What a terrific video for this non jandyman. It must haave been a nightmare for the owners but helped immensely by having someone who is a proper and trustworthy professional dealing with it.
@JU5TAGAM3R3 жыл бұрын
I've just started my level 3 plumbing and been getting some experience with a plumber. He said to watch your vidoes and tbh I've learned so much from watching you. Love the vidoes mate keep up the great work!
@allencowe94462 жыл бұрын
I'm a bit late in seeing this. I had a similar issue before at a hotel. We left the heating on with all rads turned off. It made it much easier to find the leak as the boiler was at temperature so the heat escaped through the leak. We then found it with the thermal imagining camera. Great video, thanks for sharing.
@SiKay30003 жыл бұрын
Worked at BG for 28 years and we used fernox leak sealer. Very rarely did it make any difference what so ever. Started using ct1 miracle seal and it never failed even on systems that were losing full pressure daily. It does not block boilers including combi’s as well.
@theCybershot1233 жыл бұрын
It worked for me more than once
@johnread1201 Жыл бұрын
How much miracle seal did you use to plug the leaks?
@johnread1201 Жыл бұрын
My plumber has used one bottle on two separate occasions and it’s made no difference
@normanboyes49833 жыл бұрын
Good video and a good example of the consequences of burying unprotected copper in concrete.
@jennyli77492 жыл бұрын
I had exact same problem and ended up paying for a new boiler, heating engineer took a guess at where the leak was cos new boiler was still losing pressure, and found it to be the plastic pipes under floor of the extension (he said often extensions used plastic instead of copper so more likely to leak due to degradation. He was correct! My other option was to dig the floor of top end Karndean flooring which I wouldn’t have been able to afford to re lay if random holes were to be dug all around house 🙁
@djgaryc3 жыл бұрын
Great video. I know nothing about plumbing but was able to follow and understand the methodical approach. Very interesting 👌
@UberAlphaSirus3 жыл бұрын
Good tips. I have some tips for you too. Dunno if that camera does it, but if you can set it to not have a dynamic/auto range and set it to manual range. set the bottom range 0c and highest range to about 80c. That will give you a consistant picture vs heat. IE your cuppa tea at 38c won't be the same bright yellow at 80c 4 seconds later pointing at a hot feed. If that makes sence. It's not always possible, but it's alot easier if a client can keep the heating off for 24 hrs before you investigate with a heat gun. this is because of heat soak. if you start with a cold pipework and structure, you can observe the spread of heat before everything has heat soaked and reached an equilibrium. Shows up well on wet materials as wet stuff conducts heat faster. But again thats why it's best to have a fixed scale on the camera, as before and after pictures and recording will look basicaly the same with auto scaling. All the best, top fella.
@pasgas12safe583 жыл бұрын
Sirius, very interesting mate, thanks for your logical input!!👍👍
@frostie19703 жыл бұрын
Heard a tip from skillbuilder. Put a cheap aftershave in the heating cct and literally sniff out the leak.
@JakeMcNamara13 жыл бұрын
actually thought when you had thermal camera on at the entrance it did look quite spread out. Fair play to the guy for digging it at least 🤣 great video.
@PBPlumber3 жыл бұрын
yeah when i was editing it i thought it looked more spread out, it didn’t register with me at the time tho
@JakeMcNamara13 жыл бұрын
Easily done, I'd say on the day I'd of done the same 😃 👍
@makg46553 жыл бұрын
@@PBPlumber DEFO LOOK INTO OPENING A AMAZON SHOP SELLING TOOLS YOU REVIEW .. it’s a great passive revenue stream and ensures people get the right products.. it costs nothing just a few hours of time . Well worth hooking up with a 4th year student doing social media as they will help u sort and add additional revenue streams obv make themselves a wage for it but it’s ££ u are not making now so 50% of something is better than what u get from it now .. ALL THE BEST FOR 2022
@BTW...2 жыл бұрын
By far the quickest, easiest and most accurate way to find leaks is by use of sonic detection methods. Small accelerometers (like microphones) are located between a pipe run and the sound of fluid passing through the leak is detected. Time delay between the 2 sensors is calculated and the leak location is determined within a few mm. Thermal imaging is all well and good, but through carpeting and concrete is highly optimistic.
@nickgiles19912 жыл бұрын
you would not correlate in a house... surely just listen at all available points.. correlators get confused by branches and caviation... i often use a combination of acoustic and tracer gas
@sam.p123454 ай бұрын
Accelerometers and microphones are two different things. Granted, an accelerometer is likely to be minutely responsive to sound waves, but you wouldn’t use an accelerometer to detect sound.
@davidceredig-evans87723 жыл бұрын
Excellent video. Thanks for all the hard work you put in.
@peterfitzpatrick70323 жыл бұрын
Lifting the carpets before thermal imaging might have been a good idea... 🤔
@syncrosimon3 жыл бұрын
Bit of lube on those slip joints keeps the rubber happy👍👍 interesting job😎
@derekmears34342 жыл бұрын
Good work Pete.
@sheli4239 Жыл бұрын
We can hear water movement in the pipes, sounds like a seeping toilet valve. There's no visible leak above the slab anywhere, so it's probably under the slab in our 35 year old house in Florida. We have extremely hard water and just did some bathroom mods. Shower, wall toilet and maybe we shook loose a ready to blow copper line when we did the bathroom. Seems like a pinhole because the well pump doesn't really come on too often , maybe once an hour.
@Liam....3 жыл бұрын
The helium thing reminded me of a tip from Roger Bisby to tip a cheap bottle of aftershave or perfume into heating system then have a walk round and see if you can get a wiff of it anywhere, not sure how well it would have worked through a concrete floor though.
@Daniells19823 жыл бұрын
What would be your poison of choice, Brute, Hai Karate, lynx Africa?
@Liam....3 жыл бұрын
@@Daniells1982 bit of joop I recon 😂
@Daniells19823 жыл бұрын
You'd smell the leak from next door mate 😂
@suzylarry1 Жыл бұрын
I was told a s a youngster doing this search and discover when it is large and hidden . If you can locate the center of the , be it system or dead wire , open access , now you have done 50 % of the search , it is either behind and further or ahead farther along . Now do the same on the effectided end ( divide at center from open section end or beginning ) depend witch way the pressure/signal is lacking . So basically divide 50 % is fore or aft , then divide that next 50 % and you only have a 1/3 left to investigate.
@ipod19783 жыл бұрын
First class video and quite surreal as I’m having somewhat of a similar type issue on my own system (again ffs). Old house, F&E system. Boiler is in good condition and has been/continues to be serviced every year, pump was replaced a year ago, both located outside in shed. Hot water cylinder on first floor with header and expansion tanks in the loft. Found a leak on both the flow and return literally 75mm apart from each other between two downstairs radiators right in the middle of a doorway when renovating the house. Both leaks had been "fixed" by a plumber during lockdown. Original pipe work to be fair was very poorly wrapped with no protection and then back filled with a very coarse concrete which caused the leak in my opinion. High traffic area too being in the centre of a bloody doorway so it was a no brainier and sheer luck that I even found it before the floors went down. Ok, now I’m hearing water coming in to the house via the mains even when no water is being run. Can’t tell if it’s on the heating side as the noise is evident even if the heating is switched on or off but only seems to happen really at night or at least I seem to notice it more at night. This has been going on for over a month now. Bathroom is downstairs with the pipe work running vertical. It’s boxed in and tiled. Toilet is mains fed so it’s not a leaky cistern. It’s definitely coming into the house because when I turn the stop cock off, the water noise ceases. I’m tempted to carefully drill into tiles at the bottom near the back of the toilet and use an inspection camera but then saw this and wondered if the thermal imaging or helium options would be viable on an oil boiler system? I both love and hate this fkg house all at the same time but this is my last hurdle but I’m at a loss. The first plumber I used who fitted the new circulation pump is to be honest a bellend, a guy from my previous town who I knew of but he left leaving a leak on the same "new" circulation pump he fitted right before trying to sell me a used oil tank. Second plumber who actually fixed my leaks even though he used plastic compression fittings, he did find and also resolved the leaking circulation pump issue ..during lockdown .. and did a fair job but while I genuinely rated the guys professionalism I was disappointed with the use of cheaper fittings however it got it fixed and my floors went down. Second time around when I called the second plumber out again i had to wait for just over 3 weeks to even get him here. When he did finally call out he only checked the ball valve in the loft and then as he was leaving informed I’d have to find any leaks myself but he recommended using leak sealer. I took the hit and spent £20 on MC4 at my local trade store and so far I’m still none the wiser but a little pissed off at having to bleed all of my radiators yet again caused by adding the leak sealer. Getting the hump to be fair even now. Sorry for gassing, feel like this turned into somewhat of a rant halfway through rather than simply asking if helium and thermal could/would work on an oil boiler F&E system. I have photos of all of my issues by the way that I took when renovating the house so I feel this customers pain having to hammer out concrete floors.
