Hi Mario, for a 3 wire diagram, please reference document 750-IN001. Page 257 shows 3-wire control wiring. Thanks: literature.rockwellautomation.com/idc/groups/literature/documents/in/750-in001_-en-p.pdf
@yenaung89933 жыл бұрын
If i want to control speed with ethernet from plc which parameter need to change sir?
@solutionconsultantsnetwork68433 жыл бұрын
@@yenaung8993 Hi Itami Z. If you want Ethernet to be the speed reference for a PowerFlex 753, then you would set parameter 545 to point to port 0: port "X" reference. Where "X" is the port containing the ethernet card. Thanks!
@shahzebali82813 жыл бұрын
Heloo sir i want to run inveter with AI input 4 to 20 mA how to configure it plz guide me thanks
@solutionconsultantsnetwork68433 жыл бұрын
Hi Shahzeb. If you are talking about the AI on the main board of the 753, then you would do the following: The video shows a 0-10V option, to switch to a 4-20 mA option, change the jumpers on the mainboard as described on page 239 of the drive manual: literature.rockwellautomation.com/idc/groups/literature/documents/in/750-in001_-en-p.pdf Next, set parameters 261 to 20 mA and 262 to 4 mA. The rest of the set-up would be as described in the video. Thanks!
@joaopaulomachado76812 жыл бұрын
Amigo qual o significado do alarme " INTERDECLARADA " ?
@juniorelectrical499 Жыл бұрын
Hello sir, i want install inverter powerflex 755 for lifting elevator, How to configure Digital output for brake system of the AC motor? Thank you