Running a sewer line part 1 parts and pipe

  Рет қаралды 180,222

Plumbing Solutions, LLC

Plumbing Solutions, LLC

Күн бұрын

Пікірлер: 76
@willie4life96
@willie4life96 Жыл бұрын
Good video. For some reason I watched to the end lol. I am a master plumber and always learning 23 years doing plumbing now.
@mr.nguyen3222
@mr.nguyen3222 8 ай бұрын
I can tell you enjoy your job. That's admirable.
@tytar1037
@tytar1037 10 ай бұрын
Where I am, the city just leaves you a sewer stub that comes from the main. Gotta measure and figure out where it is and dig for it. Gotta go down in a deep hole to hook on to it. Sometimes the stub is under a finished driveway. The way your city does it is WAY easier.
@jamesdorsey1686
@jamesdorsey1686 Жыл бұрын
Thank you for the hard to find details, great work.
@Hamp3333
@Hamp3333 5 ай бұрын
Really cool you can tell he has been doing new residential construction plumbing
@Hatchman33
@Hatchman33 Жыл бұрын
Great info! Love your videos! I am starting a wet and dry utility company and this is super helpful!
@medsip
@medsip 11 ай бұрын
Great Video! Very informative and helpful.
@mark_Hershey
@mark_Hershey 2 жыл бұрын
Always fun to see different codes. I’m a plumbing contractor in ky…”jammer”, we call them all threads. Dumb reason on the inspectors part for not allowing them. Green pipe is sdr 35 around here, just found out it also called 3034.
@markchriestenson3257
@markchriestenson3257 2 жыл бұрын
I've run a 100' sewer clean out machine. 100' foot of cable minus your vertical drop from your clean out. So a 3' down drop and then 97' of lateral run. So probably a good rule of thumb is every 90 feet between clean outs. But that gets shorter the deeper you go. I did a church one time and it had roughly 400 feet of sewer line between the building and the sewer tap. By the time I was in the last clean out, I was probably about 6 feet or more deep, and i had to get a bigger machine.
@BigFrizzGaming
@BigFrizzGaming Жыл бұрын
Im a drain cleaner and have been for 2 years & I'm 18 about to try plumbing out. I'm glad to see people who understands this stuff 😂
@nickneurohr5422
@nickneurohr5422 Жыл бұрын
We use trailer keys for anything over 200 feet
@fidelindigenousbrother6612
@fidelindigenousbrother6612 2 жыл бұрын
I literally just subscribe to you channel and loving it Soo far.
@MeltinMetalAnthony
@MeltinMetalAnthony 2 жыл бұрын
Another excellent video! Thanks
@zzrx7
@zzrx7 3 жыл бұрын
great video! very informative and helpful, Thank You sir!
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 3 жыл бұрын
Glad it was helpful!
@travismccarthy5681
@travismccarthy5681 2 жыл бұрын
Awesome video man! Very educational!
@buddyrevell511
@buddyrevell511 6 ай бұрын
Absolute gold. Thank you!
@iz1885
@iz1885 Жыл бұрын
Hi buddy. You're a sewer knowledge king👍👍
@overviewhd4370
@overviewhd4370 3 жыл бұрын
I run sewers for a living good video different codes here in Texas
@blownonfuel
@blownonfuel 2 жыл бұрын
Where could I find Texas plumbing codes? Need to help my father in law replace the sewer line that goes from the house to the city tap. He can't afford to hire someone unfortunately.
@smiggetysmackems379
@smiggetysmackems379 3 жыл бұрын
Can’t wait for part 2!
@hiibeyonewneigba
@hiibeyonewneigba 2 жыл бұрын
Great explanation of the basics, thank you for this!!
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 2 жыл бұрын
You're very welcome!
@karstensalin7230
@karstensalin7230 3 жыл бұрын
Using a Sanitary instead of a 2 way long T for a clean out make sense in this case because it come right after a flapper valve. If the clean out worm was used towards the house, (up stream), it would damage the flapper.
@affordabledesertliving3487
@affordabledesertliving3487 2 жыл бұрын
Great info bud. My sewer line is only going to run about 50 feet from the toilet tot he septic tank. That said I am still thinking that putting any 45 deg connections should be avoided. Anyone have any experience with this size of a line and what they think? Thanks. Oh and I dont have any codes believe it or not. I am rural in SE Arizona.
@eltuntun2682
@eltuntun2682 2 жыл бұрын
In California a clean out is required at every 135° turn or 100’ of pipe run.
@DavidMitchell-o8h
@DavidMitchell-o8h 5 ай бұрын
Holy shit
@EduardoHernandez-pq6mx
@EduardoHernandez-pq6mx 2 жыл бұрын
Amazing video!
@Emezepe3
@Emezepe3 2 жыл бұрын
Is there a video of excavation process, reading grade stakes to determine how much you need to cut after adding bedding and pipe thickness
@kylarochelle4583
@kylarochelle4583 Ай бұрын
Following!
@borishranowskyj2105
@borishranowskyj2105 2 жыл бұрын
Great video!
@bp4170
@bp4170 3 жыл бұрын
