High-voltage circuit breaker testing with OMICRON's CIBANO 500 and CB MC2

  Рет қаралды 79,953

OMICRONenergy

OMICRONenergy

Күн бұрын

Пікірлер: 16
@sunilkhandagale9966
@sunilkhandagale9966 3 жыл бұрын
Amazing,accuracy & ,safety enviroment work in this possible circuit breaker testing device
@surya-pc7nx
@surya-pc7nx 3 жыл бұрын
Thank to omicron for such innovative testing kits. While working at height it is recommended that wearing safety belt.
@shabirkhan6173
@shabirkhan6173 6 жыл бұрын
Leader in Testing electrical equipment and devices for measurement, well done OMICRON
@udeyraj1988
@udeyraj1988 12 жыл бұрын
Excellent video! you demonstrated clearly thanks!
@aurelhoxhaj6443
@aurelhoxhaj6443 6 жыл бұрын
what a great equipment. I have one question. how to connect the clamps in a CB with one interruption chamber? (where to connect the black clamp )
@omicronenergy
@omicronenergy 6 жыл бұрын
Dear aurel Hoxhaj, thank you for your words and the related interest in OMICRON and our products. With the MC2 we have the possibility to connect two interrupter chambers. This means, the MC2 has two current outputs and two voltage inputs. We just output e.g. 100A and measure back the voltage drop and hence calculate the resistance for the Dynamic Resistance Measurement or the Contact Resistance. If you have one interrupting chamber, you need to connect it the same way as for two, just - one clamp (red) on the circuit breaker contact and the other clamp (black) on an earth potential. Often we use just the housing or screws of the breaker, as this is in most cases earth potential. There you need to be careful, due to potential pollutions or coatings. But take care: The oil drain screw is often not on earth potential, avoid this place for the earth connection. For tricky connections we have got so called Y-clamps with a thorn to ensure a proper connection. If you have any further questions, please feel free to ask. Best regards, Your OMICRON team
@aurelhoxhaj6443
@aurelhoxhaj6443 6 жыл бұрын
for a Circuit breaker with one interrupting chamber, in the case of static resistance measurement the red clamp is connected in one terminal of the CB, and the black clamp in the other terminal of CB. (none of the terminals grounded) ? Thank you
@omicronenergy
@omicronenergy 6 жыл бұрын
Dear aurel Hoxaj, you’re right. For a one chamber breaker, you have the red clamp on the one hand side of the breaker and the black one of the other side. Just for the two interrupter chamber breakers we need the earth on the housing. Best regards, Your OMICRON team
@aurelhoxhaj6443
@aurelhoxhaj6443 6 жыл бұрын
one more thing. is it necessary to ground any of the terminals?
@omicronenergy
@omicronenergy 6 жыл бұрын
Hi aurel Hoxaj, Usually we ground on one side on HV breaker. The line side will be disconnected and with the earth breaker it’s grounded. Best regards, Your OMICRON team
@tune7254
@tune7254 9 жыл бұрын
Hi thanks for great video ! I have a question it may look daft but here you are : how can we connect the main terminals of the breaker to earth and at the same time injecting with cb mc 2 ? are we not injecting to the earth ? i appreciate if any one reply this question ? thanks
@omicronenergy
@omicronenergy 9 жыл бұрын
Mohammad Bahraini Dear Mohammad, Thank you for your kind comment. The contact resistance is typically very low, of only a few µΩ. The long earth loop on live tank circuit breakers is of much higher resistance, and can therefore be neglected. Should you have any further questions, please feel free to contact our 24/7 free-of-charge technical support hotline: www.omicron.at/en/contact Best regards, Your OMICRON team
@tune7254
@tune7254 9 жыл бұрын
thank you very much for replying my question.
@bourun790
@bourun790 3 жыл бұрын
អគុណ
@sadamahmed5763
@sadamahmed5763 10 жыл бұрын
very good
@skynetcybersystem3tech
@skynetcybersystem3tech 4 жыл бұрын
🖐
Medium Voltage Circuit Breaker Testing with CIBANO 500
4:07
OMICRONenergy
Рет қаралды 6 М.
Правильный подход к детям
00:18
Beatrise
Рет қаралды 11 МЛН
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН
Live tank vs Dead tank circuit breaker | Comparison | TheElectricalGuy
7:38
Gaurav J - TheElectricalGuy
Рет қаралды 25 М.
Circuit Breaker Testing
5:52
OMICRONenergy
Рет қаралды 3,5 МЛН
MV & HV Circuit Breaker Testing Beyond Timing and Travel Measurements
1:33:21
High Voltage Circuit Breaker testing
1:22:52
Electrical Engineering Knowledge Sharing
Рет қаралды 2,6 М.
Antipumping in Circuit Breaker | Why it is needed? Explained | TheElectricalGuy
19:04
Gaurav J - TheElectricalGuy
Рет қаралды 24 М.
Installation of Circuit Breaker 3AP1-FG (Siemens)
9:33
Hien Do
Рет қаралды 83 М.
Transformer Testing with One-Time Test Connection
6:48
T&D World
Рет қаралды 9 М.
Gas-insulated switchgear: safe operation
11:26
Siemens Knowledge Hub
Рет қаралды 276 М.
Правильный подход к детям
00:18
Beatrise
Рет қаралды 11 МЛН