Thanks for the video. Please explain what that accumulation pipe purpose.
@aldovanzyl-jackofalltrades84462 ай бұрын
@malekutumafa5124 It is a pleasure. It is for oil deposits that finds it's way through the system. So that it doesn't get lodged in the capillary tube.
@kreyolappliance14692 жыл бұрын
Great job. Great explanation.
@LucioDMann Жыл бұрын
Love it, great work. How have the unlike metals treated eachother over time?
@aldovanzyl-jackofalltrades8446 Жыл бұрын
Its been running for a few years, runs very well, no issues.
@SUDeltaS3 жыл бұрын
thanks for the video. im gonna try build a small basin filled with 1 deg c water for ice dipping my arms in to cool down
@mikhailtronik43222 жыл бұрын
Lol what, run a refrigeration system just to cool off your arms?
@originmokoena32833 жыл бұрын
Nice video. I rebuilt a few like that even household refrigerators. They work like charm. But i use aluminium tubing instead of copper since its cheaper.
@mikechristie-fogg20644 жыл бұрын
Could one take the guts from a smaller chest freezer and build a slightly bigger, but much better insulated box for it? I have access to a free, but smelly, small working freezer but I want a bigger one. I'm a pro cabinetmaker so I could make a nice tight box. I could add 4" or 6" of insulation and make sure the door seals perfectly.
@taiwanluthiers Жыл бұрын
Is it worth it to recoil a deep freezer if the evaporator coil is messed up for whatever reason? What about the condenser? Is it worth recoiling those?
@aldovanzyl-jackofalltrades84468 ай бұрын
I wouldn't bother with the condenser tray.... the inside pipes is the only ones worth doing. If you compressor is good, but it sprung a leak. You only looking at the cost of the pipes. And obviously your time.....
@babalolaolawalehakeem34533 жыл бұрын
Good job sir, pls, my question is what can be d real cause of freezer that is half frozen? My freezer only freezes at top part, the middle down to the bottom only cold and I just changed the compressor. Thanks sir
@aldovanzyl-jackofalltrades84463 жыл бұрын
Might be too little gas, or blockage in the pipes. Did you flush the lines out with the right solvent?
@sanjitparjapat472 жыл бұрын
Good job sir
@aldovanzyl-jackofalltrades84462 жыл бұрын
Thanks for watching!
@mrvvrm59514 жыл бұрын
Thanks for the video. I have some questions at 6:00 you said most fridges (isnt it a freezer?) have more tubes than your 29 mtr. I have taken out my ice vitrine completly and it amazed me howless tubing it got alaround in pur foam just two tubelines. And i guess they where there only where hands make contact so it feels could at the outside, but has noting to do whit cooling the vitrine. And about that black iron thing on your fridge to cool off heat. I dont got it on my ice vitrine can you explain that. Because it is a big profeaional ice vitrine. Why i want to know all of this i i wanted toakr something like you did and you said fridges have more tubing MORE THAN THAT WHAT YOU GOT. What i have to do than for a FREEZER. and why this icevitri e is so big and have so lesa tubeing while itsl says to freez dow to minua 36 degrees. Can you help me further thanks anyhow Michel
@aldovanzyl-jackofalltrades84464 жыл бұрын
Hi there. Yes sorry meant to Freezers. All depends on gas volumes. And that is calculated by the size of your compressor in the freezer. I use 6mm copper tubing, so it has low volume, most freezers have 8 or 10mm tubing, normally aluminum is used, and that's cheaper but aluminum doesn't last. The oil found in the compressor causes corrosion. Copper lasts a lifetime. The black thing? Are you referring to the accumulation chamber? Trick I picked up from a old professional mechanic. The oil in the compressor sometimes finds its way into the pipes. Because I use 6mm tubing it has a narrow path , oil could clog the flow. So the accumulation chamber is like a catch box of sorts. Hope it helps! Thanks for commenting!
@bluefin96584 жыл бұрын
Can I do it with R600a compressor 120L chest freezer. What would be the required on n off gas pressure??
@shahzadahmad93284 жыл бұрын
Good job. sir! tell me please evaporater pipe line size and pipe linth feet.and compressor size.???
@I_Iza_BOSS5 жыл бұрын
What are the list of parts to build a chest freezer from scratch?.. I know you need a compressor copper tube a condenser and fan an evaporator and fan thermostat.. capillary tube..r410 refrigerant...
@aldovanzyl-jackofalltrades84465 жыл бұрын
yes all sounds right, but remember to use the right refrigerant for the type of compressor you bought, I use R600A or R134A
@ShopperPlug3 жыл бұрын
How do you know which capillary coil is needed and what size? same goes for the compressor, evaporator and condenser.
