Recap of TN-C-S Earthing Arrangements and Measuring External Earth Fault Loop Impedance Ze

  Рет қаралды 92,286

GSH Electrical

GSH Electrical

Күн бұрын

Пікірлер
@deanpaterson301
@deanpaterson301 5 жыл бұрын
For someone who's just starting out - this is excellent information without the 'BS' - thank you
@amblernectar
@amblernectar 5 жыл бұрын
Really good video mate, thanks for taking the time to make it. As someone who's only recently qualified as a domestic installer I like these videos as refreshers if there's a big gap between jobs.
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Thanks so much for watching and commenting. Gaz 👍
@ZeeshanAliEngr
@ZeeshanAliEngr 4 жыл бұрын
Thanks for this informative video. The content of the video is very good. I am an Electrical Engineer from Pakistan.
@matthewread7220
@matthewread7220 5 жыл бұрын
Glad I found this channel, very informative in a concise way. Subscribed look forward to more videos
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Hi and thanks for the support Gaz 👍
@watsond83
@watsond83 4 жыл бұрын
I can see that clearly in the on-site guide. Good example. Thanks💪🏼
@AJBTemplar
@AJBTemplar 3 жыл бұрын
Very clear and straightforward. Thank you.
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Thanks 👍🏻
@alvinashman6371
@alvinashman6371 6 жыл бұрын
Great video Gaz, I prefer to croc onto the earthing conductor as in my strange little world, I think it provides a better contact point. It's good that you checked the functionality of the RCD test button 👍
@johnnomassive3797
@johnnomassive3797 3 жыл бұрын
Thank you for these videos you don't know how much your helping me . Many thanks
@ibrahimabdullah4430
@ibrahimabdullah4430 6 жыл бұрын
Very helpful and explained everything in detail. Thanks a lot GSH. 👍👍👍
@nicholasclarke8757
@nicholasclarke8757 5 жыл бұрын
On series 6 cut -outs there is a link bar within the neutral/earth chamber which for dno makes it adaptable for both tns or tncs earning arrangements. This can catch electricians out if no id sticker is at the service head. On occasions in the past a meter engineer may have fitted a second cut -out away from a communal set up into a flat for example . Using a series 6 cut-out ( which looks very similar to series 7 and 8 cut -out ) is very useful as it accommodates both earthing arrangements. It is however of little help to electricians who assume it is tncs as they both appear to be in the neutral chamber.
@bartman58
@bartman58 6 жыл бұрын
Another top of the drawer video.......I think you and photoinduction should do a blog together✌🏻️
@fattoamanowoodwork3638
@fattoamanowoodwork3638 Жыл бұрын
Love these videos. Thank you.
@lllCANDYMAANlll
@lllCANDYMAANlll Жыл бұрын
Is the 16mm squared earth cable labeled at 1:03 the actual PME? The way I understand it is the PEN conductor enters this enclosure and is then split by the PME giving us a separate earth and neutral within the dweling. Or is the PME simply an extra additional connections to earth along the length of the PEN conductor in case of a cable breakage making it a crude TT system? This seems the case from your video, I may have been told the wrong information in the past.
@Stop..carry-on
@Stop..carry-on 5 жыл бұрын
Great video , im not an electrician -it was interesting to see what you lads are actually doing and understand haha with out being bombarded with technical buzz words ( excuse the pun)
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Thanks for commenting and watching it’s very appreciated Gaz 👍
@Stop..carry-on
@Stop..carry-on 5 жыл бұрын
You make great videos , I’ve been also watching John ward to understand the different earthing systems ect /wiring - it helps to have an idea of what’s right and wrong - for eg an upside down door anyone can spot haha - but I noticed a copperpipe earthing clamp round the service cable on a job -which is obviously wrong . The original must of snapped off or something, But a couple years back I wouldn’t have known
@PompeyMatt17
@PompeyMatt17 5 жыл бұрын
0:44 that must have been one hell of a fly that hit that door 🤣🤣
@deniscotter525
@deniscotter525 4 жыл бұрын
Great video, appart from the end, you didn't put the earth cable back in to its terminal & emphasis the special importants of doing so.
