One thing you should do especially when using propane to power a generator is to purge the lines by hooking up the hose to the tank and then opening the valve briefly until you smell gas and then connect it to the generator. What is happening here is the propane line has air in it and it is slowly filling with propane as you pull the cord and is taking it's sweet time getting to the spark plug. I use a similar trick when lighting my propane heating stoves for the first time of the season. Using a BBQ lighter I heat the thermocouple until the gas valve stays down then open the main gas control while still having the BBQ flame on the thermocouple and in seconds the main burner will light.
@sfomanssp13347 ай бұрын
The look on your face when you said "some say the choke only apples to gas". Then you switch to RUN and it starts. Priceless
@privateuser-xp4nz Жыл бұрын
Just a bit of info when the choke was on the pressure regulator saw no draw and would not allow propane to flow. On gasoline engine you're trying to draw gasoline from the tank to the bowl to the needle to the engine on propane you must leave it in the "run" position or the pressure regulator will not open up
@MR_Garage Жыл бұрын
Good video! I did a general overview on this one as well and it ended up replacing my predator 3500. You made a smart choice. Super lightweight and powerful. On the hard start on propane, super easy fix. Hook up your propane line to the tank and generator. Turn the propane tank on. Then, back off the connection on the generator and you will hear propane leaking / hissing. Do this for about 6-8 seconds to purge air and then tighten the connection. After this, will always fire cold in 1-3 pulls (1st pull for me on most occasions). Cold starting on propane with air in the lines was so bad, I almost returned it. Glad I did not! Gave you a like and subscribed. Keep up the good work. 👍
@ricbryandado6933 Жыл бұрын
Good video. The trick is 1 pull on the choke and 1 pull on run. Hope that helps.
@NoNoBracket5 ай бұрын
Great video. I experienced the exact same thing. Was about to return it but then tried it in Run and it started right up.
@ymhymh3944 Жыл бұрын
Thanks for taking the time to make the video. More information out there for everyone.
@MrSkunks Жыл бұрын
Ended up buying this generator for home backup. Connects directly into my panel with an interlock. Also got a 1/4 propane hose with quick disconnects attached to my home propane supply. Plan to never run gas through it. For the quick disconnects, I have a spare male attached to the generator with a string. I attach it, run propane until it starts out of the hose and then plug it into the generator. Starts first or second pull. With the hose you have, before connecting it, turn the propane on and let it run for a second, turn it off then plug it in.
@coreykretsinger Жыл бұрын
I purchased one of these and the carb was bad right out of the box. Be very sure to test this as soon as you get it. It's been a nightmare trying to get a working unit and I've finally given up. Returning today.
@ruckusmayhem9531 Жыл бұрын
Thank you for the video, it helped me out a lot!! Look forward to your video of you testing of this product.
@californiaman888511 ай бұрын
Just got Ryobi 2300 used one and very like it, it got front display and bluetooth, wheels and use gas only.
@MrSkunks Жыл бұрын
Would love to see more videos, tests on this generator
@bobharrington3373 Жыл бұрын
Dude I bought this same generator and pulled and pulled and pulled until I turned the choke off. Then it fired right up! I was wondering how long it was going to take you to turn the choke off! I bought this for my new camper. It runs the ac, microwave, tv and all the lights running off of propane. I am pretty impressed with it so far!
@Kemstylebossy Жыл бұрын
Does yours ever start on choke?
@bobharrington3373 Жыл бұрын
@Kemstylebossy it did the other day. I haven't ever needed to use the choke though. I tried it just to see if it would.
@Kemstylebossy Жыл бұрын
I’ve come to learn that the switch writng is slightly off so if you don’t turn it to the exact mark it will start on choke turn and you’ll feel when it clicks
@bobharrington3373 Жыл бұрын
@@Kemstylebossy thanks! Good to know!
@mckenna86w8 ай бұрын
How long does a 20lb tank last when using with your camper?
@herbbot82415 ай бұрын
Haha switched to run worked! Thanks buddy I just bought one and will count how many times pulled on run
@herbbot82414 ай бұрын
I set it up today took 5 pulls on run using propane
@357sps5 ай бұрын
You need to prime the gas line before trying to start the generator, once the air is out propane will flow and start on the first crank. Loosen up the hose a bit and once you smell gas re-tighten the hose and it will start easily.
@Forged721 Жыл бұрын
Whole lot of power for a sleek little suitcase unit , sweet !!!! Surely there just making better n better inverters ,
@elvisortegaortega3860 Жыл бұрын
Good video amigo I'm looking to buy one thanks for the great information
@dragonslayer7587 Жыл бұрын
Thanks so much for doing this Video! I would have pulling my arm off trying to start it! I've got an old dog house we don't use, and plan on keeping my new Generator in there! That way, I can use it, but not hear it, and after last year during hurricane IAN, we had MANY people stealing Generators, so it's going to be easier for me to prevent this using the dog house. I've got an older gasoline only, 6500 Subaru, and I've got a feeling it's not going to make it thru another week of heavy use, like last summer. I like the idea of propane in Florida as well. Anyway, think about building it a small shed to keep it in and you won't hear the noise. As long as the ventilation is good, it will keep the unit safe, cleaner and again cut noise.
