this is a video on how we do our pool earthing at Pro Image Electrical #poolearthing
Пікірлер: 15
@michaelcostello6991 Жыл бұрын
Great video. Clear detailed explanation. Thanks
@andymc8355Ай бұрын
With a fibreglass pool, do you need to earth the reo bar inside the concrete surrounding pad of the pool..?
@bertmonkey8457 Жыл бұрын
Glad I watched this video, the pool company and the concreters have said nothing about earthing... Just spoke to the sparky and "Oh yeah it got to be earthed!" lucky we haven't poured the concrete around the pool yet!
@felixxr6turbo Жыл бұрын
Do you consider an aluminium fence that’s screwed together as electrically continuous? As in you can earth one end and you’re golden?
@battlinglefty93015 ай бұрын
My electrician said he wants to run the earth to the switch board. I should be able to save some $$ and have him just terminate at the filter circuit then. 👍🏻
@bernardrobinson8372 жыл бұрын
Thanks for the video. If you use a non conductive grout around the spigot do you still require the earth bonding of the spigot.
@proimageelectrical5295 Жыл бұрын
You can use a non conductive spigot
@bronwynandroyadventurers30662 жыл бұрын
G'Day. How do you keep the spigot fixing slurry out of the 20mm conduit?
@proimageelectrical52952 жыл бұрын
Hi The cable gets buried in the slurry
@viktorase Жыл бұрын
Hi, What about the pool itself? Shouldn't you earth the pool concrete structure reinforcing steal mesh too? Cheers. Viktor
@proimageelectrical5295 Жыл бұрын
Yes that also is earthed
@viktorase Жыл бұрын
I bought a property with a old concrete pool. Every time when I was kneeing at the side of the pool on the concrete path to clean the simmer box and had a little cut on my hand I had an electrical shock. I thought that the pool was not grounded properly, so ran a new 6mm earth cable from the earth steak to the pool shell rebars. It was still doing it. Than I replaced the earth steak to a 16mm 4m long steak. Nothing changed. Finally I worked out the issue. The concrete path steel meshes around the pool weren't grounded at all. I had to break up the path to find the meshes at least 15 places. Of course they didn't tie the meshes together when they did the concreting. Since I grounded all the meshes together to the pool bonding it stopped electrocuting me. The videos like yours truly help people. Thank you.
@royaliptv Жыл бұрын
Thanks for the video but how do you test the earth if it's good or not?
@mattwoods8907 Жыл бұрын
With a meter 0.5 ohms no greater resistance than that
@ryandelong27598 ай бұрын
The Northern Han Neanderthal crime family has been marked for extermination. Psalm 21 KJV