@jordanparbery9096
@jordanparbery9096 6 жыл бұрын
Amazing thanks GSH
@CarFinanceSimplified
@CarFinanceSimplified 2 жыл бұрын
Great video thank you. I wish I could get my head around why the neutral and earth on the installation side aren’t linked? To me it looks like they are shorted out? Thanks!
@JasonEDragon
@JasonEDragon 3 жыл бұрын
I put on some eye protection any time that I make any type of contact with either a live conductor or heavy battery terminal.
@carlmarquardt994
@carlmarquardt994 3 жыл бұрын
Just to clarify... The line conductor which was the main incomer was live?? Dies the meter handle it when testing then? Also when I said out the Meter to impedance..is that not the same as ohms? Clear and concise lessons
@GSHElectrical
@GSHElectrical 3 жыл бұрын
Live conductors are both the line and neutral... if 10 amps flows in the line then 10 amps will flow in the neutral hence both live conductors 👍.
@feisal38
@feisal38 4 ай бұрын
Great information
@azajakal9614
@azajakal9614 5 жыл бұрын
Great video thank you for your help
@michaelcostello6991
@michaelcostello6991 3 жыл бұрын
At 3:39 you did not explain the extra wires/components present. Are these 2 meters ? Can you do some videos where the wiring is confusing like this ? Thanks for really great video. It was really informative and the Ze test at the end was excellent.
@echenduconfidence4998
@echenduconfidence4998 2 жыл бұрын
Great video
@LordRedDragon
@LordRedDragon 6 жыл бұрын
thank u very much for the information
@iansyme3535
@iansyme3535 5 жыл бұрын
Before you took off the cover why did you not throw the DP switch in the meter cupboard to isolate the consumer unit?
@GSHElectrical
@GSHElectrical 5 жыл бұрын
Hi. In this video I didn’t enter the consumer unit I was just showing the layout of the earthing arrangement. Thanks for watching and commenting Gaz
@echenduconfidence4998
@echenduconfidence4998 2 жыл бұрын
How do you carry out the test on TT system
@jamielightfoot8167
@jamielightfoot8167 6 жыл бұрын
When doing a pfc test at the consumer unit, main earth (16mm) will be put back in to the main earthing terminal and re tested with all parrellel earths connected for a true pfc? Not sure if I am correct. Look forward to hearing from your reply. Thanks
@GSHElectrical
@GSHElectrical 6 жыл бұрын
Hi. That’s correct this is the link to me doing that test. kzbin.info/www/bejne/e2fXgIqXbZuXfac Thanks for commenting and watching GSH Electrical
@syedbukhari9703
@syedbukhari9703 3 жыл бұрын
Thanks sir
@donnierobertson3088
@donnierobertson3088 5 жыл бұрын
Good work
@echenduconfidence4998
@echenduconfidence4998 2 жыл бұрын
Pls what if ur earthing arrangements is TT system
@mango3586
@mango3586 6 жыл бұрын
interesting information
@ezzaharelectrique
@ezzaharelectrique 2 жыл бұрын
When do we use this system and thank you
@GSHElectrical
@GSHElectrical 2 жыл бұрын
In most properties in the U.K. 👍🏻
@niallers8572
@niallers8572 6 жыл бұрын
I hope this video has been some help
@GSHElectrical
@GSHElectrical 6 жыл бұрын
What a lovely catchphrase I might steal it 🙊
@YankMcGill
@YankMcGill 23 күн бұрын
Can’t believe you are teaching students to do external Ze, with no PPE. A fault on the meter and you have, in your case, nearly 1000A through meter. You should be using insulated gloves and face shield as a minimum. Tut tut.
@RobertMartinez-po7vx
@RobertMartinez-po7vx 3 жыл бұрын
Excellent thank you
@nicholaspratt7934
@nicholaspratt7934 4 жыл бұрын
Excellent Thanks 👍
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН
Почему Катар богатый? #shorts
0:45
Послезавтра
Рет қаралды 2 МЛН
Types of Earthing System for Electricity Supplies (UK)
18:00
John Ward (jwflame)
Рет қаралды 473 М.
EARTHING a SHED or OUTBUILDING - TT - TNS - TNCS
14:39
LEARN ELECTRICS
Рет қаралды 98 М.
Can Your Installation Rely on a TT Earth Electrode
7:39
GSH Electrical
Рет қаралды 14 М.
Installing an earth Rod - New TT Supply
30:36
Residual Electrical
Рет қаралды 56 М.
TN-C-S Danger - Broken PEN Conductor (Combined Earth & Neutral)
9:50
John Ward (jwflame)
Рет қаралды 166 М.
Should You Install an Earth Rod?
6:17
eFIXX
Рет қаралды 89 М.
Understanding Earthing Arrangements - TNCS, TT, TNS
5:59
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН