Looks like you will be back installing that air scope, lots of air in that system when not installed correctly!
@ChuckBarron4 жыл бұрын
for sure.
@xcmskim44 жыл бұрын
Would love to see a video on you installing the air scope. Nice job!
@ChuckBarron4 жыл бұрын
Coming soon! Next heat call I will have material on truck. ha.
@pb99264 жыл бұрын
Nice one Chuck 👍
@ChuckBarron4 жыл бұрын
Glad you enjoyed it
@assimilationdesignlabllc44542 жыл бұрын
What causes a high pitch ring or whistle when the boiler comes on? Its a brand new crown unit.
@hmdwn2 жыл бұрын
Looks like I have the same Crown gas boiler... only on it's 4'th year and throwing a code 4 error. Short cycles a few times, the error code goes away and then seems to run as should.
@kennethharris6379 ай бұрын
I had NO IDEA my favorite KZbin plumber was from my state! WTH. If I don’t figure out this crown boiler soon I’m calling!
@brewmule67994 жыл бұрын
Hey Chuck, don’t get Old Glory wet! 🇺🇸
@ChuckBarron4 жыл бұрын
Attention!!! Sir Yes Sir.
@JamesBrown-db9pk4 жыл бұрын
fix it up old chucker or call lav he got his trk bak agin up and rolling
@ChuckBarron4 жыл бұрын
roll with me James. We have a few laughs....we will call stevie boy up.
@garyb6220Ай бұрын
Where is the water level sight
@foodtaster43583 жыл бұрын
Is 20 psi bad ?
@JE278984 жыл бұрын
It sucks when a guy push-pulls a boiler. Also, no code update. Then, when you come in to fix, you have the responsibility to break the bad news. They should be glad you're there Chuck.
@ChuckBarron4 жыл бұрын
I was glad to get er done.
@charlespelletier96214 жыл бұрын
That needs air separator like a spirovent. And the expansion tank is not upside down. That is its position when installed on a scoop. Also is that a galvanized nipple on the water line after the auto fill valve. Of so thats a no no where I'm from. Inspectors or gas company would red flag the boiler for that. Especially being on the potable side.of the backflow
@ChuckBarron4 жыл бұрын
all true.
@tomhman64414 жыл бұрын
How long are we going to watch a system empty out?
@ChuckBarron4 жыл бұрын
lol....thanks tom
@polarbear17544 жыл бұрын
Wouldn't it be nice if the customer cleared the area around the boiler? It's tight enough in there without having to fight through and past obstacles.
@ChuckBarron4 жыл бұрын
so true. a time killer.
@mikev.10344 жыл бұрын
👍👍
@brewmule67994 жыл бұрын
Mikey in da house!
@ChuckBarron4 жыл бұрын
Yes sir.
@ChuckBarron4 жыл бұрын
Brew in da house!
@OSCARANDRES0394 жыл бұрын
My mothers apartment has 6 radiators but only 2 that are actually working. The other 4 have been turn off at the valve because they make her apartment to hot and also make alot of noise. Banging all day and night. Would it be bad for the boiler or the pipes themselves just having the 2 radiators working ?? Would this cause problems to the rest of the pipes and boiler,mm Note.. I did tilt the banging radiators several inches but it did not make any difference in the. Noise. So I turn those 4 off. The crown boiler is has an 85,000 BTu output and a 103,000 BTU input. Currently working nicely. I drain all the water this weekend and fill it back up. unclog the sight glass, pigtail and the pressure gauge. I lower the pressuretrol settings to 1.5 PSI on the main and .5 on the differential. This boiler heats up a second floor apartment. Do you think these are the right settings?? I would really appreciate your input on this. Thanks you.
@ChuckBarron3 жыл бұрын
Is it a steam boiler?
@dannywilkins8874 жыл бұрын
Wow that’s a real hack job
@ChuckBarron4 жыл бұрын
some tlc get that joker back in line.
@H2ghsky2Jojo4 жыл бұрын
I’m Sorry ☹️ And For Your Video and With my Video Music 🎶 JOJO Beckers’s
@ChuckBarron4 жыл бұрын
your music paid for from Epidemic player. Thank you for some tunes for the vids brother.
@zakkmon1234 жыл бұрын
👍🏻🤙🏻!
@ChuckBarron4 жыл бұрын
ya dawg.
@CigarBoss_3 жыл бұрын
I thought boilers where HVAC related
@Martin-pr6ps4 жыл бұрын
Another inefficient boiler that's not piped correctly.
@ChuckBarron4 жыл бұрын
true that martin
@edp97434 жыл бұрын
Why do people pack so much crap around their mechanicals? No realization of fire hazards and ease of service.
@ChuckBarron4 жыл бұрын
so i can trip and fall all over the place
@Richard-qg7sz4 жыл бұрын
I know who installed this boiler
@timlu697 Жыл бұрын
Do not buy this junk boiler this is a garbage boiler keep breaking down .