@joshcowart24462 жыл бұрын
Interesting I didn’t think you could use propress under a slab. I noticed the fittings look different over there as well. Ours have another bit of fitting past the o ring. We’re also not allowed to solder under a slab. We’d run 4 separate lines and tee it in the wall. If we absolutely had to have that tee or we’re doing a repair under a slab we have to braze it.
@BTW...2 жыл бұрын
Use of soft solder is simply asking for trouble. Silver solder (brazed) results in a joint stronger than the copper pipe. Press fittings have a cost and strength disadvantage... only good for saving time and perhaps risk of using flame.
@joshcowart24462 жыл бұрын
@@BTW... couldn’t agree more. I always silver solder under a slab. I don’t know where your at but I’m pretty sure both codes in the US require it. Though not going to lie, I’ve soldered under a slab before. It was because I didn’t have any silver solder or only had a portable torch, I can’t remember. It was couplings so I figured it wouldn’t be under a lot of stress compared to other fittings
@BTW...2 жыл бұрын
@@joshcowart2446 Here in Australia.
@joshcowart24462 жыл бұрын
@@BTW... seems like y’all’s code or at least what y’all consider best practice is sake as us. I didn’t mention pro press in my reply. I use it in repair situations when I can’t get the water drained out. I’ve also used them in situation where I’ve had to shut down a building and tee in to a main. It’s much easier to put a press tee and valve and then turn the water back on than it is to blow all the water out and solder. My company uses it on all commercial new construction. That’s for two reasons. One it probably saves them money on time and two they have a lot of young people who can’t solder. A couple of them can do it in a bind but they wouldn’t know what to do at a job where every single fitting is solder. However in the back of my mind I worry about those jobs. A repair is one thing but a whole job is another. I’m hesitant to install an o ring or any washer that I can’t change. I worry how those o rings hold up long term. I’ve seen solder joints that are 70 plus years old and fine. What happens to pro press in 20 yrs. I worry that’s it’s like a lot of things with building these days. They’re built to last 20 yrs but not longer. Another factor I just recently learned about was how they deal with freeze. I’m in Texas and we had the unprecedented 4 day snowstorm without power last year. One of our jobs had a 1” (28 mm) line running 50’ (about 15 m) under the floor on a balcony of a high rise. It feeds some planters up there. Contrary to popular belief when a line burst from freezing it isn’t directly from the expansion. Copper can take that and will even stretch. What it does though is create an ice block and then as it freezes more and more it create thousands of pounds of pressure down stream. This is what causes the pipe to burst. This pro press fitted line just pulled every single fitting apart. I think it was 3 couplings. The amount of damage is more severe because you have a wide open pipe now as opposed to a gash. Though once a pipe hurts it may put out so much that it doesn’t matter. Also they had to pull up the floor in 3 separate spots to repair it. Whereas solder it would have burst in one spot. Basically the cost to repair will be higher and possibly the damage will be more if it freezes.
