Per Unit Analysis - how does it work? (with examples) || Basics of Power Systems Analysis

  Рет қаралды 31,982

Visual Electric

Visual Electric

Күн бұрын

Пікірлер: 48
@Rattanhistorybuff
@Rattanhistorybuff 4 ай бұрын
The clearest , easiest to understand explanation of per-unit analysis I have experienced after 25 years of experience and learning and 2 degrees in EE .......well done mate !
@MoussaKHALFI-zt8kr
@MoussaKHALFI-zt8kr Жыл бұрын
The best vid on youtube explaining per unit systems, do not expand time elsewhere. gonna share it
@mayurm9917
@mayurm9917 3 жыл бұрын
we lack such level of clearity in our educational system. Thanks for clearing the most fundamental concept!
@caleb7799
@caleb7799 2 жыл бұрын
This should have more likes. You do not rush through stuff and assume that the listener is with you. I like that you take the time and give a small example after each statement. It might be a slower pace for a lot of us impatient engineers, but if we actually listen, we can see that all nuances and bases are covered very well.
@stambulimisamu4679
@stambulimisamu4679 4 ай бұрын
This guy is a genius. Very clear explanation which is very easy to understand
@JohnHickman-c9c
@JohnHickman-c9c 4 ай бұрын
Thanks for making this topic easy to understand. I have been frustrated by instructors who cannot speak English clearly and don’t know how to explain it.
@k18-y5e
@k18-y5e 2 ай бұрын
as an EEE engineering student, I can speak for all of us when i say you ARE THE PRECIOUS GEM!!
@JosephAMuniz-hm4jh
@JosephAMuniz-hm4jh Ай бұрын
Fantastic! Thank you. I'm taking a power systems class at the moment and was totally lost on per-unit conversions. Your video definitely cleared things up for me. Thank you so much. Very much appreciated.
@uhameed923
@uhameed923 3 жыл бұрын
Very helpful! Very precisely explained! Thanks alot for your time and efforts. Much needed video!
@ΓιώργοςΜάριοςΜερκούρης
@ΓιώργοςΜάριοςΜερκούρης 10 ай бұрын
You explained the whole per unit concept in a much more clear and understandable way than my university professor. Great Thanks!
@GKASHWINTHAN
@GKASHWINTHAN 8 ай бұрын
Thank you, this is the best video on per unit Ive come across. Keep up the great work
@AK-rj5fv
@AK-rj5fv 2 жыл бұрын
Great explanation of this subject. Watched it a few times and it helped me a lot. Thank you 👍
@MrDaniyalAh
@MrDaniyalAh 2 жыл бұрын
U have saved my semester. What my teacher couldnt explain in an hour was better expalined here in 10min
@VisualElectric_
@VisualElectric_ 2 жыл бұрын
Thank you
@atsdroid
@atsdroid Жыл бұрын
My comment is a bit of a side-track, and doesn't involve the 3-phase example at the end of the video. But following along and practicing the technique presented, I'm wondering if some of the examples, if one saw them in the real world, would represent overloads (for the transformers, at least). At 6:39, the presenter explains that choice of S-base (Sb), the apparent power, can be anything, but good practice says you should choose a value that matches (as closely as possible) the apparent power base of your equipment. With that then in mind… In the example at 22:48, the math of course all works, but in that result, is it true that the apparent power is 23 MVA, noting the chosen Sb was only 10? Doesn't that mean we've blown out both of the transformers, one of which was rated 8 MVA and the other 12 MVA? If the example represented a real system, wouldn't you need to ensure the apparent power never exceeded 8 MVA, the (I'm assuming) apparent power handling rating of the lower of the two transformers? I was led to think about this from the prior example showing the nameplate ratings of a transformer at 17:20, which showed it was rated 50 kVA and 3.39%, and the statement following that the percent impedance only makes sense relative to the transformer's base values. Those base values influence your choice of system base (Sb). In the example at 21:15, both transformers were given as 3% and 5% on 10 MVA, and 10 MVA was chosen as the system base. Working the example, the Ipu came out to 2.31∠-17.1° p.u. (assuming I did it right). This is also 23+ MVA. But we chose 10 MVA as system base, because…somewhere this was a rated limit (came from one or both of the transformers, presumably). It seems like only the first example, at 13:13, had p.u. that were sensible for the apparent power capacity of the system (0.9901 p.u.). The video says that power system engineers recognize that values up to 1 p.u. are immediately recognized as a well behaved system. But in the examples presented in the middle of this video, we get p.u. currents around 2.3, suggesting (if the base values were chosen as the presenter recommends) our analysis has /also/ shown us that these example systems are fubar. Reaction?
@humphreyshapi4709
@humphreyshapi4709 7 ай бұрын
Well explained thank you very much now I have a full intuitive understanding of per unit systems
@danishnaseer9808
@danishnaseer9808 2 жыл бұрын
you are amazing i wish i can watch all the adds here again and again it was really helpful thank you again
@Patrick-cq7ce
@Patrick-cq7ce 9 күн бұрын
So clear and compact.
@TheSensation19
@TheSensation19 4 ай бұрын
No idea how you get the Ipu in the pu analysis. Can you explain at 16:13
@kucingbloon8462
@kucingbloon8462 4 ай бұрын
Ipu =Vpu/Zpu
@davenandrew7292
@davenandrew7292 Жыл бұрын
Sir your video is Gold. Thank you ❤
@howardsolitary2801
@howardsolitary2801 Жыл бұрын
the bane of the current education system is the tendency to make things complicated. I wish you could be my uni prof
@VisualElectric_
@VisualElectric_ Жыл бұрын
Thanks!
@pspmhmd
@pspmhmd 2 жыл бұрын
wonderful video about pu in power systems i have many vids regarding this topic and let me tell you that your vid is the most beneficial vid thanks a lot
@KAFKUBA
@KAFKUBA 9 ай бұрын
Great video but I thought you changed each zone to the new base... ah you covered it... but I also thought you have to be in same voltage base and consider turns ratio
@joseclementenavarrete6982
@joseclementenavarrete6982 2 жыл бұрын
Clear as crystal clear, thanks,
@reenadangi9944
@reenadangi9944 5 ай бұрын
Excellent concept
@JosephAMuniz-hm4jh
@JosephAMuniz-hm4jh 23 күн бұрын
@16:20 did anyone else get Ipu = 2.39 - j0.275??? Not sure how he gets positive j. Spent the last 20 minutes running it through my calculator and Matlab, and still get a -j. Thanks in advance.
@sandaruwankapila
@sandaruwankapila 10 ай бұрын
superb explanation, Thank you.
@alialimjan2406
@alialimjan2406 3 жыл бұрын
Thank you so much for the clear explanation.
@junchengli2432
@junchengli2432 5 ай бұрын
Thanks for the great video ! In the last video, I am just wondering if the first transformer ratio is 0.415/11 V instead of 0.415/11 kV ?
@favouradekogbe9302
@favouradekogbe9302 2 жыл бұрын
Thanks a lot, this was really helpful!
@surendrakverma555
@surendrakverma555 Жыл бұрын
Very good. Thanks 🙏🙏🙏
@colejames6438
@colejames6438 3 жыл бұрын
This was very helpful, thank you
@metaverseplayer
@metaverseplayer Жыл бұрын
wonderful. thank you so much
@mohammadayach1632
@mohammadayach1632 2 ай бұрын
Thank you so much
@rea9506
@rea9506 3 жыл бұрын
Very helpful, thanks!!
@danieltaim8311
@danieltaim8311 2 жыл бұрын
Man... thank you so much🙏
@narangtallar7294
@narangtallar7294 2 жыл бұрын
Please upload more videos related to power system and electrical machine
@amirhajjari6211
@amirhajjari6211 Жыл бұрын
Great video!
@gioaliaga8399
@gioaliaga8399 Жыл бұрын
Sir, for the mismatched system base, how come the Vbase of zone 3 is still 20kV? I'm kinda confused...
@VisualElectric_
@VisualElectric_ Жыл бұрын
You have to follow the ratio of the transformers to get your voltage base in each zone. The 220kV/22kV transformer ratio is still 10:1, so 200 kV in the middle zone must still give you 20 kV in the load zone. We just need to be careful to adjust the impedance of the transformer so it matches the system base voltages because the 220/22 kV is on a different base.
@gioaliaga8399
@gioaliaga8399 Жыл бұрын
oh i see... thank you sooo much@@VisualElectric_
@shashitm1084
@shashitm1084 2 жыл бұрын
1000V, 1 ohm impedance should give a current of 1000 A. But your calculations from pu is giving 990.1 A. Why the difference?
@red149
@red149 2 жыл бұрын
great job !
@Pankajmanix
@Pankajmanix Жыл бұрын
Legend ❤
@pawanrodrigo6460
@pawanrodrigo6460 3 жыл бұрын
Can I have your email please?
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
Per-unit system calculations - Tutorial 2.part 1
9:23
CMTEQ
Рет қаралды 9 М.
Per-unit system calculations - Tutorial 1.part 1
12:04
CMTEQ
Рет қаралды 59 М.
What does "impedance matching" actually look like? (electricity waves)
17:08
Lecture 1: Introduction to Power Electronics
43:22
MIT OpenCourseWare
Рет қаралды 981 М.
How LoRa Modulation really works - long range communication using chirps
27:38
“Per unit system” in Electrical Engineering | Explained | TheElectricalGuy
8:48
Gaurav J - TheElectricalGuy
Рет қаралды 25 М.
Introduction to Per Unit Systems in Power Systems Part 1d
11:55
GeneralPAC: Power System Tutorials
Рет қаралды 43 М.
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 96 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН