Replace Solenoid Valve JYZ-5 in Philips Steam Iron GC9630

  Рет қаралды 9,263

Petrus Goel

Petrus Goel

Күн бұрын

Pam air berada dalam keadaan yang baik. Apabila suis pelepasan stim ditekan, tiada stim dilepaskan. Kemungkinan suis atau solenoid valve bermasalah. Video merangkumi proses menguji solenoid valve menggunakan multimeter. Terima kasih kerana menonton.
The water pump is good. Pressing the steam release button after the beeping buzzer, but no steam released and no clicking sound from the unit. Well, probably it is the switch fault or control pressure valve (solenoid valve) fault. Video including all steps to test solenoid valve using a multimeter. Thank you for watching.

Пікірлер: 85
@kamarulazimi5151
@kamarulazimi5151 25 күн бұрын
Salam dari Cheras KL. Bagus video ni dan mudah paham. Teratur....Tahniah. dapat ilmu percuma hari ni. Saya pikir pump rosak maka beli pump. Tapi ada lain yg rosak. Nak cuba tukar solenoid valve pulak. Tq
@hasfinpaijan4268
@hasfinpaijan4268 3 ай бұрын
Respect..tukar solenoid tanpa bukak sensor boiler
@antutuclips5063
@antutuclips5063 Жыл бұрын
Trima ksih dgn ilmu yg sngat membantu.
@petrusgoel
@petrusgoel Жыл бұрын
Sama sama
@zaimi5240
@zaimi5240 Жыл бұрын
Terima kasih, nanti nk cuba
@Tenktory
@Tenktory 4 ай бұрын
I believe replacing only solenoid part (without the whole valve) would also do the trick and save a lot of time 😉
@petrusgoel
@petrusgoel 4 ай бұрын
Yes but i can’t find that internal parts online.
@Tenktory
@Tenktory 4 ай бұрын
@@petrusgoel What I meant was to disassemble new part and replace only solenoid.
@petrusgoel
@petrusgoel 4 ай бұрын
@@Tenktoryowh sorry you mean just replace the coil. Yes no problem. But since i have complete new parts that come with new valve…i choose to replace the whole set.
@Tenktory
@Tenktory 4 ай бұрын
@@petrusgoel Sure. I get it. That is just a small remark from my side. Actually I used your tutorial (thanks!) yesterday to fix my device and thought about simplifying repair when it was already finished 😅 So it is just a humble suggestion for the people who will have to do the same fix.
@hazrysiron7695
@hazrysiron7695 Жыл бұрын
Terbaik
@romarquezini
@romarquezini Жыл бұрын
Excelente explicação, obrigada
@petrusgoel
@petrusgoel Жыл бұрын
Thank you😊
@MsArmy00
@MsArmy00 9 ай бұрын
Iron steam saya jadi tak boleh off. Butang powernya boleh On, tapi tak boleh off. Jadi saya terpaksa tutup di plug utama. Saya bimbang iron steam rosak. Utk makluman saya telah cuba tukar pam sendiri. Seterika berfungsi dengan baik tapi butang off pula tak berfungsi.
@petrusgoel
@petrusgoel 9 ай бұрын
Cuba check connector yang bersambung ke suis pada PCB ...takut sambungan tidak rapat semasa pasang semula
@MsArmy00
@MsArmy00 9 ай бұрын
@@petrusgoel saya dah cuba rapatkan kabel dan akhirnya suis power kembali berfungsi dengan baik dengan hanya sekali tekan. Terima kasih banyak2 Tuan di atas segala tunjuk ajar.
@petrusgoel
@petrusgoel 9 ай бұрын
@@MsArmy00 well done!!! Terima kasih singgah youtube saya 👍🙏
@MsArmy00
@MsArmy00 8 ай бұрын
@@petrusgoel Semoga Tuan terus dapat buat video yang bermanfaat dan terus maju jaya.
@mrmsdq93
@mrmsdq93 5 ай бұрын
Tq tuan. Mcm mana kita nak tahu sama ada Water pump atau solenoid valve yg kena tukar ? Apa symptomp yg kita boleh lihat?
@petrusgoel
@petrusgoel 5 ай бұрын
Nak check pam rosak ka tidak: Ketika sejuk…Kosongkan/buang air dari tangki boiler. Lepas tu isi tangki air (tangki biru) dengan air dan ON kan stereka. Semasa ON dan pam berbunyi…perhatikan sama ada paras air dalam tangki biru berkurang. Kalau berkurang, maksudnya pam berfungsi dengan baik. Kalau tidak berkurang, pam rosak. Air tidak dipam masuk dalam tangki boiler… Kalau solenoid valve rosak, bila tidak tekan suis stim…stim dah keluar. Atau ketika tekan suis stim, tiada stim keluar walaupun ketika itu ada bunyi click. Pastikan ada air dalam boiler la ketika check solenoid bagus atau tidak. Harap membantu
@mateuszkuligowski7394
@mateuszkuligowski7394 Жыл бұрын
Hi! I've got almost the same iron (GB9620) after changing the water pump blue (power) and green (eco) lights are blinking. Do you have any solutions or ideas how to troubleschoot that problem?
