Hello sir , could u plz do video on. Deviation and investigation, take examples per example in-process reading out of limit or product mix up or foreign partical found in product, or yield out of limit plz take example and explain ,if is there already video plz do share link , its humble request
@hitendrakumarshah37189 ай бұрын
For deviation, you can go through the link - kzbin.infoxuijsumCDnI?feature=share For change controls - kzbin.infoNjBO8TN_0XI?feature=share You will get all learning. Just type Hitendrakumar Shah in youtube and go to videos and choose and learn free.
@vishalszzz3ehgal84310 ай бұрын
Sir, In a multiproduct oral solid and liquid product facility what approach shall be followed for identfication Of objectionable organisims. I mean specific methodology over and above the high level stratergy given in guidance.
@hitendrakumarshah37189 ай бұрын
Yes. i suggest, you can go through USP chapter. It is very clear on objectionable organisms.
@abhishekgupta-pharmers52318 ай бұрын
Very helpful,, ✌
@hitendrakumarshah37188 ай бұрын
Thank you for your kind comment
@urmilabade557826 күн бұрын
We want to install UV treatment for our water plant for intermediate production. and this water is obtained by ion exchange method. But we are confuse either install UF or UV. Can you guide plz. Sir
@hitendrakumarshah371819 күн бұрын
You need to evaluate why you need to install UV or UF? Are you facing any problem? The purpose of both units are different.
@vishalszzz3ehgal84310 ай бұрын
Sir do we need to perform endotoxin tests for Oral liquid products
@hitendrakumarshah37189 ай бұрын
Endotoxin testing is not required for oral liquids.
@veeraganesh19025 ай бұрын
Hi sir thanks for information, I'm A chemist in manufacturing department in API pharmaceutical industry......is there any courses that are use full to me for better knowledge in manufacturing
@hitendrakumarshah37183 ай бұрын
Yes. You can connect with me. I will guide you.
@veeraganesh19023 ай бұрын
@@hitendrakumarshah3718 how can I contact you sir
@veeraganesh19023 ай бұрын
@@hitendrakumarshah3718 how can I contact you sir
@proogamerop526610 ай бұрын
Waiting for today's session
@hitendrakumarshah371810 ай бұрын
Thanks
@vijay18panneer10 ай бұрын
Hi sir, Long back pending kindly make HVAC related video as per request....
@hitendrakumarshah37189 ай бұрын
Sure. Actually i am looking for some good material. Everyone is aware about ISO 14644. Also, I am looking for good pictures to make clear understanding.
@vijay18panneer9 ай бұрын
@@hitendrakumarshah3718 ok noted sir, if you don't mind let me share my HVAC guidelines reference and documents, if you are ready to agree.
@Training-rt3ng10 ай бұрын
Waiting for training
@hitendrakumarshah371810 ай бұрын
Thanks
@Training-rt3ng10 ай бұрын
Welcome@@hitendrakumarshah3718
@GXPTraining10 ай бұрын
Yes sir waiting
@hitendrakumarshah371810 ай бұрын
Hope you’ve attended the session
@GXPTraining10 ай бұрын
Yes sir@@hitendrakumarshah3718
@GXPTraining10 ай бұрын
Good Evening
@hitendrakumarshah371810 ай бұрын
Good evening
@SantoshGoswami198410 ай бұрын
Is it compulsory to have RO system in pharmaceutical water system in a liquid oral facility? If yes, which guideline specify this? Please guide
@hitendrakumarshah37189 ай бұрын
RO is not compulsory for liquid orals. The ion exchanges will increase the possibility of nitrosamine impurities. So, it is recommended.