@BTW...2 жыл бұрын
@@joshcowart2446 Happy to say pipe freeze is very unlikely here, except in alpine zones. Bit of a worry that 'youngers' in the trade don't have solder skills, or don't seek to learn. Bit of a worry.. and how low can it go? I hazard a guess they don't know how to measure, bend and fabricate pipework too, without the need to add unnecessary couplings, Yeah, there is that 'instant gratification' of just grabbing a bucket of press fittings and wacking stuff together on the fly, with little need for accuracy, yet pretty certain no leakin' first time. And there is that factor of horror job sites where you can't get out of the place quick enough... the kinda places you remember years later. Man, basic soldering - I learned how to soft solder at 8 years old in the electrical/electronic field... and in my early teens plumbing fittings, a few years later in the sheetmetal fabrication field... some roof plumbing too (where now it's pop rivets and silicone bog to do the job... nasty. That was prior to any trade training. Late teens brazing copper, brass and steel. Done a fair bit of instrument plumbing during my apprenticeship (electrical fitting/mechanic). I had used swagelok fittings prior to that anyway. Early 20's it was a mix of electrical and refrigeration fitting... in-field fault diagnosis repair. Interesting trade the HVAC.. gotta know electrical plumbing, gas systems, mechanical, sheetmetal and air handling. Freezing... uhghhh. Seems a pressure relief 'fuse' would be a fair idea in the 1" branch you described. Press fit has it's normal design pressure with safety margin, sure. But to deal with freezing down a closed line.. a copper end cap and lower gauge annealed tube over a tundish drain located at every level... in an easily opened service stack... when extensive use of press fittings are used.. perhaps? I sure have my doubts about press fittings, but they are regarded as acceptable for hot/cold mains water and Nat gas supply here... so it follows that failure in service due to freeze is covered by building Insurance, I guess. I've actually seen press fittings in service, that have been accidental not crimped by original installers sitting there not leaking! Doesn't stop me having thoughts before sleep though, sometimes. But back to the heating line repair in floor... I see 4x 45 degree press fittings where a saddle set bend could have been used for clearance... OK, perhaps 1x 45 close to the main line tee. Then again... braze fabricate the repair piece including the Tee and use 3x straight slip couplings to patch it in.
@thoroughflushltd49053 жыл бұрын
Great video Pete, don’t you just love helpful customers like that. 👍
@doubleedge53 жыл бұрын
Smashed it again PB. Very interesting video. Glad u guys sorted it. Customer seems like the ideal customer, making holes in the floor lol
@jamesbrough79753 жыл бұрын
Great video Pete, have you tried adding a fragrance to the system water before?
@OHYEAHGAMEVIDEOS3 жыл бұрын
done these jobs before. I also find leak sealer can take a while to work, it will only plug small weeps though.
@CommercialGasEngineerVideos3 жыл бұрын
Although people say leak sealer works I've never witnessed it working for myself. Tried again and again but no joy. System cleaner yep.
@conaran70393 жыл бұрын
I've found a good few times the leaks close to an outside doors, under sinks or close to heating source or cylinder. But also found not so common in passages.
@pallsmortion47503 жыл бұрын
Bagging a prv is a good little trick, I cut the finger off a rubber glove and do the same, it holds itself and no need to tape it
@lordtobe27743 жыл бұрын
Too much information there..😁😁😁
@pussinboots11452 жыл бұрын
Won't you get a cold wet finger though?
@mrcagas11583 жыл бұрын
If it's only a temporary fix. Why would you just not use speedfit?
@cliveramsbotty60773 жыл бұрын
i love the way you deal with customers that jabber on endlessly as they attempt to explain the details of the job you clearly already know lol just totally ignore them
@potholerrepairsterra3 жыл бұрын
Not really, customer was pointing out that the pipes were hot round the system till last rads, then return was cold - suggesting the leak was on return between last rads and boiler. Which i think it was from what he said?
