IR are shortcutting separator filter. We cut open the separator and it was manufacturing defect. Also IR didn’t know about the thermal valve on the manifold. Even though it’s in the manual.
@boosted2.4_sky6 жыл бұрын
You guys are creeping up on 100k subs.... Won't be long...👍
@WorkshopAddict6 жыл бұрын
We are looking forward to the new year and hope it happens in 2019! Thank for your support.
@astc5933 жыл бұрын
Thank you! Your products are awesome!
@amirferouz46926 ай бұрын
should i use a magnetic switch with these?
@TheMrjames6196 жыл бұрын
thanks for the information
@SakichanHarduar11 ай бұрын
My compressor shutting down on airend temperature
@tamasirosimangunsong3153 жыл бұрын
How to repair if have oil leakage from inlet valve?
@rm_channel41692 жыл бұрын
Hi,same problem with our IR compressor.can you advise how to rectify the oil coming to out air pipe.
@jakobporterz32113 жыл бұрын
IR compressor are pain in the butt to work out. Changing out the Airend couldn't be easier on a IR.
@santosskumar77822 жыл бұрын
Oil throw out what problem
@muhammadsabirsabir37362 жыл бұрын
Oil throw out what problem tell me
@ayahadikyoutubetv95974 жыл бұрын
Hii brother.. I have UP5 15 10 screw compressor.. Capacity 2.07 m3/mnit my problm is my comp running but not load.. Pls tell me what should i check.. Really hope you can advise me on that