I've watched this video multiple times and share it to a Facebook pressure washing group religiously to guys having problems with their burners. Perfectly explained, visuals are perfect. Top notch sir!
@daftnord49573 жыл бұрын
Whats the group called? I just got myself an used landa pgh w that doesn't heat, looking to learn more about heated washers in general
@zodglubby2 жыл бұрын
I have a hotsy, no fuel at the small fuel transfer line. He says troubleshoot up the line what does that mean?
@travisclarke92142 жыл бұрын
@@zodglubby there should be a fuel bleeder screw, you may have air in your line if its not getting fuel. If not likely the pump is shot
@travisclarke92142 жыл бұрын
@@daftnord4957 sorry man, didn't see this till now. Im in a kitchen exhaust cleaning group
@brucebreisch5593 Жыл бұрын
One of the best troubleshooting videos I have seen. Keep up the good work.
@firestone6774 жыл бұрын
Thank you!!!! 40 years industrial Mechanic supervisor, first time working on a pressure washer. thank you thank you :-)
@justinglover40587 ай бұрын
😅 if
@matth7597 Жыл бұрын
Thank you for saving me money and taking the time to make this video sloot to you sir
@JT-gw9gz3 жыл бұрын
Exceptionally well done, thank you very much. Your delivery was great, metered, and well annunciated.
@Powerwash3 жыл бұрын
Thank You, JT
@petrapalomares40862 жыл бұрын
Hi I’m looking for a burner for hx series pressure washer /steam cleaner any suggestions where to buy one or do you know any place do I can buy one thanks and your videos are great by the way hope I hear from you soon great life for you and your family
@Powerwash2 жыл бұрын
That would be a Hydro Tek. Check out there website they have several distributors that should be able to get you what you need.
@clearlake23693 жыл бұрын
How exactly does pulling the trigger on the pressure wand activate the burner, thanks for the very clear and informative video!
@Powerwash3 жыл бұрын
It triggers a microswitch which then completes the circuit for the burner to ignite.
@ErikISkogen9 ай бұрын
Really easy, and stright forward. Thank you sir.
@JoseHernandez-qk5by Жыл бұрын
Hi Sr... I have a north star water heater.... as in your video fire should go off once the trigger is realesed , but in my case it does not ,,,, stay on ..... what will you recommend .... thanks
@johnvega43378 жыл бұрын
Great information, my machine is saturating the insulation with diesel, it is smoking extremely bad, I am under the impression that the fuel is not getting burned. this video was so helpful. thank you!!!
@mike-ug9nv8 жыл бұрын
sounds like voltage issue
@Doitforyoself8 жыл бұрын
I have the same problem. Did you figure out the problem? My coils were saturated and I had to take it all out, clean it, replace the insulation and also replace tip. Yet, it still blows diesel fuel into my coils and soaks them. Right now I don't use the heat but I'm thinking I need to replace my my ignitor
@rogerbrandt66788 жыл бұрын
+Eddie Regory it almost sounds like your tip where the diesel comes out may be worn, hole to big, or dirty and your spray is going everywhere kinda sputtering.
@jritch7897 жыл бұрын
Anyone know what would cause the insulation to deteriorate on my 12v diesel burner tank?
@rongray41187 жыл бұрын
Fuel delivery issue. Check fuel delivery nozzle and output of fuel pump. One or the other is causing "over" delivery of fuel.
@steveweber53585 жыл бұрын
Great video, you forgot to mention the plastic coupling between the Burner motor and fuel pump, a broken worn slipping coupling can stop the fuel pump from running.
@Powerwash5 жыл бұрын
Thank you, that is correct
@TurboDog73TX Жыл бұрын
Massive help. Thank You VERY much.
@chrismartin73235 жыл бұрын
Wondering if you can help with something. I have the hot box from northern tool. It has a Beckett oil burner that has a turn dial thermostat and a flow switch on it. I would like to eliminate the flow switch and replace the dial thermostat with a digital one, any thoughts?
@HouseWashingRick4 жыл бұрын
Chris did you ever figure this out??. And how is it working. I'm looking for a good hot box and don't know what to buy
@TonyShilmarАй бұрын
Excellent video and information. Ver helpful. Thankyou...
@Powerwash19 күн бұрын
We are glad you liked it!
