Returning To The System With High Head Pressures to Replace Liquid Line!

  Рет қаралды 26,907

HVAC GUY

HVAC GUY

Күн бұрын

Пікірлер: 141
@ThePeavey23
@ThePeavey23 Жыл бұрын
So glad I am done with that work almost 20 years in the industry doing this daily and I’m done !!! Thank you lord!!
@tomwalker9184
@tomwalker9184 Жыл бұрын
Well if you made 6 figure + income like Curtis doe's it much nicer. Than working for the man.
@kens.3729
@kens.3729 Жыл бұрын
Sweet looking White Van, Curtis. GOD knows you’re a Hard Worker and Don’t Stop until the Job is Completed and the Customer is Satisfied. Thanks! 👍🙏
@kens.3729
@kens.3729 Жыл бұрын
Thank GOD for Repairmen like you that definitely know what they’re doing. 👍 Unfortunately there aren’t enough young people getting into a number of Trades.🙏
@jthonn
@jthonn Жыл бұрын
Man I agree, these young folks don't want to work (there are exceptions). They have a Ruud awakening coming.
@craigbraswell4269
@craigbraswell4269 Жыл бұрын
Yup, for every 5 hvac techs retiring, there are only 2 to replace them.
@tekjunkie28
@tekjunkie28 Жыл бұрын
@@craigbraswell4269 Good Maybe yalls pay will go up and then I'll join the trade.
@itsallaboutASL
@itsallaboutASL Жыл бұрын
Congrats on the new van! Please make a video of your build out!!!
@Guillotines_For_Globalists
@Guillotines_For_Globalists Жыл бұрын
Mice dryer exhaust in the garage. Top notch!
@georgeramirez5225
@georgeramirez5225 Жыл бұрын
Good news finally a Van to work from makes it easier on jobs.Good job
@YukonHawk1
@YukonHawk1 Жыл бұрын
Really well done
@robalexander7348
@robalexander7348 Жыл бұрын
Nicely done Curtis, if only there were more dedicated tradesmen like yourself 👍 All the best with setting up your new van 👍
@jdere31760
@jdere31760 Жыл бұрын
I hope you get prospective clients from them just watching your HVAC videos which show how much of a great diagnostician and hard worker you are! It's impressive...
@HVACGUY
@HVACGUY Жыл бұрын
I hope so too!
@thathvacguy
@thathvacguy Жыл бұрын
You are one hard working dude, reminds me of my father. I’m glad u got ya work van! shes beautiful. Bless God u and yours 💪🏽
@throttlebottle5906
@throttlebottle5906 Жыл бұрын
the dryer vent into the garage is super lol. I guess it would heat the garage in cool weather(re-lol). I could see doing that with an electric dryer in colder climates and a drafty garage (if not the humidity would be bad and mold everything/structure) watching more, I bet the dryer used to vent underground through the green SDR pipe and elbow sticking up behind the condenser! It surely clogged with lint/leaking water in and breaking clothes dryers(blowing thermal fuses and other), so someone's hack fix was dumping it into the garage!
@earlestes8649
@earlestes8649 Жыл бұрын
The moisture would not be good
@kens.3729
@kens.3729 Жыл бұрын
That’s Not Snow in Georgia but instead it’s Ice in Curtis’ (HVAC GUY) World. 😬👍
@billsimpson604
@billsimpson604 Жыл бұрын
That white van will stay nice and cool. Guard your refrigerant supply. A few days ago I heard on the police scanner that thieves broke into somewhere and stole refrigerant! You would think they would have just run that copper line into the wall, instead of putting it under the slab. That is how mine was done. It goes into the brick, into the attic, and comes down into the hall closet evaporator coil and heat strip resistance money burner heater.
@Chainsaw600
@Chainsaw600 Жыл бұрын
360, 361; whatever it takes. Couldn’t resist. Nice job!
@MRXDS1989
@MRXDS1989 Жыл бұрын
That's love the condenser being 10 ft away.
