Protect Your HVAC Equipment For Less Than $80

  Рет қаралды 65,923

The DIY HVAC Guy

The DIY HVAC Guy

Күн бұрын

Ditek Surge Protector: amzn.to/3t0ywBK
America's #1 Choice For Quality, Affordable HVAC Equipment: www.alpinehome...
All my favorite HVAC tools: www.amazon.com...
IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a small fee of $200, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: @diy_hvac_guy
Tiktok: @diy.hvac.guy
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.
Jobber: The #1 operations management software for home service businesses - Free 14-day trial + Exclusive discount: go.getjobber.c...

Пікірлер: 209
@davesauerzopf6980
@davesauerzopf6980 Жыл бұрын
This is a great video. I had 2 new mini splits installed last year and the HVAC company put these in. Without fail, they did the job and saved both my units. They came back and replaced them for free! Since then I added a whole unit as well. For anyone watching this video, this is a must have.
@bnasty267
@bnasty267 Жыл бұрын
Great video. Like you mentioned at the end, I would start with a whole-house (SPD Type 2) surge protector at the main panel. It doesn't hurt to add additional SPDs at the AC disconnects or any other subpanels you have, but if you can only afford one, put it at the main panel. This is now part of the NEC (electric code). I would caution against installing multiple wires into the screw terminal like that, and it's generally not allowed. It's commonly done for these disconnects, but those terminals are only supposed to have one wire under them. It's possible that the screw won't make proper contact on the double stacked wires and it could arc and burn up the disconnect or worse. Either do a pigtail or I like the SquareD QO200TRCP disconnects with a switch that looks like a breaker (it's not actually an overcurrent protection device.) That allows 2 wires under the lug. That is rated for 60A, but it doesn't have to match the equipment, since the actual breaker is in the panel. The other nice thing about these is, you can replace the switch (with an actual breaker if you can't find the switch) if it ever burns out and not have to install a whole new disconnect box.
@TGC1775
@TGC1775 Жыл бұрын
Pin this? Thank ya for the info.
@yeroca
@yeroca Жыл бұрын
@@denverbraughler3948 That's been an ongoing issue with this channel, sadly.
@treyphipps9831
@treyphipps9831 5 ай бұрын
I installed a RSH-50 from Rectorseal on my unit, it’s got a lifetime product warranty and a LED indicator as well! Love it
@noelelnolo9642
@noelelnolo9642 Ай бұрын
There’s not a single time that I don’t learn something from you. U r awesome. I just ordered the protector and will install it this week. Thank u and please continue ur great work
@killer5846
@killer5846 2 ай бұрын
Great video! After watching one of your other videos sometime back, when I installed my three mini splits heat pumps in our home I also installed a surge protector on each unit. It gives me a little more peace of mind that if we do have a lightning strike or near lightning strike that the equipment should survive. As a matter of fact I was so impressed with how easy it was to install I'm going to have an electrician install a whole house search suppressor.
@nrmerritt
@nrmerritt Жыл бұрын
Nice video! We use a lot of ditek surge products for low voltage systems like cameras, alarms, networking and they have been reliable.
@jstasiak2262
@jstasiak2262 3 ай бұрын
I have two and possibly three issues with this video: 1. If you are going to go through the trouble of installing a surge protector on the AC unit, why not install a whole house surge protector on the main service panel instead? That way the whole house is surge protected. The installation procedure is similar except that you need to add a 30 amp double pole circuit breaker in the main panel. Whole house surge protectors are available on Amazon or at your local electrical supply store. Make sure to use one of sufficient capacity. 2. The National Electrical Code FORBIDS installing two wires on one binding post on the disconnect switch as was done in this video. This is a HARD FAIL. The proper procedure for connecting two wires to one binding post is to install a single pigtail on the binding post and then connect the two wires to the other end of the pigtail. 3. I infer that the AC condensing unit runs on 120 volts based upon the presence of a white (neutral) wire on both sides of the disconnect switch. However, most outdoor AC condensing units run on 240 volts, not 120 volts. If the AC unit does run on 240 volts, then the white wires are “hot” wires, not neutrals and must be labeled as such. If you are using Romex cable, you can do this by putting a band of red, blue, yellow, or black tape on the white wires to label them as “hot.” If you are using conduit, it is better to use a non-white, non green colored wire instead of a white wire.
@atschirner
@atschirner 3 ай бұрын
It's 240 judging by the breaker opened to remove power from the disconnect. It needs a non-whiite or green conductor.
@websurfer48
@websurfer48 2 ай бұрын
Great info - thank you. Can this be installed on a roof mounted heat pump?