@haroldabbot776310 жыл бұрын
Great Video Been Looking For Help For Six Months , Your The Man Steve Australia
@jeffvimpeny76935 жыл бұрын
What should the temp be on a hot water pressure washer just a range? Also any guages to check temperatures
@Powerwash5 жыл бұрын
normally temps are 150 to 200 degrees Fahrenheit
@rogerl84883 жыл бұрын
Thank you for make such a great video!!! Me an my dad work on one like this all day I think now I know the problem. I think the Solenoid is bad. I wish I can find a wiring diagram because dad had them unhook an not sure if he wired back right.
@jeanpresto10625 жыл бұрын
I have a landa pgdc 4000 burner will not shut down when I let off the trigger. im sure I can figure it out but I would like your input you are knowledgeable
@franksanchez29195 жыл бұрын
Can u explaine what to do if ur fuel line to gun is not sending fuel to gun thank u
@Rokonroller7 ай бұрын
Thank you for your excellent tutorial
@daleleis55634 жыл бұрын
Do you have a video on how to adjust the igniter’s over the spray nozzle. Thank you
@Powerwash4 жыл бұрын
We do not at this time
@ridethepace60053 жыл бұрын
Look up Steven Lavimonier on KZbin. He has a plumbing service channel where he shows real time service of residential oil burners, how to clean electrodes and set them. I've learned a ton by watching him. Plus, he's from just South of Boston near Cape Cod and he's a pisser to listen to.
@benmail1282 жыл бұрын
Thank you! That was extremely helpful!
@620JK5 жыл бұрын
Am I not correct but isn’t there a 4th option as well? Isn’t there a pressure switch which tells the unit to fire once the trigger is pulled? Often times the problem is the pressure switch which gets stuck either causing the burner not to fire or fire and not be able to turn off
@israelmacotela68174 жыл бұрын
Thanks! I learned a lot of things in 10 min! Good video 👍
@Powerwash4 жыл бұрын
Glad to hear it!
@702456SIGN10 жыл бұрын
Great job, exactly what i was looking for. Powerline sold me a polished turd. my machine has operated on ONLY 5 jobs! I not only have oil spitting from the head on the right side of the motor,but the 12 volt burner stopped making heat in the middle of a my last job. I haven't done any testing yet, but i can now with your video as a reference. Thank You. (I'm thinking it might be the pressure switch)
@HouseWashingRick4 жыл бұрын
do you still have the pressure pro hot box and is it working good now
@munendrasinghtomar3795 Жыл бұрын
Continue fuel flow by nozzle. When burner turn off. What would be the problem
@BjornV782 жыл бұрын
No flame sensor (LDR / Photocell) for shutting off the fuel valve when no flame is detected ?
@Powerwash2 жыл бұрын
photocell is more common on the 12 volt systems. This is a 110 volt. Good observation
@jaimegauna5 жыл бұрын
I have a commercial pressure washer k’archer 3500 psi that won’t charge the battery. I been told it could be the starter or perhaps the coil. Do you have any suggestions,it is highly appreciated.
@KelleyMobileDetail4 жыл бұрын
What if i have a flame coming from the bottom of the burner and black smoke comes out from the bottom as well
@ktmdays2 жыл бұрын
Once in a while my becket burner on my powerwasher will rumble any idears
@Powerwash2 жыл бұрын
It likely not firing and you get a build up of fuel in the burner. Then it ignites and cause a hard burn hence the rumble
@echotoday3 жыл бұрын
Excellent video! This is the reason for you tube. Thank you very much
@OTAlucard6 жыл бұрын
What's the 4th red wire for in a 120 volt generator type setup. Does that need voltage to ignite. I'm trying to test out the machine by. Bypassing the generator. I can get the blower to spin and fuel is pumping but what does the red wire need ?
@taylorh39303 жыл бұрын
I got diesel running out the bottom of my boiler. I have a Easy Kleen pressure that is fairly new it makes small amount of smoke out the stack then I noticed I seen a bunch of diesel fuel leaking out the bottom. Any idea 🤷 ?
@Powerwash3 жыл бұрын
Oh Boy!! Your burner is not igniting. And it is dumping diesel into the chamber. When it does ignite be ready because it will shoot flame out of the burner. My recommendation is take back to your distributor so they can work on it to get it repaired. There a many things that can cause this problem.
@42064472 жыл бұрын
I just replaced my Fuel Pump on the Burner and the blower fan will not turn. It worked one day and nothing today. What would be the problem
@Powerwash2 жыл бұрын
First start by checking the power
@davidkelly440114 күн бұрын
Great job
@dpurpera5 ай бұрын
I acquired a excell model 1204 washer with a burner just like the one in this video. Can anyone identify the manufacturer so I can find a wiring diagram? I am unable to find any information on this model, Thanks
@Powerwash5 ай бұрын
give us a call we can help @ PowerWash.com
@kvlofts5 жыл бұрын
Excellent Video!! No longer a "mystery".
@darrellbelt1220 Жыл бұрын
Well say if all that works and coil ain’t magnetizing ? What gives coil the power
@billcasey4211 жыл бұрын
Thanks, very informative and helpful
@KelleyMobileDetail4 жыл бұрын
God bless you dude. This video is so much information that i need and information that makes sense.
@lostkauz833 ай бұрын
Didn’t see the part about what to check when the burner doesn’t shut off during trigger release?
@HouseWashingRick4 жыл бұрын
I just ordered my first hot box it's a Pressure Pro hot box for 4000psi 4gpm if anything breaks on it where do I go to get replacement parts for it????? infact I would like to order parts and have them on hand incase something happens on a job
@Powerwash4 жыл бұрын
Ricky, just give us a call we can get you parts for Pressure Pro 1-800-433-2113
@HouseWashingRick4 жыл бұрын
@@Powerwash ok thank you very much. ordered it from the pressure washer store in Nashville Tennessee, cant wait to get it been saving up to get it. but thank you for getting back to me
@Powerwash4 жыл бұрын
@@HouseWashingRick You are welcome. If they aren't able to meet you needs we are always here to help at PowreWash.com
@HouseWashingRick4 жыл бұрын
awesome that is great to know, looking forward to it
@forthntwint4 жыл бұрын
So if I'm not getting oil to the burner port. What are the main causes? Replaced filter, replaced pump and doing same thing. At first it was only getting hot when I turned the throttle down to turtle on my washer. Now the burner won't light at all. I'm getting air and sparc. No fuel to the burner but fuel in bleeder valve.
@chriscrouch78193 жыл бұрын
Same here. I'm getting a fuel in my return line and if I kink it off I build pressure on my gauge but still doesn't get fuel at the supply for the burner
@parton45852 Жыл бұрын
What if you have fuel spraying out of the jet whether you are on the trigger or not, My burner just started this and has completly soaked all of the insulation. The solinoid is getting power but does not recirculate the fuel back to the tank, it just constantly sprays fuel out of the jet
@Powerwash Жыл бұрын
Either the solenoid is bad or the switch turning it on and off is bad.
@yulmerced44346 жыл бұрын
i have an heated presure washer and it works for a good 10minutes minute and then shut off i by pass the temp sensor and still those the same thing i do see sparks on the transformer????
@glennmurray62192 жыл бұрын
Thank you ser
@chrisfisher91611 ай бұрын
My burner kicks on for 2 seconds then shuts off. Replaced the fuel pump and things didn't improve. When it engages you can see the fuel shut off magnetize then when it's shuts off you can see the solenoid release. Still troubleshooting but any input would be great
@ryansummers286410 ай бұрын
I’m having the same issue except mine will run about 10 seconds. If you have found out anything please let me know.
@King_Punt4 жыл бұрын
Extremely informative
@Powerwash4 жыл бұрын
Glad you think so!
@kulwindermann846 жыл бұрын
Hii my burner just blowing fire continuously.can you help me ?
@CHIBA280CRV5 жыл бұрын
Fantastic explanation sir . Thank you
@MotorFixDean9 жыл бұрын
Hi can you advise me at all please? My burner is not getting no fuel exiting the pump, it's returning back to the fuel tank ok so I k ow it's pumping it's just not switching over and going to the injector, I have changed the solenoid on he pump but still no luck. Any help would be appreciated. Dean
@mike-ug9nv8 жыл бұрын
are you getting power to the solenoid?
@jritch7897 жыл бұрын
Anyone know what would cause the insulation to deteriorate on my 12v diesel burner tank?
@Doitforyoself9 жыл бұрын
awesome video but CAN SOMEONE HELP ME?! my burner fan just budges when the switch is turned on but doesn't have any spin. The fuel pump is not sucking in fuel either. Does the fuel pump work in conjunction with the fan for it to work? It sounds like I need a new fuel pump.
@mike-ug9nv8 жыл бұрын
give it a spin with your hand after you diconect the power it may just be stuck, and yes the burner motor turns the fuel pump.
