No video

Reach In Cooler Refrigeration Pressures Explained

  Рет қаралды 11,335

REFRIGERATION KITCHEN TECH

REFRIGERATION KITCHEN TECH

Күн бұрын

In this video, I will go over refrigeration pressures for a cooler
/ rketec

Пікірлер: 46
@RedaReda-uk9lm
@RedaReda-uk9lm 3 жыл бұрын
Thanks a lot. That what we were taught in college.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 3 жыл бұрын
Np, thanks for watching
@saltrue1555
@saltrue1555 Жыл бұрын
Really awesome videos, I watch them every so often to memorize them, and God bless.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
👍
@erictello1
@erictello1 11 ай бұрын
To determine your auction pressure, do you use a desire box temp or the actual box temp displaying? Btw awesome videos! Thank you so much!
@LC-qi5ff
@LC-qi5ff 9 ай бұрын
System with txv = actual temp , capillary = desired temp
@Gary-ts6dh
@Gary-ts6dh 3 ай бұрын
2:30 - Is this one of those "Rules of Thumb" they talked about in class (350CFM per ton for airflow; 20 degrees SH on residential AC; Less than 250F discharge line temperature, etc)? Where to you get information about what the TD is for specific equipment? Is that a calculation? I've not been able to find this information anywhere. In school they taught us the calculation for TD; but, not what it is supposed to be for different equipment. I still have my RACT manual; but, it's not in there either. Is there a calculation I can do from the nameplate ratings?. The closest I could get is the BTU rating of the evaporator. I walk up to a box that appears to be functioning correctly: but, how can I be certain the designed TD is correct? Is it all a guess? or is there a way to know from a chart, maybe?
@mradam4572
@mradam4572 2 жыл бұрын
Great video thanks for your time and explaining
@garypoplin4599
@garypoplin4599 3 ай бұрын
2:33 - Where can the actual design TD be found? Is it just a ROT? Also do you use a different coil TD between a walk-in cooler and a walk-in freezer? Or both 10K? I heard the 30K CTOA from school for less than 10 SEER HVAC.
@canadiantailgater8218
@canadiantailgater8218 3 жыл бұрын
Good explanation
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 3 жыл бұрын
Thanks and welcome
@user-yw3rx5of9h
@user-yw3rx5of9h 10 ай бұрын
Good explaining
@maxmax-ui3ks
@maxmax-ui3ks 2 жыл бұрын
I liked your video. question: I have a kitchenaid fridge with dual evap and the freezer side only get to 15F and the fridge is fine at 37F. with the fridge compressor off and with the manifold connected to both hi/lo side the pressure reads 40PSI right away which means the pressures are equalized and there no obstruction, correct. ? are the pressure too high and that may explain why the freezer does not get to temp of 0F? is it worth to purge the freon and preform nitrogen pressure test?
@simohvac9222
@simohvac9222 3 жыл бұрын
great explanation
@davidanthony6065
@davidanthony6065 Жыл бұрын
Thanks for the videos! If you have txv instead of captube what should my TD and split be?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Current box temp minus Evap TD
@samjammal886
@samjammal886 Жыл бұрын
thank you sir
@maxmax-ui3ks
@maxmax-ui3ks 2 жыл бұрын
here some more info: The ambient temp is 73F & it equalized very fast when the compressor is off (< 5min). few minutes after the fridge was turn on the pressure went to ~1psi on the low side and then few minutes later to 10PSI , and on the high side it started at 90PSI and went to 125PSI. The compressor temp is slightly warm, i assume since it was just started, correct? after 20min with fridge running the low side is at -10PSI and the high side is at 100PSI, and the compressor is running at high speed and starting to heat up ,does it mean the system is under charged ?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 2 жыл бұрын
If it’s r134A could be low charge or a restriction
@maxmax-ui3ks
@maxmax-ui3ks 2 жыл бұрын
Well, This fridge happen to have hi/lo ports installed and I noticed very small bubble when using soapy water. I the removed the valve and found that both shredder valvves were leaking , the rubber ring around the valve were worn out completely. How could it be ? I will replace both and see if the leak continues. Thanks
@musakavalci9470
@musakavalci9470 2 жыл бұрын
Another excellent video. Thank you 👌🏼
@MrNebRebew
@MrNebRebew 3 жыл бұрын
What is the evaporator DT supposed to be for a newer domestic refrigerator with a linear compressor side-by-side unit with one evaporator in the freezer section?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 3 жыл бұрын
I do not do domestic. I had a commercial customer with a sub zero last year that I changed the evap coil on and the evap TD was 20. Might not apply to your application though unfortunately.
@sam-Moori
@sam-Moori 7 ай бұрын
Thanks a lot
@TheChecky1988
@TheChecky1988 3 жыл бұрын
Jesus Christ. You are goooooood.
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 3 жыл бұрын
Lol, thanks for watching!
@thefreshride1510
@thefreshride1510 Жыл бұрын
Thank you boss
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
👍
@yungchan8914
@yungchan8914 Жыл бұрын
So if the cooler has txv we can't use suction line pressure for diagnostic?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Ye would used current box temp minus evap TD as opposed to desired box temp minus evap TD
@ericksanabria168
@ericksanabria168 Жыл бұрын
How you determine desire box temp
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
It is generally 34F
@JM-wk2tz
@JM-wk2tz 2 жыл бұрын
What kind of hoses do you use, and you usually have to add pressure ports correct ?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 2 жыл бұрын
Yes, we braze in access port. I use smart probes for any critically charged system
@JM-wk2tz
@JM-wk2tz 2 жыл бұрын
@@REFRIGERATIONKITCHENEQTECH thanks, it’s a lot of work in the beginning huh, having to recover then add back refrigerant, it’d be cool to see a video of where you place the ports
@joselozano8499
@joselozano8499 2 жыл бұрын
You always use 30 above ambient?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 2 жыл бұрын
Most older units use a 30F condenser air split, a lot of the newer stuff uses a 15F split.
@raviyadav8743
@raviyadav8743 2 жыл бұрын
Do you mean box temp , set cabinet temp ?
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 2 жыл бұрын
Box temp is the current temp of the cabinet. Set temp is your desired temp.
@ericksanabria168
@ericksanabria168 Жыл бұрын
How do you determine if you going use 10td and 20td 30td
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
The engineer will determine this. Reach ins are typically a 20TD
@vickreyc
@vickreyc 3 ай бұрын
Where do you find this split information? In the manual? Nameplates ?
@cesarvargas1758
@cesarvargas1758 2 жыл бұрын
70f plus 30 how does that equal 124 i must have missed a part
@REFRIGERATIONKITCHENEQTECH
@REFRIGERATIONKITCHENEQTECH 2 жыл бұрын
70F + 30F =100F which equals 124PSI on our PT chart
@AVirgoserviceTech
@AVirgoserviceTech 2 ай бұрын
You forgot to say a recovery process have to be done each time
@thejedibunny4802
@thejedibunny4802 26 күн бұрын
Not on r290 or r600
Walk in Cooler is not Cooling. Rebuilding a TXV.
17:16
REFRIGERATION KITCHEN TECH
Рет қаралды 15 М.
Walk In Freezer is Slow To Cool
16:17
REFRIGERATION KITCHEN TECH
Рет қаралды 13 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 32 МЛН
What will he say ? 😱 #smarthome #cleaning #homecleaning #gadgets
01:00
At the end of the video, deadpool did this #harleyquinn #deadpool3 #wolverin #shorts
00:15
Anastasyia Prichinina. Actress. Cosplayer.
Рет қаралды 15 МЛН
REACH IN COOLER REFRIGERATION PRESSURES TROUBLESHOOTING
11:17
REFRIGERATION KITCHEN TECH
Рет қаралды 17 М.
GRAB N COOLER is running warm
7:49
REFRIGERATION KITCHEN TECH
Рет қаралды 3,1 М.
True 3 door Cooler is not Cooling
13:16
REFRIGERATION KITCHEN TECH
Рет қаралды 19 М.
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,1 МЛН
Basic walk in box control wiring
12:30
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 57 М.
WALK IN FREEZER NOT WORKING
33:18
HVACR VIDEOS
Рет қаралды 57 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 28 М.
WALK IN FREEZER DEFROST ISSUE
34:29
HVACR VIDEOS
Рет қаралды 104 М.
Superior / True TS-72F - 3 Door Freezer NOT getting cold enough.
17:21
OcRefrigeration , Hvac & Electrical Video's.
Рет қаралды 5 М.
True Reach In Freezer Evaporator Coil Freezing Up
10:13
REFRIGERATION KITCHEN TECH
Рет қаралды 17 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 32 МЛН