"I'm gonna hate ya". Love it. Thanks for sharing your knowledge.
@khaleefax9553
@khaleefax9553 3 жыл бұрын
*OK, so for my floor drain under the basement floor, that will take all the waste water outside the building and dump it into the sewer line, I am thinking to put a 5 inches schedule 80 pipe under the basement floor. Cost doesn't bother me. Are there any drawbacks for this application? I just wanted to have a stronger and wider pipe under the floor so I, hopefully, never have to dig the basement floor to treat the broken or narrow pipe.*
@robertobarajas9894
@robertobarajas9894 3 жыл бұрын
Great video I subscribe thanks.
@fidelindigenousbrother6612
@fidelindigenousbrother6612 2 жыл бұрын
Very informative
@mrdv107
@mrdv107 3 жыл бұрын
Great video…Can I run a water line in the same trench as a astm d 1785 schedule 40?
@davidmize8489
@davidmize8489 2 жыл бұрын
No
@eltuntun2682
@eltuntun2682 2 жыл бұрын
Not in California. 12” different elevation.
@tonytrinidad4409
@tonytrinidad4409 2 жыл бұрын
2ft distance minimum in any direction in Texas
@DaniilStanisevschi
@DaniilStanisevschi 11 ай бұрын
How do you make the backwater valve accessible for maintenance? What's your areas lateral line burial depth? In MN everything is 6-10' deep and we keep all of this "maintenable" stuff inside the basement before the foundation wall.
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 11 ай бұрын
I'm in SC it's only 12 inches here
@DaniilStanisevschi
@DaniilStanisevschi 11 ай бұрын
@@PlumbingSolutionsLLC that's got to be nice for repairs. Thanks for making such a detailed video. Have a blessed day!
@neilsolano8874
@neilsolano8874 Жыл бұрын
Wait I need to know… so you just slip in the pvc into the green 3034 bell end??? With same glue??? There’s no difference??? I’ve looked everywhere trying to find how to connect dwv to sdr 3034 together!!!! Your telling me this whole time there’s no difference ?
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC Жыл бұрын
no there is an adaptor.
@neilsolano8874
@neilsolano8874 Жыл бұрын
@@PlumbingSolutionsLLC is there any way you can tell me where to find this adapter. Or atleast what it’s called to search it? I’m desperate.
@bmack2938
@bmack2938 Жыл бұрын
I found it at Home Depot. You can grab a short length pvc schedule 40 and the green sdr and see what fitting works. I’m going to had today and I’ll post the item number and name of the fitting.
@jonathangray6563
@jonathangray6563 2 жыл бұрын
Great job! Thanks
@JustJanitor
@JustJanitor 2 жыл бұрын
WOW! That sewer turn off is nasty as heck. For God sakes I get people gotta pay they're bills but damn. Yeah I agree that is just wrong.
@howardmullings7047
@howardmullings7047 3 ай бұрын
Very helpful thank
@bmack2938
@bmack2938 Жыл бұрын
Maybe a dumb question. Why is the pvc loose inside the 3034? How is that connection made? I just dug up where I’m tying into the existing 3” pvc and it’s right before the 3034 connection that goes another 100’ to the city sewer line. I noticed the pvc is loose inside the 3034. Doesn’t seem normal to me since it allows dirt inside the 3034. Any help is appreciated.
@saltwaterinmyveins
@saltwaterinmyveins Жыл бұрын
Late reply, but you will need a transition fitting to fix it properly.
@bmack2938
@bmack2938 Жыл бұрын
@@saltwaterinmyveins turns out the 3034 was a sleeve. PVC runs all the way out the the city 8” pvc line. Inspector said because the back of lot was never cleared of old growth hardwoods the pvc was sleeved because of the roots.
@KaceyMotley
@KaceyMotley 6 ай бұрын
That elder valve is some dirty sh!t - Sometimes you just can't pay your sewer bill. You should be able to take a crap at home without having to go to a gas station. Oh well, pay your bills people. That's one bill you don't want to compromise with :P
@cesarjarillo7736
@cesarjarillo7736 7 ай бұрын
What type of lisence do you need to do this on your own separate from the apprentice rui endorsement
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 7 ай бұрын
In SC you can run your "own" sewer line without a license.
@davidmize8489
@davidmize8489 2 жыл бұрын
You show a street 45 but you don’t use one on the clean out? Had a whole discussion about cutting a stub. Kinda missed one here lol.
@Atr42Greasemonkey
@Atr42Greasemonkey Жыл бұрын
3 inch diameter pipe in the floor f the house or 4 inch?
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC Жыл бұрын
3 step up to 4 after the 4th toilet.
@Atr42Greasemonkey
@Atr42Greasemonkey Жыл бұрын
@@PlumbingSolutionsLLC Thanks bud.
@vroor32
@vroor32 Жыл бұрын
​@@PlumbingSolutionsLLCwhy not just go 4" all the way and be done?
@cornpop7805
@cornpop7805 2 жыл бұрын
