You can add a subtitle in your language to this video. Learn how: support.google.com/youtube/answer/6054623?hl=en
@agoniaXdunya4 жыл бұрын
Big ups!
@ricardogarcia39004 жыл бұрын
Excellent !. I will try ...
@gunnerjonah71833 жыл бұрын
I dont mean to be so off topic but does anyone know a way to log back into an Instagram account? I somehow lost my account password. I love any tips you can offer me.
@tateemmett38463 жыл бұрын
@Gunner Jonah Instablaster =)
@gunnerjonah71833 жыл бұрын
@Tate Emmett I really appreciate your reply. I got to the site through google and Im waiting for the hacking stuff now. Seems to take quite some time so I will reply here later with my results.
@yassershubber61934 жыл бұрын
Realpars no words can express our gratitude and appreciation for you and the method employed to simplify instrumentation as you do, hats off
@realpars4 жыл бұрын
Thanks for your support, Yasser! That is amazing to hear.
@CharlesTaylor-t1x20 күн бұрын
This takes time, real effort, and resources, yet it's free. If there was a word more sincere than "thank you" I would say it.
@realpars20 күн бұрын
Thank you so much for your kind words!
@MrWaalkman4 жыл бұрын
One of the best descriptions of this process that I have seen. Truth be told, calibration is usually either skipped entirely, left to the engineer to fudge in the code, or farmed out to a third party to be done. But it's easy enough that it need not be. Excellent work!
@realpars4 жыл бұрын
Thanks a lot for sharing that with us!
@richmond48844 жыл бұрын
I m always watching every video you have and always reviewing it for my work
@realpars4 жыл бұрын
Happy to hear that, Richmond! Great to know that our course videos are beneficial to you! Feel free to contact us if you have any questions along the way. Happy learning!
@reshmaravikumar80924 жыл бұрын
I am also interested in your videos. I daily watch your videos. Best and simple explanations.. Can I know if ladies have any chances after llcompleting automation plc course
@ganagamvrksantosh57254 жыл бұрын
It was a great gesture from REALPARS for teaching us. I am following ur videos regularly. Can give guidance on designing side
@realpars4 жыл бұрын
You're more than welcome, we're happy to hear that you are enjoying our course videos! Happy learning!
@jnb8918 Жыл бұрын
Very good video, great explaination. However, it seems the rotating directions to open and close manifold valves are reversed ? Opening is normally counterclockwise and closing is clockwise rotation. I see the reverse in the video, or is it a optical illusion ?
@realpars Жыл бұрын
Thank you for your question. While this might be accurate when considering plumbing fixtures, the scenario could differ when dealing with industrial devices, particularly due to the distinction between left and right-hand threads. The instructor in the video based their demonstration on their experience with a specific device at the time. For accurate installation guidelines, it's always advisable to consult your user's manual. The suitability of the threading may also vary depending on the vibration levels in the device's operating environment. I've included some links that might further aid your understanding on this topic. accu-components.com/us/p/119-left-hand-vs-right-hand-threads-which-is-best#:~:text=A%20left%2Dhanded%20thread%20is,even%20under%20anti%2Dclockwise%20forces. www.mcmaster.com/products/left-hand-threaded-pipe-nipples/
@Fatboy534 ай бұрын
@@realparsBS. Just admit your vid is wrong. Who makes reverse threads on valves? Anderson Greenwood? Please.
@MM-vi9kh3 жыл бұрын
Great thanks to you RealPars. 6:35 Please, take an example of 75%... I tried, but I got different answer
@cck07284 жыл бұрын
Excellent work. What is the purpose of equalising valve? Thanks for your valuable reply.
@gg00ddyy4 жыл бұрын
I hope you could've explained the reason behind the sequence in the manifold safe operating procedure on removing and returning the DP TX in service. But still great videos from Real Pars.
@realpars4 жыл бұрын
Hi John, When the transmitter is removed from, or returned to service, the valves are operated in a sequence to ensure that the delicate DP cell membrane is not damaged from excessive pressure.
@DiogenesNephew3 жыл бұрын
@@realpars Would this not also be achieved by isolating the high and low side first and then equalizing?
@muhamadsherko8801 Жыл бұрын
To avoid connecting the transmitter to the process in one sode i mean if your transmitter conected to hight or low side at different time so it will damage your diafragm because pressure applied to one side of it
@salmanfaris90844 сағат бұрын
wanna ask a question, after we remove the service and remove the transmitter, before do the calibration, need to put it back to service ?