@joeweatlu5169
@joeweatlu5169 Ай бұрын
@@atschirner Not a green conductor. In absence of a black or red conductor for the other hot lead in a 240 v, ckt,, the white one should be taped with black or red tape. Green is only for *_Ground_* .
@jaygunter3828
@jaygunter3828 Ай бұрын
Yeah, I was wondering if just doing a whole house protector wouldn't make more sense.
@wolfgangunger217
@wolfgangunger217 Жыл бұрын
The NEC requires Conduit Reducing washers on knockouts that leave a ring. Often these become weak with only two or three small tabs of connection there they codified this several NEC versions ago.
@jamesgor13579
@jamesgor13579 Жыл бұрын
Two conductors under a single lug is often not allowed and can result in the connection melting
@gimaru1
@gimaru1 Жыл бұрын
Interesting. So there’s no chance for them to melt when connected in a wire nut?
@concernedcitizen6326
@concernedcitizen6326 5 ай бұрын
Would be electricians. Perfect install
@AliYassinToma
@AliYassinToma 3 ай бұрын
Could be true with solid core wires.. i dont see how it would be true if one is not solid core
@stanley4006
@stanley4006 3 ай бұрын
Jamesgor13579 🙄🙄🙄🙄 Definitely not going to “melt” The termination might get hot but that’s going to take some time
@stanley4006
@stanley4006 3 ай бұрын
@@denverbraughler3948when you refer to “pressure connectors” do you mean a crimp ???? Or a wire nut ??
@krishuntzeroable
@krishuntzeroable Жыл бұрын
I pitch these all the time and tell people the importance of them, especially on mini-splits.
@iplayoldschoolrunescape
@iplayoldschoolrunescape Жыл бұрын
Youre probably like its another $300 and then theyre like hellll naaaa xD
@fanzfanzilla
@fanzfanzilla 5 ай бұрын
I never thought to install one at the outdoor condenser unit. I have had problem with my goodman Airlander ECM motor blowing out. Those are expensive to replace. I am not sure why, but I attributed it to power surge. It happened twice. It always happened during thunderstorm. The blower motor was running on 230volt circuit. To remedy this, I ran the blower off of 110 volt and used surge protector. It has survived for the past three years after the change.
@JC-gd3cc
@JC-gd3cc 11 күн бұрын
You are not supposed to combine wires under the lugs as it is a code violation and a potential fire hazzard. You need to pigtail them together below the lugs. Hope this helps and thanks for the video.
@pete7894
@pete7894 5 ай бұрын
I agree we need a surge protector, the one used in this video has a lot of bad reviews and possible fake units out there. I installed a Pioneer Mini Split System so i stuck with a Pioneer surge protector for a few dollars more and installs exact same way. For example take note of the seller rating of the supplier in the link on this video. That seller has complaints of fake units.
@Aerospace_EdC
@Aerospace_EdC Жыл бұрын
Good info, I have a bunch of surge protectors installed, besides the obvious places like TV's and computers, on my main panel, at my heat pump outdoor unit, the AHU, at my washing machine. Also as some other have mentioned, not sure about the 2 wires in one lug. For my outdoor unit I pigtailed to the lugs.
@tangoseal1
@tangoseal1 Жыл бұрын
I already beat you the punch. I installed one a week ago on my Pioneer 24k Mini Split. The Led is hyper bright and I can see it shining at night all tye way across my 30 acre property. They're about 60 bucks 9n Amazon.
@robertr1096
@robertr1096 Жыл бұрын
That's exactly the way I hooked up an old Ditek to my generator's disconnect. I did this hoping if there was a surge from the generator my circuits would be protected. My Ditek is about 20 years old though and doesn't have an led on it though. I took it off the main panel when installed a GE SurgePro.
@LordSaliss
@LordSaliss 3 ай бұрын
Surge protectors don't last 20 years though, so it is doing nothing for you.
@wholeNwon
@wholeNwon 7 ай бұрын
With lightning storms, I turn off the systems and open the breakers. The power company has installed large surge protectors on their lines throughout our area.
@cobbles62
@cobbles62 Жыл бұрын
No. This does not protect a lightning strike close by. Power surges yes. Lightning strikes a bit further away - maybe. That is valuable already. However, I would go for a whole house surge protector, especially if your breaker box is full of modern expensive afci, gfci and dual breakers.
@Imwright720
@Imwright720 Жыл бұрын
Both my inside and outside units have a surge. I also have a whole house surge on my breaker box. So far I’ve been good
@drband8181
@drband8181 Жыл бұрын
Great for surges. Probably not effective on a close lightning strike, however. It’s still worthwhile.
@timcat1004
@timcat1004 Жыл бұрын
They won't trip from a surge and do nothing to protect from that or voltage sag. They are are quick acting triac that shorts to ground causing the circuit breaker at the distribution panel to trip.
@redbaron6805
@redbaron6805 Жыл бұрын
@@timcat1004 Not sure where people are coming up with these claims. A surge protector uses a MOV, which is a variable resistor that shunts excess voltage and current to ground. It is not a TRIAC. TRIAC's are used as dimmers and speed controls for electric motors. They are not used as surge protectors, and they do not cause the breaker to trip.
@chrish7927
@chrish7927 Жыл бұрын
Ain't nothing stopping lightning. I have the Siemens FS140 and lightning hit my backyard. Destroyed various electrical things throughout the back half of my house (GFCI outlets, stereo equipment, wifi equipment, etc) and the surge protector is just sitting there lit up green still. Might help if the utility company has a surge or lightning somehow comes in through the buried electric utility lines to my panel, otherwise, break out your wallet.
@redbaron6805
@redbaron6805 Жыл бұрын
@@chrish7927 It all depends on what path the lightning strike takes. I had a TV, cable box and an amplifier damaged during a lightning strike that was running on a UPS and a surge protector. The lightning traveled through the coax line, blew up the cable box, and the cable box blew up the HDMI ports through the video link and damaged the amplifier as it was connected to the TV. So, the power outlet isn't the only path for power surges to travel.
@Merzui-kg8ds
@Merzui-kg8ds Ай бұрын
Great video. I am curious why HVAC companies fail to install a surge protector when they install the HVAC unit.
@4Lights.5Liights
@4Lights.5Liights 10 ай бұрын
Planning to install Surge Protector on the water well pump too, since R&R a submerged well pump is so expensive.
@rzh3443
@rzh3443 Жыл бұрын
The Square D disconnect the other reviewer noted does not have a side knockout ( at least the one with same ID at the local HD). One would think they would revise these to accommodate the SP devices that now are more available ? I installed an Intermatic SP on my conventional AC unit at the no -fuse disconnect after we had a lightning surge destroy the AC contactor . I did “double lug “ the load (hot out) connections withe surge leads. The neutral had a second lug. The unit has been in service for eight (8) years now with no issues. Works great and I know of at least a couple close lightning strikes that could have caused damage but did not. I suppose you could pigtail the load and SP a shunt via a wire nut but that might (?) reduce the effectiveness of the shunt ? Anyway , still here, no spark outs , shorts, etc.
@NycCitizen
@NycCitizen Жыл бұрын
These devices have a Jules rating . The higher the number…the more energy they can absorb. The best location for the device is not next to the device you are protecting…but rather the beginning of the power line at the breaker box….this is becuase the line run provides electrical characteristics that results in the majority of the surge being absorbed by the device…if you put the device next to the item you want to protect…the surge goes to both devices. The electrical componet in that black box is probally the size of a dime and probally only offers 6000 Jules clamping and real protection does not occur until you get to 30,000 Jules and if the devices uses some type of inductive windings to shunt the surge away from the device…that would require the power runs from the unit needing protection to be moved to the black box in series with the inductors and have the clamping device on the other end of the inductor. This parallel clamping de ice will have a low protection ability.
@bobbundus4593
@bobbundus4593 Жыл бұрын
joules
@albertplits186
@albertplits186 Күн бұрын
great clear video, Thx
@pavgup
@pavgup Жыл бұрын
Dielectric grease would have been helpful here.
@blackericdenice
@blackericdenice Жыл бұрын
I bet you don't have a video of you doing anything electrical.
@pavgup
@pavgup Жыл бұрын
@@blackericdenice yep, that's correct. well played.
@EarlHayward
@EarlHayward Жыл бұрын
@@blackericdenice And how does that change the validity of the comment… I don’t have a video of me working on electrical equipment, but I work for a multi-billion dollar manufacturer of electrical and cooling equipment… So, does that mean if I make a comment about the benefits of a wye-delta start, and how to program the PLCs to make that happen, would my comment not carry any weight if this was a video on commercial three phase equipment?
@blackericdenice
@blackericdenice Жыл бұрын
@@EarlHayward it depends on your comment
@brianginett4412
@brianginett4412 4 ай бұрын
Not dielectric grease but anti oxidation grease due to the aluminum and copper conductors
@theelectricianguy
@theelectricianguy Жыл бұрын
Hey Dave I am new in the HVAC trade but I’d like to see you do a video sometime on the correct way of wiring a head pressure fan speed controller for using ac during low ambient temperatures. I have a icm 325hn controller I would like to put on a unit.
@petedonna4894
@petedonna4894 Жыл бұрын
When did double tapping become ok and acceptable?
@soydelrancho
@soydelrancho Жыл бұрын
Double tapping is not allowed, regardless.