@aldovanzyl-jackofalltrades84463 жыл бұрын
Formulas are how the old school guys were thaught. My knowledge is all trail and error. Capillary length and size determines the flow rate, the quicker the flow the weaker the cooling, the slower the flow the better, but not too slowly. There is a sweet spot.
@zaidmalik7956 жыл бұрын
how many used evaporator piping size lenght
@benjaminthomas26262 жыл бұрын
Bakgat boet, n man wat Kan verduidelik. Vele dank
@aldovanzyl-jackofalltrades84462 жыл бұрын
Thanks man. Waardeer. Net n plesier.
@SanjibDas-ct2wr5 жыл бұрын
We know today's deepfreezers either have alumunium or iron evaporators and condensers but had it been a copper evaporator inside puff insulation ( time of 1st make ) then 1. what is the probable percentage of leakage? 2. Or even puff insulation do cause any chemical reaction to perforate the copper evaporator. I have watched your video along with many other videos but amazed to your good quality job and thrrow knowledge with confidence, so I request and if you may answer to my these two queries.
@aldovanzyl-jackofalltrades84465 жыл бұрын
Thanks for watching and responding. In my experience IF copper was used it would last forever, but copper is expensive and that's why it isn't used when built by manufacturers. They want it to break. The puff insulation has no chemical reactions I believe, but seals the moisture build up on the pipes in and this causes rust. See some of my other videos for that. I just love fixing the unfixable, and don't really care if it cost me a lot. Its all worth the experience! Thank you for your kind words once again.
@SanjibDas-ct2wr5 жыл бұрын
@@aldovanzyl-jackofalltrades8446 Thanks sir for your response. couple of queries yet again , if you be kind enough to answer me. 1. Does your Dp frzs attain -18c temp that is much required for raw meat preservation. 2. Does ice formation takes place on the other side of the pipe fixed plate which may spoil the insulation part.
@hajalimra40494 жыл бұрын
Super sir I have 300ltrs blue star deep freezer evaporator line leak ...so how many length use copper tube ,what size and capillary size and length...please mention....
@bretirwin12874 жыл бұрын
Hey Aldo, thanks for the vid. I am looking to build a portable 12v battery operated freezer with around 250litre volume. Have done some research. Could I build it like you have done here and thencover it to look more aesthetically pleasing? What compressor do you suggest? Danfoss is all the Americans talk about, but they are very pricey and maybe over rated?
@lukmonalani72892 жыл бұрын
secop, and sikelan
@aldovanzyl-jackofalltrades84462 жыл бұрын
Yes, I know a guy that did that, he covered it with chromedeck plate, looked awesome actually. Not sure what compressor to use in 12v range. Normally its calculated by the volume of gas in the pipes. So this rebuild takes very little gas because its only 30 meters and 6mm copper pipe. So a small compressor can do the job easily
@ashwinabdurahman4575 Жыл бұрын
How long was the capillary tube that u used?
@aldovanzyl-jackofalltrades8446 Жыл бұрын
I mentioned it in the description, 1.5 meters long.
@asjadalr93405 жыл бұрын
Good job
@zaidmalik7956 жыл бұрын
nice video
@aldovanzyl-jackofalltrades84466 жыл бұрын
thank you very much
@omarspenser1333 жыл бұрын
Where exactly did u put the accumulator. On the return line to the compressor or on the discharge line after capillary?
@aldovanzyl-jackofalltrades84463 жыл бұрын
I put it after the capillary, at the bottom, lowest point.
@rustyrebar96474 жыл бұрын
Nice video, but isn't a new freezer more cost effective? All that copper tubing and materials , refrigerant must have cost quite a bit of money...
@aldovanzyl-jackofalltrades84464 жыл бұрын
Hi there. Its actually cheaper fixing it this way, also it lasts a lifetime now. Less stress on compressor, cools quicker. Thanks for comment, and watching!
@ashwinabdurahman4575 Жыл бұрын
How much meters of capillary tube did u use?
@abiodunimevbore43085 ай бұрын
@@aldovanzyl-jackofalltrades8446obviously true but most times after a successful re-piping, the deep freezer tends not to be freeze downwards but half way from the top. Another observation is that once there's power outage the deep freezer defroses out immediately Any expert reasons to this and a better way of doing it properly? Will appreciate your feedback Thanks
@kareemmulla72055 жыл бұрын
Nice sir ham chest Frezer internal pipes Leak hoo aa to kyakare
@mohammedshareef78935 жыл бұрын
How many feet of cooling coil and capillary is in a 200 liter blue star deep freezer sir pls help me
@aldovanzyl-jackofalltrades84465 жыл бұрын
I would use about 25 to 30 meters
@bktv69104 жыл бұрын
Please tell me capllary length & size
@aldovanzyl-jackofalltrades84464 жыл бұрын
Capillary is 0.62 and should be around 1.2 to 1.5 meters long. If the capillary is too long cooling will take long, there is no set formula... Trail and error
@queentonrdkgobetsi68614 жыл бұрын
That's a good one there
@wafeeq7864 жыл бұрын
Hi Aldo I need your help bud ... I’m in the CPT region but need to build a freezer room to make ice ... can you assist?