@normanboyes49833 жыл бұрын
I think the customer was well informed, knew what he was about and imparted very useful information. Only a fool would not at least listen to what he had to say. That is not to say you do not need to verify - just listen.
@CommercialGasEngineerVideos3 жыл бұрын
Clive long time no see. This is where you're hiding.
@nicolebourcierphotographer Жыл бұрын
I had a plumber come and he changed my expansion white bottle but installed a much larger bottle and since have been losing pressure everyday
@darrenmackenzie18922 жыл бұрын
Remove all carpets then you've got underfloor heating! Great job! It would of been a nightmare trying to find where the leak was.
@kevinisaac91393 жыл бұрын
I had exactly the same but we are going to replumb downstairs circuit as they have separate circuits and put in drops
@Smart_fix3 жыл бұрын
Good job Pete repairing pipe under floor is sometimes hard but you did it so easily 🙂👍🏼💐
@nickgiles19912 жыл бұрын
Enjoyed the video, i have been doing leak detection for over ten years and there are very few vids out there... It is hydrogen we use not helium... actually it is 95pc nitrogen mixed with 5pc hydrogen and it is a really effective process although as you can imagine every job is different and poses new challenges... Although the gas is a smaller particle and should leak more easily.. it is cold which straight away is a change from the normal leak condition of heat up or cool down as the system is being used... push fit plastic system leaks can be very fiddly to recreate the leak. The infra red survey is best done from cold... leave off over night, that way you get sharp outlines and hopefully can pick up the bloom you are looking for before the heat spreads too much - in this case it would have been hard because the leak was at a nexus point of pipes in a tight area.
@Memories4lifemedia3 жыл бұрын
i always put a microfiber cloth over the agitator just in case of starches...
@theforkieman3 жыл бұрын
Great video yet again P.B. So glad you had a good break and recharged your batteries( literally lol ). I’ve got a thermal camera really useful I got mine to fix leak on lead pipe in concrete floor but I’ve got a problem my pipe is shared under my floor with neighbour. Was going to renew with poly pipe surface mounted and just box in but can’t cause of neighbour really stuck at moment. Anyway hope family all good and keeping safe and looking forward to your 100.000 subscribers. Won’t be long I’m sure
@rickystephenson5182 жыл бұрын
Hmm the bed tricky area ,found my self in some embarrassing situations moving customers beds lol
@completepreservation3 жыл бұрын
Decent video Pete👍 be worth investing in a moisture meter and some acoustic equipment. I use the Sewerin stuff for leak detection it is brilliant 👍 thot press fit looks decent 👌👌👌
@ivan79uk3 жыл бұрын
Cau I have the model for leak detection please? Thank you
@completepreservation3 жыл бұрын
@@ivan79uk aquaphon a200 is decent 👍
@garethevans77733 жыл бұрын
But you some Geophones and push air in you’ll hear it bubbling
@tccoggs3 жыл бұрын
Worst thing about under slab pipes. Eventually they all fail. Nice work on the fix.
@mehrajhossen253 жыл бұрын
Sir , you are doing great work
@TOMLINBISH3 жыл бұрын
I bought a 2 bed 1910 built mid-terrace house in 1991 by myself and I had a major water leak under the kitchen floor a few weeks later. I got an emergency plumber out & the old lead pipe was relatively easy to get to under the kitchen floor which was made up of quarry tiles on top of sand, but both this and 12% mortgage interest rates definitely didn't help my finances and stress levels! 😬
@ultragrimeuniwipe5263 жыл бұрын
Great video! Thanks for the shout out!
@amd4life893 жыл бұрын
Really enjoy your videos, keep up the good work.
@albertroundtree2993 жыл бұрын
Excellent job Sherlock !!
@chiron6699 Жыл бұрын
Amazingly lucky that customer didn't damage any pipes digging out floor. Last time I did that that's what happened to me
@SuperWayneyb3 жыл бұрын
Great video Pete, Happy New Year folks 🤘😎🤘
@tigingrasta9533 жыл бұрын
I rap electric tape around copper tube before concreting
@metallitech3 жыл бұрын
The scale on the thermal imager display is dynamic. Can it be set to stay the same? I'm just wondering if this would make it easier to use.
