Plumbing Drain Pipe Assembly Ideas For Adding New Bathroom Behind Existing One - Part 1

  Рет қаралды 50,630

gregvancom

gregvancom

Күн бұрын

Пікірлер: 49
@gregvancom
@gregvancom 2 жыл бұрын
kzbin.info/www/bejne/bJXQiKOqbdyflc0 Here's a link to Part Two. Explaining how larger vents might need to be installed.
@shaundugan9974
@shaundugan9974 2 жыл бұрын
Thanks! This video is right on time! I'm in the brainstorming/planning process for doing this set up to do an ensuite in my master.
@gregvancom
@gregvancom 2 жыл бұрын
Glad it was helpful!
@Rosakru
@Rosakru Жыл бұрын
Me too... Excellent video. Thank you.
@arth.4196
@arth.4196 2 жыл бұрын
Greg, I have really enjoyed all your videos. I have only gotten permits where needed. But I sometimes watched a particular video 3 times to really understand. Then I asked plumber friends. Thank you so much. My home and my duplex rental.........
@gregvancom
@gregvancom 2 жыл бұрын
Yes, I've had to do the same thing. I don't always get it on the first try.
@ericramirez7051
@ericramirez7051 9 ай бұрын
You are the best 👌explained everything perfectly, answered all my questions. Now the best part is about to be done, I’ll be doing back to back new full plumbing at home.
@gregvancom
@gregvancom 9 ай бұрын
Great and thanks for the kind words.
@brianmcandrew9957
@brianmcandrew9957 2 жыл бұрын
Great video! Thank you for this!
@gregvancom
@gregvancom 2 жыл бұрын
My pleasure!
@alejandrorivera1782
@alejandrorivera1782 2 жыл бұрын
Great video! Thank you.
@gregvancom
@gregvancom 2 жыл бұрын
You are welcome!
@derekh6026
@derekh6026 Жыл бұрын
Very good video
@jirojosephesman8175
@jirojosephesman8175 Жыл бұрын
Great video.,. However my idea is instead of back to back , (saniflo is what I'm using) and the next room is a closet that will be turned into a bath and toilet.. How can I connect the vent and waste line .? Planning a walk in shower for both and change the tub on the previous bathroom.. Thank you have a blessed day and be blessed
@VP411Designs
@VP411Designs Жыл бұрын
Greatful for these videos, very helpful and easy to understand. Thank you. Based on your comment it may be a problem if you have a home with interior beams and perimeter footings, What is a good solution to get around this? Or workaround for adding plumbing with beam in the way? Or typically what is common practice used by professionals for this type of situation? Tunneling?
@gregvancom
@gregvancom Жыл бұрын
I don't have an easy fix for beams that might need to be relocated or floor framing modifications. You might find something helpful at our website in the crawlspace section.
@VP411Designs
@VP411Designs Жыл бұрын
@@gregvancom no I think the question was how to change existing plumbing drain line for example add a new drain line and need to connect to nearby drainline, but if you have interior beams is the only option to trench tunnel to the plumbing below the beams?
@gregvancom
@gregvancom Жыл бұрын
@@VP411Designs You can usually access plumbing from above by removing concrete or flooring, but it can be accessed by removing soil also if easier.
@VP411Designs
@VP411Designs Жыл бұрын
@@gregvancom thank you
@1ong1337
@1ong1337 Жыл бұрын
would it be possible to add a 3rd fixture (washing machine) on top that double lavatory wet vent?
@kylelwiley9743
@kylelwiley9743 Жыл бұрын
I have a crawl space under my home. Am adding a new bathroom & will be 20' from main line. When adding fittings to main line, Can you use a slip coupling & mark the pipe for maximum glue area ? Your video is excellent, The part I am trying to understand how you got the fittings on the main line without movent of either end of existing main line. And the dimension for center of toilet drain from finished wall is12.5 inches ?
@gregvancom
@gregvancom Жыл бұрын
It make sense.
@m3xicano4ever
@m3xicano4ever 2 жыл бұрын
For the bathtub could you have done a double sanitary tee?
@gregvancom
@gregvancom 2 жыл бұрын
Most plumbers won't do it, because it can create problems when trying to run a drain cleaning snake through on side and hoping it will turn and go down, but instead comes out the other side. Maybe a double fixture tee might work, but you would need to check local building codes to verify.
@joseartiaga3048
@joseartiaga3048 2 жыл бұрын
Question why is the waste of the lavatories at an angle and not coming out straight out?
@gregvancom
@gregvancom 2 жыл бұрын
Some times it works better for the waste pipe installation. You shouldn't have a problem hooking up the sink drain as long as the pipe angle is correct.
@regularguy9264
@regularguy9264 2 жыл бұрын
You can’t use a sani-T in a horizontal application. They must be a wye fitting or something similar.
@gregvancom
@gregvancom 2 жыл бұрын
