PLC Program Example - Shift Register (Conveyor)

  Рет қаралды 103,444

ACC Automation

ACC Automation

Күн бұрын

Пікірлер: 69
@BucketofBears
@BucketofBears 6 жыл бұрын
Solid video, thanks for the knowledge!
@ACCautomation
@ACCautomation 6 жыл бұрын
Thanks for the comment Tyler. Garry
@mahendraparmar9568
@mahendraparmar9568 3 жыл бұрын
How can I join Auto nation directcompany
@ACCautomation
@ACCautomation 3 жыл бұрын
Hi Mahendra, The following link may help you out. automationdirect.csod.com/ux/ats/careersite/10/home?c=automationdirect Regards, Garry
@pereklund9172
@pereklund9172 2 жыл бұрын
Good video. I have a thing to add about the bits retaining their value at a power out. In these types of shift registers, where there is a motor, there is often a need for a 24v UPS for the plc. This is because of the motors momentum. So the motor will continue to spin some additional rotations after the power goes out. If the plc dont have a UPS the bits will be in the wrong place at startup. The UPS only have to hold the 24v up for a couple of seconds (as long as it takes for the motor to stop completely). This is something programmers often forget.
@ACCautomation
@ACCautomation 2 жыл бұрын
Hi Per Eklund, I agree. Good point. Every application may be different. Thank you for the comment. Garry
@yzwme586
@yzwme586 8 жыл бұрын
Your videos are the best I've come across. The GIF's showing the whole process happen is what I really needed for the last piece for this all to make sense. Thank you!
@ACCautomation
@ACCautomation 8 жыл бұрын
Thank you Adranaline
@thetooth
@thetooth 16 күн бұрын
I've implemented the same idea for a checking station using arrays in codesys since bit's are annoying to work with (needed runtime configurable positions). So then I also came up with the idea of cross checking because sometimes optical sensors can miss things. Rather than an array of bits, I have an array of UINT, sensor station 1 sets the value 1 for every product it sees or sets it to 2 if it should be rejected, when sensor station 2 sees a product it will cross check the register of station 1, and if the first station missed the item (still zero) it goes and marks it 2 for rejection, this means you wont accidently send a bad product out the door because one of the checks didn't happen and it's very apparent when the sensor is not working since absolutely everything ends up in the reject bin.
@ACCautomation
@ACCautomation 16 күн бұрын
Thanks for the comment. Tracking programs like this are great. Your implementation is a great idea. Garry
@user-vm8io4rh3g
@user-vm8io4rh3g 4 жыл бұрын
Спасибо за видео очень интересный канал для обучения
@ACCautomation
@ACCautomation 4 жыл бұрын
Hi Nikolay Doroshenko Thank you for the comment. I appreciate it. Garry Привет Николай Дорошенко Спасибо за комментарий. Я ценю его. Garry
@renaco1145
@renaco1145 8 ай бұрын
Hi, Thanks for the great presentation. What I didn't quite understand is what bit actually has to be chosen to trigger the blow off, in other words, how would we know how long it would take a bit to get to the station/point we want to trigger something? is there any engineering way to get a solid idea on which bits are activated at the time? I am working on a similar application to reject the bad parts in a very rapid rate on the conveyor. What if 2 or 3 consecutive parts are bad? would this idea still work?
@ACCautomation
@ACCautomation 7 ай бұрын
Typically an encoder gear with a proximity sensor will detect the movement of the conveyor. This pulse from the movement of the conveyor is used to determine the distance travelled. When the bit turns on with the correct distance, the product position is known. I hope this helps you out. Regards, Garry
@XuanThanh351934
@XuanThanh351934 6 жыл бұрын
thank you for video.
@ACCautomation
@ACCautomation 6 жыл бұрын
Hi Xuan, I appreciate the comment. Thank you, Garry
@mahendraparmar9568
@mahendraparmar9568 3 жыл бұрын
Happy Christmas Garry.
@ACCautomation
@ACCautomation 3 жыл бұрын
Merry Christmas Mahendra. Garry
@princnsukwi765
@princnsukwi765 7 жыл бұрын
Hi, good work ! What software are you using for programming .....?
@ACCautomation
@ACCautomation 7 жыл бұрын
Hi Princ, I am using the Do-More Designer software that comes with a simulator. The latest version is 2.0. You can download this free software from the following URL: support.automationdirect.com/products/domore.html Let me know if you have any other questions. Thanks Princ Garry
@BayMacDre415
@BayMacDre415 6 жыл бұрын
Clearly the SR instruction is shifting ALL of the bits up, as can be seen with memory locations V2-V10 being updated once the bits pass out of V1. My question is, how far up the memory list does the SR instruction push bits, will it be affecting ALL of my V-memory ranges, such as a word in memory location V54? Cleary this would lead to catastrophic results if it shifted EVERY address above the starting point, so my question is how does the instruction know "how far back" to push the bit? I would have liked to see V11 also in the data watch. I am assuming that no 1's were loaded into V11, but I don't understand how you specify this (The end of the "shifting memory" range). How do you specify this "bit length"? I'm sorry if that was confusing.
@BayMacDre415
@BayMacDre415 6 жыл бұрын
How do you protect yourself from shifting bits in registers or V-memory locations which you didn't intend to modify, I guess that's a better way of phrasing my question.
@ACCautomation
@ACCautomation 6 жыл бұрын
Good question Rob. When the SR instruction is programmed you specify the start location and the end location. In our case it is V0 bit 0 to V15 bit 15. This will give us a total of 176 bits to shift. You can see more detail of this video at our website: accautomation.ca/plc-programming-example-shift-register-conveyor-reject/ V16 is the first register outside of the SR instruction. You will not see any bits shift in this location. Another example of the shift register in action using Factory IO: accautomation.ca/plc-programming-example-sorting-station-shift-register/ Here is the testing video: kzbin.info/www/bejne/jWHEmpWPl5h3pKc Here is the explanation video: kzbin.info/www/bejne/j37PY3eGosSsl7c Hope this helps you out. Regards, Garry
@prasennasunder3878
@prasennasunder3878 7 жыл бұрын
Hello Garry, Im beginner in automation field.. I want to enhance my plc programming skills.. Can u give me some tips on developing my programming skills? Is there any particular website which have lot of programming examples ?
@ACCautomation
@ACCautomation 7 жыл бұрын
Hi Prasenna, On our website at accautomation.ca you will find a menu with basic and advanced programming. It will take you through a couple of different controllers. accautomation.ca/programming/plc-basics/ accautomation.ca/programming/plc-programming/ The basic logic is mainly the same in all PLCs. I would find out the common PLC that is used in your area and try to get a unit to practice on. If you cannot then you can always use a software with a simulator for practicing. kzbin.info/www/bejne/qGasimeGZ817p7c You may also want to check out some forums on PLC programming. www.plctalk.net/qanda/ This will give you an idea of the questions and answers to many different kinds of PLC's that are being used. Regards, Garry
@prasennasunder3878
@prasennasunder3878 7 жыл бұрын
thanks allot for ur fast response Garry. I gone through ur website.. It is wonderful... Thanks again for letting me know other informations...
@MegaSaketgupta
@MegaSaketgupta 3 жыл бұрын
How to use encoder couting with shift bit register. For eft shift
@ACCautomation
@ACCautomation 3 жыл бұрын
Hi Saket Gupta, This will work with an incremental encoder using only one of the phase inputs to an input. These encoders will have outputs A and B which are 90 degrees leading or lagging each other. This will show direction. You will only wire up one of these outputs to get the pulse from the unit. Ensure that the pulse input frequency is less than the scan time of the PLC. I have used the following dart product for the ease of installation on a shaft. ebay.us/jKD8Zt Regards, Garry
@ielkhatib32
@ielkhatib32 4 жыл бұрын
Hi Garry, Thank you very much for all the efforts you put in your videos>>> Actually I have a some questions about this video, hopefully I could find the answers: 1. how do you calculate the length of the data to be shifted within ( how many words ?? ) 2. Is this applicable for other PLC platforms cause i found siemens, or Delta for example are a bit different and I don't get it >> why such a powerful technique is not applicable in all PLCs ?? 3. Is there other techniques to do part tracking apart from shift register technique ? ? thanks in advance for any help you might provide.
@ACCautomation
@ACCautomation 4 жыл бұрын
Hi Ibrahim, Thank you for the comments. Here is the corresponding website that will have additional information. accautomation.ca/plc-programming-example-shift-register-conveyor-reject/ You would calculate the amount of shifting that you need based upon the clock (shift input) that you use. This is based on the amount of travel that is required. Data shifting is usually available for most if not all controllers. The naming and the actual implementation may be slightly different but the general concepts still apply. There are other techniques that can be used. It would depend on your specific application. A counter can be used and you would compare off of the counter. Other techniques I have seen are using timers in conjunction with shifting. I hope this helps you out. Regards, Garry
@ielkhatib32
@ielkhatib32 4 жыл бұрын
@@ACCautomation thanks, I think it is helpful.
@ACCautomation
@ACCautomation 4 жыл бұрын
@@ielkhatib32 The online PLC simulator does not have a built-in shift register instruction. accautomation.ca/series/plc-fiddle-online-plc-editor-and-simulator-in-your-browser/ Here is the PLC Fiddle Shift Register www.plcfiddle.com/challenge/68091ce1-59cd-4686-8f4b-9aa0a047618e Here is the explanation of the code kzbin.info/www/bejne/hn-2nnybi56gj6M Just another way to do a shift register Regards, Garry
@ielkhatib32
@ielkhatib32 4 жыл бұрын
@@ACCautomation Thanks Gary for the response, actually I did find the shift register in Siemens, Delta, Domore and OMRON.. you helped me a lot but still the question... In your sorting station video you used 3 shift registers the first one ( v0 to v19) and the output was on ( v0.8) .. now how did you know the exact place of your output regarding to the conveyor ? And if it's in the first word why use 20 words ? The second shift register you used ( v20 to v29) ten words and the output on the second one .. same questions why ten words and how do you know the actual output ( v21.15) .. and same questions for the third one sorry for inconvenience but hopefully you get what I mean ..
@ACCautomation
@ACCautomation 4 жыл бұрын
@@ielkhatib32 That is a good question. In the sorting example, 3 shift registers were used because our sensor picked up 3 different items that had different destinations. At the time of programming, I was unsure of the number of registers that would be required to shift in order to get the output needed. The shifting was done with the timing of the conveyor belt. Each of the 3 shift registers used the same timing for the shift (Same belt). The actual bit used is determined by the position of the object on the belt when it has shifted X amount of bits. In our case, it is when the object is in front of the ramp. I hope this helps you out. Regards, Garry
@manojmistryeee9443
@manojmistryeee9443 Жыл бұрын
Can get ladder diagram in wpl software 2.48 if you can pls make video and post by tomorrow morning or afternoon
@ACCautomation
@ACCautomation Жыл бұрын
Hi Manoj Mistry EEE, Additional information for this video can be found at the following URL: accautomation.ca/plc-programming-example-shift-register-conveyor-reject/ This will show you the steps required to program this example. Delta PLCs are not something that I currently support. I do not have the hardware or software. Videos and posts take hours to produce. Do you have a specific question on this video that I could answer for you? Thank You, Garry
@georgealbo
@georgealbo Жыл бұрын
thanks for thi video , but where is the role of Shaft Encoder here and how to make use of it here
@ACCautomation
@ACCautomation Жыл бұрын
Hi George, The clock input is used to shift the data through the shift register. In our example, we will use the conveyor’s encoder to track the reject container. So each pulse of the clock represents a distance on the conveyor. Usually, this is attached to a shaft encoder or a proximity sensor detecting a gear tooth. The pulses represent a specific movement amount of the conveyor. Here is a link to the post that corresponds to the video. accautomation.ca/plc-programming-example-shift-register-conveyor-reject/ Regards, Garry
@georgealbo
@georgealbo Жыл бұрын
@@ACCautomation Thanks for your reply, so i can use a shaft encoder or a proximity sensor on a tooth.
@ACCautomation
@ACCautomation Жыл бұрын
@@georgealbo You can use a shaft encoder or a proximity sensor on a tooth. Keep in mind the frequency that this signal is giving to the PLC. Make sure that the PLC input can handle it. Regards, Garry
@SkyGamer911
@SkyGamer911 2 жыл бұрын
how to do this in ecockpit?
@ACCautomation
@ACCautomation 2 жыл бұрын
Hi SkyGamer, I have not used the Wago Ecockpit software, but I know it is compatible with Codesys 3. Here is a thread that discusses shifting bits using Codesys. www.plctalk.net/qanda/showthread.php?t=120750 Regards, Garry
@suriyat8773
@suriyat8773 2 жыл бұрын
Encoder motor converyet reject thankyou
@ACCautomation
@ACCautomation 2 жыл бұрын
You are welcome! I am glad this was helpful to you. Regards, Garry
@mahendraparmar9568
@mahendraparmar9568 3 жыл бұрын
Garry , Happy cristmas
@ACCautomation
@ACCautomation 3 жыл бұрын
You too!
@dhanush3732
@dhanush3732 11 күн бұрын
Shift Register - Conveyor Reject
@ACCautomation
@ACCautomation 11 күн бұрын
The bits shifted can be used for several different things. Tracking is the main thing explained in the video. accautomation.ca/plc-programming-example-shift-register-conveyor-reject/ Regards, Garry
@rickyrinaldy4885
@rickyrinaldy4885 7 жыл бұрын
sir,can you send me that file ladder logic and simulation,PLEASE!
@ACCautomation
@ACCautomation 7 жыл бұрын
Hi Ricky, You can download the free domore designer software at the following location: support.automationdirect.com/products/domore.html It comes complete with a simulator. Here is the program for the above: dl.dropboxusercontent.com/u/33455595/Conveyor%20Reject.zip I would recommend looking at the following for an HMI and PLC simulator: accautomation.ca/create-a-plc-with-hmi-training-and-learning-environment-free/ Here is another post that may be of interest: accautomation.ca/how-you-can-learn-plc-programming-without-spending-a-dime/ Thanks Ricky Garry
@rickyrinaldy4885
@rickyrinaldy4885 7 жыл бұрын
THANKS SIR, can you build ladder logic like conveyor metal detector in airport ?
