@UltimateDIY
@UltimateDIY 9 ай бұрын
🚨 NEWS from Refoss: a firmware update has been released that enables Home Assistant functionalities 🚨
@AlessandroCaporale
@AlessandroCaporale 8 ай бұрын
Finally. I was looking for that
@dakshkukkar2150
@dakshkukkar2150 5 ай бұрын
Is this a good product with home assistant? As in the accuracy and the data polling is up to par with products like shelly?
@AlessandroCaporale
@AlessandroCaporale 8 ай бұрын
Actually I strongly recommend to avoid those. I bought 4 of them, having installed by qualified professional under my supervision (CT direction and wiring for each phase/voltage correlation). I get incoherent data, showing negative values on some phases that doesn't make any sense. The weird thing is that I see correct current data, but power is calculated as negative due to a "PF" (power factor) with negative value (in my case -0,87). If I try to reverse the CT, the value get positive but with very wrong value due to PF going to 0,20 !! I tried contacting REFOSS who doesn't reply emails or contact forms. Now I have to returns those useless devices after I spent money for the installation. -edit : solved due to incorrect wiring from professional AND ct probe reversed (on some you need to follow the arrow direction and on some others you need to reverse!)
@UltimateDIY
@UltimateDIY 8 ай бұрын
Wow! Sorry to hear about your bad experience. Mine seems to be working perfectly on single phase, so can't comment or advise about other scenarios, sadly.
@UltimateDIY
@UltimateDIY 8 ай бұрын
Hello. Refoss just informed me that they tried to reply to you message here, but something went wrong and the message does not appear. Please contact them on yvette.yin@meross.com
@AlessandroCaporale
@AlessandroCaporale 8 ай бұрын
@@UltimateDIY thank you, I solved the issue and edited my previous comment. Thank you for helping!
@UltimateDIY
@UltimateDIY 8 ай бұрын
Awesome. Glad the problem is solved 👍🏻
@dakshkukkar2150
@dakshkukkar2150 5 ай бұрын
​@AlessandroCaporale how did you fix the problem?
@kactycbbulbash3344
@kactycbbulbash3344 3 ай бұрын
Does it keep a voltage (Current) history in the app? At least for some time? Or only consumption?
@UltimateDIY
@UltimateDIY 3 ай бұрын
As far as I can see, only consumption.
@kactycbbulbash3344
@kactycbbulbash3344 3 ай бұрын
@@UltimateDIY was hoping to debug my solar problems. Do you know a product which keeps some Voltage history and also does the consumption?
@UltimateDIY
@UltimateDIY 3 ай бұрын
Sorry, but I don't know any.
@AddiAtze
@AddiAtze 4 ай бұрын
Just installed all 6 current probes, with direction of energy K->L. But, as other comment stated, the wattage is completely random. I cant tell anything from those values. Voltage is positive 234V, current positive 0,63A, wattage -136. I made sure I had "voltage lines" on the same phase as the current probes. This is annoying.
@UltimateDIY
@UltimateDIY 4 ай бұрын
Where you have a negative reading rotate the probe and all will be solved.
@AddiAtze
@AddiAtze 4 ай бұрын
@@UltimateDIY that is logical. What bothers me is, why print directions on the Probe if they are wrong?
@AddiAtze
@AddiAtze 4 ай бұрын
Or why not give the Option to change sign in the Software?
@UltimateDIY
@UltimateDIY 4 ай бұрын
That is beyond me 🤷🏻‍♂️
@YinYvette
@YinYvette Күн бұрын
@@AddiAtze We apologize for the incorrect directions on the EM06 Probe. The issue with the reversed current direction was discovered and rectified promptly, and we have updated our product instructions. If you're still experiencing this problem, please contact our official email, and we'll assist you with a solution or compensation.
@AndrejRifler
@AndrejRifler 4 ай бұрын
Can someone tell me what's the sampling rate for this units ? I need it to be much less than 15 min. I would like to use it to inform me when the 15 min power will exceed some value, so I need to do aggrregates using higher granularity. Anyone ? I can't find this data anywhere...
@UltimateDIY
@UltimateDIY 4 ай бұрын
Send an email to the manufacturer and they should be able to provide this info.
@YinYvette
@YinYvette Күн бұрын
Regarding your question about the polling interval or update frequency of the EM06 device, the data acquisition frequency for this device is 4 seconds. The refresh interval in our app is approximately 3-18 seconds, with the fastest refresh being every 3 seconds. If you are experiencing a refresh time of 20 seconds in the app, it may be due to a request timeout, as the app's request timeout is set to 15 seconds.
Emporia Vue Energy Monitor - Gen 3 vs. Gen 2 - NEW FOR 2024
16:52
Умное освещение на Zigbee
19:36
План ГОЭЛРО
Рет қаралды 754 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
Installing a Home Energy Monitor - The Emporia Vue2
15:19
Aaron's Test Lab
Рет қаралды 18 М.
Home Assistant Has Never Been This EASY!
11:58
Everything Smart Home
Рет қаралды 177 М.
Worst fake "power saver" plug yet
9:52
bigclivedotcom
Рет қаралды 636 М.
Smart Home Energy Optimization
18:32
Home Automation Guy
Рет қаралды 39 М.
КАКОЕ СОЕДИНЕНИЕ ПРОВОДОВ ЛУЧШЕ? #энерголикбез
23:11
Александр Мальков
Рет қаралды 1,2 МЛН
How To Install A Home Energy Monitor | Emporia Gen 2 Vue
10:22
Everyday Home Repairs
Рет қаралды 70 М.
You don't want these smart plugs
27:13
Fix This Build That
Рет қаралды 482 М.
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН