Is it possible that the coolant is somehow affecting the remote receiver on the wall rather than the probe? Have you looked at it one to make sure all screws are tight and there's no coolant infiltration? Just trying to think outside the box. Ciao, Marco.
@PowerForgeWorkshop3 ай бұрын
Thanks. I'll check that. The lights are coming on normally and all green as described in the manual. I'll check the OSI-20 and also re-clean the probe and check for areas where coolant may have penetrated inside the probe.
@AscendedTechnologiesАй бұрын
Same issues here. I put ours on the shelf.
@PowerForgeWorkshopАй бұрын
I got my probe back from China yesterday. I sent it to SYIL for repair, $200 cost. I haven't tried it yet. I'm not holding my breath, but hopefully it works.
@jasonarnold75783 ай бұрын
Have you added extra lighting to the cabinet?
@PowerForgeWorkshop3 ай бұрын
Not inside. I added three LED shop lights above the Syil, my lathe, and my mill. It helps shed a little more light.
@jasonarnold75783 ай бұрын
@@PowerForgeWorkshop Does the problem with your probe coincide with installation of the new lights? I recall reading something in the manual about other lights interfering with the probe.
@PowerForgeWorkshop3 ай бұрын
@@jasonarnold7578Wow, really? I bought the lights this year. I will turn off the lights and test your idea. Thanks 👍
@jasonarnold75783 ай бұрын
@@PowerForgeWorkshop Yes really. It's well worth trying to eliminate external light as a cause.
@PowerForgeWorkshop3 ай бұрын
@@jasonarnold7578Well. It was worth a try. I turned the lights off and the probe worked the first time, then wouldn't turn on again. I swapped batteries and even turned off the cabin light. I couldn't get the probe to turn on again.