@arsenicjones9125
@arsenicjones9125 Жыл бұрын
I always double tap. I’d hate for the undead to get up on me. 😅
@frostyfroze7352
@frostyfroze7352 Жыл бұрын
The green LED is so that means it’s ok!🤣
@kenmartinez3517
@kenmartinez3517 3 ай бұрын
Not so much 100% protected here in Florida. Love your vids
@NeilsprojectFD1994
@NeilsprojectFD1994 Жыл бұрын
Another Great Video. I order 2 Ditek Surge Protectors.
@MrSongLamb
@MrSongLamb Жыл бұрын
Another great video DIY HVAC guy on surge protection system! I was wondering if you could somehow make a video about a possible solar power feature to battery bank to condenser video? Or how you would set up your dream system that would keep the home ice cold but save on electricity with complimentary systems like a whole house fan to take out hot air out of the attic and home, possible apps to monitor usage, how a house and attic should be insulated. Basically a hvac system off the grid with a ideal setup up. My electric bill was through the roof this summer and I am looking at possible solutions. Thanks for all the valuable information. I look forward to your videos like I do with this old house on the weekends. Have a great one.
@NMFF415
@NMFF415 Жыл бұрын
Thanks for the videos. Just added to my honey do list...lol...but a great investment for sure.
@jameschupp2230
@jameschupp2230 Жыл бұрын
So redundancy is good. So I do have a Surge Protector in my Breaker Box... I guess it would be good to Also have one on each unit as well.
@Kansas-Paul
@Kansas-Paul Жыл бұрын
@@denverbraughler3948 Respectfully I disagree with you. I took numerous CEU classes on surge arrestors over my 42 year electrical career and I learned the more the better and most critical is to keep the wires short as possible and no sharp bends. I installed countless suppressors in my career and have one on my load center and one on my AC.
@jroberts3428
@jroberts3428 2 ай бұрын
that's nice with stranded wire but what about solid core wire?
@AcBAYWALK
@AcBAYWALK Жыл бұрын
Wow in the country i live ill be needing one a week
@diyhvacguy
@diyhvacguy Жыл бұрын
Lol
@capnpugwash5403
@capnpugwash5403 Жыл бұрын
Feel your pain, might be the same country 🤦🏻‍♂️
@JurassicJolts
@JurassicJolts Жыл бұрын
Available from your local contractor for the now lowest price of $650
@diyhvacguy
@diyhvacguy Жыл бұрын
Lol
@TheJuls630
@TheJuls630 Жыл бұрын
Always great information. Keep doing what your doing.
@lawman5511
@lawman5511 Жыл бұрын
Easy job! We get some pretty good lightning strikes here in summer. My HVAC a company wanted $375 to install one of these. Hey, they got overhead, OK?
@diyhvacguy
@diyhvacguy Жыл бұрын
Wow, seriously??? That’s crazy
@diyhvacguy
@diyhvacguy Жыл бұрын
But it doesn’t surprise me
@lawman5511
@lawman5511 Жыл бұрын
No longer my HVAC company. Many of the “ family owned” home service companies with a good clientele have been bought by private equity companies. The techs are now salesmen. Their income is now commission. The guy that was my tech for seven years opened his own shop. My new hero.@@diyhvacguy
@mechengineer-sv2ei
@mechengineer-sv2ei Жыл бұрын
I feel like this should be installed in it's own protective enclosure or within the a/c unit electrical housing. The sun and weather will beat that thing to death. Otherwise, I like the idea.
@thomasalison6188
@thomasalison6188 Жыл бұрын
Great information; thanks for the video!
@TheRemyRomano
@TheRemyRomano Жыл бұрын
I would have installed it on the line side. I would also have used a whole house sized unit.
@diyhvacguy
@diyhvacguy Жыл бұрын
It says in the instructions to do the load side.
@sdfasdfvccvvc
@sdfasdfvccvvc 7 ай бұрын
Like others have said - this is a wrong way to install it. You are not supposed to use singe screw terminal for multiple wire connectors (unless the screw terminal is specifically designed for it, and the one in this video is not designed for it), especially with different gauge wires. Ditek themselves have an installation instruction for this model right on their website, which tells to use wire nuts to connect multiple wire ends instead of stuffing them under same screw terminals.
@Watchyn_Yarwood
@Watchyn_Yarwood Жыл бұрын
Could you please put the video links in the description that you put on screen? A lot of folks use ad blockers that do not display those on-screen links and ads. Please put the link to the whole-house surge protector in the description. Thank you.
@TerenceMohan
@TerenceMohan Ай бұрын
Is it better to install it at the compressor unit or just place one at your breaker box? That basically saves the whole house?