Exactly and good point.
@regularguy9264
@regularguy9264 2 жыл бұрын
@@gregvancom good idea for a video. Pretty common scenario
@gregvancom
@gregvancom 2 жыл бұрын
@@regularguy9264 Are you referring to the combo fitting I mentioned in this video and the one I did not refer to as a santee?. This is why I mentioned it, because it might have been you who didn't like my combo fittings design on one of my other videos.
@regularguy9264
@regularguy9264 2 жыл бұрын
@@gregvancom I don’t believe I commented about this on another one of your videos. I do enjoy watching them though. I was actually referring more to the illustration used than any wording that you used. I noticed you used the wye fitting as well as a sanitiee next to each other with both being horizontal in the video (at 5:53), and just thought it was worth mentioning.
@DudeTastic13
@DudeTastic13 2 жыл бұрын
Kind of a silly question, but are you going to put in a window for your new bathroom?
@gregvancom
@gregvancom 2 жыл бұрын
Not silly and you can have a window or exhaust fan usually approved by most building codes.
@nathanmurdock9481
@nathanmurdock9481 2 жыл бұрын
It’s like you can read my mind!
@gregvancom
@gregvancom 2 жыл бұрын
Magic:)
@bobrub
@bobrub 2 жыл бұрын
3" main drain to 3" W.C. combo/cross = 3" vent stack thru the roof, cannot be 2".
@gregvancom
@gregvancom 2 жыл бұрын
Thanks for sharing and good point, check with local building codes for vent sizes. If you have the building code reference number for the full size 3 inch vent, I would love to see it.
@bobrub
@bobrub 2 жыл бұрын
@@gregvancom 815 KAR 20:090. Soil, waste, vent systems, traps, and clean-outs. ....... (from 2020 Kentucky State Plumbing Law,Regulations and Code Book pg. 70) Section 11. Soil and Vent Stacks. (1) A building in which a plumbing fixture is installed shall have a soil or waste and vent stack, or stacks, extending FULL SIZE through the roof. Other national codes follow this same principle.
@gregvancom
@gregvancom 2 жыл бұрын
@@bobrub I was wondering how you would reply, other national codes follow this same principle, when in fact the other side is that some don't. I appreciated the code reference number, because it will help others, including myself who needs to do a better job pointing out where I'm getting my information from. International plumbing code book 2021 reference number 906.2 say that you can use half the diameter of drain served. Thanks again
@bobrub
@bobrub 2 жыл бұрын
​@@gregvancom Hi Greg, KY code is really all I know but your reference to IPC 906.2 got mr curious. That 906.2 section is titled "Vents OTHER THAN stack vents or vent stacks". Your plan was for a 3" main waste drain, a 3" waste stack (serving 2 - 3" W.C's), with a 2" stack vent. Section 913.3 Stack vent says ....... "A stack vent shall be provided for the waste stack. The size of the stack vent shall be not less than the size of the waste stack." ...... which is 3".
@gregvancom
@gregvancom 2 жыл бұрын
@@bobrub I would think this section (913) is referring to more than one story with a vertical stack, like a house with a basement and one floor above or two story house where you might need the same diameter pipe for vent as waste. Every drawing I saw referring to a stack vent had all of the plumbing drains for a single bathroom on each separate floor going into one main vertical soil and waste stack, unlike my design that had three pipes going into the horizontal waste drain with three common vents. I have a question, would you need to run a waste stack if you had a drain pipe layout like this?
@hasanakdag6447
@hasanakdag6447 2 жыл бұрын
❤😊❤😊❤
@gregvancom
@gregvancom 2 жыл бұрын
Awesome.
@TedWoodruff-e2l
@TedWoodruff-e2l Жыл бұрын
in 2050 the pipes may be $40,000 each, LOL You may be right.
@bradhaenitsch1145
@bradhaenitsch1145 Жыл бұрын
First of all drain the tub’s on opposite ends. Make’s life much easier
@gregvancom
@gregvancom Жыл бұрын
I don't always agree with that, whether of not your right or left handed could make life much easier for turning on bathtub water supply valves.
How To Plumb A Bathroom In 20 Minutes! - Beginners Guide
20:55
The Excellent Laborer
Рет қаралды 1,8 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
Plumbing a bathroom explained in 4 minutes. [You CAN do it!] #diy #plumbing
4:20
Rising Tide Plumbing
Рет қаралды 678 М.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
How To Plumb a Bathroom (with free plumbing diagrams)
6:18
Hammerpedia
Рет қаралды 6 МЛН
Connecting to the live soil stack - new toilet (part 4)
27:04
Gosforth Handyman
Рет қаралды 80 М.
Abandoned Wood Shed - Complete Renovation Start to Finish Timelapse
23:34
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН