I put a 12V battery in the load light part by mistake, I disconnect it and put it in its place, the battery charges but the LOAD LIGHT part no longer works, how can you help me?
@HippieHillHomestead Жыл бұрын
Make sure the load is turned on at the controller and take a meter and check the voltage at the load terminals.. If you have 12 volts minimum your controller is fine, if you don't you will have to send your controller back for repair.
@leandre4892 Жыл бұрын
@@HippieHillHomestead is work fine, thanks bro
@HippieHillHomestead Жыл бұрын
@@leandre4892 Your welcome. I am glad its works.
@badaboom-x3y4 ай бұрын
very helpful video. What I do with my set up is, I've added a two prong rocker on/off switch to one of the solar lines so I don't fry my controller. I just flick the switch when I have to disconnect the battery. It turns the solar power off or on. Works perfectly.
@HippieHillHomestead4 ай бұрын
That's a good idea. Are you worried about lighting hitting your controller?
@soloado50842 ай бұрын
Sir, thanks for taking us through solar PVs...so explanatory. Sir, I need more clarity on how the DC breakers in between the solar charge controller and the battery is connected with respect to the polarity of the breaker. Thanks
@HippieHillHomestead2 ай бұрын
The breaker is installed on the Positive wire only. The negative goes straight to the battery.
@BillySBC6 ай бұрын
Very nice video, Renogy makes a nice product. Thanks for posting this.
@HippieHillHomestead6 ай бұрын
Thanks for watching!
@Zerpersande4 ай бұрын
I REALLY like your video!!
@HippieHillHomestead3 ай бұрын
Thank you
@soloado50842 ай бұрын
I love your presentation. There is a statement you made about ensuring that the battery and solar charge controller is hooked up first before the PV panels. There is this fact that is being suggested that the mppt controller usually has a "block diode" that stop current from the battery going to the controller. So , how come there is power in the SCC if there is no current flow through the rover controller? Or , the Rover controller doesn't have a blocking diode ? I need clarity on it sir.
@HippieHillHomestead2 ай бұрын
There shouldn't be a diode between the battery and the cc. There is a diode between the cc and the solar panels. Hope this helps.
@Zerpersande4 ай бұрын
Great advice on breaker locations. Add: These breakers MUST be DC non-polarized. Well, assuming that you would like to avoid fires if the breaker trips under load. I’d add that once the proper wire size is determined, use the next larger size. Your properly sized breakers for your current will then ABSOLUTELY protect your wiring. Remember, breakers protect your wiring, not your devices.
@HippieHillHomestead3 ай бұрын
Yes they must be dc breakers. Great point Thank you
@neilrankin99459 ай бұрын
Thank you for the video. I also have the 20 amp Rover. I’m a little confused about the maximum VOC for 400 watts of solar connected in series/parallel. The manual says the Maximum VOC is 100 volts. My 4 renogy 100 watt panels are 22.3 volts x 4 which is less then 100. Does that mean I can connect 400 watts to 20 amp charge controller?
@HippieHillHomestead9 ай бұрын
Are you building a 12 or 24 volt system? If your building a 12 volt system 400 watts divided by 12 is 33.33 amps. Well over 20 amps. If your building a 24 volt system then you have to put two of your panels in series. So you would have 2 series at 24 volts. 400 divided by 24 is 16.66 amps. So if you are building a 24 volt system your 20 amp controller will work.
@eric02037310 ай бұрын
What type of solarpanel did you hook up ?WP, Voc Isc ? I am looking at the the 30Amp version and have 2x250watt panels 37.3Voc and 8.78A Isc.
@HippieHillHomestead10 ай бұрын
This should work fine for your panels if you are wiring them up parallel.
@eric02037310 ай бұрын
@@HippieHillHomestead yes Parallel and with a 24V battery bank ( 4x12v 8.5A bike batteries )
@mangeload3 ай бұрын
I have the 30a Rover. Can I get away with a larger gauge wire? Namely 5? I have some with terminals already I could use to the battery bank
@HippieHillHomestead3 ай бұрын
I don't know if 5 ga will fit. I will look when I get a chance. Other than that I see no reason you can't use 5 ga wire.
@mangeloadАй бұрын
@HippieHillHomestead I decided on 8 awg, it works perfectly
@HippieHillHomesteadАй бұрын
Good deal. I am glad to hear it is working.
@redwood195710 ай бұрын
Does that cover over the wires come off? Thanks
@HippieHillHomestead10 ай бұрын
No it doesn't but there is plenty of room for the wires.
@GhislainLacoursière Жыл бұрын
Good morning. thanks for the video. can you tell me on which icons I should program the monitor for egm batteries?.
@HippieHillHomestead Жыл бұрын
Yes you will use the first one. This will work great for your batteries.
@mikedevita555810 ай бұрын
Can the charge controller and inverter be connected and on without the PV?
@HippieHillHomestead10 ай бұрын
Technically yes. But if you don't have solar you don't need a charge controller. If you are waiting on your PV then yes hook it up it won't hurt anything.
@andreflavell345310 ай бұрын
what’s the green light mean that is attached on its own . was bright at night now dim ?
@HippieHillHomestead10 ай бұрын
Here is the link to the manual. Page 22 is the LED indicators page. www.renogy.com/template/files/Manuals/RNG-CTRL-RVR203040%20V2.0.pdf
@andreflavell345310 ай бұрын
thankyou but worked it out .the blue tooth connection
@mikedevita55587 ай бұрын
Thank you. Newbie here. I been building my system the past 6 months-money. Lol. Anyhow, the charge controller a 40amp renogy is just turned on. I left it AUTO. 12v Li batteries. Do i need a load to prevent overcharge or can i set a parameter to prevent overcharging ? No panels nor lpad nor inverter are connected just ye.
@HippieHillHomestead7 ай бұрын
You don't need a load, the charge controller will shut it off at the proper voltage.
@user-ec6zi8jn8l6 ай бұрын
Do I need the load hooked up?
@HippieHillHomestead6 ай бұрын
Only if you are running dc loads off the charge controller. If you are just charging batteries for an inverter then no you won't need to hook up the dc load terminals. If you have anymore questions please let me know. Thanks for watching.
@stephenspreckley821911 ай бұрын
I've been running a solar system, two 200 amp/hour batteries in parallel for 6 years, no fuses, no breakers and no problems, 3000 -6000watt inverter. All's well.
@HippieHillHomestead11 ай бұрын
When you don't use breakers or fuses your safety and the buildings safety is at risk. Not to mention your insurance company will not pay for any damage if a fire occurs. Breakers and fuses are cheap comparatively speaking so why not use them? I highly recommend installing some on your system. If you live in the US the NEC code requires them. Good luck and stay safe.
@stephenspreckley821911 ай бұрын
@@HippieHillHomestead You're right and I'll install them soon. Greetings from down under.
@Zerpersande4 ай бұрын
@@HippieHillHomestead Agree fully. Sure, if nothing goes wrong, you’re fine. But isn’t there some kind of ‘law’ about things going wrong? 😂😂😮😮
@jpmo8211 ай бұрын
Hi friends, my mppt rover 40a is not giving accurate battery percentage, it is propperly configured in 12v and lifepo4 battery, battery is new and mppt too, any other setting to make or help? thanks, regards.
@HippieHillHomestead11 ай бұрын
How do you know its not reading accurately? Can you give me an example please? Depending on how it is reading there could be a couple of things you can try.
@jpmo8211 ай бұрын
hi, the battery user manual have some parameters about battery porcentage, for example says 13.5v = 100% / 13.1v = 40% etc, and the mppt always thinks that the battery have 40 or 50% more available percenteage, the lifepo4 is selected and 12v system is selected, i own a power queen 12.8v 100ah, thanks@@HippieHillHomestead
@AdvantureRoad6 ай бұрын
Same issue with mine. Everything is programmed and wired correctly, but the monitor always shows 100%. Also had the issue with the pv terminals wired/labeled incorrectly.
@francoeltarolero4 ай бұрын
I have the same controller I have a 100ah renogy battery "AGM" on the controller there's no agm setting there's only USE FLD GEL SLD LIT any suggestion?
@HippieHillHomestead4 ай бұрын
shelter. The gel setting. For AGM batteries
@danielmarcomataya86329 ай бұрын
Please help me understand by describing what you're doing when making the adjustments. The owners Manuel is impossible to understand. I want to set my float voltage higher. It keeps shutting off the charging at 13.8 volts and I have 25 batteries in my battery bank. I need it to keep charging since I run my entire house 24/7
@HippieHillHomestead9 ай бұрын
13.8 volts is the float charge for most 12 volt batteries, that is why it is shutting off. Does it start back charging when your voltage drops below 13.8 volts?
@SteveJones-dr9lz5 ай бұрын
When choosing battery TYPE - - - > choose USER USER will let you step thru setting up BULK, BOOST, FLOAT & EQUALIZATION When finished leave the battery type setting on USER. *Research the BATTERY manual for the recommended manufacture's settings.
@Zerpersande4 ай бұрын
Breakers- Make sure they are non-polarized DC breakers. If a polarized breaker trips under load there is a high chance that it will catch on fire.
@HippieHillHomestead3 ай бұрын
Thanks for the comment 👍
@BlackJacketJones Жыл бұрын
Such a horrible design. I’ve had so many of these units break. There are so many easy ways to improve the design, like having lugs that connect by tightening a nut onto a bolt. Instead you stick a wire up into a hole and tighten it using these screws that are sunken into the unit. It’s just unnecessarily bad design
@HippieHillHomestead Жыл бұрын
This is the first Renogy charge controller I have used. Tell me what went wrong with the ones you have had to tear up. How long did they last before breaking? Did they hurt your batteries? Sorry for all the questions but I like to hear about real world problems with a product.Thanks for sharing your experience.
@briananderson24710 ай бұрын
We have three Rover charge controllers the 30amp, 40amp, and 100 amp. We've only had the 100 amp for a year but got the 40amp in 2020. We haven't had an issue with any of them so I'm curious what went wrong.