what is the likelyhood of these two things failing at the same time?"
@Djcarp83
@Djcarp83 19 күн бұрын
Stop testing to ground test to the other side of the neutral. We got a test for return voltage lost common.
@hvacwonders7081
@hvacwonders7081 Күн бұрын
Why don’t you just chill out and give the man a break he is doing exactly what we have all done in the field he’s still learning and he’s doing a pretty damn good job at it to he’s also got the balls to post his mistakes which I am most impressed and respected by but where’s your videos…??
@hvacwonders7081
@hvacwonders7081 Күн бұрын
Everyone has ran into this type of situation that he has most just don’t have the balls to post it on social media..
@sofalvr
@sofalvr 22 күн бұрын
I never tape the door switch. I just cut out the door switch and wire nut the leads. I knew you were checking the ground wrong but you figured it out. As long as you learned that's all that counts.
@tss212
@tss212 23 күн бұрын
Backstabbed switch
@robertcherry4971
@robertcherry4971 23 күн бұрын
So now you are returning voltage through ground instead of neutral….LOL
@AB_HVAC
@AB_HVAC 23 күн бұрын
So now I'm giving people AC
@rc51price
@rc51price 18 күн бұрын
30 years and counting for me. You are making the same mistakes we have all made. Learn from it and move on.
@Dmcbigboy8687
@Dmcbigboy8687 23 күн бұрын
Seems like a bad switch. Falling intermittently.
Service Call: Following another company!
35:09
HughesMan HVAC
Рет қаралды 14 М.
HVAC No Cooling Service Call WORST HELICOPTER EVER !!
22:15
Anti DIY HVAC
Рет қаралды 288 М.
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 37 МЛН
CHOCKY MILK.. 🤣 #shorts
00:20
Savage Vlogs
Рет қаралды 15 МЛН
Ouch.. 🤕
00:30
Celine & Michiel
Рет қаралды 26 МЛН
It DOESNT always go as planned | HVAC | repairs, estimates and follow ups
16:26
Koolin’ with Krauss HVAC
Рет қаралды 3,7 М.
HVAC Service Calls | Rescuing Few Very Old Air Conditioners
18:28
HVAC Scam failed again on 2nd opinion call
18:59
Anti DIY HVAC
Рет қаралды 135 М.
Traveled 7 HOURS for a Service Call...
13:41
Quality HVACR
Рет қаралды 18 М.
Home Maintaining 80° During Heat Wave | HVAC
22:14
AB HVAC
Рет қаралды 3,2 М.
1 BIG MISTAKE All DUCTLESS Owners Make!
6:25
HVAC Guide for Homeowners
Рет қаралды 28 М.
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,2 МЛН
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 37 МЛН