@aldovanzyl-jackofalltrades84464 жыл бұрын
Hi there. What do you need me for...?
@navaspolarhvacuae12933 жыл бұрын
mr.Wafeeq i need your help - are you working in R& D ,
@gautamhalder82985 жыл бұрын
How many feet of cooling coil is in a 500 liter deep refrigerator blue star sir please help me
@aldovanzyl-jackofalltrades84465 жыл бұрын
I use very liitle pipe, that way the gas pressure is low, and compressor easily saves power, I use about 30 to 40 meters in 500L deep freeze.
@gautamhalder82985 жыл бұрын
It is used to keep the fish butter to keep fishing, then the temper must come as before, if Sir 40 fit pipe line...
@boitumeloromeo34885 жыл бұрын
Good day ,i bought a compressor at my work place ,i normally fix domestic fridges,the compressor its written LRA 31.5,wen recharging it ,wat amps must i not exceed when recharging the system?
@aldovanzyl-jackofalltrades84465 жыл бұрын
hi there, what is the size of the compressor in Horse power? and is it a R134A or R22? It sounds like it might be above 1 HP difficult to tell you how much amps, the best thing is the feel the pipe temp. The low pressure return line must be cold enough to form water vapor on the pipe
@BrotherKingV.P Жыл бұрын
When the electricity goes off it melts off quickly
@abiodunimevbore43085 ай бұрын
I have same question to ask and haven't got reasons why
@thadurimurali51423 жыл бұрын
How much cost of this total work sir please replay me.
@SUDeltaS3 жыл бұрын
great
@boitumeloromeo34886 жыл бұрын
I want to rebuild a same size deep freezer it had four pipes on condenser ,i tryed using old compresor but not wining,the compressor you used its 1/3 or 1/3+?
@aldovanzyl-jackofalltrades84466 жыл бұрын
Hi there. Yes it was a 1/3 R600A. With 1.5 meters of capillary tube. Hope it helps!
@boitumeloromeo34886 жыл бұрын
@@aldovanzyl-jackofalltrades8446 thanks a lot.
@tafajjolhaque12276 жыл бұрын
Nice video
@aldovanzyl-jackofalltrades84466 жыл бұрын
Thanks man.
@ramzanjani28064 жыл бұрын
God job
@temitoperaheem72624 жыл бұрын
What is d size of d compressor and d gas number
@kwentoc.chukwunonyelum32834 жыл бұрын
Hello Aldo, Thanks for this awesome video. I'm having some issues with my chest freezer and I'd like to get some recommendations from you. I have a 429 litres freezer which had worked for about 7 years without issues. Then one day, it stopped freezing even though the unit was on and compressor was working. I called a fridge mechanic and he said there was no refrigerant in the system due to an internal leak. He recommended that we change the piping from aluminum to copper. A few days after we did, the freezer stopped cooling again and I called him back. He checked the system and said the compressor was bad and needed to be changed. I bought a new compressor that was the exact same model with the one that went bad. I called the mechanic but he was unable to come for days. So I got another mechanic who installed the compressor and charged the system with refrigerant. But from then on only the top half of the inside of the freezer actually freezes and forms ice even at the coldest thermostat setting. The bottom half doesn't freeze, doesn't form any ice; it just stays cold. I called back the mechanic but he couldn't figure out what was wrong. He even added more refrigerant but then the freezing reduced to only the top quarter of the freezer while suction line to the compressor was freezing up and forming thick ice which later melts and floods the floor. I reverted to the first mechanic who said that the R134a refrigerant was too much so he reduced it. He then cut open the pipe just before the dryer and let out all the refrigerant and tested the system and said the system needed to be flushed as it had some dirt in it (The other mechanic didn't do this before installing the new compressor). In the process of flushing it with what he said was cooking gas, he discovered that the capillary was blocked and had to run a new one along with a new dryer. I did see quite a lot of dirt come out as he was flushing it. He then charged the system with R134a refrigerant but still, only the top half of the inside of the freezer was freezing with the bottom half only cold. He also couldn't explain what was happening. I called a third mechanic and all he did was add more refrigerant which again made the compressor suction line to freeze and the freezer to be more noisy than before. I had to reduce the refrigerant before the noise reduced and though the compression suction line doesn't freeze I still see droplets of water all across it. The three mechanics don't seem to know what could be wrong. However I have been doing extensive online research and based on my research I have a few thoughts as to what could be the reason but I want to run them through you. They are: 1. I suspect that the copper used in re-piping the inside of my freezer may have been larger in diameter than the original aluminum pipe. The mechanic said he used 3/8 Inch diameter copper pipe running them at the same length with the original aluminium that he took out. The pipe he took out looked to be kinda smaller than the one he put in. Could an increased diameter pipe make the compressor originally designed for a smaller diameter insufficient for freezing the entire system since the effective volume of the pipe the refrigerant has to go through has increased due to the increased pipe diameter thereby making the work being asked of the compressor greater than it can give? 2. If the scenario above is the case, I'm thinking of getting a compressor of higher power. The one currently installed is 1/3HP. I'm thinking of getting a 1/2Hp compressor. But then again I saw online that getting a higher rated compressor than the system was designed for would introduce a mismatch, as its pumping capacity would be too large for the capillary and the refrigerant won't flow fast enough to keep up with the compressor. Also the compressor would consume more electricity and the sunction superheat and liquid subcooling would both go up. Higher superheat and subcooling means that the compressor, the condenser, and the part of the evaporator that will now be liquid starved will all run warmer while the rest of the evaporator will be colder.. Sunction pressure could be in a vacuum (which isn't favorable) and discharge high. So please what do you think about me getting a higher power compressor? 3. I read somewhere that if there is air in the system it could cause only half of the inside to freeze. I also saw somewhere online that said if the system has air in it, only the top half of the condenser heats up the bottom of the condenser doesn't. So I checked the condenser and noticed that only the top half of the condenser warms up a bit during operation of the freezer but the bottom half doesn't. It's just at room temperature: not cool and not warm. Could it be that there's air in the system and it's preventing the bottom half of the inside of my freezer from freezing? 4. Another thing I noticed was that the new capillary that the mechanic put isn't quite as thick in diameter as the one originally installed in the freezer. Could the use of a smaller sized capillary affect the freezing and cause this half way freezing? 5. Also could a faulty or bad thermostat be the cause of only the top half of the inside of the freezer freezing? Please I'd appreciate your words of wisdom and guidance on what I could do to solve this problem once and for all. Also, I'm sorry for the long message... I just wanted to give you a full back story of my travails with this freezer. Thanks... I look forward to your reply
@BrotherKingV.P Жыл бұрын
Get a high speed compressor 1/3+ and make sure your capillary is long 2 to 2.5m .refill gas slowly
@asgunfatan66444 жыл бұрын
Im from indonesia Berapa ukuran pipa evaporator? Dan berapa u jumlah kondensornya?
@ashkumar31712 жыл бұрын
Hey Budd , Wouldn’t it be cheaper to just buy new freezer , labour and material cost , ok for hobby I guess ?
@aldovanzyl-jackofalltrades84462 жыл бұрын
Not for me it isn't. The majority of fridges I fix are my own. I would rather put pipes that are visible inside the freezer for future repairs. It's way easier that way! But thanks for watching!
@subhankarpaul27483 жыл бұрын
Thermostat here same place
@gautamhalder82985 жыл бұрын
In this way, minus twenty degrees will be tempered when the pipe starts, Deep freezer... Sir please answered me
@aldovanzyl-jackofalltrades84465 жыл бұрын
The copper pipe doesn't get tempered in sub zero conditions. I have a freezer done like this working for 5 years now. Non stop
@memami6 жыл бұрын
What is the use of accumilator?is it mandatory
@aldovanzyl-jackofalltrades84466 жыл бұрын
rimpysexydoll Hi there. The way that I was told by an old Fridge mechanic is that its very important part in a deep freezer. Helps with the liquid to gas conversion so that nothing gets stuck inside the pipes. Been working well for me. So easy to make one! Why not!
@zaidmalik7956 жыл бұрын
sir how many used condensor size lenght diamention and caplary dim.
@aldovanzyl-jackofalltrades84466 жыл бұрын
zaid malik ; I used the standard condenser tray. Didn't change that. Think its standard 4 or 5mm diameter. Capillary is 0.26 domestic size by 1.5 meters long
@zaidmalik7956 жыл бұрын
thanks alot sir
@m.sohial59652 жыл бұрын
Good
@joecitizen67555 жыл бұрын
What diameter is the orifice?
@aldovanzyl-jackofalltrades84465 жыл бұрын
0.026
@KoushikBJogi5 жыл бұрын
sir give jobs im from indian this deep freezer good work sir 250 liter deep freezer use cooper pipe m
@aldovanzyl-jackofalltrades84465 жыл бұрын
Thank you, If I understand you correctly you can use this method on any size