This recording show how to refill air conditioning fluid. Pressure should be between 120-130psi not 200psi as mentioned wrongly. Thanks for pointing it out!
Пікірлер: 127
@paulejakita4116 Жыл бұрын
Thanks a lot, this video came in very handy
@adnanahmad58752 жыл бұрын
Nice vid...very loud and clear...👍👍☝
@CityBoyLiew Жыл бұрын
Remember to subscribe and turn on the bell for notifications.
@lv59602 жыл бұрын
Thank you !!! Very well explained
@CityBoyLiew2 жыл бұрын
I’ll refer to this again when I need to do repair my AC.
@bebanhaba81673 жыл бұрын
thank you sir... such a good knowledge and technical for DIY... 👍👍👍
@CityBoyLiew3 жыл бұрын
You are welcome. Remember to subscribe to this channel to watch more DIY guides.
@bebanhaba81672 жыл бұрын
@@CityBoyLiew alright sir already subscribe your channel... Please visit my channel if you have free time😊👌 thank you
@ahmadizzazmohamadsofa54702 жыл бұрын
Perfect video.. excellent
@CityBoyLiew2 жыл бұрын
Thank you.
@andyh84402 жыл бұрын
I have 2 indoor units and 1 outdoor compressor. There’s 2 service valves on the outdoor unit. Which one do I connect to for 410a regas? Does it matter which service port I use for regas?
@CityBoyLiew2 жыл бұрын
Normally the service valve has larger diameter. Check if both have same larger diameter. If that’s the case then each one are for each indoor unit.
@andyh84402 жыл бұрын
Thanks for the prompt reply! Yes I checked both service ports are the same size both with the schraeder valve. But do I need to recharge both ports as it’s only 1 compressor. Or just by using 1 service port it can charge the entire system.
@thwaymaung8 ай бұрын
Thanks a lot brother
@CityBoyLiew8 ай бұрын
You may use an ammeter to double check if the fluid top up is at optimum level.
@pidasmimie54872 жыл бұрын
Nice ...good video...
@CityBoyLiew2 жыл бұрын
Also watch another video about fan motor not spinning. Video: kzbin.info/www/bejne/a3vMm5Jmn890ntk
@IndependenceCityMotoring2 жыл бұрын
Most gauge sets include two gauges (blue and red)- what is the other red gauge used for and why is it not needed here?
@CityBoyLiew2 жыл бұрын
3 horse power and above required. Household air conditioner normally does not required.
@wenjunlim8303 Жыл бұрын
Hi, do you turn on the a/c while filling the refrigerant gas? Or turn it off?
@CityBoyLiew Жыл бұрын
AC needs to be turn on. Compressor need to be running as shown in the video.
@raymondlooi2 жыл бұрын
Appreciate your efforts & very details! 1) Procedure will be the same for R22? 2) Any leaking issue after topped up?
@CityBoyLiew2 жыл бұрын
Slight difference. No need to turn the tank upside down. R22 is gas form. Good point to also check leakage using bubble test. So far the unit is working fine. It was a quick fix around 7:45pm. Didn’t have time to perform bubble test after topping up. Thanks for pointing it out. I will normally perform routine check once every six months during summer break.
@raymondlooi2 жыл бұрын
@@CityBoyLiew wow... You are expert! 🤠 I planned to grab those small size R22 (800g bottle) for the first try. Do you encourage me to get the smaller size one? About the leakage check, it seems easily to check (bubble test) at the outdoor unit (pipe joint). How about indoor unit? Do you mind to show us a little about it? Thanks in advance!
@CityBoyLiew2 жыл бұрын
It depends how many ac do you have at home. I did lots of KZbin research before DIY. As usual, safety first. Be sure you have personal protective equipment like gloves, test pen, goggles. Don’t get injured. Double check if electricity is totally off. Some old unit require Allen key to release the check valve. I made two videos about indoor unit. Made the second very recent only. Try look through from video list.
@raymondlooi2 жыл бұрын
@@CityBoyLiew That's cool! Thanks for the reminder 🙏🏼
@samuelchowchow51042 жыл бұрын
Hi hi, waa wondering u mentioned any reading between 110 to 200psi is low, seems like a great different mine read at 130psi is it low? BTW where u get ur gauge can't seems to find it. Thinking of DIY my top up. TIA
@CityBoyLiew2 жыл бұрын
Try google for Acson hardware shop. I bought form those air conditioner hardware store. 130psi should works too. Actually need to also check current but need additional tool. Be caution to purge the hose to prevent death volume of air being sucked into compressor.
@samuelchowchow51042 жыл бұрын
@@CityBoyLiew thanks bro
@CityBoyLiew2 жыл бұрын
The gas pressure will be high when the air filter is clogged. 130-140psi should be fine as long as it runs steadily when it is new. The fluid is also used for the compressor as lubricant as well as coolant. That’s why it needs to be top up from time to time.
@pirategod92 Жыл бұрын
Bos...when u topping up gas,the aircond compressor set to on aa?
@CityBoyLiew Жыл бұрын
Shut close all the door and windows. Connect the gauge as shown. Purge the air in the tube then top up. The compressor will have suction pressure only after three minutes it has been turned on. The outdoor fan starts is the signal. But don’t need to top up immediately. Wait for the outdoor fan to spin at normalized speed only start to read the gauge. Top up only if necessary. Look for these tell sign again from the video to have a better idea.
@markw3922 Жыл бұрын
can this be used on vehicle R134A system with correct quick coupler fitting ?
@CityBoyLiew Жыл бұрын
Need gauge for R134A and R134A fluid. Need to also check manufacturer data sheet for pressure to top up.
@bennygimsiongleow4606 Жыл бұрын
Hi there, need to get rid of the air in the yellow and blue pipe b4 topping up? Same psi for 1 to 2 and above?
@CityBoyLiew Жыл бұрын
Yes, purging prevent death air volume in the hose from entering the compressor.
@bennygimsiongleow4606 Жыл бұрын
@@CityBoyLiew any videos or link to show how to purge for both pipe?
@CityBoyLiew Жыл бұрын
Check the cover image. Point number one and two. Screw half way then flow gas from tank so that it pushes the air inside the hose out from the check valve. Then only to tighten the check valve screw.
@bennygimsiongleow4606 Жыл бұрын
@@CityBoyLiew Thanks
@mtay65 Жыл бұрын
Gas pressure is for reference only. Correct way is to check running current (read outdoor label) with a clamp meter when the compressor is at max load.
@CityBoyLiew Жыл бұрын
Thanks for the advise. Max load meaning set lowest temperature for indoor?
@mtay65 Жыл бұрын
@@CityBoyLiew yes
@ToothDoc20102 жыл бұрын
The charging you did was in the vapour (gas) line, so why did you turn the pink r410a bottle upside down? This would mean liquid going in to the vapour line and damaging the compressor. The bottle should be upright so hence gas charging going in to vapour line.
@CityBoyLiew2 жыл бұрын
The R410a variant is a mixture of different chemical blend in a specific ratio. Charging it with liquid (inverted bottle) helps maintain the ratio better than in gas state. Charging in liquid state is better in maintaining the life span of compressor. Open the valve slowly to allow liquid to be siphon out changing into vapor state once leaving the pink bottle. Turn open and close bit by bit until it reached 130psi and stable. It would normally takes roughly half an hour work.
@CityBoyLiew2 жыл бұрын
An example of liquid turns into gas that happens on pressure cooker: Vapor turns into very hot gases state in pressure cooker kzbin.info/www/bejne/eX-3mHWagr-brZY
@dimitrisfoti8962 Жыл бұрын
The air conditioning works on cold, hot or it doesn't matter. At what outside temperature is it recommended to charge with freon? For R32 what would be the normal value in PSI. Thank you!
@CityBoyLiew Жыл бұрын
It should be less than 120psi. Use an amp clamp to measure the optimum pressure required at maximum capacity.
@rodelsantos45 Жыл бұрын
Can have a question what the air conditioning is 410 a and charge with freon gas r22 what is the caused thank and advance
@CityBoyLiew Жыл бұрын
It is like blood to a person. A type A blood person can’t be given B type blood.
@rodelsantos45 Жыл бұрын
@@CityBoyLiew thank you very much I will flushing r22
@CityBoyLiew Жыл бұрын
Compressor designed for 410 can’t use R22 gas. It will damage the compressor.
@Anil-Veeramangalam2 жыл бұрын
Thanks
@CityBoyLiew Жыл бұрын
You are welcome. Does it helps solve your problem?
@michaelsolomon2534 Жыл бұрын
I appreciate your video broo, really need it rn... pls for a dual inverter R410a refilling, does i still charge to 120psi?
@CityBoyLiew Жыл бұрын
When the indoor unit coil is clean from any dust and the room is enclosed. The pressure should be around 120-125psi for this R410a. Partial of these fluid is also acted as lubricant for the compressor.
@michaelsolomon2534 Жыл бұрын
Thank you bro🙌... i bought Lg dual inverter ac 1hp, i complained it didn't cool so much when after it was installed, an Lg man came and removed gas from the system and i complained knowing it's stupid and the company promised to take care of it stating it was wrong of the employee, they sent another over and he says he's going to vacuum the system and charge it at 120psi... they are using a chinese brand of R410a gas.
@michaelsolomon2534 Жыл бұрын
Any advice bro?, the ac is just a week old
@CityBoyLiew Жыл бұрын
Oh…. I hope your problem is solved by now.
@michaelsolomon2534 Жыл бұрын
Yes bro, but i found out LG in this region uses Chinese R410a, and i guess that's the major reason it doesn't cool so good, other than that it's energy saving claims are actually good. The system was vacuum and gas was refilled
@johnrambo1294 Жыл бұрын
Boss for 1 HP panasonic inverter how much exactly for enough gas psi (R410a) and 1 more thing this single is for gas 410 32 gas only right
@CityBoyLiew Жыл бұрын
About 120psi for R410a. R32 around 115psi. This gauge for this two type of gases.
@johnrambo1294 Жыл бұрын
120psi is standard 1 HP inverter for R410 gas pink
@CityBoyLiew Жыл бұрын
Correct. Remember to purge the air prior to charging. Refer video for procedure. Not good if death air is circulate into the compressor.
@CGFUN8292 жыл бұрын
is it true that you have to vacum all gas befor refiling the r410?
@CityBoyLiew2 жыл бұрын
Just top up will do.
@tedlives2001 Жыл бұрын
How much psi for R32 gas should it be to refill split unit?
@CityBoyLiew Жыл бұрын
About 120psi. Almost same with R410a. Best to check ampere while refilling.
@dongjaime89785 ай бұрын
Boss what is the brand this unit An can we ask boss General unit what gas we use?
@CityBoyLiew5 ай бұрын
Watch the video again. There is a label at outdoor.
@Monagane1 Жыл бұрын
Only the R410a should be charged with the cylinder upside down.?
@CityBoyLiew Жыл бұрын
The cylinder will have instruction.
@albertsew2 жыл бұрын
hi .....is 2HP aircond also between 117 to 200psi ?
@CityBoyLiew2 жыл бұрын
Ideal to be at 120psi to 130psi. I think I mentioned wrongly to be 200psi. Yes regardless of the horse power. Amount of gas is larger as well as area.
@albertsew2 жыл бұрын
@@CityBoyLiew thanks for your reply. wat about R22 gas, what is the psi range ?
@CityBoyLiew2 жыл бұрын
R22 will be between 60-70psi will do.
@HSQ786 Жыл бұрын
is this 1.0hp? mine is 1.5hp i find on other video they saying need to fill max 150psi....i m confuse...please advice ...thanks
@CityBoyLiew Жыл бұрын
Best is to use an ammeter. Stop once it has reached the optimum ampere. Normally around 120-130psi. Be sure the coil is clean. Door is closed.
@HSQ786 Жыл бұрын
@@CityBoyLiew... I didn't get the answer ..tis video for fillup 1.0 HP right..is 1.5 HP inverter Aircon have same 120psi gas or need to add more ?
@CityBoyLiew Жыл бұрын
It is using same type of gas?
@okanefirenet65342 жыл бұрын
require to turn on the aircond during charging ?
