Video Dikhne mein agar problem ho rai ho to comment karke bataye.. Kya Video wapas banana chahiye??
@hirennavadiya1473 жыл бұрын
No problem.. Ok hey.
@sudhirskamble3 жыл бұрын
please make on insta. overcurrent, tcs, lbb and autoreclouser
@helpelectricals94103 жыл бұрын
Sir jee Industries me cable Selection ke bare ma dijhaye..with current Dansity and sqmm and Amp. Or Cable try type and Selection
@rahulyadav-du9po3 жыл бұрын
Sir no problem in video. I want to know smthg more..... How is the connection of relay when we use REF for a line? and What is REF non directional stage 1 start or stage 2 start and stage 3 start
@kaifsaif1843 жыл бұрын
No sir. Great. Your explanation is awesome
@QammarabbasKhan-fe3kz Жыл бұрын
Your are great sir i am from Pakistan .Even difficult things become easy with your way explaining.
@niteshchourasia5002 жыл бұрын
It's is very good Subject sir that you clearlified in very easy way.It support us for in troubleshooting in problem
@harpreetsinghgrewal6433 жыл бұрын
Great upload. You explained really well. Next topic: How to choose the CT ratio and C value (C100, C200 etc) so the CT doesn’t saturate during a fault?
@electricalwithabhishekjoshi11 ай бұрын
Video banate hai..
@badgujarminesh6776 Жыл бұрын
Ye video dekhkar aaj muze lag raha hai interview me agar muze pucha jaye aur me definitely iska ans kar pauga and mera impression bhi positive rahega..
@sayonarasheikh69742 жыл бұрын
Sir apane bahot achha bataya hai.....I m also electrical engineer....but college me jitana nahi samjha usase kahi jyada ap ne achha smjhaya hai....thank you very much sir🙏🙏🙏 for your efforts....
@electricalwithabhishekjoshi8 ай бұрын
Most welcome..
@muhammadalimughal3488Ай бұрын
Bilkul samajh agayi bohat shukria .
@debdutmajumder99392 жыл бұрын
Today I read this scheme from the book of JB Gupta, I hardly understood the working principle, but after watching this video, it's crystal clear. Thank you
@electricalwithabhishekjoshi11 ай бұрын
Most welcome...
@सिर्फसत्य10 ай бұрын
Bahut badhiya bhaai..mai b bahut pareshan tha..Books me thoda sa topic de rakha tha but ye to bahut bada aur important topic ha...
@NarayanVyasElectrical2 жыл бұрын
Very well explained. Clearly understood function of stabilising resistance. Thanks!
@MuhammedIrfanMuhammedRamzan6 күн бұрын
Well done, bro. I like your presentation very much.
@karanshah4712 жыл бұрын
Very important for field engineers! Very well explained. One more point can be added like why in CT secondary current flows opposite concept of P1-P2 ~ S1-S2..so that if it gets reversed in wiring that fault can also be found.
@sitarampanda50402 жыл бұрын
reverse the polarity then will be a fault creat automatically
@karansbhagat5 ай бұрын
You are amazing tutor such a nicely explained. Thank you so much.
@avantikav132 жыл бұрын
Very clera and sound as well as informative, Thanks . Please make a detailed video on transform oil testing and action incase of oil contain danger gas, furan test analysis and action.
@banajkumarsahu66762 ай бұрын
Sir,You are explained very well
@muhammadkashif2356 Жыл бұрын
bohat he Alaaa! Allah pak apko mazeed kameabi dy ameen
@electricalwithabhishekjoshi Жыл бұрын
Shukriya..
@ANILKUMAR-gu4yc Жыл бұрын
Gr8 sir 👍👍🙏, aaj clear ho gaya REF, differential protection ka bi video bunaya
@MuhammadIsmail-t7q10 ай бұрын
Good Explanation and I understand it very well. Good way of teaching. Love from Pakistan.
@Crickettherepy2 жыл бұрын
Awasome brother I learnt clearly from this video video is very helpfull thanks for your video
@gaurav_143292 жыл бұрын
kya gazab explain kiya hai🙌🙌🙌
@jotyrmoychakraborty22842 жыл бұрын
Thank you so much. Your explanation is so much great.
@electricalwithabhishekjoshi2 жыл бұрын
Most welcome...
@shailshanshah3 жыл бұрын
Sir you have explained beautifully. Thanks for sparing time & making such informative video . I have few queries, request to address them . 1. Why this REF protection only use in transformer having capacity equivalent or more than 2.5 MVA? 2. REF protection Relay will be installed in primary side of transformer or secondary side ? Once again thank you very much for this video . 🙏🙏
@sitarampanda50402 жыл бұрын
Ref is primary side also primery and secondary side
@sivatejakulukuri9612 Жыл бұрын
Super sir excellent concept given very understandable thanks for making this video sir🙏
@ajitchauhan57533 жыл бұрын
One of the best vedio Abhishek Ji.
@aydanahir9360 Жыл бұрын
Thank you Sir I understand all your explanation. Very nice video Sir
@Adarshvrm233 жыл бұрын
in such busy schedule sir you have attented my doubt after cmnt love u sirrrrrrr
@electricalwithabhishekjoshi3 жыл бұрын
🙏🙏
@wajahatsohail2435 Жыл бұрын
Thanks for such an amazing explanation Sir
@prakhar5star4 ай бұрын
Great explanation sir...thank you so much
@deepakghorpade88963 жыл бұрын
Perfectly getting clear concept sir.....
@electricaljagat71592 жыл бұрын
Mere solar plant me 5mva TRAFO ka REF tripping relay operate hota hai jab outside area (substation) me earth fault hota hai.. restricted area k bahar k faul pe operate nahi hona chahiye na... Stabilizing resister work nahi kar raha kya? Please suggest more....
@vikashvishvakarma4653 жыл бұрын
नमस्कार सर् आप बहुत अच्छा से समझाते हैं और समझ में भी आता है सर् एक request थी आप से ड्राइंग कैसे read किया जाता है ओ भी एक part by part सर् समझाए आप की बहुत कृपा होगी हम सब पर
@electricalwithabhishekjoshi3 жыл бұрын
Vikash, Drawing wali Playlist dekho.
@AlishaKhan-ld2qt2 жыл бұрын
Bahut ache se samjhaya sir
@SatishYadav-pk5eh8 ай бұрын
Dear sir , I'm a big fan of your teaching style ....
@electricalwithabhishekjoshi8 ай бұрын
Thank you Satish..
@theworldbysinu3 жыл бұрын
Full package for electrical.,. excellent sir
@electricalwithabhishekjoshi3 жыл бұрын
Thank you...
@abhishekroy18463 жыл бұрын
1)Why nct is not getting saturated but phase CTs are getting saturated due to high fault current? 2) What is the zone of protection of lvref and hvref in a 33/11kv substation?
@MuhammadWaqas-nb6pe Жыл бұрын
Due to NGR
@mohdmustafa822 жыл бұрын
Sir.. Kya Restricted earth fault relay ko transformer ke delta connection ke liye use nhi kar sakte...
@maheshchinvagol7299 Жыл бұрын
Sir. I would like to know the ceiling fan rotates in anticlock wise direction. And blades are skewed in such a way that air comes downward. If it make direction clockwise blade will be made skewed opposite of anticlockwise . Is it work. Why you make direction only in anticlock why not clockwise. But tables fans were in clock wise. Please explain sir. I am awaiting
@abinashsahu2192Ай бұрын
Very important information sir Thank you
@mkmkm44082 жыл бұрын
Abhishekji, beautifully explained. Can you just add, what will be the scenario if the transformer winding is delta connected?How the CTs will be connected?
@pankajsinghbora8803 жыл бұрын
Sirji.....Earthing and neutral ka RYB k sath sequence kya hota h.... Transmission nd distribution line m
@viewjankari3 жыл бұрын
Jab resistriced zone ke andar fault hota hai, tab bhi current I2 lowest resistance path kyun nahi karta? Kya tab stabilizing resistance series mein nahi hota hai?
@rahamgul17023 жыл бұрын
yes same question arised in my mind
@khankakar0121 Жыл бұрын
Thankx buht kuch sekha ap say sir
@electricalwithabhishekjoshi Жыл бұрын
Most welcome.. 👍
@subhashelect2 жыл бұрын
Very Good Explain..very nicely ..I have one queation Line CT and Neutral CT SHOULD BE ONE POINT EARTH OR SEPERATE EARTH..
