Пікірлер: 32
@The_Train_Manager
@The_Train_Manager 4 жыл бұрын
Bahot umda video..... 😘 😘 Jra mujhe ek bat bataiye... Is point ko install krnewale maintain krnewale ko priority honi chahiye ya operate krne walo ko?? Kyu itni technicalities hone k bawjud v ESM ki joining 1900gp se hoti hai jabki SM ki joining 4200 pr... Pura operations jab signaling pr depend hota hai to signal staffs ko neglect kyu kiya jata ha... Kyu branch line me ek station pe ek ESM ek helper hote hain jab ki 3 SM, 3 TP, ek to smr v hota ha kahin kahin pr... Akhir itna ganda haal kaise bana signalling deptt ka??? Mere seniors bolte hain phle ek SIGNAL MAINTAINER ki salary SM se jyda hoti thi... Phir aisa kya aur kyu hua ki hmari position km hoti gyi... Jb ki jimmedariyan badh rgi hain... Phle signal maintainer grade 2 se aate the the.. Mere seniors v grade2 se aaye hain... Fir avi grade3 se kyu liya gya ha jab ki phle 2800gp se ane wale asst station master wo pad khtm kr k sidha 4200gp pr aa rhe hain... Sab ki roster shift hai 8 hrs ki... To signal staff ne koun sa jurm kiya hai ki inhe 24 hrs de dete ho... Is 24 hrs hone k chakkar me wo NDA aur dusre allowances se wanchit rah jata hai... Aur behad km salary milti hai... Savi technicians 6 month me posted ho jate hain jab ki hmari training 1 saal ki hoti hai... Kyun?? Jab hmara work profile hmari jimmedariyan dusre technicians se alag hai to hmara payment structure v alag krayi jaay🙏🙏🙏🙏🙏
@prajatkabhosale
@prajatkabhosale Жыл бұрын
सुंदर व्हिडिओ
@srinivas1878
@srinivas1878 3 ай бұрын
What is the tolerance of openings? If tolerance out of range what will happen?
@Er.narendramaurya
@Er.narendramaurya 6 ай бұрын
❤❤
@SUBODHMINJ-h7s
@SUBODHMINJ-h7s Жыл бұрын
Thank🙏💕🙏💕 Sir.
@srinivas1878
@srinivas1878 3 ай бұрын
Please explain about friction clutch preventive maintenance..
@aruproy8793
@aruproy8793 3 жыл бұрын
But how do the tracks change. What is the mechanism.
@ennovatenext2212
@ennovatenext2212 5 жыл бұрын
Sr ye konse batch and divisions ki training chal rahi hai??
@riyaarthduniya
@riyaarthduniya 5 ай бұрын
supply cut hone ke baad bhi moter reverse chal ja rahi hai.. na chale rokane ka koi solution ho to bataye plz
@sunitkumar6101
@sunitkumar6101 5 жыл бұрын
Apne 143 mm Ke stroke me 115mm opening 25mm lock aur 3mm indication pressure ke liye bataya acchi bat hai. Lekin Jaha opening 100 ,105,110 ho to stroke 143 mm kaise kaise adjust hoga. Jara is bat par Prakash dalne ka prayash kare. Thanks.
@rockinggamer8112
@rockinggamer8112 2 жыл бұрын
waha idle strock 25mm se jyada hoga
@dharmendrakashyap2764
@dharmendrakashyap2764 Жыл бұрын
Point machine ke 110 DC voltage kam hone per kahan se badha sakte hain
@akshayudawant
@akshayudawant 2 жыл бұрын
143 mm ka to samajh aa gaya lekin, 220 mm stroke point machine ka distribution kaise hota hai...
@singwithsoul-bp3qg
@singwithsoul-bp3qg 4 жыл бұрын
बीच बीच में रुक क्यों जाते है सर बताते टाइम,,,be confident
@ishtiyaqmunavary8797
@ishtiyaqmunavary8797 4 жыл бұрын
point machine motor ke bare details milega kya..
@DineshKumar-bu9vw
@DineshKumar-bu9vw 2 жыл бұрын
Tsr LR sR circuit ke bare mein jankari den
@ashokbhati5790
@ashokbhati5790 5 жыл бұрын
Thanks sir ji
@railwaysignallingsystem7033
@railwaysignallingsystem7033 4 жыл бұрын
RESPECTED ALL CONCERN SSDAC ELDYNE ERROR CODE H4/H8-1/2 STEADY/FLASHING THEN WHAT ACTION CAN BE TAKEN.
@birjushaw6144
@birjushaw6144 3 жыл бұрын
There are many steps to solve this type of problem.This type of indication may be due to communicatio problem,DP hand,Card problem or may be due to defects in track devices.
@jaspalrawat4392
@jaspalrawat4392 3 жыл бұрын
बहुत सटीक वीडियो
@ShaktiSingh-ks7ky
@ShaktiSingh-ks7ky 5 жыл бұрын
Thanks sir jii
@MDAuwal-yj5hl
@MDAuwal-yj5hl 2 жыл бұрын
Barcode ka tar hota hai to Ham tar lagaenge kis tarah ke laenge kaun sa defence mein kaun sa normal hai ka number kahane wala number ke sath humko bataiye
@biren8999
@biren8999 4 жыл бұрын
Sir b24 au n24 use kiya hai samjh Mai nahi aaya
@The_Train_Manager
@The_Train_Manager 4 жыл бұрын
+ and - supply hai b for positive 24v,n for negative 24v.. Controlling and indication circuit k liye
@1014santosh
@1014santosh 4 жыл бұрын
Thank u sir please DLBI mey failure honey sey kaisey dekthey hey thoda explain kijiyey
@lakshadipmankar1742
@lakshadipmankar1742 4 жыл бұрын
throw rod ki chal 143mm bola hai isme chal matlab in english kya hai
@KartikeyaSharmakt
@KartikeyaSharmakt 4 жыл бұрын
@@lakshadipmankar1742 Length
@moviesmania836
@moviesmania836 4 жыл бұрын
Sir plz IRS rod ki detail bataye
@abhi22795
@abhi22795 Жыл бұрын
Koi mujhe IRS ka full form batao please. TWS ka to pta hai.
@mohitgurjar7822
@mohitgurjar7822 4 жыл бұрын
wiring bhi batae
@rajeshkumarsingh4181
@rajeshkumarsingh4181 4 жыл бұрын
Bhai wiring hi to bata rhe h sir
Electronic Interlocking
14:18
STTC GZB
Рет қаралды 10 М.
Data Logger
15:59
STTC GZB
Рет қаралды 22 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
IRS TYPE POINT MACHINE
10:07
STTC GZB
Рет қаралды 44 М.
Point machine. IRS type point machine. working of a point machine
6:16
HR/DR Circuit   ...... Signal Lamp Circuit/signal control circuit
16:51
Signal Engineering IR (SEIR)
Рет қаралды 2,4 М.
The secret tool that experienced welders are hiding!
5:23
Musiy4uk
Рет қаралды 50 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН