Nice video again Tony!We need more 486 stuff.Have a nice day!
@tony3592 жыл бұрын
Thanks a lot! I have a Pentium motherboard on the pipeline! 🙂 and still working on that 386 board which I made part 1 about.
@alic2112 ай бұрын
hi dear , how you convert M/S to LPM L/min
@Tony359_22 ай бұрын
google :)
@alic2112 ай бұрын
Cubic Meters Per Second (m3/s)to LPM , you can convert ,, coz both are volume leaves the nozzle per time (sec or min),, cubic meter per second means like s cubic ballon has air 1m(length) X1m(width) 1m(height) leaves the nozzle per second
@tony3592 ай бұрын
to convert a speed to an airflow you need the size of the duct. How much volume is being moved depends on the size AND speed.
@alic2112 ай бұрын
exactly , you need the area of hose ,, Area of a circle A = π r² , 3.14X radius of hose , and the meter shows you m/s (Extech 45118)Air Velocity
@alic2112 ай бұрын
Calculating CFM or Velocity from Area
@From_the_mil2 жыл бұрын
Might check out the Atten ST-862D
@tony3592 жыл бұрын
I searched for a while before landing on the Quick but I understand the Atten is a valid alternative indeed.
@sudheerm.s67922 жыл бұрын
setting low air and temperature on channel 2 , is the solution to cool down the heater without parking on stand
@tony3592 жыл бұрын
It is. But I really don’t like that there is no way to stop it outside of the stand. I use a magnet around te handle, it fools the station thinking the handle is in the stand… it is a bit annoying though. Thanks for watching.
@sudheerm.s67922 жыл бұрын
@@tony359 Yes I watched a random video, one guy modified handle of quick 861 with switches and a remote control unit
@tony3592 жыл бұрын
@@sudheerm.s6792 Sounds like a good idea - not what you would expect from a not-cheap station though.
@From_the_mil2 жыл бұрын
Wonder how this one compares to the DW version
@tony3592 жыл бұрын
From my understanding the DW has a more reactive blower so it reacts much faster when speeding up and down. But clearly the DE needs a beefier blower. The rest is the same.
@Dave_____ Жыл бұрын
I think the Best BST-863 with @RandomHacks upgrade board is a better way to go. It is easy to change the air flow and temperature settings while the nozzle is away from the holder which solves a lot of your negative comments on the Quick station. Though the BST 863 does a bit lower air flow at 180 LPM.
@tony359 Жыл бұрын
Oh I saw that video, interesting. I don't think the massive airflow is such a feature tbh and yes, the inability to switch off the station unless the handle is back in the holder is annoying - as long as the constant speeding up to cool down. I think the Best is a good station, which one is best (ah-ha!) I can't say. I don't use mine very often so I can live with the downsides. To stop the airflow when the handle is not in its holder I use a small magnet to trigger the sensor inside the handle :) What matters to me is that it seems to be accurate and even. Thanks for watching!
@dorfschmidt48332 жыл бұрын
Bought an ATTEN ST-862D, because Louis recommended it. Has 120 l/m and a button. ;)
@tony3592 жыл бұрын
I admit the button would be helpful! :) But I also like my 200L/s, when using large BGA nozzles it's useful. I am still happy with the Quick - but the missing button is a big deal indeed!