@sanandachhatria64652 жыл бұрын
so simple teaching sir I could easily understand
@souvikduttaroy2241Ай бұрын
Best explanation ever ❤🎉
@NandlalSingh-l4z11 ай бұрын
Sir aapki samjhane ka yahi tarika chahta tha ❤🙏
@Sailor1864 Жыл бұрын
Very Nice Explain And More Knowledgebal vedio Sir 👍👍
@सिर्फसत्य10 ай бұрын
Mera ek question hai ki Books me likha ki differential relay ko jab transformer (delta star) k protection me lagate h to CT delta side star me aur star side delta me connect hota h..but actually Maine power transformer (delta star) me dekha h ki star side CT ko bhi star connected kar rakha h...aisa kyun karte h? Aur kon sahi h books ya practically.
@RohitKumar-kr3du Жыл бұрын
Without any fault occurence, what is the direction of secondary current in the line CT
@pankajvaja12992 жыл бұрын
Very helpful for understanding sir
@pratishpatil12182 жыл бұрын
Great knowledge sir really apriciate
@sajidmahmood7351 Жыл бұрын
Very Nice, and Breif explanation..Thanks
@electricalwithabhishekjoshi Жыл бұрын
Most welcome Sajid..
@jagdeepsingh-kf5qp5 ай бұрын
Sir please yeh baat clear krna k CT k secondary me current direction opposite kyo hota hai kis law k according. Aur ye sarbhi secondary core me hota hai??
@bhuwneshwarsahu23903 жыл бұрын
Bahut achhe se samajh me aaya sir 🙏🙏
@electricalwithabhishekjoshi3 жыл бұрын
Thank you Bhuwneshwar..
@praveenulloju96622 жыл бұрын
Really Explained very well Thankyou
@prasun_mandal975 ай бұрын
Explained very well sir. 😊
@ajitroy19903 жыл бұрын
Beautiful explained.mai Aaj tak samajh nahi pay tha ye concept but now I feel confident.lekin sir ek question puchhna Chahta hu .apne kaha jab fault hota hai to fault current k opposite CT ka secondary current flow karta hai. Kya normal condition me jab sab kuchh sahi chal raha ho to CT k secondary ka current flow kiss direction me rehta hai.pls sir ye bataiye.kyunki Maine book me padha tha normal condition me CT k secondary aur primary me 90 degree ka difference hota hai thora confused hu.pls clear kar dijiye sir
@chapsytapsy2 жыл бұрын
in normal condition also CT secondary current is 180 degree to primary current. Lenz law
@sureshkarunakaran8500 Жыл бұрын
Excellent explanation sir.thank you
@manubtek4 ай бұрын
Well explained. Thank you
@faridkhan-mf5xg3 жыл бұрын
minimum kitna load ho phr hamy cT lagani hoge.kia hm single phase meter per CT laga sakty hai?sir plz guide kare
@subhashelect2 жыл бұрын
Very Good Explanation ..pls let us know the CT Sceondary Grounding will se sepearately line ct secondary and neutral CTSeconday seperate Grounding..
@ElectricalEngineer1062 жыл бұрын
Amazing video, your videos are very helpful in my internship ❤️❤️❤️
@electricalwithabhishekjoshi2 жыл бұрын
Thank you...
@sitarampanda50402 жыл бұрын
@@electricalwithabhishekjoshi sir please help .mere ko ek book chahiye jisme sab kuchh hoga please bataye
@electricalwithabhishekjoshi2 жыл бұрын
Kaunse topic pe book chahiye?
@sitarampanda50402 жыл бұрын
@@electricalwithabhishekjoshi testing commissioning and relay
@nabanitakundu85063 жыл бұрын
Sir beautifully explained. Could u pls tell us about high impedance and low impedance REF
@RajeshRaj-rp5ht2 жыл бұрын
Wonderful explanation good knowledge
@rajeshjadhav002 жыл бұрын
Very informative video ... 👌🙏
@simplifyelectricity6048 ай бұрын
Sir nice explanation. Dear sir i think stabilizing resistance will be in opposite side of the relay.
@TheMasterShow-TMS6 ай бұрын
Amazing Explanation 🎉
@naushadmohammad2784 Жыл бұрын
Iske jagah pe efr use kr sakte hain kya with 4 ct
@abdulroufashraf40652 жыл бұрын
thanks dear , you have explained well
@electricalwithabhishekjoshi2 жыл бұрын
Most welcome...