@earlgreen66444 жыл бұрын
I really like your video series. I believe your red arrows depicting the manifold valve operations are incorrect in this video. It should be counter-clockwise to open, and clockwise to close ("Lefty Loosey, Righty Tighty").
@realpars4 жыл бұрын
Earl, thank you for your comment. Yes, I believe you are correct.
@paulmichaux71362 жыл бұрын
I thought that too
@maruthanilam24484 жыл бұрын
Sir. You are great. God bless you.very very useful videos for me and others.
@realpars4 жыл бұрын
Thanks for your support!
@mbolla1824 жыл бұрын
Me encantan tus videos. Saludos de Paraguay
@realpars4 жыл бұрын
Gracias, Manuel!
@santiagomachado51744 жыл бұрын
I can do a SCADA project thanks to this!!! Thankyou very much!!!
@realpars4 жыл бұрын
That's great, Santiago! Happy learning.
@sarantb89364 жыл бұрын
Please make clear the sequence and significance of valve isolation before and after the calibration, more over what will happen if I open the equalizer valve before closing the LP side isolation?
@eissa.f2 жыл бұрын
Thanks for your videos! I have a question: why did the 8 mA current output give us (25%)?
@realpars2 жыл бұрын
Hi Eissa A. Thanks for your question. Please refer to the calibration table at 02:50 of the video. The actual differential pressure is 50 inches WC which is 25% of the differential pressure range. So, 25% of the 4 to 20 mA output range is 8 mA. I hope that helps! If not, don't hesitate to reach out again.
@eissa.f2 жыл бұрын
@@realpars oh I missed that! yeah that makes sense now. Thank you for your help
@ricardogarcia39004 жыл бұрын
All your videos are great. Congratulations. Only one bug at 4:57 (DP must be 12.5 in WC).
@realpars4 жыл бұрын
Hey Ricardo.....you have a very keen eye! In the animation, we should be showing a current value of 13 mA, not 5mA. If the current flow is 5mA, the DP is indeed 12.5 inWC. Thanks for pointing that out.
@G-ALM Жыл бұрын
Great video, how ever, while we connect the hand pump and applying the pressure, the equalisation valve shall be opened or closed?
@realpars11 ай бұрын
Hi there, Thank you for your question; it's a great one. However, I want to clarify that the information we provide is meant to illustrate the process rather than serve as an instruction manual for the specific device you'll be working with. Therefore, the best course of action would be to follow the directions outlined in your device's user manual or reach out to the vendor for assistance. We're here to help if you have any further questions or need guidance.
@G-ALM11 ай бұрын
@@realpars Great. Thank you , Sir
@RS_834 жыл бұрын
Why at 1:20 are you closing first the low pressure block valve? I think you need to open the equalizing valve first, in order to prevent damage to the dp cell. Am i not right?
@realpars4 жыл бұрын
The method in the video is correct. First, the low pressure valve is closed, which keeps the current pressure on the low side trapped against the capsule. The output of the transmitter is maintained near the current value. With the low pressure valve closed, the equalizing valve can be opened, so the differential pressure is reduced as the pressure on the low side equalizes to that on the high side. Finally, the high pressure valve is closed. With the equalizing valve still open, the excess pressure can be bled from the capsule to make it safe to remove or calibrate.
@RS_834 жыл бұрын
@@realpars yes, you're right. Thanks!
@IKENNA36911 ай бұрын
@realpars what if you open the equalizer valve first then close the lp block valve and close the hp block valve.
@RS_8311 ай бұрын
@@IKENNA369 i think pressure from the hp side will go to the lp side. Maybe this will not damage the DP cell itself, but nevertheless it's not the best technique anyway
@ramgr68883 жыл бұрын
Very excellent explanation. Thanks for your videos. Will support continuosly....keep to create a new video about instruments....
@realpars3 жыл бұрын
Thanks a million, we appreciate your support!
@dedyapria11772 жыл бұрын
At 01:20 why don't you close the high pressure block valve first instead?
@realpars2 жыл бұрын
To ensure that pressure is equalized on both sides of the DP cell.
@dedyapria11772 жыл бұрын
@@realpars what if I close the high pressure block valve first then open equalize valve and finally close the low pressure block valve?
@tomas89673 жыл бұрын
Excellent video, I would just like to know why or based on what steps are performed to leave out of service a differential pressure transmitter?
@realpars3 жыл бұрын
Hi @Tomas Morales Perez. Sorry, I'm not sure I understand your question. Are you asking about the reasons why removing from service is performed in that order?
@ramgr68883 жыл бұрын
Nice video. Super explaination.
@realpars3 жыл бұрын
Glad it was helpful!
@ranadipghosh40084 жыл бұрын
Many thanks for an excellent instrumentation video. Your explanation method is commendable. Would highly appreciate if the calibration chart and relevant values could be in SI units.
@realpars4 жыл бұрын
Thanks for sharing your feedback with us!
@marlockflein12872 жыл бұрын
Hi,I don`t find the app,did you change the main image?,because I can`t find it.
@realpars2 жыл бұрын
Hi Marlock, We have recently optimized our learning platform which includes some highly requested features. We are happy to bring you these new improvements which will grant an even better learning experience, as a result we had to decide to no longer support the RealPars App. You can use our webpage to continue watching the video courses. Hope this helps, and happy learning!
@divyangpatluwala74253 жыл бұрын
please give some more information about root extractor..Why we use that root extractor method..
@realpars3 жыл бұрын
Hi Divyang, Thanks for your comment and topic suggestion. I will happily pass this on to our course developers! Happy learning!
@radyajatmikaristananda2197 ай бұрын
This procedure same for DP Level Transmitter?
@realpars7 ай бұрын
Thank you for your question! Yes, it is similar. Please refer to the user manual for detailed calibration procedures and instrumentation instructions. Happy learning!
@asadiqbal874 жыл бұрын
thanks real pars
@natasciacarboni8864 жыл бұрын
I think...the real value of current output at 50% of flux is 12 mA because : (20 - 4)= 16...the half is 8 mA that should be added to 4 mA. The real value of current output is certainly 12 mA. Many thanks to your videos.Little imprecisions give us way to open own mind. I'm sorry for my bad english.
@realpars4 жыл бұрын
Hi Natascia! As you say, we want the current output to the PLC to be 12 mA at 50% flow. Unfortunately the flow transmitter will not give us 12 mA, but gives us a current of 8 mA. If we connect a Square Root Extractor to the flow transmitter, we now get a current output of 12 mA.
@asadiqbal874 жыл бұрын
@@realpars yes u are wright
@waqashabib16743 жыл бұрын
Very well explanation....
@realpars3 жыл бұрын
Thank you!
@rajanbhatt56334 жыл бұрын
Again good video sir 👌👍. Next topic as AC or DC reply. Thanks
@realpars4 жыл бұрын
You're very welcome!
@athilaldurry58804 жыл бұрын
Excellent videos, many thanks
@realpars4 жыл бұрын
Thanks a lot! Happy learning!
@ijaL0611 Жыл бұрын
Thank you sir,, Your vidio very useful..
@realpars Жыл бұрын
Glad to hear that! Happy learning
@keyankeyan16054 жыл бұрын
really useful video keep going
@realpars4 жыл бұрын
Great to hear that, Keyan! Thanks for sharing.
@elshad20244 жыл бұрын
definetly agree #Keyan
@djaztec972 жыл бұрын
Why do you close the valves but open the equalizer in a specific order? I don't get it.
@realpars2 жыл бұрын
Hi @John. Thanks for your question. Bottom line, it's about attempting to maintain a close-to-balanced differential pressure across the sensitive diaphragm in the transmitter.
@muhamadsherko8801 Жыл бұрын
hellow everybody please I ve a question at the calibration , my quastion is that if we has an instrument like flow transmitter and after teasting we find out that the out put current is corsponding to the input at the zero input and full input for example transmitter which has input range from 0 to 100 gpm after teasting we got 4 mA from 0 gpm and 20 mA at 100gpm but when we cheach the instrument in 50 mA it does not produce 12mA it produce 13.4mA so how to calibrate this ?
@realpars Жыл бұрын
Thank you for your inquiry. Your question is quite intriguing; however, it's important to note that our videos primarily serve as foundational learning resources for understanding engineering concepts in the industry. They are not intended to replace the manufacturer's manual for your specific device. I recommend thoroughly reviewing your user and operator's manual for your device as a first step. This manual should provide detailed information tailored to your device's specifications and functionality. In the event that your issue persists after consulting the manual, I strongly advise reaching out to the manufacturer of your device for further guidance and assistance. They are the experts in their product and can offer specialized support to address your specific concerns. Before contacting the manufacturer, it's also worth checking all your wiring connections to ensure they are secure and free from any electrical interference. Electrical noise can sometimes disrupt the signal from your transmitter, and this aspect is occasionally overlooked. Ensuring correct grounding is in place can also make a significant difference in addressing such issues effectively. We appreciate your commitment to learning, and we hope you find the solution to your challenge. Happy learning from RealPars!
@generaltechnologyknowledge51654 жыл бұрын
Thanks for sharing
@realpars4 жыл бұрын
You're very welcome!
@denildavis35613 жыл бұрын
Where we connect pressure pump port. is it in vent side of manifold valve
@realpars3 жыл бұрын
Hi Denil. The pressure pump is connected to the High Pressure (HP) Port. The Low Pressure (LP) Port is left open, or vented to atmosphere.
@denildavis35613 жыл бұрын
@@realpars thank you
@paulmichaux71362 жыл бұрын
I'm just confused about the direction the arrows are pointing to open and close the valves. I thought turning it to the right would close it and to the left would open it,
@realpars2 жыл бұрын
Typically "turn right to close" and "turn left to open" would be proper. Always check the action of any device before operating it to ensure you know the "sense" of the device.
@paulmichaux71362 жыл бұрын
@@realpars thanks! Still an awesome video
@MM-vi9kh4 жыл бұрын
During calibration, should equalizer be open or close?
@realpars4 жыл бұрын
The Equalizer valve needs to be closed during calibration.
@nipunmadushan5320 Жыл бұрын
Superb
@automationadda37064 жыл бұрын
Which software are using in animation plz tell me.
@realpars4 жыл бұрын
Hi there, I am not sure about this as this is done by our graphic and animation department.
@mohammadabdulfattah18673 жыл бұрын
Sorry I'm not understand the last equation how 8 ma is converted to 12 ma .....is there a sample equation to calculate that
@realpars3 жыл бұрын
Hi Mohammad. The key to these conversions is to remember to keep all units in percentages. The output is equal to the square root of the input because of the square root extractor. An input current of 8 mA is 25% of the 4 - 20 mA range. If we find the square root of 25% (.25) we get 0.5. If we convert to the percentage we get 50%. 50% of the 4 - 20 mA range is 12 mA.
@kakangprabu007 Жыл бұрын
Thanks for information..
@realpars Жыл бұрын
You're very welcome!
@PhthaloBlue4211 ай бұрын
Why was pressure only applied to the high side?
@realpars11 ай бұрын
Thank you for your inquiry. The hand pump is positioned on the high-pressure side because it connects to where the fluid originates, meaning it's under high pressure. This setup allows us to measure pressure accurately from this side. Essentially, the pump emulates the flow pressure experienced by the sensor. If you're interested in learning more about such devices, I recommend checking out this link to a company that specializes in them. It could offer you further insight into their functionality and applications. www.omega.com/en-us/ Happy learning!
@maruthanilam24484 жыл бұрын
Sir. Pls make video for calibration of GWR type level transmitter.
@realpars4 жыл бұрын
Hey! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@senthil512 жыл бұрын
In play Store i couldn't find the App
@realpars2 жыл бұрын
Hi Senthil, We have recently optimized our learning platform which includes some highly requested features. We are happy to bring you these new improvements which will grant an even better learning experience, as a result we had to decide to no longer support the RealPars App. You can use our webpage to continue watching the video courses.
@eepower3 жыл бұрын
Can u plz add a link to your app.
@realpars3 жыл бұрын
Thanks for your comment! We have recently optimized our learning platform which includes some highly requested features. We are happy to bring you these new improvements which will grant an even better learning experience, as a result we had to decide to no longer support the RealPars App. You can use our webpage to continue watching the video courses.
@syedamaan27974 жыл бұрын
love from india
@Àhmåd-RM-1433 жыл бұрын
Fᴀɴᴛᴀᴅᴛɪᴄ❤️
@sufiyanalam98013 жыл бұрын
Thanks sir
@mustafasarhan5133 Жыл бұрын
Thanks, Very usefull
@realpars Жыл бұрын
Glad it was helpful!
@AeroDZ3 жыл бұрын
Fantastic
@realpars3 жыл бұрын
Thank you!
@AbdullahAhmed-vj2vi4 жыл бұрын
Thanks a lot
@realpars4 жыл бұрын
You're very welcome!
@mdnezamuddin62192 жыл бұрын
tnx
@jasonsprigg67224 жыл бұрын
This is a bit deceiving. You are not calibrating the flow meter with this set up, you are ONLY calibrating the pressure transmitter section of the flow meter. If the orifice plate or other components have issues this calibration will not help.
@realpars4 жыл бұрын
Hi Jason, you are correct. Any changes such as a different orifice plate would change our calibration values. That's why we've specified that we are calibrating the differential transmitter only using the given DP values and flow rates.