@johng95622 жыл бұрын
You're ALWAYS better off soldering those connections because the slip/crimp fittings rely on an O-ring to seal and they ALWAYS LEAK over time, while leaks in soldered joints are rare.
@BTW...2 жыл бұрын
They surely leak when the tube isn't free of defects like dents or score marks, as seen in this case.
@derekearles98442 жыл бұрын
But as the plumber said its only temporary as the house is being demolished
@wilson41802 жыл бұрын
We’ve been using pro press for both gas and water for 3 years now, mostly commercial, and have yet to have a problem and stuff gets beat to hell in commercial spaces.
@simonw728410 ай бұрын
Brilliant video. Have a leak under concrete. Helps provide me with a few ideas (especially the comment further below in regards turning of all rads before further testing using thermal). Thank you.
@ArmstA793 жыл бұрын
Shame the customer didn't take a video of the leak for you Pete! I bet it was a headscratcher, well done.
@50842043 жыл бұрын
Heating pipes were literally thrown inside the concrete, on an uninsulated ground... well, it is a very rich country and can waste shit loads of energy.
@joetrippi16032 жыл бұрын
Hot water expansion/contraction just destroys copper piping when under the slab….just a matter of time…retired plumber speaking from experience
@richardsedorski12063 жыл бұрын
Excellent vid wish you had more of those.👍👍👍
@HomeHaxАй бұрын
If there is no loss of pressure showing on the boiler then can one rule out a water leak on the central heating system?
@bryanyoung94822 жыл бұрын
When u were doing the thermal that spot stuck out to me.
@Jack-cw1bb3 жыл бұрын
Hi Pete, curious as to what happened with those two end rads that weren't getting warm until you flushed the system and found not much debris on the magnets? Did they run hot after you opened all the rads?
@amd4life893 жыл бұрын
I suspect it was more likely that the system was poorly balanced rather than any sludge buildup.
@rickystephenson5182 жыл бұрын
25 years in this game and still learning daily
@robertwhite43753 жыл бұрын
Great video as ever. Always interesting to watch. Did you realise you swapped the flow and return connections to the branch pipe when doing that repair?
@marklfc94223 жыл бұрын
Well spotted mate 👍🏻
@davidceredig-evans87723 жыл бұрын
I've just checked. No, I think the repair was OK and the pipes weren't swapped.
@jgodda92043 жыл бұрын
@@davidceredig-evans8772 watch it again. Pipes on the left are Td in the other way round.
@WEEChannel-in4wi3 жыл бұрын
Yeah definitely got the pipes mixed up
@UberAlphaSirus3 жыл бұрын
I have never ever ever done that before :D. Balancing is gonna be a headache.
@tundeuk2 жыл бұрын
I’m disappointed the that the heat sensor didn’t pick up the leak, and that the customer had to find the fault by himself.
@davej63353 жыл бұрын
Great video Pete 👍🏻
@ursusmaritimus71593 жыл бұрын
Ace vid Pete, learnt a lot from that. Cheers mate.
@lyndamcardle41232 жыл бұрын
Sometimes, jobs are not that easy to resolve...glad it was in this instance !
@maintenanceman10152 жыл бұрын
Don`t know if it would have worked here but I have shut the return off, turned off the circulating pump ,left the boiler on, wait a while then just follow the hot water with the camera. Had a bigger leak might not work on small leaks.
@keithbrueton3 жыл бұрын
Great video Pete thanks
@christopherwilson26062 жыл бұрын
Those jobs you remember, are called experience.
@derrickrobertson47152 жыл бұрын
Do you need to drain down to remove the fernox after you have flushed around system or do you leave it in?
@bvjilka2 ай бұрын
Great video , thank you so much. I have Subscribed to your channel.
@dickson92003 жыл бұрын
Hi Pete, always enjoy your videos, i hate these kinda jobs usually spend a lot of time on them for not much reward and always think how do I charge for my time, but in this case I'd probably have cut a fill loop in with a prv set to about 1.2 since the house is being knocked down soon. Off topic from the video but what is your honest opinion of the nerrad benders currently have a hilmor but on 22mm pulling sets it's twisting the pipe and was wondering does the nerrad do that before I invest in one, would really appreciate a reply thanks Pete
@jameshawkins52803 жыл бұрын
A absolutely great video m8
@arynaka92963 жыл бұрын
Excellent video: subscribed.
@antonydobson36233 жыл бұрын
How do you find the press fit fittings did you favour those because of speed of the job as opposed to using yorkshire and trying to solder with water in the pipes brill video mate as always 👍
@harpo187bling3 жыл бұрын
Why not leave the temp speedfit on if it worked? Good videos by the way. Thanks for sharing tips and tricks.
@PBPlumber3 жыл бұрын
yeah me and ben wondered that, but he told me he didn’t feel confident leaving it on and wanted it in copper 🤷🏽♂️
@edthelasttribe95802 жыл бұрын
There’s a specific design for speed fit designed for central heating only .
@dardack2 жыл бұрын
Does it matter that you connected the pipes to opposite pipes than what they were? At 30:16 you can see right side goes into closest to camera pipe. At 32:30 you can see left pipe goes into closes to camera pipe. IDK just curious if it matters.
@seanjay8863 жыл бұрын
Looking forward to the meal prep. They have been usual for me. Definitely good to get them out for the Jan fitness kick
@accesszero48033 жыл бұрын
If this house is being knocked down why did u need to replace the plastic with copper? and of it was being knocked down i would have just put a permanent filling loop on with a pressure reducing valve to get by
@PBPlumber3 жыл бұрын
he said he wasn’t sure it was on right and didn’t feel confident leaving it on, so wanted it replacing with copper. i did mention about putting a filling loop on and leaving it open but he wasn’t keen
@deanchapple13 жыл бұрын
Yo PB, thank you doing the vid! Happy new year to you!! 💪🏼🤙🏼👍🏼
@Aepek2 жыл бұрын
19:21 After all these yrs….That EU packout version colour scheme is GORGEOUS, compared to our USA version. Yeah, same thing QC wise, but the colours are awesome across the pond👍🏻 Think of the money MILW could save by just making the Black/Red version for ALL; ‘stead of Red/Black for USA (North America) & the Black/Red version for everywhere else😉 ¹ ¹ edited to add this sentence only
@ikeabuchi110 ай бұрын
Did the customer find the leak?
@ianmowbray32843 жыл бұрын
Great job well done 👍🏻
@Cablesmith3 жыл бұрын
Very interesting video mate. Shame they didn’t start digging at that end ey 😂
@tphvac872 жыл бұрын
I’ve just had that same scenario leaking through the heat exchanger, it was a navien piece of crap straight water heater and my customer had higher than rather water bill, I determined that the internal piping going through the heat exchanger was leaking. He would shut the cold water feed off and condensate pump would stop running (idk if you guys use condensate pumps In 🇬🇧 that’s what was happening) Get this I called my supplier to get a heat exchanger replacement and they called distributor and they said customer had to call Navien directly to have heat exchanger shipped to them 😂 are you kidding me! Anyway those units are junk do not buy, seems like units are made better elsewhere, I’d love to install Worcester-Bosch units here in the states! Cheers mate! Is that something like a propress system?
@sidpf19723 жыл бұрын
If its all coming out I would of left the speedfit in Tbh i also would of tried ct1 leak sealer first as its a temporary job ,that stuff is the nutts Good video though
@paullefur62133 жыл бұрын
It's done mate subscribed now 👍👍
@Cmwgas3 жыл бұрын
let me guess Boxt install no flush? also you can turn the pump speed up on the 8000, its a 15/75 pump on them
@MrRawMonkey2 жыл бұрын
First thing to check would be to see if the rads were balanced.
