NORA Video 6, Cad Cell Relays

  Рет қаралды 69,295

National Oilheat Research Alliance Videos

National Oilheat Research Alliance Videos

Күн бұрын

Пікірлер: 12
@davidmcleandamrecordings3673
@davidmcleandamrecordings3673 3 жыл бұрын
Thanks.. you saved me hundreds and made me warm.
@katinasandoval5251
@katinasandoval5251 24 күн бұрын
Great video thanks!
@l.a.m7645
@l.a.m7645 Жыл бұрын
Now we have Beckett Genisys/Carlin Pro max cad cell relays.
@ronsbeerreviewstools4361
@ronsbeerreviewstools4361 7 жыл бұрын
This is a very Good educational video.
@dave4854
@dave4854 7 жыл бұрын
it looks to me like you forgot one wire, the other black wire from the transformer, I believe it goes to all the white(neutral) wires.
@peterrebic4436
@peterrebic4436 5 жыл бұрын
actually if u fire up burner then remove F n F wires and place a jumper acroos F n F and the burner continues to run u hav a bad cad cell..this is in regards to the 1.5 resitor there speaking of,,,in other words u think the cell is bad..light off burner remove FF place jumper at FF terminals..If burner now stays lit replace cad cell and holder assy aswell..Pete da Boilerman NYC
@coyotejoe80
@coyotejoe80 4 жыл бұрын
That's often true. I've seen boilers where someone put the wrong nozzle in and it won't see. I've also seen soot donuts on the head that won't let the cad eye read. I've seen oil burners where someone cut out sections out of the static plate because it wouldn't see. Usually they had the wrong nozzle or they messed with the head setting and had a shitty flame.
@philipfm
@philipfm 10 жыл бұрын
very good info. thanks for posting
@henryperez5404
@henryperez5404 4 жыл бұрын
Good thory need it for troubleshooting
@tomyang7788
@tomyang7788 10 жыл бұрын
at 7:56, how is it possible that removing one lead from the F terminal can cause the control to energize ?
@muzammalbaig
@muzammalbaig Жыл бұрын
Removing the wire makes the control think there is no flame hence it energizes to cause a fire but then it locks out as there will be no fire detected given the wire has been removed.
NORA Video 5, Primary Controls, Part 1
24:28
National Oilheat Research Alliance Videos
Рет қаралды 16 М.
Oil Burner Primary Control and CAD Cell Operation and Troubleshooting!
11:13
AC Service Tech LLC
Рет қаралды 195 М.
This Game Is Wild...
00:19
MrBeast
Рет қаралды 187 МЛН
Ice Cream or Surprise Trip Around the World?
00:31
Hungry FAM
Рет қаралды 22 МЛН
Eiva林麗謙 - 不嚮往詩和遠方【Official Lyric Video】
5:14
Eiva Qian 林麗謙
Рет қаралды 182
NORA Video 1, Action Response to a No Heat Call
22:39
National Oilheat Research Alliance Videos
Рет қаралды 22 М.
90340 HVAC Relay - NEED TO KNOW INFO
19:31
John Jennings
Рет қаралды 69 М.
NORA Video 13, Combustion Efficiency Testing
15:06
National Oilheat Research Alliance Videos
Рет қаралды 13 М.
Oil Burner Primary Controls- A more in depth look
44:41
Tony Saccavino-HVAC Instructor
Рет қаралды 3,8 М.
beckett oil burner making explosion noise when starting
20:03
steven lavimoniere
Рет қаралды 173 М.
How To test a cad cell and the primary control on an oil burner.
8:00
Scott Taylor (TayloredSteam)
Рет қаралды 24 М.
HVAC Relays 101 3D
13:30
HVAC School
Рет қаралды 31 М.
NORA Video 2, Preventative Maintenance, Tune-Up
21:50
National Oilheat Research Alliance Videos
Рет қаралды 47 М.
Oil furnace troubleshoot part 2 No flame
11:47
grayfurnaceman
Рет қаралды 892 М.
This Game Is Wild...
00:19
MrBeast
Рет қаралды 187 МЛН