@ACCautomation
@ACCautomation 7 жыл бұрын
You can take the same logic and apply to many different systems. The metal detector usually just stops the conveyor. So when the output comes on then the signal will be incorporated in the stop circuit. Regards, Garry
@rickyrinaldy4885
@rickyrinaldy4885 7 жыл бұрын
can you build that sir please, thank u in advice #sorry my bad english
@ACCautomation
@ACCautomation 7 жыл бұрын
I will not program that for you, but will help you out if you are stuck. The samples provided should get you started. Garry
@harshavardhana1382
@harshavardhana1382 7 жыл бұрын
thanks bro but can u explain with practically so that we can understand very clearly i am not demanding just i gave a suggestion k if anything wrong sorry
@ACCautomation
@ACCautomation 7 жыл бұрын
Hi Harshavardhan Please have a look at our website for a more detailed explaination. accautomation.ca/plc-programming-example-shift-register-conveyor-reject Thank you, Garry
@mahendraparmar9568
@mahendraparmar9568 3 жыл бұрын
Dear sir How to generate sequence block in program
@ACCautomation
@ACCautomation 3 жыл бұрын
Hi Mahendra, Sequencing in the program can be done in several different ways. Direct logic, timers, step bits, indirect addressing, etc. accautomation.ca/building-a-plc-program-that-you-can-be-proud-of-part-1/ The above post will show you how to program traffic lights in a few different ways. accautomation.ca/five-steps-to-plc-program-development/ This post will show you the five steps in program development. I hope this helps you out. Regards, Garry
@mahendraparmar9568
@mahendraparmar9568 3 жыл бұрын
THank you Gerry.
@ACCautomation
@ACCautomation 2 жыл бұрын
@Truth n Logic If you want to change the traffic light duration or time, it would depend on how the light control was programmed. If individual timers were used then you would just change that timer. With one-timer and comparisons, then you would have to change a few comparison rungs. Here are a couple of posts that will show what I mean by different ways to program the traffic light signals: accautomation.ca/building-a-plc-program-that-you-can-be-proud-of-part-1/ Here is a recent traffic light control using EasyPLC 3D simulator software. You will see that this will use the comparison method. accautomation.ca/4-way-traffic-light-plc-program-easyplc/ I hope this helps you out. Regards, Garry
@ACCautomation
@ACCautomation 2 жыл бұрын
@Truth n Logic This would depend on how the logic has been programmed. Here are some examples: accautomation.ca/building-a-plc-program-that-you-can-be-proud-of-part-1/ accautomation.ca/4-way-traffic-light-plc-program-easyplc/ I hope this helps you out. Regards, Garry
@shrinivasjoshi6386
@shrinivasjoshi6386 5 жыл бұрын
PROGRAMING IS NOT SET
@ACCautomation
@ACCautomation 5 жыл бұрын
Hi Shrinivas Joshi, I am not sure that I understand your question. What exactly is not set? Thanks, Garry
@shrinivasjoshi6386
@shrinivasjoshi6386 5 жыл бұрын
@@ACCautomation sir basically how to reset the programming
@ACCautomation
@ACCautomation 5 жыл бұрын
@@shrinivasjoshi6386 The shift register will continue to shift the information past the last bit. This information is then lost. If all of the items are removed from the conveyor, then we need to reset the shift register by the input X2. This will place zeros in the shift register. (Reset) I hope this helps you out. Regards, Garry
@shrinivasjoshi6386
@shrinivasjoshi6386 5 жыл бұрын
@@ACCautomation we will try out this thanks for your feedback sir
PLC Program Example - Paint Spraying
7:17
ACC Automation
Рет қаралды 14 М.
PLC Programming Example of a Process Mixer
8:26
ACC Automation
Рет қаралды 134 М.
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 31 МЛН
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 10 МЛН
Click PLC Shift Register Instruction
8:06
ACC Automation
Рет қаралды 13 М.
74HC595 & 74HC165 Shift Registers with Arduino
40:38
DroneBot Workshop
Рет қаралды 395 М.
Water powered timers hidden in public restrooms
13:12
Steve Mould
Рет қаралды 738 М.
PLC Shift Registers
13:49
WIT Solapur - Professional Learning Community
Рет қаралды 2,1 М.
PLC Basics: Ladder Logic
26:20
This is Automation
Рет қаралды 357 М.
Simple PLC Example Logic of Automatic Coffee Machine
10:29
Instrumentation Tools
Рет қаралды 3,6 М.
What Software do Mechanical Engineers NEED to Know?
14:21
Engineering Gone Wild
Рет қаралды 308 М.
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 31 МЛН