@petrusgoel
@petrusgoel Жыл бұрын
Hi, sorry late reply. How is it? Is the problem solve already?
@mohdfazlinmohtar9026
@mohdfazlinmohtar9026 9 ай бұрын
Terima kasih tuan… Cuma saya terpikir, kenapa kita tidak bukak saya yg sebelah tu ( kedudukan tengah2 boiler ) senang mau pasang solenoid valve tu.. tak perlu bukak dan pasang kembali…
@petrusgoel
@petrusgoel 9 ай бұрын
oh yang minit 11:50 yakah? sebab bolt set thermocouple tu ketat....risau akan rosak thread nanti.
@mohdfazlinmohtar9026
@mohdfazlinmohtar9026 9 ай бұрын
oooooo yang tgh2 sambung dgn wayar putih tu thermocouple ke?.. baik sifu… kalau mcm tu tak ada cara lain memang kena bukak dulu unit baru valve tu… terima kasih..
@petrusgoel
@petrusgoel 9 ай бұрын
@@mohdfazlinmohtar9026 ya..itu thermocouple
@msaifulaaazhar2759
@msaifulaaazhar2759 5 ай бұрын
Nat pum tu ketat sgt tn. Tak blh buka ... Macam mana yer?
@petrusgoel
@petrusgoel 5 ай бұрын
Dah dapat buka ker?
@marnimarien
@marnimarien 23 күн бұрын
Saya dah tukar solenoid valve tp masih tak keluar steam, apa cara boleh buat lagi. Air steam banyak di decal.
@petrusgoel
@petrusgoel 22 күн бұрын
@@marnimarien pam hidup tak? Ada air masuk dalam boiler?
@marnimarien
@marnimarien 22 күн бұрын
Pam hidup, air masuk. Decal ada air panas banyak setiap kali on. Tp wap xkeuar jgk @petrusgoel ​@@petrusgoel
@petrusgoel
@petrusgoel 22 күн бұрын
@@marnimarien ok. Wap tak keluar….air ada tak masa tekan butang stim? Takut dia panas tapi tak cukup panas untuk produce steam. Satu lagi takut sumbat kat soleplate
@user-jb3id9ju3k
@user-jb3id9ju3k 7 ай бұрын
tuan, solenoid valve tu saya measure dapat dalam 2.5 kilo ohm. ok tak dapat bacaan tersebut?
@stelios_sikiotis
@stelios_sikiotis Жыл бұрын
I have problem with my gc9630! The center protective relay drop when connect my steam generator. When I was opened the case I saw the spark on the solenoid valve. Could you please tell me if this part can do this? Also if try to replace the valve must replace and the other bronze part? Thank you for your time!
@petrusgoel
@petrusgoel Жыл бұрын
may I know which part is the 'center protective relay'? The valve is usually one set. May I know what is the problem? No steam? The solenoid valve not clicking?
@stelios_sikiotis
@stelios_sikiotis Жыл бұрын
@@petrusgoel the protective relay from house power switchboard! The steam iron does not start! I saw some cracks on this part (I follow your disassemble instructions).
@petrusgoel
@petrusgoel Жыл бұрын
@@stelios_sikiotis owh...OK. So probably the coil in that solenoid valve is short between Live and Neutral. That is normal since the valve works in 'hot' operations. Try replacing the solenoid valve set. maybe for a start, If you have ohm meters, check the resistance between the 2 L-N terminals on the coil. Zero or near Zero = faulty coil.
@stelios_sikiotis
@stelios_sikiotis Жыл бұрын
@@petrusgoel on my multimeter I don't get any Ω ohms metering , just get k ohms 1. Also not continuity on L N ground. I will to replace this part. Thank you!
@petrusgoel
@petrusgoel Жыл бұрын
@@stelios_sikiotis alright….good luck.
@lukaskorjanc407
@lukaskorjanc407 Жыл бұрын
Hi! Since noone is answering me, would you happen to know what to check if steam is discharging without pressing the trigger button. If i press the button there will be more steam, but when i let it go, there will still be steam discharging from my iron. Thank you!
@petrusgoel
@petrusgoel Жыл бұрын
Alright. I just check the valve. There are two posibility. 1. The spring inside the valve getting weak….lead to weak valve closing. 2. The rubber that close the valve prbably getting hard or faulty. These 2 condition can lead to ‘leak’ steam from the boiler to the iron even when the switch is off. My suggestion, replace the valve. You can see the spring on minutes 13.00.
@lukaskorjanc407
@lukaskorjanc407 Жыл бұрын
@@petrusgoel Thanks for the quick reply!!! As a matter of fact, 5 minutes ago i dissasembled the valve, put it back, worked for about 30 seconds, then the leak started again. Will replace it with a new one. Thanks again and all the best L.
@petrusgoel
@petrusgoel Жыл бұрын
@@lukaskorjanc407 welcome…
@lukaskorjanc407
@lukaskorjanc407 Жыл бұрын
Just to let you know it was the spring. I cut a piece of wire and put it in the hole under the spring, and now the spring has more power to close the valve. Thanks again!! L.
@petrusgoel
@petrusgoel Жыл бұрын
@@lukaskorjanc407 wow that's great!!!! save $$.
@romarquezini
@romarquezini Жыл бұрын
Poderia me passar a medida da mola que mostra nos 13 minutos? Ela é de ferro ou inox? Obrigada
@petrusgoel
@petrusgoel Жыл бұрын
Diameter =3 mm . Length =18.4 mm . Material stainless steel
@buahgenuakmuda7874
@buahgenuakmuda7874 Жыл бұрын
Selamat pagi tuan. Saya punya model cg9660. Saya nampak wap air yg keluar tu kurang. Kadang2 tak nampak. 1. Water pump ok. Lepas kosongkan tank, tekan on ada air mengalir melalui lubang easy decal. 2. Buat flushing ada air keluar tapi di bahagian atas soleplate saja. 3. Bila tekan ada bunyi click mcm biasa. 4. Wayar host panas Agak2 tuan masalah apa ya?
@petrusgoel
@petrusgoel Жыл бұрын
Mungkin air yang masuk dalam boiler tak banyak. Pam ada masalah….air tak banyak/cepat masuk tangki. Kalau bunyi pam lebih kuat daripada biasa, mungkin pam ada masalah…..ada bebola dalam unit injap pam yang rosak.
@ahmadmuhaimin4880
@ahmadmuhaimin4880 Жыл бұрын
Hello boss..iron sy pump bunyi tapi air tak nak masuk dlm boiler ..tukar pump baru pn masih sama juga ..bila masuk kan air dlm boiler ikut lubang decal wap boleh keluar .apa masalahnya ya ?
@petrusgoel
@petrusgoel Жыл бұрын
Tukar pam complete set bersama hos yang masuk boiler? Kalau ya, cuba cabut hos yang masuk ke boiler. Cuba on semula dan tengok ada air keluar dari hos ka tidak….
@ZamriHusin81
@ZamriHusin81 11 ай бұрын
Tuan, nak tanya, masalah iron sy ini, bila sterika baju, wap keluar tp kelauar skali dengan air. Baju basah. Apa ya tuan masalahnya? Terima kasih atas bantuan
@petrusgoel
@petrusgoel 11 ай бұрын
1. Pam berfungsi dengan baik dan pam air dari tangki ke boiler? Kalau pam bermasalah isi boiler, stim cair boleh berlaku. 2. Adakah tuan tekan suis ketika iron sudah betul betul panas? Kalau iron belum cukup panas, stim akan cair bila kena permukaan stereka sebab stim lebih panas dari permukaan stereka. Tunggu sehingga stereka panas. Tekan butang stim beberapa kali supaya stim menolak air yang masih ada pada hos…air tu yang biasanya akan meleleh
@AzwaniRazali
@AzwaniRazali 4 ай бұрын
Sy punya iron bila on suiz,lampu on off blinking je,apa masalah ye?
@petrusgoel
@petrusgoel 3 ай бұрын
Blinking dan tiada apa apa bunyi? hanya blinking?
@mohdalifmohamad9761
@mohdalifmohamad9761 Жыл бұрын
Tuan nak tanya, iron sy bile tekan on fius box tendang... Apa masalahnya.. model gc9622
@petrusgoel
@petrusgoel Жыл бұрын
RCCB ka? Yang ada butang tekan tu..
@mohdalifmohamad9761
@mohdalifmohamad9761 Жыл бұрын
Btl tuan... Fius dekat plug x putus, tp dekat DB dia tendang
@petrusgoel
@petrusgoel Жыл бұрын
@@mohdalifmohamad9761 ada leakage to ground tu. Kena buka unit dan check. Ada banyak kemungkinan kenapa ini berlaku.
@mohdalifmohamad9761
@mohdalifmohamad9761 Жыл бұрын
Tuan boleh kasi no whatsapp
@petrusgoel
@petrusgoel Жыл бұрын
@@mohdalifmohamad9761 saya dah padam no henphone saya. Dah ambil tak?
@abrahmanmohd9945
@abrahmanmohd9945 Жыл бұрын
Salam tuan saya dah tukar PUM tapi wap keluar sedikit kenapa ya.
@petrusgoel
@petrusgoel Жыл бұрын
Pam hanya pam air dari tangki ke dalam boiler. Kalau wap ada keluar dari stereka, kemungkinan ada kebocoran dari solenoid valve. Ini jangkaan saya.. kerana kalau valve ada leak (tak tutup habis) mungkin akan ada leak. Cuba buka valve dan check mekanisma valve, takut ada bendasing yang sangkut kat valve.
@nurdzifazuradziyauddin9135
@nurdzifazuradziyauddin9135 Жыл бұрын
tuan, mcmana ya iron saya bunyi steam tapi bila iron dia keluar air dan baju jadi basah, nak repair apa ya?
@petrusgoel
@petrusgoel Жыл бұрын
Ok. Saya pernah jumpa masalah ni sebab pam rosak. Air tak banyak masuk dalam boiler menyebabkan bila steam keluar…ia bertukar jadi air bila sampai stereka
@nurdzifazuradziyauddin9135
@nurdzifazuradziyauddin9135 Жыл бұрын
@@petrusgoel terima kasih tuan. apa alat ganti yg patut saya beli.
@petrusgoel
@petrusgoel Жыл бұрын
@@nurdzifazuradziyauddin9135 sebelum tukar barang, cuba test tengok ada air dipamnmasuk dari tangkinke dalam boiler ka tidak ketika pam hidup. Keluarkan air dari boiler dulu.. biar kosong. Isi air dalam tangki. On dan lihat paras air….
@tahereh3585
@tahereh3585 Жыл бұрын
Hello, I am from Iran, can I ask a question about Auto Phillips?
@petrusgoel
@petrusgoel Жыл бұрын
Yes sir. Is it Philips Steam Iron?
@tahereh3585
@tahereh3585 Жыл бұрын
Yes
@tahereh3585
@tahereh3585 Жыл бұрын
NL9206AD-4DDrachten
@tahereh3585
@tahereh3585 Жыл бұрын
Steam comes out from under the main plate of the iron tank
@tahereh3585
@tahereh3585 Жыл бұрын
And steam also comes out of the on switch
@irfanafiq3868
@irfanafiq3868 Жыл бұрын
Tuan , sy sudah tukar valve tpi masih tk keluar apa mungkin masalahnya tuan
@petrusgoel
@petrusgoel Жыл бұрын
Ada bunyi 'click' pada valve bila suis kat stereka ditekan tak?
@irfanafiq3868
@irfanafiq3868 Жыл бұрын
Tk ada tuan
@petrusgoel
@petrusgoel Жыл бұрын
@@irfanafiq3868 sebelum tukar takda bunyi? Selepas tukar takda bunyi juga? Cuba check voltan ke coil solenoid valve ketika suis ditekan …ada voltan ka tidak?
@alansyah6443
@alansyah6443 Жыл бұрын
Tuan, macammana nak pastikan selenoid valve atau waterpump yang rosak?
@petrusgoel
@petrusgoel Жыл бұрын
Solenoid valve, akan clicking dalam unit apabila suis kat iron ditekan. Kalau takda clicking, itu tandanya solenoid valve problem. Waterpump pula akan pam air masuk ke dalam boiler apabila air kurang dalam boiler. Boleh dengar bunyi pam tu. Nak check pam, …. Masa sejuk, buka drain plug. Keluarkan semua air. Tutup balik, dan isi air dalam tangki. On semula unit, dan pam mesti hidup dan pam air masuk boiler. Boleh lihat paras air turun kalau pam bidup.
PHILIPS STEAM IRON GC9630 PUMP PROBLEM, WHY AND HOW TO SOLVE
30:29
Petrus Goel
Рет қаралды 3,5 М.
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 24 МЛН
Самое неинтересное видео
00:32
Miracle
Рет қаралды 1,2 МЛН
The Joker kisses Harley Quinn underwater!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 42 МЛН
DVLOG9: Cara nak gantikan Solinoide Valve iron Philips model GC9630
9:05
didot tukang elektronik
Рет қаралды 7 М.
Why the steam generator does not produce steam.
30:49
Ryszard Muła
Рет қаралды 55 М.
How To Repair damage to the pump used in the Philips Aqua PerfectCare steam iron
16:01
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 24 МЛН