@jackrussel88982 жыл бұрын
cut pipes each end cap off one then pressure test ?
@astone28933 жыл бұрын
I'm not a fan of my testo 868 it's very poor for finding leaks in most situations. I wish that I had spent a little extra an got the flir e4 now.
@samspry94523 жыл бұрын
I've got the flir and I use it to find hot and cold water leaks under concrete
@JH-rj4bw3 жыл бұрын
May be a silly question/point, but you re connected the pipes a different way to what they were originally, will that not affect it in any way?
@PBPlumber3 жыл бұрын
no such thing as a silly question mate. the only way it would effect the system is if the thermostatic radiator valves weren’t bi-directional (or there was something random like a non return valve, but there shouldn’t be one of those in that location)
@davebennett78053 жыл бұрын
How much did you charge for that job?
@johndonnelly81593 жыл бұрын
Probably need to do a similar job in my house. Does anyone know how you would repair the holes in the concrete floor? Is it just backfilling with the excavated material on top of the pipes the screed the surface?
@TheIcebon3 жыл бұрын
Is that white stuff round the pipes asbestos?
@blackpine66933 жыл бұрын
Are those pipes buried in the concrete…..direct contact with soil……? If so that’s why they are leaking……and will continue to spring leaks…..
@Always_Hustling_UK3 жыл бұрын
Subscribed mate! Enjoying these videos. I start my level 2 next week, can’t wait. Also a keen gym gower. What are your fitness goals?
@tinytonymaloney78323 жыл бұрын
I like your tool bag, details please, I may buy one myself 👍👍
@johncampbell67153 жыл бұрын
If the house is getting knocked down in several months stick an adjustable prv on set to 1 bar.A bodge but whats the point of spending hundreds of pounds on a system thats getting demolished.
@gasmark3403 жыл бұрын
Hi Pete, thanks great vid. When you use MC3 cleaner with magnacleanse do you drain the whole system to remove it before using inhibitor or is there a way to neutralise the system and leave it in? Thanks
@otw59743 жыл бұрын
You should always flush out any cleaners unless they are specifically designed to be able to be left in and you have a suitable filtration system, which is unlikely on a domestic installation. Typically these products contain chelating agents which remove deposits and films from surfaces, so if left in the system will continue to slowly strip material from the internal surfaces, particularly metallic surfaces. Remember also that you need to purge the deposits that the cleaner has removed, and they're not all magnetic!
@gatsu1182 жыл бұрын
Some plumbers are funny about leak sealer. I'm not. I think most of the "scare stories" are old wives’ tales. However, leak sealer should only be used in specific circumstances and caution should be paid to the viscosity of the leak seal. Heating pumps are designed to pump water, not maple syrup 😉 I usually add it to a large radiator. This means the leak sealer will be diluted before it flows into the boiler/pump. If the leak sealer is added to a magnaclean (on the return), then undiluted leak sealer will flow straight into the boiler/pump. I also run the heating for as long as possible before a hot tap is opened (for a combi). This means the leak seal will be diluted throughout the entire heating system before it is sent through the plate heat exchanger.
@johngoard82722 жыл бұрын
Hey how do those tap on fittings seal onto the tubes?? I used to work with my Dad many years ago back in the days when lead pips were still being used in some places and am just interested in how far technology has come in the meantime. Nice job by the way.
@rubberneck22 жыл бұрын
I think those fittings crimp on to the pipe. They look a bit like Yorkshire fittings, but they are solder free.
@johngoard82722 жыл бұрын
@@rubberneck2 Yes mate like In said technology has come a long way since I last did any plumbing I was used to cast iron baths and downpipes gutters etc etc
@arryrooker30792 жыл бұрын
A pin hole in the heat exchanger going into a condense pipe ?
@PBPlumber2 жыл бұрын
yeah the heat exchanger is connected to the condense pipe via the sump and trap so if your heat exchanger pin holes the water goes into the sump, thru the trap and out the condense pipe to a drain and you’d never know