@CityBoyLiew2 жыл бұрын
Compressor need to run at constant speed.
@MaxMax-ti3xs2 жыл бұрын
Hello.. non inverter r410 also 120psi ?
@CityBoyLiew2 жыл бұрын
Bare in mind, fluid pressure affected by surrounding temperature. At 30deg Celsius, R410A set around 120-140psi should work just fine while the AC is running. Ideally, charging by weight is the best way.
@raymondlooi2 жыл бұрын
Bro. I was having fun of charging the refrigeration gas yesterday, haha. It seems successful! Now, let the AC run for 3-4 days then check again whether leaking?! BTW, when I detached the hose from charging port (gas input port), some yellowish oil came out with the gas! What does it mean? 🤷🏻♂️ (R22)
@CityBoyLiew2 жыл бұрын
R22 need stable at 60-70 psi only. If it stayed within this range should will be alright. Refrigerant gas acts as cooling as well as lubricant for compressor.
@CityBoyLiew2 жыл бұрын
I just fixed my outdoor fan motor issue today. Editing the video. Hope to publish by Friday.
@raymondlooi2 жыл бұрын
@@CityBoyLiew does it mean, there is nothing wrong ( yellowish oil)? And, Everytime charging Gas, lubricant oil is inputting together with the Gas? (Yes, I charged till 60-70psi).
@raymondlooi2 жыл бұрын
@@CityBoyLiew wow... Cool! Repair or replace? Aiyaya, I should video-ing also ya! Haha.
@CityBoyLiew2 жыл бұрын
The gas will turns into liquid act as lubricant.
@rolandchan102410 ай бұрын
Where do u get the r410gas
@CityBoyLiew10 ай бұрын
Those Air-Cond hardware shop.
@vindis79 Жыл бұрын
Doesn't the pressure depend on the temperature?
@CityBoyLiew Жыл бұрын
Yes indeed. Try check pressure or top up during the same season of the year like summer morning every year.
@rolandchan102410 ай бұрын
my unit is Mitsubishi unit. What is the required PSI? thank you
@CityBoyLiew10 ай бұрын
Gas model changes based on year. There is a label located around the unit. Try look for the label. Normally R followed by numbers.
@CityBoyLiew10 ай бұрын
The gas pressure depends on the gas used.
@rolandchan102410 ай бұрын
@@CityBoyLiew mine is the R410. installed in 2016
@CityBoyLiew10 ай бұрын
Should be between 110-140psi. It is recommended to also use an ammeter for optimum gas pressure. Maybe I should made another video on this topic.
@rolandchan102410 ай бұрын
@@CityBoyLiewwhere to buy this kind of pressure gauge
@skenderkaculi9175 Жыл бұрын
Thanks okej
@CityBoyLiew Жыл бұрын
Welcome to check back for more informative video content.
@thebossnadjib67819 ай бұрын
I did exactly what you said and it didn't made it cool , what could be the problem
@CityBoyLiew9 ай бұрын
Check ampere test see if it is at working range. Be certain that the gas is correct for your unit!
@CityBoyLiew9 ай бұрын
Is the cooling fan start spinning?
@user617a6d62 жыл бұрын
R32 what psi needed for 1hp
@CityBoyLiew2 жыл бұрын
Suction pressure to be at 115psi. Charge slowly by turning valve on a little bit by bit. Test for leakage using bubble test after you have done charging. Pressure stabled at 115-120psi. Too high the compressor will shutdown automatically until cooled down again. Good luck.
@user-pt6gk9cf7k10 ай бұрын
Would u please i need to have a course with u cant i
@CityBoyLiew10 ай бұрын
Try to watch it again. Let me know which part you wish to know more. I try made another video to elaborate, if necessary.
@shanejrwoo97442 жыл бұрын
Bro changing gas pipe leak how? I charge 401 like u teach nowaday 1 mth charge once -.-
@CityBoyLiew2 жыл бұрын
Definitely a leaks. Try bubble test at joint. Soap water and sponge/ brush and apply onto the coupling joint. Suspect a leaks. Charging every month it is because the pressure always very low?