@darthraider2483 Жыл бұрын
Just bought this for an rv to run specifically on propane hope its a good one.
@ksladds11 ай бұрын
Is that Ronda its like you are at the Chinese Buffet and there is no duck sauce am I right?
@cpfpv6410 Жыл бұрын
Long video but thank your for making it!! I am very interested in this generator. Please do more testing with it. Maybe use an outlet tester on it to make sure its wired correctly to the outlets and that sort of thing?
@carlosmadrigal6491Ай бұрын
November 18 2024 Thank you, this video really helps me.
@greggriep2883Ай бұрын
Thank you pulled on the cord tell i was out of breath took it off chock first pull it started.
@ClaytonDeeringC3D Жыл бұрын
Good informative video. “Trip the kids.” haha 😂 that absolutely happens.
@montywm699 ай бұрын
What is the run time off a tank of propane?
@tristanschaper28111 ай бұрын
Does your spark plug wire socket have a rubber boot around it that pushes firmly into the surround hole around the spark plug? Mine only has an upper rubber “cap” that covers the top of the hole, but no rubber around the plastic wire connector. So it vibrates. I think it’s missing on my unit. I have other brand units that have the rubber that makes a firm seal around that hole and keeps it secure. Any chance you can add some photos of yours?
@GOLTURBO55511 ай бұрын
1st purge the propane from the hose... 2nd 2 pull with choke... 3rd switch to run and ll at the 1st pull. 4th no synthetic in the first run. Use mineral and change the oil after 1 hour at low idle. Done.
@onenation7784 Жыл бұрын
How long did it run with the 20lb tank
@odgerelkhunnu8398 Жыл бұрын
It is so loud even the super-quiet tag is on it 😁😛
@thatbikerdude1378 Жыл бұрын
Excellent review! Thanks!
@JimVincitore Жыл бұрын
Great video! Very cool! THANK YOU!
@infunerous666 Жыл бұрын
The choke is actually a prime when on propane
@joejohnson2478 Жыл бұрын
How is that generator holding up? I'm considering getting the same one that you unbound. I wanted a dual fuel generator which was light and powerful. Please let me know.
@6toeNL7 ай бұрын
Take a close look at the colors of the symbols on the dial. Green=start on propane, blue=start on gas
@keilergranado92309 ай бұрын
I have a question, I have the same generator and when I have it on for a while and I turn it off, when it comes to turning it back on I have to wait a long time for it to even start up. What would it be?
@Soli_Deo_Gloria_.11 ай бұрын
Purge the air from the line 👍
@MarkSDCA Жыл бұрын
What kinda of gas (lpg) did you get? I am looking to buy a 5 or 10lb tank and could use some input. Thanks for the great vid.
@Greatlakesprepper Жыл бұрын
I just get prefilled 20lb tanks from lowes. But they only fill it with 16lb/4gal..tractor supply and other farm stores sell various sizes from 10lb up to 100lb
@MarkSDCA Жыл бұрын
@@Greatlakesprepper Sorry. I wasn't very clear. I was looking for runtime on a bottle of propane so I could decide on what size bottle to buy. But I just bought a 10lb tank. Also, has anyone tried to change the oil in these yet? Looks like the only way is to fill the interior of the case and let it drip out the bottom via a small hole in the bottom of the case. Not a very user friendly design.
@lukeb03194 ай бұрын
You need to purge the line first and it will start right up and don't use the choke. That is only for gasoline.
@giulianoargentin7656 Жыл бұрын
Great video, just wondering about oil. You said you were going to use synthetic oil but used supplied oil. I read that never use synthetic oil in generators, is this true?
@scubajeeper1 Жыл бұрын
Use petroleum base oil for break in, after that you can switch
@concreteart1015 ай бұрын
I've got one coming... have a Honda now
@Asidebar2 ай бұрын
You have to have it set to run to run!
@busterhyman6633 Жыл бұрын
Must be from the South. I turned the choke off and it started on the 2nd Pull LOL. I just ordered my 2nd one of these and will run them in parallel. Should run 3 Frigs and 2 freezers and the heater blowers that pull 1169W and 869W respectively. These little suitcase units are hard to beat for the price and I like to have a couple little gas sippers to back up my Generac. I do recommend the WEN 55201 Magnetic Oil Dipstick for Inverter Generators it fits perfectly and I use it on my pulsar 2200.
@californiahikingadventures22497 ай бұрын
lol, I was just going to write the choke is not for propane and you yanked it once on run 🤣
@darthraider2483 Жыл бұрын
Update just tried to use it on my rv with 13500 btu ac and on propane it will not run. 2nd update unfortunately i do not have soft start on my ac so i ran my built in generator for 30 min to allow ac compressors to warm up the. Switched to the generator and it ran the ac with no problem
@gregoldham4424 Жыл бұрын
I was wondering would it start you 13500 ac on gasoline?
@darthraider2483 Жыл бұрын
I assume it will but I'm only gonna be using it with propane as of now.
@foxhunt1783 Жыл бұрын
I have a 15K BTU Coleman and it started up with installed start up capacitor from factory. Its a 88-108 MFD capacitor connected with a start up resistor that takes it off line as soon as it starts up. They sell those for about $40 or so on line or you can build it yourself by ordering capacitor and start up resistor separately. Best is if you find out from your AC maker what they recommend for start up capacitor so you dont ruin the start up coil over time with too much capacitance energy. Mine starts up with no trouble and cycles in and out with fan. I monitor volts and hz and they are right on the money at start up. In the camper I get down to about 118 Volts at start up and then recovers back to 120 volts. Hz stays right at 59-60. The voltage reading right at generator is 122 Volt with minimal load. With AC its at around 119-120 at start up. Doesnt dip that much because the unit kicks in quickly with start up. Voltage stays steady. Now if I turn microwave on, then it dips some more and starts to overload some. Makes alot of noise to keep the rpms up. I would not recommend that for too long. My converter is on while all this is going on so I'm sure I do exceed the 24 amps with propane. I have not run it on gasoline yet bcus I do not intend to. I'm sure I could get more power out of it if I did but my intention is to run propane only. I have diesel in my truck and propane in my camper, I dont need to lug around another fuel type.
@trumpdanusan11 ай бұрын
did you leave off eco first before plugging in and it starts lol
@paultice610 Жыл бұрын
I bought mine and refused the warranty and they still sold it to me predator 3500 2 years ago
@calvinlong1265 Жыл бұрын
I'm thinking about getting one of these, and am just wondering if you are still happy with this unit.
@Greatlakesprepper Жыл бұрын
I haven't used it that much yet. But the reasons I got it were dual fuel capability,high wattage/dollar ratio,high wattage/size ratio,light enough to pickup...the downsides were only 1 120v outlet,small 1gal gas tank and slightly louder noise then some others.
@GNARLOUSE4 ай бұрын
Thanks
@amelsfr Жыл бұрын
it's a very good product, but there's 2 downsides: - only 1 20A outlet & no USB outlet nor 12V cigarette lighter style outlet - no built-in wheels to move it around aside from that it's great
@trumpdanusan11 ай бұрын
you do not want wheels or usb this is mans unit. Little lights and flashing meters are for cali crowd
@darthraider2483 Жыл бұрын
Link to this model
@waltfriedrich7631 Жыл бұрын
FYI...that is NOT the RV 30 amp plug.
@waltfriedrich7631 Жыл бұрын
FYI...this video is about the DUAL fuel not the gasoline only....and nobody said a thing about 50 amp@user-fw1lk7nw1j
@waltfriedrich7631 Жыл бұрын
@@slashdotjeo no it's not... I own the dual fuel model and it comes with the adapter for use with a tt 30 amp plug. Research instead of spewing BS
@waltfriedrich7631 Жыл бұрын
@@slashdotjeo such as? And if you had watched the videos all over the net you would have seen everyone that bought the dual fuel shown in this video got the adapter
@saleenr6 Жыл бұрын
Turn to run
@kbob7345 Жыл бұрын
You obviously have never started a Weed Wacker. 2 pulls with choke on, then 1 pull with the choke off. WHA'LA😂
@kevinaustin7537 Жыл бұрын
i was cringing when he kept pulling away
@tomg628410 ай бұрын
Never use the salid oil they ship with any genset. Use real quality engine oil.
@jjohnston66456 ай бұрын
If it won't start a rv ac unit. it's not worth having
@gabo2nd Жыл бұрын
Just order one for $180, brand new (supposedly). we'll see when it comes in
@darthraider2483 Жыл бұрын
Where?
@waqarwld Жыл бұрын
Did it arrived? How is it ?
@dwaincocopuff946 Жыл бұрын
It is still noisie...
@catman1dotcom11 ай бұрын
Purge the propane line first, then start on Run. Choke is more for gasoline starting. Also, invest in a magnetic dipstick and put that in, to collect the very fine metal shavings that get in the oil (especially during break-in). I recently bought this exact same unit for my boat. Getting ready to give it a start on gasoline first, then propane. Hopefully it won't take 40 pulls, I'm an old man and don't want that hassle, lol.
@marktwo31603 ай бұрын
Waaay to loud. No comparison to my honda. Why do u need electric start on a small inverter? POS
@Forged721 Жыл бұрын
Whole lot of power for a sleek little suitcase unit , sweet !!!! Surely there just making better n better inverters ,