Orifice Sizing

  Рет қаралды 13,479

Clifford Long

Clifford Long

Күн бұрын

Пікірлер: 32
@Jetbill007
@Jetbill007 11 ай бұрын
Usefull for CSE PE EXAM. Have a look at the new NCESS cse REF manual. Thanks
@williamcase426
@williamcase426 2 жыл бұрын
Good
@ripu6464
@ripu6464 3 жыл бұрын
Awesome thanks a ton
@RDCINST
@RDCINST 2 жыл бұрын
You’re welcome!
@jafarmohammadi8549
@jafarmohammadi8549 2 жыл бұрын
Thank you sir for this useful lesson. Which procedure is valid for PIPE TAPS?
@RDCINST
@RDCINST 2 жыл бұрын
You can use this procedure for sizing with pipe taps, but you will need the correct discharge coefficient (C) for the pipe taps. In this video I use the discharge coefficient calculation for flange taps. You can see this at 13:00. The Flow Measurement Engineering Handbook has the formulas for calculating other discharge coefficients on page 9.13 and table 9.1.
@jafarmohammadi8549
@jafarmohammadi8549 2 жыл бұрын
@@RDCINST Thank you
@XimenaCarrera-hs9ys
@XimenaCarrera-hs9ys 5 ай бұрын
hi! what if I am trying to simulate an orifice plate for a tube of 0.5 in diameter, what formulas can I use?
@RDCINST
@RDCINST 5 ай бұрын
Liquid? Or gas?
@RathodRidesRonin
@RathodRidesRonin 3 жыл бұрын
Can you Please make Videos on Thermowell Calculation... and TE sensor length calculation with Extension+Insulation+Thermowell Any typical example???
@RDCINST
@RDCINST 3 жыл бұрын
I would love to do this. I have lots on the go at the moment. I will put it on the list.
@sanjeevupadhyay1457
@sanjeevupadhyay1457 2 жыл бұрын
@@RDCINST please make one video on wake frequency calculation and thermowell designing . Thank you
@manumani903
@manumani903 2 жыл бұрын
Orifice sizing is based on normal flow or the maximum flow?
@RDCINST
@RDCINST 2 жыл бұрын
Start with the maximum flow and multiply it by 0.8 to get the normal flow. 80% of maximum flow is considered to be the normal flow. If you size based on the normal flow you can skip that step, but keep in mind a large increase in flow will be above the range. For the best measurement accuracy, the normal flow should be at 80% of the range.
@pareshachu
@pareshachu 11 ай бұрын
can I have details of the reference?
@RDCINST
@RDCINST 11 ай бұрын
Flow Measurement Engineering Handbook by Richard W. Miller
@sastikanilasari6842
@sastikanilasari6842 2 ай бұрын
Can you explain how to get DeltaP max?
@RDCINST
@RDCINST 2 ай бұрын
This is explained starting at 16:00 in the video.
@mohabd7
@mohabd7 2 жыл бұрын
can i change the range from 100'' to 120'' once orifice installed?
@RDCINST
@RDCINST 2 жыл бұрын
Likely, what flow computer are you using?
@wasteurtime5677
@wasteurtime5677 3 жыл бұрын
What reference material are you using ?
@RDCINST
@RDCINST 3 жыл бұрын
Flow Measurement Engineering Handbook by Richard W. Miller
@wasteurtime5677
@wasteurtime5677 3 жыл бұрын
@@RDCINST Thank you. Also wanted to know if there are limitations to using this method to size an orifice. how large of a differential pressure can I size an orifice for? A few references mentuon that when dealing with gases, this method is not suitable if ratio of downstream pressure to upstream pressure (@ the taps) is greater than 0.75. Is that the case here?
@RDCINST
@RDCINST 3 жыл бұрын
@@wasteurtime5677 refer to page 9.54 of the reference. It’s pretty standard to size the maximum flow to produce 100”H20 or 25 kPa. This is a standard range for the device used for measuring differential pressure. I have seen some flow computers that have a maximum range of about 65 kPa, so it would be important to know that maximum range for the device measuring differential pressure. The reference says to limit the ratio of differential pressure over static line pressure to less than or equal to 0.04 for gases.
@panoskb9405
@panoskb9405 3 жыл бұрын
The flow rate before and after the orifice plate are the same?
@RDCINST
@RDCINST 3 жыл бұрын
Yes, the mass flow rate is the same before and after.
@RathodRidesRonin
@RathodRidesRonin 3 жыл бұрын
@@RDCINST How to reduce permanent pressure loss?
@RDCINST
@RDCINST 3 жыл бұрын
@@RathodRidesRonin you can’t avoid the permanent pressure drop due to an Orifice. A common differential pressure range used for sizing an Orifice meter is 0-100 “H2O. This means the pressure drop should never be more than 100 “H2O. If this is too much, consider using a Venturi tube over a Orifice meter. It produces a lower permanent pressure drop.
@harshdesai6505
@harshdesai6505 8 ай бұрын
Is it for restricted orifice??
@RDCINST
@RDCINST 8 ай бұрын
Are you talking about an orifice used for choked flow?
@donalddorn7507
@donalddorn7507 Ай бұрын
@@RDCINST yes do you have a class for gas choked flow restriction plate (no measurement)
@RDCINST
@RDCINST Ай бұрын
@@donalddorn7507 Sorry I do not.
Orifice BETA RATIO limit | Why does it EXISTS !!
7:09
Asad (I&C Engineer)
Рет қаралды 17 М.
Types of Orifice plates | Piping
5:18
Technical Piping
Рет қаралды 61 М.
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 26 МЛН
Control Valve Basics
32:50
Douglas Price
Рет қаралды 60 М.
Brake System Sizing And Design
20:14
Suspensions Explained
Рет қаралды 10 М.
Do Pumps Create Pressure or Flow?
10:38
Practical Engineering
Рет қаралды 1,4 МЛН
Orifice Sizing in Aspen HYSYS
8:56
Process Engineering Guy
Рет қаралды 7 М.
How does an Automotive A/C System work: Part 4 FOT and VOV Diagnosis
21:15
Orifice Sizing and Selection - Quick and Easy || Learning Engineering Solutions || LES ||
9:28
Orifice Plate Design
6:08
ChemEngPro
Рет қаралды 4,8 М.
Control Valve Sizing Made Simple | 3 Golden Rules
9:44
Asad (I&C Engineer)
Рет қаралды 12 М.
8-Orifice Flanges
6:19
Mr Engineer
Рет қаралды 8 М.