@JACPR1
@JACPR1 9 күн бұрын
Everything is good I need one for my aciq unit, but when I gonna buy a SP, I see the measurements in AMPS AND JOULES, I NEED KNOW EXACTLY WHICH ONE IS THE CORRECT ?
@markjohnson6224
@markjohnson6224 2 ай бұрын
Can the same principle be used with a system’s air handler unit as well? If so, any tutorial on the “how to” with adding the surge protector to the air handler unit?
@ForgetU
@ForgetU Жыл бұрын
Great video, I Need One.
@Ryan-RM
@Ryan-RM Жыл бұрын
Hi Dave, can you do a video where you install a whole house surge protector device (SPD)? Also, if someone has a whole house SPD do they still need a separate SPD on their HVAC equipment? Is it best practice to have multiple layers of surge protection or is one enough in most cases? Thank you, great video.
@bnasty267
@bnasty267 Жыл бұрын
You want as many layers as you can reasonably afford. One at the main panel, and one at any AC disconnect or other subpanels. You also want the standard surge power strips for any expensive stuff that plugs in. Modern electronics are very susceptible to power spikes (not necessarily lightning) and these SPDs are relatively cheap insurance.
@redbaron6805
@redbaron6805 Жыл бұрын
It is cheap and easy to add a surge cube to all your appliances and electronics. They can be found for around $15 or so. I always look for the one's that are UL1449 rated, as they have a 330V voltage protection, vs the cheap one's can be 400V or higher. I have a surge cube on all my appliances including refrigerator, dishwasher and washer. Anything digital with a circuit board or a display should be protected. If you have a computer or expensive TV, use a UPS also.
@davidskaggs9914
@davidskaggs9914 Жыл бұрын
Great tip!
@apokobondoni
@apokobondoni 4 ай бұрын
What if you have a whole house surge protector? No need for a surge protector for individual components then right?
@phillyfathead
@phillyfathead Жыл бұрын
Great, thank you!
@TerenceMohan
@TerenceMohan Ай бұрын
Hello, nice video! I have a question. I hear that the inverter AC’s usually break faster than non inverters, is that true? They say the main boards fry quick. I am very interested in purchasing an inverter. I figure this surge protector will help.
@josephpuchel6497
@josephpuchel6497 Жыл бұрын
Hey Thank you for the information
@lgroves336
@lgroves336 Жыл бұрын
IF you went to electronics school like me you would learn that surge protectors do NOT work against a lightning strike . The flash is so fast it laughs at the protectors as it passes through it. It does help with surge from the unit turning on.
@redbaron6805
@redbaron6805 Жыл бұрын
Then you must have flunked electronics school. Surge protectors reaction time is measured in Nanoseconds, or 1/1000000 of a second. Lightning strikes can overwhelm and damage or destroy surge protectors if they are close enough, and no equipment will survive a direct strike. But claiming surge protectors don't work against lightning strikes nearby that cause power surges is 100% false.
@keovongvilaykeo4799
@keovongvilaykeo4799 Жыл бұрын
Always great thanks 🙏 you 😊
@zunar_j5_933
@zunar_j5_933 Жыл бұрын
I've got a whole house surge protector at the main panel, but I wonder if these dedicated units being closer to the load would be more effective or would a whole house unit be fine to protect the mini splits?
@edkern0749
@edkern0749 Жыл бұрын
Great video and information. I have a cabin that I get to every couple weeks with all electric HVAC. Would you also recommend this for a well? Really don’t want to pay to have a pump pulled for shock therapy.
@dga5396
@dga5396 Жыл бұрын
Why does the line side white wire with no black or red tape on it?
@redbaron6805
@redbaron6805 Жыл бұрын
The system has Black and White wires as he is connecting it to a 120Vac system which as a Hot (Black) and a Neutral (White). If this was a 240Vac system, both wires would be Black, as 240Vac has two Hot and no Neutral wires.
@joeweatlu5169
@joeweatlu5169 Ай бұрын
@@redbaron6805 At 1:04 the breaker is double pole, so 240 v. The white conductors should be taped black or red.
@keytothegate68
@keytothegate68 11 ай бұрын
Hmm no pigtails? replace them after every power outage?
@jennyeyesxfirepioneer6934
@jennyeyesxfirepioneer6934 Жыл бұрын
Good job
@amorales9613
@amorales9613 Жыл бұрын
Love this
@Hail2MasterChief
@Hail2MasterChief Жыл бұрын
Great video.
@codegeassfan4life28
@codegeassfan4life28 Жыл бұрын
Isn't a surge protector kinda overkill? If your home is grounded properly then all discharges should be going to ground either from the utility lines, lightning strike, or internal electrical components, not to mention that's what a circuit breaker at your electrical panel is meant to do, shut off power when over amped or short occur.
@osbornab
@osbornab 10 ай бұрын
If the overvoltage or overcurrent event is occurring on L1 or L2/your hot wires, then that event will destroy the PCBs in the equipment before it makes it back to ground.
@blakebiltwell5
@blakebiltwell5 Жыл бұрын
How do u change capacitor on the slimline AC unit like the one you used on this video?
@mrautoguy8419
@mrautoguy8419 20 күн бұрын
I seen another video where a guy was installing a surge protector on the line side. You say connect it on the load side. Does it matter?
@donnellbaxter8050
@donnellbaxter8050 10 ай бұрын
Good job make more videos.
@manonfire3642
@manonfire3642 Жыл бұрын
Protector wires appear to be aluminum. Can't connect aluminum with copper without proper lubrication. Is the wiring of the protector indeed aluminum?
@jimmaag4274
@jimmaag4274 Жыл бұрын
Please, step slowly away from the electricity.
@manonfire3642
@manonfire3642 Жыл бұрын
@@jimmaag4274 electrolysis is no joke. Better response needed.
@nomen_meus
@nomen_meus Жыл бұрын
There is nothing in the Ditek literature that identifies wire type, but I would assume the wires are tinned copper rather than aluminum.
@jimmaag4274
@jimmaag4274 Жыл бұрын
@@nomen_meus that wouldn't occur to an apprentice trying to show off on youtube.
@LordSaliss
@LordSaliss 3 ай бұрын
If your main electrical panel has the (now required) whole home surge protection, is it still recommended for AC disconnects to have their own local to the outdoor unit itself?
@mauroaparicio1855
@mauroaparicio1855 Жыл бұрын
good item
@JamesWard-ne3do
@JamesWard-ne3do 5 ай бұрын
The Green LED, over his left shoulder, went out as he was finishing his presentation at about the 7:24 point in the video timeline. What does that mean? Otherwise a good presentation.
@diyhvacguy
@diyhvacguy 5 ай бұрын
It was my camera. Sometimes it didn’t want to pick up the green led for some reason.
@timcat1004
@timcat1004 Жыл бұрын
Why are you using a black and white for L1 and L2 240 VAC? You should have labeled the white as red L2.
@jimmaag4274
@jimmaag4274 Жыл бұрын
Umm, that's not how it works
@redbaron6805
@redbaron6805 Жыл бұрын
He is using Black and White as this is a 120Vac system, and he is using one Hot and one Neutral wire.
@timcat1004
@timcat1004 Жыл бұрын
@@redbaron6805 He is not. That is a 240 volt unit. Try again.
@redbaron6805
@redbaron6805 Жыл бұрын
@@timcat1004 My bad. Double checked the video and it is indeed a 240Vac system. You are correct that the White wire should be labeled as Hot when used in 240V application as it normally indicates a Neutral if it is not marked as Hot.
@richardefriend
@richardefriend Жыл бұрын
Is there any objective 3rd party testing of this device. I'm not an electrical engineer, but a parallel 'surge protector' still allows lots of unwanted power travel over the other lines. I'm having trouble seeing how it can do much good for a lightening strike (and I've seen first hand what they can do--twice), or is this only for small power line surges?
@edbouhl3100
@edbouhl3100 10 ай бұрын
That’s why I always use ‘listed’ equipment from an approved test lab such as UL and tested to an official standard. You still have to make sure that standard applies to what you want to do. This particular product does have the UL mark.
@mamumonkan
@mamumonkan Ай бұрын
Hello there, we have problems with Voltage fluctuations, where the voltage dips briefly and then comes back on right away. This causes my AC compressor many problems, so I installed a ICM Delay on Make Timer. The strange thing is that the timer does not cut out at those dips but only delays once the electricity goes off completely ( same counts for the built in delay in my Air handler thermostat. So here my question : Is this Ditek Surge Protector a solution or do I need to install something else ? Thank you so much !
@ahmadeshish5878
@ahmadeshish5878 Жыл бұрын
Why we change the whole condenser instead of the compressor and dryer when it’s go bad?
@gimaru1
@gimaru1 Жыл бұрын
How does it compare to the Intermatic AG3000? Nice job, and thanks for posting!
@diyhvacguy
@diyhvacguy Жыл бұрын
Not sure I’ll have to check that one out
@waynenocton
@waynenocton Жыл бұрын
There’s got to be good way to capture all that heat the outside unit is putting off, and put it into hot water for the house, or pool, or spa.
@Tom-sg4iv
@Tom-sg4iv Жыл бұрын
I thought my heat pump would do that, use the heat from A/C to do the DHW, but that was not the case ☹️
@AustinMichael
@AustinMichael Жыл бұрын
It's called a heat pump water heater.
@waynenocton
@waynenocton Жыл бұрын
@@AustinMichael I have a heat pump water heater, it has nothing to do with the hot air output of my HVAC unit.
@edkight6447
@edkight6447 6 ай бұрын
I ordered and installed from your link on on my 12K mini split, but got no LED ? . The tech support is saying disconnect one leg to try to light LED. Have you seen this issue on 120 V unit ? Thanks
@luisrego2838
@luisrego2838 5 ай бұрын
Is the soft start you recommended in other videos a surge protector aswell?
@websurfer48
@websurfer48 2 ай бұрын
Can this be installed on a roof mounted heat pump?
@thekehoeshow..
@thekehoeshow.. Жыл бұрын
If this is wired in parallel, how does it provide any protection al all? A surge protector needs to be in series before a device so it can be sacrificed to save the downstream device.
@bnasty267
@bnasty267 Жыл бұрын
The way these work is by using components called MOVs, which are basically voltage-based switches that only conduct current when the voltage goes above a set amount. The MOVs are connected between the hot leads and ground, and at normal voltage, they aren't passing any current. However, if the voltage spikes above the set amount (usually like 150V), the MOV 'turns on' and dumps that current to ground, often killing itself in the process. Usually, these voltage spikes are transient and fast, so the circuit breaker won't even trip and the MOV might not completely die.
@diyhvacguy
@diyhvacguy Жыл бұрын
Wow excellent explanation sir. 🤘🏼
@fritter6546
@fritter6546 Жыл бұрын
@@bnasty267 I get it now - normal voltage always goes to the equipment and any excess is rerouted. Neat set up. Curious what happens on a large or extended surge after the MOV dies. If it is no longer able to actively dump the excess to the ground, won't all that voltage just be conducted to the end equipment at that point? Or is that a situation where you'll have bigger problems than your A/C unit getting fried?
@bnasty267
@bnasty267 Жыл бұрын
@@fritter6546 High end surge protectors often have multiple MOVs (sometimes half a dozen or more) wired in parallel to serve as backup and to handle larger surges. Similar to the unit shown here, usually there is a little thermal fuse essentially stuck on the MOV that turns off a little green LED when the MOV heated up from a big surge, and thus sacrificed itself. When the light goes out, that means it's time to replace the SPD, because it no longer offers any protection. You're right though, they can only do so much. A huge surge like a direct lightning strike is going to blow right through it.
@Vic92
@Vic92 4 ай бұрын
Surge protectors are supposed to be installed in the line not in the load.
@joeweatlu5169
@joeweatlu5169 Ай бұрын
The instructions for this one indicate that it goes on the load side. The brand I install indicates line side.
@tobywilliams4614
@tobywilliams4614 Жыл бұрын
Does it actually work? It seems like it would just blow it right along with the a/c unit. Its like just piggy backing another appliance to a circuit. I could understand if it was inline.
@Nilocsemliw
@Nilocsemliw 6 ай бұрын
Im currently looking at the ACIQ mini splits. How have you liked your system? Is exteme heat worth it? The coldest temps I see are only -5F. I do not have a ducted system to supplement heating.
@kyleglover2353
@kyleglover2353 3 ай бұрын
Why do some wire it up to the line side and some wire it up to load side? This is driving me crazy seeing so many videos doing it differently
@joeweatlu5169
@joeweatlu5169 Ай бұрын
The instructions for this unit indicate load side. My unit indicates line side.
@peckerpeter2078
@peckerpeter2078 Жыл бұрын
Since the invention of duplex receptacles😂… But those are the same gauge wire and made for it. And theses are clearly not along with being totally different gauge wires.
@mikeoxlong5843
@mikeoxlong5843 6 ай бұрын
Surge protectors ARE NOT 100 %. I had a "whole house" surge protector installed. Last week we had a power surge and it blew up my furnace and three retail surge protector power bars. I had to replace the entire furnace circuit board. Surge protectors are better than nothing i suppose, but they're also a false sense of security.
@yankeesusa1
@yankeesusa1 Жыл бұрын
How do i find out which one will be sufficient for my ac unit?
@Thomas-wn7cl
@Thomas-wn7cl Жыл бұрын
Does this product protect against under voltage?
@benkanobe7500
@benkanobe7500 Жыл бұрын
And because it is AC (current) there is no "polarity" and that is why either one of the surge protector wires can go to either one of the load wires? (I'm sincerely asking).
@diyhvacguy
@diyhvacguy Жыл бұрын
Correct
@indexglow
@indexglow Жыл бұрын
Great idea……i have a question though. I have 2 disconnects on my heat pump package unit. Which one would need the surge protector?
@tangoseal1
@tangoseal1 Жыл бұрын
Both - the whole house is one big shared circuit and thus you need to protect the surge from coming Into tye AC on all legs that lightning etc.. can ingress.
@diyhvacguy
@diyhvacguy Жыл бұрын
One is for your heat strip and the other is for your compressor and fans. The one for your compressor and fans is the one you want. It’s probably a smaller breaker then your heat strip 👍🏼
@davem3789
@davem3789 Жыл бұрын
7:09 Amazon description says country of origin is china. Great idea. I need to find one not made by the ccp for my mini split.
@redbaron6805
@redbaron6805 Жыл бұрын
Amazon description is obviously wrong, as the unit is clearly says it is Made in the USA.
@davem3789
@davem3789 Жыл бұрын
@@redbaron6805 I got this from Ditek this morning - " the product is manufactured in Largo, FL USA using a mix of US and globally sourced components" I do give them credit for a quick and what appears to be an honest reply.
@cheekybastard99
@cheekybastard99 12 күн бұрын
Why china makes the best quality at this point.
@joeweatlu5169
@joeweatlu5169 Ай бұрын
Those lugs aren't rated for two conductors.
@PeterPhan8888
@PeterPhan8888 Жыл бұрын
Can i apply this to my central air to protect my capacitor ? thanks,Peter
@diyhvacguy
@diyhvacguy Жыл бұрын
It’s more for your circuit board, and other sensitive electronics. Not sure if it would help with a capacitor but it very well might!
@PeterPhan8888
@PeterPhan8888 Жыл бұрын
@@diyhvacguy Thank you. Let me know when you are around Boston.
@19BADGER-F250
@19BADGER-F250 Жыл бұрын
Would you install this the same way if my a/c is right next to my main and I don't have a a/c disconnect? Mine is set uo to just flip the breaker.
@rhymereason3449
@rhymereason3449 Жыл бұрын
How does something wired in parallel protect the equipment?
@joeweatlu5169
@joeweatlu5169 Ай бұрын
It absorbs the excess surge. I installed a similar unit, different brand, installs the same way.
@ronaldnaeyaert3653
@ronaldnaeyaert3653 Жыл бұрын
I just installed a Siemens FSP140 Pro whole house surge suppressor in the main panel. My Carrier Infinity Series AC compressor is on a seperate meter and the wiring appears to be seperate from the main panel and is not most likely not protected by the FSP140. Can this device be installed and will it protect ths seperate circuit?
@HoodHandyman
@HoodHandyman Жыл бұрын
what if your not using a disconnect and your using 120v with one breaker ? Then all you have is 1 ground 1 common and 1 load/line wire
@tangoseal1
@tangoseal1 Жыл бұрын
It works with 120v as well and you can install it on your breaker circuit in your main panel that is for the AC
@HoodHandyman
@HoodHandyman Жыл бұрын
@@tangoseal1 thanks
@lambition
@lambition Жыл бұрын
Are you sure it is ok to have that surge protector outside? I don't think that is waterproof.
@nomen_meus
@nomen_meus Жыл бұрын
It is labelled as a NEMA 4X enclosure, so it is well protected against dirt and water ingress.
@tigerz4487
@tigerz4487 Жыл бұрын
so this can be used as a lightning rod ,right、?
@ldenorio
@ldenorio Жыл бұрын
so, should you buy 2, keep 1 as a back up?
@diyhvacguy
@diyhvacguy Жыл бұрын
Not a bad idea
Did You Know You Can Replace Your Own Air Conditioner?   -SAVE THOUSANDS-
23:51
This mother's baby is too unreliable.
00:13
FUNNY XIAOTING 666
Рет қаралды 25 МЛН
STOP Buying This HVAC Brand
9:38
The DIY HVAC Guy
Рет қаралды 612 М.
Keep Your Family Warm During A Power Outage By Installing This $5 Part
11:47
The DIY HVAC Guy
Рет қаралды 1,7 МЛН
AC Maintenance - How to Install a Surge Protector For Your Air Conditioner
6:53
Any Hour Services - Electric, Plumbing, Heating & Air
Рет қаралды 41 М.
DIY Mini Split Install - All the Things Nobody Shows You
33:25
LRN2DIY
Рет қаралды 2,1 МЛН
A $600 Ductless 110v Mini Split?!
32:38
The DIY HVAC Guy
Рет қаралды 593 М.
4 Air Conditioner SECRETS That HVAC Companies Don't Want You To Know About
12:20
Too Many Homeowners Fall For This HVAC Scam
6:03
The DIY HVAC Guy
Рет қаралды 571 М.
How To Clean A Ductless Mini Split Air Conditioner / Mr Cool
15:44