@anupsingh89363 жыл бұрын
Sir...you are doing very great job for us in simple language to make us understand.. I hav bit confusion if fault occur outside then current will also come through stabling resistor in relay or will follow other path to NCT...kindly clear my doubt..🙏
@GhulamMurtaza-xg5hc2 жыл бұрын
Thanks sir from Pakistan
@electricalwithabhishekjoshi2 жыл бұрын
Most welcome..
@tanyadutta28712 жыл бұрын
Sir when fault occur outside the restricted area, u said magnitude r same so resultant current is zero but stability resister affect one side of magnitude ,then might be chance of energies of ref. (Plz clear sir) Also make a video on when to use metrosil? And its calculation ?
@sayantanpaul47662 жыл бұрын
Precisely explained 👌👌
@naushadmohammad2784 Жыл бұрын
Sir CT Ka p1 P2 direction kidhar hoga or CT agar 2500A Hain to CT ratio ,class,VA kon SA rakhna padega.
@yagnikpansuriya1267 Жыл бұрын
Bahut badhiya!!!
@spps18922 жыл бұрын
Very nicely explained
@roopeshyadavendra99932 жыл бұрын
Sir synchronising pe bi video dalo with drawing ki kaise konsi pt use hoti hai or kaise bus ka selection hotha hai
@007mohiuddin2 жыл бұрын
Verywell explained.....
@ranjankumarmahala8133 жыл бұрын
Very good explanation, and one more request that pls classify internal and external faults and describe it's protections.
@sivakrishna-rq8rq2 жыл бұрын
Good explanation, great bro
@salimmalek99922 жыл бұрын
Excellent lucture Sir very good
@electricalwithabhishekjoshi2 жыл бұрын
Thank you...
@amitprasad25882 жыл бұрын
Superb sir... Ecxelent
@tradersadda33459 ай бұрын
Sir ,in normal condition 3 phase ct seconary current also flow which can flow through the earth fault meater and trip the circuit
@hpvide3 ай бұрын
Very well explained
@vikrambhuva2526 Жыл бұрын
Sir jub line ct saturate ho jata he tab current ct se hote huye resistance ke through relay me kyo nahi jata jab ki pehle case me neglect hote samay to vaha se flow ho rha tha ?
@anshraj78622 жыл бұрын
AMAZING.... PLEASE MAKE VIDEO ON CT SATURATION........
@shafiullah81283 жыл бұрын
Super video as usual
@moridivyesh94443 жыл бұрын
Extremely superb sir
@anandbhoj4714 Жыл бұрын
Ye current ki direction CT ki secondary me opposite ku hoti hai.. primary ke direction ke comparison me
@somikbandyopadhyay59202 жыл бұрын
Greatly explained
@sachchidanandpandey1881 Жыл бұрын
Very good explanation
@Indiabhanu Жыл бұрын
Great explanation
@bharatbaldha17593 ай бұрын
Very good explain
@किरणपवार-च9श3 жыл бұрын
Great explained sir...
@yog68012 жыл бұрын
Hi Abhishek Ji Plz make a video on Back Up Impedance protection of Alternator
@electricalwithabhishekjoshi2 жыл бұрын
Okay Yogendra..
@yog68012 жыл бұрын
@@electricalwithabhishekjoshi Thanks for your quick response Sir Your explanation is very impressive Please make a video on Alternator testing like PD Test Elcid test Tan delta test And on Complete protection of Alternator...
@DavidMARs16Ай бұрын
sir ap ki videos best hy.. but es video mai samaj ni araha k fault kesay ground say ho kar ja raha hy neutral mai. or CT mai secondary current kaha say araha hy
@MrRaj-un3zy3 жыл бұрын
Sir TB ke bareme kuchh bataye aur, iske jyese aur device kebareme bhi bataye...
@nachiketsuratia91793 жыл бұрын
thanks sir very well explained.
@viveksingh39893 жыл бұрын
Sir ji In case of high currents of external faults, only phase CT is getting saturated, not Neutral CT. Why so? And in case of internal earth faults, why neutral ct is not getting saturated, tgough the cirrent intensity lies similar to case of external faults... Please help sir ji
@electricalwithabhishekjoshi3 жыл бұрын
Saturation of CT is a rare event bcoz we use PS class CT.
@snnmurtay79258 ай бұрын
In normal working condition what is the current flow direction in current transformer