you are the best instructor ever thanks for your help, I think I may be able to tackle it.
@grayfurnaceman11 ай бұрын
Go for it. GFM
@hanniballecktah110 жыл бұрын
Thanks for the very informative videos on trouble shooting oil furnaces, I went through every step on trouble shooting and learned my way around it, I ran my oil tank low, and had to clear out the sludge out of the line, I did it with an air pump, now I just have to install a new firomatic safety valve in the morning and hopefully my furnace will be good to go.
@bartholomewmerrick533010 жыл бұрын
thanks for all the videos, so helpful narrowing down the issues
@andysmechanical782511 жыл бұрын
Thanks for all of your videos Grey! I watch a lot of them, sorry just a comment slacker. Thanks again for your time and hard work making your videos.
@grayfurnaceman11 жыл бұрын
Thanks for the support. GFM
@BenCough-xr8nb10 ай бұрын
Very helpful, great details and saved my a**!
@dpeagles11 жыл бұрын
Since I worked in a city, oil furnaces were uncommon. Seemed 75% of the time, they never serviced the filter/nozzle and continously let it run out of oil. Most were in rental properties in bad areas. A real joy to work on in a 20" crawlspace. Oh, and a tank that was 35 years old and corroded................talk about dread.
@graycomputerman594611 жыл бұрын
There are 2 types of oil furnaces. Those that are serviced every year and on keep filled service, and those that are only serviced when they fail. Guess which ones had the most emergency service. Some of the furnaces I serviced every year were installed in the fifties and were still going strong in the 90s. Thanks for the comment. GFM
@Brad123720211 жыл бұрын
Great informational video. Thanks GFM!
@Doggfan3 жыл бұрын
Thanks for these videos
@General5USA Жыл бұрын
Don’t forget to remove the nozzle ( which should have been done when inspecting the ignition electrodes) to clean the filter that is on it. Verrrrry important. The nozzle metal screen filter and the filter in the pump is probably more proned to obstruction dirt than any of the other filters because the filter out dirt and debris more finer than the primary tank filter
@palangnar3588 Жыл бұрын
Thank you for all your videos, can you tell me which oil filter style you think is better to use Cartridge type or turn type K10, assembly, i see many older places have cartridge type, what do you prefer ?
@phcapprentice754410 жыл бұрын
Good video series GFM. Thanks for this one and the rest of 'em!
@ldr42783 жыл бұрын
Gray Furnaceman : would you answer a question or two please ? I was up all last night 05/30/2021 because the symptoms were what was described in your video. Oil burner would turn on then off then on again as if there was air in the lines or maybe a clogged nozzle. So I changed filter and nozzle, checked pump screen and then I could not get oil burner pump to fill up filter canister - I could not get oil to the burner. Pulled small copper fuel line that supplies oil to tube that has nozzle attached to it, has ceramic electrodes proper terminology escapes me at the moment, the gun I believe it is called(that has nozzle screwed into). Well, no oil was coming out of fuel line. Oil tank is piped with two pipes and not gravity fed. Fuel lines are coming out of the top of oil tank. I thought fuel lines were clogged so I got air compressor and blew the lines back to the oil tank. Approximately 100 lbs of pressure was used. I do not know how I finally got oil burner to run again but I did. Original symptoms are still happening. Fires up for a little then flutters then off and eventually during the same cycle burner turns back on (thank God)before lock out. I have a Suntec A2VA-7116 oil pump. The oil pump makes a squeek sometimes when it first starts up then the squeek goes away. I do use fuel additive when the Oil delivery man delivers the oil. This is like my third pump so far. The last oil pump I installed was 12/2019. Any help you could offer would be appreciated.
@littlebro78392 жыл бұрын
Did you ever figure out the problem?
@petropsaroudis2384 Жыл бұрын
This was made 10 years ago and the camera is 10x better than most smart phones today 😅
@RobHVAC11 жыл бұрын
Great video.
@jregamey2 жыл бұрын
I got all drip feed style one. No power no pump. The control valve doesn't even fill up as much as it needs to even though the valve is full open. Is it the level? Or air bubble?
@thecurious67212 жыл бұрын
Thank you sir for very informative videos! I have one question, when I do smoke test every third sample is wet. Two tests show trace (0-1). co2-9.1, o2-8.6 Could you advise what it could be? Thanks.
@grayfurnaceman2 жыл бұрын
Any wet sample indicates unburned oil. You may have had an ignition failure and the combustion chamber has not burned the residual oil. You could also have a partially plugged nozzle. GFM
@thecurious67212 жыл бұрын
@@grayfurnaceman I see. Thank you so much! Wishing you all the best in new year!
@ontariohvac8 жыл бұрын
I know this is 2 years old, but, hoping you're still watching the comments, where did you put that gauge?
@grayfurnaceman8 жыл бұрын
It is placed on the inlet to the pump. Hope this helps. GFM
@geojor10 жыл бұрын
something for all of us to think about...
@jasonsmith67766 жыл бұрын
hey GFM,Just put in a new oil tank the burner ran for about 9 hours I turned it off tried it again and no oil flow to the burner.Could it be a blocked oil line bad pump or pump coupling.I just Replaced the pump,the motor,cad cell relay and igniter, at this point I'm wondering if the tank could of possibly tilted and no oil is even getting to the oil line to the burner
@grayfurnaceman6 жыл бұрын
You could have a blocked line or filter. I would remove the filter canister, the turn on the oil to see if oil is available. GFM
@jasonsmith67766 жыл бұрын
I'll give that a try thanks,I was leaning towards a blocked line but the filter could be the problem,I'm using the standard canister filter not sure when it was serviced last so I might just upgrade and get a renewable filter
@grayfurnaceman6 жыл бұрын
Sounds like a plan. GFM
@EseMorro6104 күн бұрын
Is there any chance that the nozzle might be plugged? I have a burner that oil comes out after I attach the oil line from the assembly and it does pump out, but still no fire? There is a good spark makes me think it could be the nozzle its self? Anyone ever come across that?
@grayfurnaceman3 күн бұрын
You could certainly have a plugged nozzle. GFM
@brianjones798311 жыл бұрын
What is the best way to unplug the line? Is it OK to try blowing it out with Nitrogen or compressed air?
@grayfurnaceman11 жыл бұрын
You can blow it out if both ends are open. When it is clear, reconnect and do a thorough flush. GFM
@JosephSedin4 ай бұрын
Furnace starts then shuts off after 30secs
@jimmy_Ross29 күн бұрын
i cant get my pump to work i never finnish high school and i figure all this out myself clearly you didnt help me out so thanks for nothing