Reinforcement Lapping zone in columns | Basic rule for lapping length in columns | Civil Tutor

  Рет қаралды 43,647

Civil Tutor

Civil Tutor

Күн бұрын

Download our android app for job oriented courses
clpsheldon.pag... In this lecture I have discussed briefly, what should be the reinforcement lapping zone in columns and the basic rule for lapping length in columns.
quantity surveying topics compiled PDFs 👇🏻👇🏻
store.civiltuto...
SFD & BMD PDF
store.civiltuto...
2nd channel 👇🏻
/ civiltutorofficial
#bbs #civiltutor #quantitysurveying #ermuyeenmubarak #civilengineer
The standard length of reinforcement bars is 12 meters, as we all know. If the span of a structural member, such as a beam or column, needs to be increased beyond the usual length of the reinforcement bar, we must also raise the length of steel bars by adding extra reinforcement bars. If the straight bars are added end to end, there is a risk of steel sliding out of concrete, which can be avoided by overlapping the bars. The goal of overlapping is to keep the steel bars connected so that the load can be safely transferred from one steel bar to the next.
Hence the main functions of overlapping are;
 To maintain the continuity of steel
 To transfer the load safely from one bar to the next bar.
For illustration, let’s consider a column that is subjected to some lateral load. If the load is applied in Zone A, it will tend to bend the column in such a way that the maximum moment is generated at zone C. If this load is applied in zone B, both the end zones will experience a maximum bending moment in comparison to the intermediate zone. Similarly, if the load is applied in zone C the maximum moment will be generated at zone A. In all the cases, the end zones will experience maximum bending moment which means maximum tension. Therefore, it would not be safe to overlap the bars in any of the critical zones i.e, tension zones rather it should be provided in the intermediate zone where the member experiences the minimum bending moment. This is applicable to both the beams and the columns. It should be noted that the overlapping of bars should not be done at the same level inside a member, rather it should be done at alternate levels to avoid the buckling of the column.
As per IS 13920, both the critical zones lie at a distance of L/4 from their respective ends.
Note:-
 Avoid lapping in tension zone & at Beam/column/slab joint due to maximum stress.
 Top & bottom end of a column experience maximum bending moment.
 Ties should be spaced closely in the entire lapping zone

Пікірлер: 14
Мы сделали гигантские сухарики!  #большаяеда
00:44
Dad Makes Daughter Clean Up Spilled Chips #shorts
00:16
Fabiosa Stories
Рет қаралды 2,6 МЛН
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 55 МЛН
Lapping Zone in Column Explained in Detail
4:04
Engineering Academy
Рет қаралды 22 М.
Basic Rules for Lapping length in Column - Lap length in RCC Column
13:34
What is Lap Length?
5:27
Engineering Motive
Рет қаралды 101 М.
Мы сделали гигантские сухарики!  #большаяеда
00:44