@stephenbullock1443
@stephenbullock1443 Жыл бұрын
Great work curtis
@Sctronic209
@Sctronic209 Жыл бұрын
I would of and often do braze the line first then cut in the filter dryer. Great job on that one.
@LuisC202
@LuisC202 Жыл бұрын
God Bless man. Keep the great videos coming
@jamessanchez4411
@jamessanchez4411 Жыл бұрын
I had to pull a 3\8 line from a basement to 2 story and attic on my on Bosch Change out from a train that was 1\4 it went better than I expected I think tape had dried out through years holding the lines together and I had a helper feeding the line from the basement .
@douglaskahane141
@douglaskahane141 Жыл бұрын
N2 tank looks great..
@michaelhediger9088
@michaelhediger9088 Жыл бұрын
Nothing ever goes right. Good job
@fernandoprieto2865
@fernandoprieto2865 Жыл бұрын
Oh wow, what a great observation.
@ervingoss5442
@ervingoss5442 Жыл бұрын
Nice looking van. I bet it will be even better when you get all of your supplies in it.
@hinspect
@hinspect Жыл бұрын
Wow, that house was assembled by the lowest bidder it looks like! That dryer vent in the garage is unacceptable but not as bad as venting next to a condenser. That will be hard to modify. Great job on the heat pump repair, thanks for the Video!😉
@yellowdeer7163
@yellowdeer7163 Жыл бұрын
So glad to see you got a van.
@ishalljr
@ishalljr Жыл бұрын
Nice pull! You had it right the first time thanks be to GOD, not luck!
@billybrown1979
@billybrown1979 Жыл бұрын
like the video. good work. nice van. i see you find your knee pad. i see they got shark bite out for cooper tubing. is your GREE HVAC working good.be bless and safe.we are going to have a polar system coming down so get ready.
@Eddy63
@Eddy63 Жыл бұрын
Watch Steve Lav's vids on restocking his new truck ... He's a one man wreckin' crew ... Good vid , thx for sharing ...
@michaelmartin5582
@michaelmartin5582 Жыл бұрын
Excellent job Curtis. Would love to be out there working, but due to health issues had to retire. Really enjoy watching your videos.
@franciscotejeda1461
@franciscotejeda1461 Жыл бұрын
Like always doing an excellent job Mr Curtis and have a good day. 😃
@topher8634
@topher8634 Жыл бұрын
All that ice on the coil sure helped with the pump down no doubt. 410 systems usually buck and open the IPR.
@THESNAKE8
@THESNAKE8 Жыл бұрын
Heat probably didn’t kill the seal, i find those tend to leak just from being used after installation even if you’re not using a torch near them
@Chris-ru3ri
@Chris-ru3ri Жыл бұрын
I always remove my gauges and core before brazing. Plus wrap the valve.
@catwrangler1613
@catwrangler1613 Жыл бұрын
Love ur new ride!
@gregmiracle9560
@gregmiracle9560 Жыл бұрын
Looks like refrigerant shot out of liquid line when you first started to close it off so I don't believe you caused the leak from heat I believe it was existing! But great job getting all run and done! 👍👍
@DanO181919
@DanO181919 Жыл бұрын
Did I miss something but how did you pump it down without any gauges hooked up.
@David-lf2ne
@David-lf2ne Жыл бұрын
His hand is calibrated for temperature and pressure. It’s the new upgrade along with new van.
@thesilentonevictor
@thesilentonevictor Жыл бұрын
Good video tech
@andrewschultz678
@andrewschultz678 Жыл бұрын
Epic job man very well done!
@jthonn
@jthonn Жыл бұрын
Glad to see you are getting the van back, will be nice and easier to work out of. Do you think once up on a time they had a smaller unit that used a smaller line or was it just incorrect from the start? Reason I ask is my unit is old, so when I do the change out, I may need to run a new line set. It won't be easy on mine. I guess check and see what the new unit calls for and go from there. I just answered my own question. Nice job Curtis.
@michaelharris1653
@michaelharris1653 Жыл бұрын
I commented earlier about the temperature sensor. I should have added, when forcing defrost.
@officerkrupke4966
@officerkrupke4966 Жыл бұрын
He said in video that he changed out the defrost board and sensor.
@bryanharayda1975
@bryanharayda1975 Жыл бұрын
Did anyone else notice the double trap in the drain line? Trap under stand and second trap when drain goes under slab and back up outside. Also I may have missed something but how were you able to pump that unit down into the condenser in heat mode? I see it now, it was a Rheem/Ruud, reversing valve is energized in heating, and you pulled the O wire off the defrost board. This is why I shouldn’t watch these videos at 3 am lol
@qyouwilber5734
@qyouwilber5734 Жыл бұрын
I have soldered electronic components in the past and if you did not want to over heat them you would use an alligator clip as a heat sink. You could have put the valve cap back on or get a large fitting with the same threads as the cap and put that on the valve to draw the heat away. Heat travels just like electricity and the bigger the wire the more current/heat it will carry away. I don't know if that would make a big difference with a torch in such a small distance but it couldn't hurt.
@cal3178
@cal3178 Жыл бұрын
I worked in electronics repair years ago. Now own a hvac company. I use my soldering skills to repair many control boards that develop cracked solder joints. Its very common on certain brands molex plugs. A soldering iron gets to around 700 degrees max. Oxyacetylene brazing can get between 6000 and 7000 degrees.
@qyouwilber5734
@qyouwilber5734 Жыл бұрын
@@cal3178 copper melts at 1900 degrees. If you are brazing at 6000 degrees it probably won't work. I looked up brazing temps and they say 850 to 1400 degrees. You can also solder the connections like a plumber would if the code allows. He might be able to use a large spring clamp with the rubber removed to help draw the heat from the valve.
@keepthinking2666
@keepthinking2666 Жыл бұрын
For the leak of the service on I don't know if you noticed it when you went to Valve it off for a pump down you could see a little poof of liquid freon spray out more than I could just a bad seal once you open the valve it should seal it and the same goes with the cap unless you price it in to replace it and the freon which is a lot more as you know
@chrissipple1018
@chrissipple1018 Жыл бұрын
Just a note when ever you are pumping down a system always install gauges so you know what pressures you have. And never pump any kind of a compressor into a vacuum. With out gauges you never know if its in a positive or in a vacuum. Im sure that I'm wrong. Just do it the right way.
@David-lf2ne
@David-lf2ne Жыл бұрын
I noticed that too. I guess his hand is calibrated for temperature and pressure.
@chrissipple1018
@chrissipple1018 Жыл бұрын
@@David-lf2ne This guy is fun to watch
@kens.3729
@kens.3729 Жыл бұрын
I suppose they used a Hose Clamp on the Old Copper line for Unknown reasons. 🤔
@keepthinking2666
@keepthinking2666 Жыл бұрын
I came across something similar last night at I guess I could call him a friend's house or more like an acquaintance where it was a quarter inch liquid line where somebody had replaced the unit about 20 years ago and instead of pulling the line said they left it the quarter inch and at the ends about a foot before the unit they changed it to 3/8
@Ridehighfxdb
@Ridehighfxdb Жыл бұрын
Why wouldn’t you clean the bubbles and cool gel out the valve before you put the cap on with leak lock?
@richardambrose3156
@richardambrose3156 Жыл бұрын
looks like the way folks here do it... change an old R-22 system out and put in a R-410 and try to use Old Line Set...
@HiddenResolve
@HiddenResolve Жыл бұрын
Curious why they went under the slab with it when it looks like the lineset could have just wrapped around behind that water treatment and HWT and out the sidewall.
@jthonn
@jthonn Жыл бұрын
That would have been too easy.
@c21meister
@c21meister Жыл бұрын
Wooowww congrats with the new van! Can you sell me your old one?
@FG-tg9uk
@FG-tg9uk Жыл бұрын
If anyone can turn Chicken Poop into Chicken Soup, it's you. Well done.
@viper22304
@viper22304 Жыл бұрын
Thanks for sharing the video. Great work. Question: did you backseat the liquid line before or after the adding the seal lock? thanks again
@michaelharris1653
@michaelharris1653 Жыл бұрын
Should you not jump the temperature sensor?
@mikerodriguez1455
@mikerodriguez1455 Жыл бұрын
What’s the charge for the replacement of the 1/4 “ liquid line , I’m very interested in how much you charge for such a difficult job!!! 😱
@chuckquinn8026
@chuckquinn8026 Жыл бұрын
Gotta say 99% of techs, especially working alone, would have just drilled thru the wall vs pulling under the slab 🤷‍♂️ Congrats on the new van. Did the insurance company total your van?
@HVACGUY
@HVACGUY Жыл бұрын
No, but they are paying for repairs.
@Bass.Player
@Bass.Player Жыл бұрын
I always wondered why those access caps don't have some sort of seal in them.
@matthewclemons1574
@matthewclemons1574 Жыл бұрын
Its supposed to cut into the valve seat.
@craigbraswell4269
@craigbraswell4269 Жыл бұрын
Sometimes they have a rubber gasket in them, I've seen gaskets on certain goodman/Amana outdoor units.
@channelcatchaser9426
@channelcatchaser9426 Жыл бұрын
No guage on the pull back? Probably more the drier than line size...but probably line size is important as well. Good job
@Hvac-dude
@Hvac-dude Жыл бұрын
Hey Curtis this is a very odd question I should already know but how exactly do u pump down a condensor unit well ac
@d3adp94
@d3adp94 Жыл бұрын
Service valves on condenser. Front or back seat them to open/close
@jrtakesthesky27
@jrtakesthesky27 Жыл бұрын
Close your high side service valve by front seating it and keep your low side open. Run the system in cooling (aka just press the contactor down). You usually want to monitor the low side pressure but in this video's case the condenser is frozen so there is low to no risk of over heating the compressor windings. You wait for the Low side to get just under 0 psig, you want to lose as little refrigerant as possible. Remember the compressor needs refrigerant to cool it down so don't run it forever in this vacuumed state. Then you can close the low side service valve and you now have a condenser pump down.
@Hvac-dude
@Hvac-dude Жыл бұрын
@@jrtakesthesky27 thanku !!
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
I was betting the old line was ok even at 5/16
@cal3178
@cal3178 Жыл бұрын
That’s what I’m thinking. How old was that system? It’s worked for that long
@jimharmon3404
@jimharmon3404 Жыл бұрын
Great job Curtis. I don't know hardly diddly about HVAC. Finally I just have to ask... what's in that dryer you always replace? Can you open a "pre-enjoyed" old one so we can see whats inside? How do you know when they need replacement?
@chrisischill2693
@chrisischill2693 Жыл бұрын
Anytime system is opened.
@HVACGUY
@HVACGUY Жыл бұрын
Desiccant beads, or block, and fibrous filters on the ends
@officerkrupke4966
@officerkrupke4966 Жыл бұрын
@@HVACGUY Had a new install and techs didnt install filter drier. I called owner of company and he came out and said it was factory installed and pointed at the compressor muffler. Choose your hvac company carefully, and the cheapest price isnt always your best option.
@dalescott838
@dalescott838 Жыл бұрын
When you sucked down the system you should have your gages connected. That way you can see what you are doing.
@throttlebottle5906
@throttlebottle5906 Жыл бұрын
35:48 failed leaking o-ring, go figure! they either leak with age or once you touch them(turn to close/service) pretty much they're useless except for being new shipping from factory with pre-charge.
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
I think I would have run the new line exposed
@bobgallo3775
@bobgallo3775 Жыл бұрын
Not all repairs go nice and smooth
@bobrumpf2576
@bobrumpf2576 Жыл бұрын
great job on that one ,do you ream that pipe after you cut it?
@EverythingHVACR
@EverythingHVACR Жыл бұрын
I didn't see the previous video. An undersized liquid line was causing high pressure?
@HVACGUY
@HVACGUY Жыл бұрын
Yes
@jthonn
@jthonn Жыл бұрын
Yes
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
In first video the pressure was fine in cool mode but high in heat mode. I would think the pressure would be high in both modes if the liquid line itself was too small
@EverythingHVACR
@EverythingHVACR Жыл бұрын
@James FITZSIMMONS Well, I thought about this, and restrictions or small liquid lines won't usually cause high pressure, that's why I asked. But your condenser coil gets smaller in heat mode, so it could affect you more so than in cooling mode.
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
@@EverythingHVACR that’s one reason some of the early Rheem/ Rudd had charge adjusters in the indoor coils to kinda equal out the charge between heat an cool
@keepthinking2666
@keepthinking2666 Жыл бұрын
But quick question did you tell him to cut the bushes around that unit to give it more air flow as well and did you test the defrost switch thermostat
@Brand14BJ
@Brand14BJ Жыл бұрын
I believe he replaced it.
@benaskew1301
@benaskew1301 Жыл бұрын
I love watching your videos but it kills me when you don't ream those cuts.
@NoorRefrigerationsystem
@NoorRefrigerationsystem Жыл бұрын
Hello sir .. How are You
@patricspointofview7188
@patricspointofview7188 Жыл бұрын
When you change the liquid line, you don't need to evacuate the whole system? Where does the freon go?
@HVACGUY
@HVACGUY Жыл бұрын
Pumped into condenser
@97Napkins
@97Napkins Жыл бұрын
I prob woulda gave up after not pulling and just ran it through the wall and to the unit
@bamatractor
@bamatractor Жыл бұрын
I can tell you feel like crap today!
@mattbilodeau2433
@mattbilodeau2433 Жыл бұрын
I got scared for you when it wouldn't pull outside. Do you ever use wet wrag paste for valves?
@billyk5107
@billyk5107 Жыл бұрын
I wouldn’t of cut out the liquid line dryer I would’ve un sweated it so that you could use the fitting again on the service valve
@gordonpotts753
@gordonpotts753 11 ай бұрын
Jesus was on ur side on this one
@jima3129
@jima3129 Жыл бұрын
Hole saw and s length of 1 inch pvc?
@elijahgoodman3140
@elijahgoodman3140 Жыл бұрын
Just curious, what did your head pressure settle out at? By the way, excellent troubleshooting!
@HVACGUY
@HVACGUY Жыл бұрын
Around 310 when I left
@earlestes8649
@earlestes8649 Жыл бұрын
@@HVACGUY what is it supposed to be? Ty
@EvesterGaming
@EvesterGaming Жыл бұрын
@@earlestes8649 All depends on outdoor and indoor temp for pressures
@earlestes8649
@earlestes8649 Жыл бұрын
@@EvesterGaming I repair appliances and furnaces and AC except for Freon anything electrical or plumbing. I’m handicapped but I wanted to take classes for it but they told me that with my history they wouldn’t pay for anything but a office job. So I took accounting and passed with b average . But couldn’t see me behind a desk, I love wiring houses and putting in meter bases etc, I’ve fixed my AC and furnace several times over the last 30 years it was installed in 92
@karellodewijks4971
@karellodewijks4971 Жыл бұрын
👍👍😊😊
@billyk5107
@billyk5107 Жыл бұрын
I wouldn’t pull it out I would blow through it and see if it’s got a restriction with nitrogen if it goes through it super easy leave it
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
Curtis just curious did you check the drier like blowing your mouth through it just to see if it was restricted I know you didn’t have any frost on it but maybe your subcooling was too high at that time to show frost etc
@HVACGUY
@HVACGUY Жыл бұрын
No, i didnt
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
@@HVACGUY thanks Curtis for getting back to me
@MrDookieDan
@MrDookieDan Жыл бұрын
where was the knee pad?
@HVACGUY
@HVACGUY Жыл бұрын
This call may be where I left it
@purtis99
@purtis99 Жыл бұрын
Oscillating saw
@TomLawson05
@TomLawson05 Жыл бұрын
This unit has suction line drier could it be stopped up?
@HVACGUY
@HVACGUY Жыл бұрын
I think that’s called a charge compensator. That’s not a suction filter - it’s not on true suction.m
@richardvisco6370
@richardvisco6370 3 ай бұрын
Ohm out defrost sensor see if its closed while ice is on coil
@richardvisco6370
@richardvisco6370 3 ай бұрын
Hope it's a biflow drier
@matthewclemons1574
@matthewclemons1574 Жыл бұрын
As a reefer tech leak lock is garbage, best bet honestly is monster tape(very little) and nylog. Or just nylog and tighten it down.
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
Common liquid line restrictions include clogged filter-driers or metering device restrictions. Many techs think that refrigerant will exit the compressor and back up against the source of the restriction, which would raise the head pressure. However, that’s not true. Our diagnostic sheet shows that liquid line restrictions cause low suction pressure and normal to low head pressure, not high head pressure. That’s because the compressor requires refrigerant of a specific density to pump refrigerant into the high side of the system; when the suction pressure is low, the compressor can’t move as much pressurized refrigerant to the high side, so a liquid line restriction doesn’t have a huge impact on the head pressure when you have reduced amounts of high-pressure refrigerant in the liquid line in the first place. Some thought experiments that can help you grapple with that idea include thinking about refrigerant in a tank and the pump down cycle (used to prevent refrigerant migration). Note: don’t pump down a microchannel condenser! However, when you have a restriction, its location has a significant effect on the head pressure. The amount of charge also matters, as overcharged systems are more likely to have a significant impact on the head pressure (raising it and causing hydrostatic pressure buildup within the system). The most common liquid line restrictions are clogged filter-driers, metering device inlet screens, a kinked liquid line, or a TXV with an empty bulb. These very rarely cause high head for more than a short period of time. The most common causes of high head pressure include high load, overcharge, and poor heat rejection (such as from dirty or obstructed condensers). One response to “Do Line
@richardvisco6370
@richardvisco6370 3 ай бұрын
Bad defrost sensor
@davidgearardo1788
@davidgearardo1788 Жыл бұрын
damn you braze fast , god my weak point is brazing, been working on it but damn all the pro press guys need take note, brazing can be faster
@Mapdotgolf
@Mapdotgolf Жыл бұрын
Bad sensor for defrost
@adrianfelix1592
@adrianfelix1592 Жыл бұрын
Is this your own business?
@gregwalker731
@gregwalker731 7 ай бұрын
Worked in the business for a lot of years. This is one of the things that aggravated me the worst, poor installation. This unit never had a proper installation or start up done. The customer now has to pay someone to fix the installation that they have already paid for once. My second pet peeve is installation without considering serviceability.
@robertwood9628
@robertwood9628 Жыл бұрын
I know you have many young followers that think everything you do is great and I truly hate to be a downer but...OK I'm not going to list the things I would correct after all. Just shaking my head.
@rugged1987
@rugged1987 Жыл бұрын
How can I even take you serious if you cant even use a pair of channel locks the correct way 🤔
@andrewszaniszlo9243
@andrewszaniszlo9243 Жыл бұрын
I was telling my hvac class that you are a very smart mechanic, but you do not protect your health, and over time it will kill you.please wear a mask when in dangerous atmospheres and don't breath in refrigerant.
@timrob0420
@timrob0420 Жыл бұрын
Did you look in manual? Some of those older rheems took 1/4in liquid line….
Reviving an Older Rheem Gas Pack! #hvacguy #hvaclife
47:18
HVAC GUY
Рет қаралды 14 М.
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 40 МЛН
Creative Justice at the Checkout: Bananas and Eggs Showdown #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 14 МЛН
Do Line Restrictions Cause High Head?
7:31
HVAC School
Рет қаралды 82 М.
Full Compressor Install In 15 Minutes!
12:37
Dee Does HVAC
Рет қаралды 1,2 М.
This Was a TERRIBLE Install….Until Now
16:29
Quality HVACR
Рет қаралды 35 М.
LENNOX PACKAGE UNIT HIGH HEAD PRESSURE
19:12
HVACR VIDEOS
Рет қаралды 50 М.
How Many Calls In ONE Day Is Too Much?? | HVAC Life
14:32
Quality HVACR
Рет қаралды 188 М.