I believe the 4 or more toilets for 3" is in the UPC, but most of the eastern United States uses the IPC code, which allows something like 16 toilets. I'm not certain, but this is how I think it works.
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 2 жыл бұрын
We use IPC in SC, it's footnote d on table 710.1(2) it was an addition to the 2018 code. 3" can service no more than three water closets.
@jiggidyjam
@jiggidyjam 2 жыл бұрын
I hate those back flow preventers. I use sewer poppers when I can
@sergioduran8948
@sergioduran8948 3 жыл бұрын
What schedule is your pvc pipe ? What is cheaper ABS pipe or PVC pipe? Thank you
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 3 жыл бұрын
sch 40 , cell core PVC is cheaper. Due to volume sold, solid core PVC is cheaper than ABS at most supply houses. Or you can use 3034 (the green pipe) it's going it be the cheapest.
@nickneurohr5422
@nickneurohr5422 Жыл бұрын
Back water valves don't work once the resident uses water, it's gonna open the flapper and water still gets released into home, they never work
@danebeardsley
@danebeardsley 3 жыл бұрын
super helpfull
@yhernandez7275
@yhernandez7275 3 жыл бұрын
Hello sr!! If I were to do a slab to sit my mobile what can I leave under ground??
@PlumbingSolutionsLLC
@PlumbingSolutionsLLC 3 жыл бұрын
I wouldn't put anything under ground. you will still have a crawl space.
@brady0630
@brady0630 3 жыл бұрын
solid video
@ttny60
@ttny60 2 жыл бұрын
Great video. Very informative and precise. Thanks
@BBQ_Burrito
@BBQ_Burrito 2 жыл бұрын
Thanks
@davidmize8489
@davidmize8489 2 жыл бұрын
Dumping into that vertical would never fly most places I have worked in my 48 years of doing this. I guess that’s why they want it extended as a clean out but why create that obvious trouble spot? Odd. P. S. What’s a fittin? Lol
@joshcowart2446
@joshcowart2446 2 жыл бұрын
I don’t understand the logic behind not allowing hub to hub. We call that a butt up in Austin. When I came up in west Texas we called it an all thread. This was based on a close nipple which is all threads. As for threaded rod, we called it ready rod so there wasn’t any confusion. Anyway I digress. The logic was inspectors didn’t like it because he can’t tell how long the piece of pipe is. How is that different from every other glue joint. He can’t tell if they’re all the way up either. Also who cares. It’s getting tested so if the pipe is too short it will leak. I can’t imagine plumbing a house without using a butt up. It sounds to me like you have a stupid and stubborn inspector which sucks. I hate when inspectors flag me on stuff that’s not wrong. I hate having to fix stuff that’s not broken or trying to figure out if it’s better to just do it the way he wants or to question him. Inspectors are just like plumbers. They don’t have the code book memorized and sometimes they’re wrong. Most of them don’t have ego issues so if you make a case they’re good with it. Then there’s those few who don’t like being questioned. We have one who will nit pick you to death if you aren’t there when he inspects it. If you’re there an shoot the shit with him, he’ll let lots of stuff go. I had some pipe 2” off the stud face. He said I needed nail plates. I fixed one thing he was correct on and recalled the inspection. The second time I was there. I was ready to measure and show him but he never even looked at them that it didn’t need nail plates. He checked the one thing and passed it without even asking or looking at the pie through the studs
@sandeepplumbersandeep3943
@sandeepplumbersandeep3943 2 жыл бұрын
Plumber joB help
@andresvasquez7752
@andresvasquez7752 4 ай бұрын
amazing
Running a sewer line part 2 Piping
27:45
Plumbing Solutions, LLC
Рет қаралды 153 М.
How to replace a main sewer line for ONLY $490
9:58
CreativeProcessDIY
Рет қаралды 206 М.
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН
IL'HAN - Qalqam | Official Music Video
03:17
Ilhan Ihsanov
Рет қаралды 700 М.
Your Septic System: Worst Mistakes
16:44
Sachs Realty
Рет қаралды 1,8 МЛН
House Sewer Connection To Main Sewer: A Riser Connection Explained
4:03
Balkan Sewer & Water Main Service
Рет қаралды 25 М.
Getting the Correct Pitch for Drain Lines
4:04
James Glass
Рет қаралды 90 М.
SEWER PIPE INSTALL
6:55
Pushysix®
Рет қаралды 149 М.
How to INSTALL Your OWN Septic Tank | Septic System Install | Part 3
18:10
Deep South Homestead
Рет қаралды 1,3 МЛН
Installing Water And Sewer Lines
18:52
Elite Earthworks LLC
Рет қаралды 112 М.
How To Vent & Plumb a Toilet (in 2024)
6:59
Hammerpedia
Рет қаралды 2,6 МЛН
Rough in plumbing basics for under a slab.
8:08
Bevins Builds
Рет қаралды 326 М.
Plumbing Slope Rule and Why it is CRITICAL
10:08
Todays Task
Рет қаралды 139 М.