Mikey Pipes - Plumbing & Air By Tom, Inc. December 31, 2023 Orlando, Florida Step by step repair video guide of PENTAIR MASTERTEMP 250 pool heater with damaged gas sensor.
Пікірлер: 34
@kens.37296 ай бұрын
Hello 👋 Tom. Nice to Meet you. Keep up the Strong 💪 Efforts and Thanks for Helping make the Trades Great Again. 👍🙏
@tbofinger16 ай бұрын
Thank-you stayed tuned for more great content!
@MikeyPipesOrlando6 ай бұрын
Thanks, you too!
@scottmaz40636 ай бұрын
I knew it was going to blow with pump on. 😂 job well done Tom
@MikeyPipesOrlando6 ай бұрын
🙏
@scottmaz40636 ай бұрын
@@MikeyPipesOrlando guess he got a little bit jumpy with the camera now. He'll be alright
@TasoV.6 ай бұрын
Happy New Year and thank you for all of the informative videos.
@MikeyPipesOrlando6 ай бұрын
Happy new year!
@scottvolage17526 ай бұрын
Hi Tom Nice to meet you. Happy New Year.
@MikeyPipesOrlando6 ай бұрын
Hi Scott. It’s me.
@tbofinger16 ай бұрын
Thank-you! Stayed tuned for more great content! Happy New Year 🎆
@Poolmedic6 ай бұрын
On the control panel there is a “Mode” button that has three functions as indicated in the box. Press the Mode button until the screen reads “Service”, your are now in Service Mode. Once in service mode you can manually control all your equipment, filter pump, heater etc via the buttons on the control panel. Once finished press the mode button until the screen reads “Auto”. By doing this you will not have to change programming.
@MikeyPipesOrlando6 ай бұрын
Thanks for sharing
@Charbs2020 күн бұрын
Does it matter which terminal the cables reconnect to?
@mattl6436 ай бұрын
Oooooohhh shut that pump down first buddy. 😂
@MikeyPipesOrlando6 ай бұрын
Got him!
@jimmy86536 ай бұрын
Tommy 2 pipes !
@MikeyPipesOrlando6 ай бұрын
lol
@larrymicheletti45174 ай бұрын
I changed the ags and it still will not heat my front panel only shows service heater. The front panel will not light up. The only light is the service heater light. Any suggestions. Thanks
@MikeyPipesOrlando4 ай бұрын
Bad panel?
@kennethbrandon14186 ай бұрын
Definition of punching your way out of a wet paper bag. Never double commented before
@MikeyPipesOrlando6 ай бұрын
Thanks for sharing
@ZmuBMAC16002 ай бұрын
Mine won’t even turn on when I push the button? It worked last nite
@MikeyPipesOrlando2 ай бұрын
Did you try opening the manual?
@kennethbrandon14186 ай бұрын
Guy, what are you getting into? Theses guys are using harbor freight tools? I had a girlfriend that went to pcb for vacation and never came back too?
@MikeyPipesOrlando6 ай бұрын
Send her to Mikey Pipes
@glenrightmire18904 ай бұрын
Hate to be that guy, but it's a 5/8 deep socket, not an 11/16... also, if you don't breach the filter and let the system drain down you will get A LOT of water when you pull any plug/sensor from the heater. Drain filter by opening the air relief valve, wait 5 minutes Then take drain plug out of heater manifold. Once the heater drains you can replace what you need. DONT pull a plug or sensor when a pump running..
@MikeyPipesOrlando4 ай бұрын
Thanks for sharing those tips & tricks.
@dc90396 ай бұрын
I would have replaced that corroded terminal connection.