No video

Pulmonary Artery (Swan Ganz) Catheter

  Рет қаралды 309,265

PainH8er

PainH8er

Күн бұрын

Пікірлер: 51
@jonnbruin
@jonnbruin 11 жыл бұрын
I'm about to start training as an anesthesia tech and all your videos have been so helpful in helping me prepare. just wanted to say thanks for taking the time to do all this, it's much appreciated!
@CoreyEmills
@CoreyEmills 11 ай бұрын
Are you still a Anesthesia tech or did you switch it up
@angelakim1260
@angelakim1260 9 жыл бұрын
I agree with previous comments. Very easy to understand!!!
@krizziafrias
@krizziafrias 4 жыл бұрын
I’m new to the CT-ICU unit in our hospital and your videos are helping me a lot. Thank you!
@moila04
@moila04 5 жыл бұрын
Thank you so much for this video. I love how you clearly explained it.
@jjlatinopedia
@jjlatinopedia 5 жыл бұрын
I accidentally put medication in the balloon port
@IronReef77
@IronReef77 7 жыл бұрын
Thanks for the video. Im going into the ICU soon from ER so I wanna be on top of everything ahead of time
@kpulkit5627
@kpulkit5627 2 жыл бұрын
Crystal clear explanation , thanks !
@BC-xm6pm
@BC-xm6pm 2 жыл бұрын
Thank you so much! Made it so much clearer for me. Going to my ICU clinical tomorrow
@ventilator98
@ventilator98 11 жыл бұрын
THIS IS SOOOOOOO AWESOME. I love the PA catheter. Please do more videos. PLEASE.
@dsm2nrs
@dsm2nrs 3 жыл бұрын
Concise and clear with demonstration, thank you!
@suzannetriana4949
@suzannetriana4949 6 жыл бұрын
great video to get details quickly!!!
@danyjamal6471
@danyjamal6471 Жыл бұрын
To increase the likelihood of leading the catheter to the PA : 1. Should we Feed the PA catheter through the cordis rapidly or slowly? 2. Should we put the patient upright or supine ?
@PainH8er
@PainH8er Жыл бұрын
1. Slowly 2. We always start supine
@misstinaaa
@misstinaaa 6 жыл бұрын
thank you so much! such excellent and clear explanation!!!!
@shakthi_raman
@shakthi_raman 2 жыл бұрын
Awesome and succinct video! Thank you for making this :)
@prettygirl1024
@prettygirl1024 7 жыл бұрын
great video
@sarahnguyen1646
@sarahnguyen1646 3 жыл бұрын
Great video !
@jeangray6863
@jeangray6863 Жыл бұрын
Thank you, thank you very detail
@damanpreetkaur1969
@damanpreetkaur1969 4 жыл бұрын
Amazing explaination !!
@ValentinanSantinamommy
@ValentinanSantinamommy 6 жыл бұрын
Awesome thank you
@stephaniebiley420
@stephaniebiley420 10 жыл бұрын
Oh man all I can say is THANK YOU!!!! Very easy to understand! I have one question. Does the catheter itself ALWAYS sit in the PA? and Do you need to back it out to get pressure readings and waveforms for the RA and RV?
@lancecarter2842
@lancecarter2842 10 жыл бұрын
Thanks for the compliment! Yes, the distal tip of the catheter always sits in the PA. Remember that hooking a transducer up to the yellow port will give you a pulmonary artery pressure. Clinically, we never need to get a right ventricular pressure. But right atrial pressure and CVP are considered to be roughly equal. In order to know CVP with a Swan, you don't back the catheter up. Rather, there is a port at roughly the 30cm mark of the Swan. This should sit in the right atrium. If you hook a transducer up to this port (blue port), it will tell you the pressure in the RA (CVP). Any other questions? Let me know!
@drhorton100
@drhorton100 3 жыл бұрын
Thank u
@ankuraryan8951
@ankuraryan8951 9 ай бұрын
Good
@sayedjubran8954
@sayedjubran8954 8 жыл бұрын
As you are always wonderful.
@osce1862
@osce1862 8 жыл бұрын
thanks great video
@thanhpham-jo9pq
@thanhpham-jo9pq 2 жыл бұрын
Some segments in the video are stamped not adjacent to each other
@yellowcolorado25
@yellowcolorado25 5 жыл бұрын
Can the PCWP be obtained if the PA port was obstructed or not plugged into the machine? I just had an examination that provided a diagram of a PA catheter. It asked what port obtained the PCWP... Answers were as follows: A) CVP port, B) Thermistor port with the red cap, C) PA port, D) the balloon port. I chose C and was told it was wrong. The instructor said it was the balloon port, which is used in the process of getting the PCWP, but it doesn't obtain the PCWP pressure.
@PainH8er
@PainH8er 5 жыл бұрын
That is a horrible question. If that is how the question was worded, the correct answer is the PA port. Prior to wedging, the PA port is sensing blood pressure from the forward moving flow from the pulmonary artery and right side of the heart. Once the catheter is wedged, the PA port can no longer sense blood pressure from the right side of the heart. It can only sense pressure coming from the pulmonary veins and left side of the heart. The balloon allows wedge pressure to be possible, but the port that provides the pressure is still the PA port. Does that make sense?
@yellowcolorado25
@yellowcolorado25 5 жыл бұрын
Pain, I totally understood that and that is why I picked C. I appealed the question and the instructors are watching each other backs and not giving the points back. Thank you for the explanation though.
@classiccrystal5476
@classiccrystal5476 4 жыл бұрын
Why would the Dr change the number on the machine and us a calculator to come up with number . I thought this precedure would give us the number
@jojohnson32
@jojohnson32 2 жыл бұрын
I have a question about the cordis with a distal brown port & a white port? The brown port of cordis seems large so therefore can you measure CVP via that port?
@PainH8er
@PainH8er 2 жыл бұрын
I haven't seen a Cordis with a distal brown port. I'm not saying they don't exist; I just haven't seen one yet. Sorry I can't answer your question!
@jojohnson32
@jojohnson32 2 жыл бұрын
@@PainH8er I’m sorry I should have been more detailed… I am referring to the MAC double lumen catheter. Some of my coworkers challenged the fact that the brown distal port may be in accurate due to the diameter
@PainH8er
@PainH8er 11 жыл бұрын
Awwweee, thanks!
@soccerstarcjh
@soccerstarcjh 7 жыл бұрын
Contamination shield? I just call it the swandom. Don't be a fool and wrap that tool! xD
@mchrist4313
@mchrist4313 6 жыл бұрын
Guest Console ur funny haha
@courtneyhowe8832
@courtneyhowe8832 2 жыл бұрын
My preceptor calls the shield a “swandom”
@shraddhakanna
@shraddhakanna 7 жыл бұрын
aren't there 5 ports? is the fifth one the thermistor port?
@PainH8er
@PainH8er 7 жыл бұрын
You are right! I should have talked about that, but we just never use it. :/
@shraddhakanna
@shraddhakanna 7 жыл бұрын
PainH8er thanks a ton.. this helped a lot. :)
@lmathew09
@lmathew09 8 жыл бұрын
I have a question, does the baloon at the tip of the catheter remain inflated all the time or only during pressure checks. ?
@PainH8er
@PainH8er 8 жыл бұрын
+linu mathew Thanks for the question! The balloon should definitely only be inflated when the catheter is being advanced. It would need to be inflated if the anesthetist wanted to know what the patient's wedge pressure is.
@mchrist4313
@mchrist4313 6 жыл бұрын
Thanks it was very clear to understand.
@yasminezlitni9909
@yasminezlitni9909 3 жыл бұрын
❤❤❤
@humzaifat1
@humzaifat1 5 жыл бұрын
Thanks a lot for the awesome explanation. But can anybody tell me, how many lumen are there in this catheter ? Since there are 5 ports, so one should be for each, but diagrams of cross section of the catheter on the internet shows only 4 lumen ?. Last one which you did not discuss is the thermistor port or transducer port or are they same thing ? Thank you
@PainH8er
@PainH8er 5 жыл бұрын
Yes, I didn't mention the thermistor port. Mostly because we never use it in anesthesia. Thanks for pointing that out :)
@humzaifat1
@humzaifat1 5 жыл бұрын
How many lumen are there in this catheter ? Thank you
@lancecarter2842
@lancecarter2842 5 жыл бұрын
4 ports. 3 transducer ports plus one balloon port. Some Swans also have a thermistor.
Initial Steps to Central Line Insertion
4:00
PainH8er
Рет қаралды 742 М.
Pulmonary Artery (PA) Catheter Waveforms EXPLAINED!
15:31
ICU Advantage
Рет қаралды 72 М.
الذرة أنقذت حياتي🌽😱
00:27
Cool Tool SHORTS Arabic
Рет қаралды 24 МЛН
Идеально повторил? Хотите вторую часть?
00:13
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 18 МЛН
Meet the one boy from the Ronaldo edit in India
00:30
Younes Zarou
Рет қаралды 18 МЛН
Pulmonary Artery (Swan Ganz) Catheter Insertion
5:58
PainH8er
Рет қаралды 285 М.
Swan Ganz Numbers: presented by Dr. Gallagher's Neighborhood
9:04
Dr. Gallagher's Neighborhood
Рет қаралды 411 М.
Swan-Ganz module setup and navigation on HemoSphere advanced monitor
22:21
Edwards Lifesciences Clinical Education
Рет қаралды 23 М.
Central Line Catheters
3:48
PainH8er
Рет қаралды 76 М.
Setting Up a Pulmonary Artery Catheter | Mosaic Life Care
24:04
Mosaic Life Care
Рет қаралды 21 М.
Peripheral Venous Catheter Placement
8:44
Clarius Mobile Health
Рет қаралды 35 М.
Hemodynamic Monitoring Part 1
14:05
Christina Heard
Рет қаралды 307 М.
Swan 3
10:53
Instituto de Cardiología - Hospital Universitario Austral
Рет қаралды 46 М.
Right Heart Catheterization  - an introduction
20:09
Rob Attaran
Рет қаралды 30 М.
Central Venous Pressure (CVP) Monitoring and Measurement Basics
13:58
Whiteboard Medicine
Рет қаралды 1,2 М.
الذرة أنقذت حياتي🌽😱
00:27
Cool Tool SHORTS Arabic
Рет қаралды 24 МЛН