@Doitforyoself8 жыл бұрын
Thanks. I have one more question... when the burner is running I noticed there is way too much diesel fuel inside my coil system, so I replaced the tip. I then had to take out the whole coil system, clean off the diesel from the coils and reinstall with new insulation. when testing it again, the coils inside my burner is becoming saturated with diesel fuel again. Do you think that I'm not getting a spark or fire so therefore it's not burning the fuel? Any help would be greatly appreciated.
@davidcastillo2543 Жыл бұрын
So I have one that won't stay lit it will ignite but then starts blowing white smoke
@Powerwash Жыл бұрын
reduce the air intake. White smoke is an indication of too much air flow
@kensjogren28383 жыл бұрын
Great video.... Just one thing missing..... Exhaust.... If your coil is full of soot due to running rich your flame will not burn 🔥
@CBRMat6 жыл бұрын
Great video, thanks guys for some solid troubleshooting information.
@merlinmonson21334 жыл бұрын
Very well done!
@williamsalguero5074 Жыл бұрын
15 segundo y se apaga que puedo aser
@That_1_toasty2211 ай бұрын
You can trust a southern old gentleman with an engine or contraption on a cart to easily show you. 😂
@josevelasco15139 жыл бұрын
I have problem whit oil pump burner the problem is the Disel no pass
@bematthews12 жыл бұрын
Thank you for the video, very helpful !
@rogerbrandt66788 жыл бұрын
Shoot I have one of these but it's run off a gas motor, bit harder to check, but thank you very much sir, very helpful.
@jritch7897 жыл бұрын
Anyone know what would cause the insulation to deteriorate on my 12v diesel burner tank?
@thomasdavis18265 жыл бұрын
Did you figure it out ? Mine has started to turn to soot
@kt.hehner59974 жыл бұрын
My Hotzy backfires when burner is turned on. Anyone know why ? It sounds like a gun going off and black spoke comes out. It’s only 2 tears old.
@dangerousfreedom49656 жыл бұрын
Great vid👏
@bradfordsinclair59045 жыл бұрын
Thanks for the energy
@petemolina9325 жыл бұрын
Great video thanks.
@talkmack4 жыл бұрын
excellent!
@Powerwash4 жыл бұрын
Thank you! Cheers!
@808breaksbad.10 жыл бұрын
Great video. I took notes. Great explaination
@littlespressurewashing3 жыл бұрын
This is a great 👍 video #littlespressurewashingservice
@369firewolf5 жыл бұрын
On mine the fire burns, but no hot water.
@rhlpresswash12 жыл бұрын
What a great video. Thank you for making it.
@billyp12682 ай бұрын
Simple !
@shanehayward27065 жыл бұрын
HELP! fuel pump is working, fuel is coming out of bleed valve, but no fuel coming out of transfer line
@forthntwint4 жыл бұрын
Same problem. Did you figure it out?
@forthntwint4 жыл бұрын
@Seth Clemons did you figure it out?
@forthntwint4 жыл бұрын
@Seth Clemons well hell. I'm about to try that. Just got a new pump and still the same issue but it has the grey one as well. Old one had the green.
@forthntwint4 жыл бұрын
@Seth Clemons nope. Think the original solenoid is bad. Only spitting fuel and only with throttle turned all the way down
@forthntwint4 жыл бұрын
@Seth Clemons lol. I'm dont with it for now. Ordered a new solenoid. Hopefully works. Pretty frustrating stuff.
@keithstudly60712 жыл бұрын
I wish you had done the easy things first! My system had the overload breaker popped out so why do I need all the info about fuel flow and igniters before you get to telling that the pump is driven off the blower motor and can be damaged by water in the fuel? You only get to reasons your blower motor won't run after all the other systems.
@GabrielKozsar7 жыл бұрын
excelent sir ! thanks ....
@willieluttrelljr68924 жыл бұрын
Wiring forAaladin 41-530B
@WTFIsThisGuyDoing2336 жыл бұрын
This is perfect
@geoffreyfredrickson6957 жыл бұрын
No such thing as a POWER washer, it's a PRESSURE washer. 2500PSI OF PRESSURE NOT POWER!
@ricknova787 жыл бұрын
matthew thomazin yes there is. Power wash is hot water. Pressure wash is cold water.
@CBRMat6 жыл бұрын
Nice one Rick!
@The69316 жыл бұрын
matthew thomazin technically a power washer is a high pressure washer....around 40000 psi