Review: Pt 1 Fluke 115 TRMS Multimeter

  Рет қаралды 149,241

mjlorton

mjlorton

Күн бұрын

Пікірлер: 84
@mjlorton
@mjlorton 11 жыл бұрын
It measures Amps down to three places...but no further...you can measure 1mA...but not part of a mA as it has no mA or uA selection.
@mjlorton
@mjlorton 11 жыл бұрын
Yup...quite a few folks have been caught out by the Fluke 11x series and not realised they are limited in terms of electronics use. A really nice meter (about $55-65) for bench electronics is the UNI-T UT61E..but not good for high energy work.
@mjlorton
@mjlorton 11 жыл бұрын
Will do after the full review of the U1232A.
@mjlorton
@mjlorton 11 жыл бұрын
Ok...I'm sure you've mentioned this before...I need to make a note and check myself. Thanks for the post.
@Nermash
@Nermash 11 жыл бұрын
mV range on 115 is DC+AC coupled, and pushing the secondary button switches it to DC only:) It is a bit odd, but if you look at the symbol in white marking above the mV sign, you will see straight line on top of curly line, indicating DC and AC. Still lot more intuitive than mV DC range on 287 that is also AC+DC coupled... And I got TL75 leads as standard with my 115, not the silicone TL71.
@alchemy1
@alchemy1 4 жыл бұрын
How come you can't zero out the ohm reading? Sometimes mine reads a lot higher than 0.1 ohms when I touch the two leads.
@electgpl
@electgpl 8 жыл бұрын
Hi, how are you?, what to choose between Fluke115 and Agilent u1232a? regards from Argentina
@MrMikesMondoVideo
@MrMikesMondoVideo 11 жыл бұрын
That was my understanding. In the rare event I need microamps - and I don't know that I ever did - I have another meter capable. 1 milliamp resolution will be fine. Thank you for your response and confirming my understanding. Still trying for the flea-bay deal...
@clems6989
@clems6989 3 жыл бұрын
Now closer to 200 bucks!
@dntlss
@dntlss 6 жыл бұрын
I have one of these meters and i love it (no i dont work for Fluke,lol) but i use it mainly for testing things on my cars etc, I'm not a electronics person measuring the origins of life inside a circuit panel but just your average DIY person, it must be cheap overseas or in other parts of the world but it wasn't cheap for me and i shop around,its sturdy and very well made and it has a nice weight to it,not really sure on the display issue some people have had,the one i have is crystal clear and i love the blue light, i dont use it that much so maybe if i did it would mess up on me,lol, but so far so good.
@AlainHubert
@AlainHubert 8 жыл бұрын
Be aware that the test probes and leads shown in this review are not those that come with this meter. What Fluke gives you are cheapish probes, with vinyl leads not high quality silicone. Moreover, be aware that in order to be able to read the display, the meter has to be at eye level or higher. If you tilt the meter down towards you (looking at it from above) you can't see anything on the display. I should know, I just bought the Fluke 115 brand new.
@lliaolsen728
@lliaolsen728 8 жыл бұрын
I noticed that as well. My display all but disappears at an angle and the leads are hard plastic.
@jefferyanderson1889
@jefferyanderson1889 7 жыл бұрын
have one too AK-WA best of all!
@KeenanTims
@KeenanTims 11 жыл бұрын
Maybe the LEAD indication is just a warning and the position of the leads has no bearing on it? It seems to be displayed any time you enter or leave current measurement mode. It's odd that you saw about the same reading in AC as DC on the mV range. I guess it doesn't block DC as a meter should? Or maybe it's specified as only a DC+AC measurement? A bit odd.
@LifeBeginsAtForty
@LifeBeginsAtForty 2 жыл бұрын
My fluke 115 always having problem with resistance option. When i put both probes together, hardly get 0.0 and the reading is between 0.3 to 0.5, sometimes goes up to 0.6. Why?
@Caesar1959XL
@Caesar1959XL 11 жыл бұрын
Marti. TrueRMS of this meter works up for 1kHz, while UNI-T UT71A /E goes up to 100kHz. That is making a real difference...
@refrigerationengineer1335
@refrigerationengineer1335 11 жыл бұрын
Can you review the fluke 116
@lazerpete3594
@lazerpete3594 7 жыл бұрын
perhaps the reason it doesn't have ma is because the digits go into tenths (instead of like 10.1 it goes into 10.01 so in the 10 amp scale is would show ma
@kylekelly4648
@kylekelly4648 10 жыл бұрын
Great video! I'm convinced in buying this meter. I would have liked to see how quick it measures capacitors but still very informative. Thank you.
@testbenchtech
@testbenchtech 11 жыл бұрын
I will wait to see part 2, not having low current settings is disappointing, but most electricians would never need to look at three or six places to the right of the decimal any way. 0.5% accuracy,D.C. and 1.0 % accuracy, A.C. is disappointing too, but,again most electricians can live with as well. Electricians enjoy the ruggedness of the meter. