Remember to still include 25% of your largest motor when you are done with everything! No matter how many units you have you will only count it one time. For example in this video the largest motor is from the garbage disposal which is 900 VA .... then 900 VA x .25 = 225 W . This means along with what I taught in the video you will add 225 W. This means the ending number: 33,705 + 225 = 33,930 W ... This is your answer for total VA. 25% L.M. vid: kzbin.info/www/bejne/jqKplKCud5mIoqc&t Summary and Comparison of Standard and Optional Method: kzbin.info/www/bejne/d6Kwm3t-ebhqgdk
@bobbyh62936 ай бұрын
you are helping out so much by breaking it down ! thank you
@jarodvelectric74316 ай бұрын
Glad to help! Remember to include 25% of your largest motor when you are done with all of this. Check the pinned comment for a more in depth explanation plus I will be uploading a video on it soon on my channel so look out for that.
@Brandom84Ай бұрын
Passed my load calcs for my Admin @ 90% because of your videos! Thank you
@jarodvelectric7431Ай бұрын
@Brandom84 Good job! You also passed because you studied and took it seriously. I'm really glad my videos helped!! And thank you for the feedback.
@JoeMama-gk6py6 ай бұрын
Awesome video
@jarodvelectric74316 ай бұрын
Thanks! Remember to include 25% of your largest motor when you are done with all of this. Check the pinned comment for a more in depth explanation plus I will be uploading a video on it soon on my channel so look out for that.
@relentless3835 ай бұрын
You're doing an amazing work, brother. Great explanation, and the attention to details is at another level. Thank you so much!!
@jarodvelectric74314 ай бұрын
That is very kind of you, thank you!!
@georgebradshaw46283 ай бұрын
My brother you are doing a great job 👏. Thank you keep up the great work
@jarodvelectric74313 ай бұрын
Thank you, I appreciate that!!
@Blac_Ronin3 ай бұрын
Great content young man. Mahalo
@jarodvelectric74313 ай бұрын
Thank you!
@rcg62727 ай бұрын
Thanks in advance...
@jarodvelectric74317 ай бұрын
Yes! And good luck!
@loln00bsifyАй бұрын
Hey Jarod you said in the video that you've been doing this for a while now. Do you do this for work? Because I recently began learning load calculations. And I really enjoy doing them, and I am curious about what types of jobs would have to perform L.C. as a primary responsibility. I appreciate any insight and thanks for the video!
@loln00bsifyАй бұрын
30:57
@jarodvelectric743126 күн бұрын
Yes I have been studying this for over 6 years and have years of experience on the job as well. That is a great question and I am glad you enjoy doing these because that should benefit you in life. Are you an electrician? As an electrical contractor you will need to be able to solve these to get licensed and also to know how to do your job. There could be positions where you solely do load calc but I have never heard of them ... I'm guessing the best chance at finding a position like that would be for the union. However it is good to know positions like that would usually not be for the new employees but instead reserved for those with lots of experience and years with the company.
@yasserabisaipineda97002 ай бұрын
Thank you for your video. Very informative. Question. When we’re calculating the (AC) why after multiplying 18 x 240. Why didn’t have to multiply by 125% that’s what’s getting me confused.
@jarodvelectric7431Ай бұрын
@@yasserabisaipineda9700 125% is for commercial load calculations, not residential.
@MrFortnej29 күн бұрын
Hey Jarod how does gas appliances affect load calculations?
@jarodvelectric743126 күн бұрын
Great question! Gas powered appliances still need an outlet to ignite the flame and help the electronics in the appliance work, this is known as the "power for supplemental equipment and lighting." Check out Article 210.52 (B) (2) Exception 2. This exception tells us that we can add an extra outlet to provide power for the "supplemental equipment and lighting" on gas ranges as well as gas ovens and counter-mounted cooking units. Notice that this is found in section (B) of Article 210.52. Section (B) is Small Appliances (Small Appliance Branch Circuit ... SABC) this means that this extra outlet can be added on one of the SABCs. In conclusion you do not need to add any additional load for a gas powered appliance. The circumstance where you might end up adding additional load for a gas powered appliance is if someone mentions they want it on a dedicated circuit. Since it is located in the kitchen the plugs will need to be on the SABC meaning you would count another SABC at 1500va. You might see this in real life with a customer.
@andrescientos4 ай бұрын
Maybe the mouse has an automatic garage port and lights up when it's in use (26:50 )
@heavencolumb710625 күн бұрын
Thank you Jerry. So much help . I would like to have your e-mail please.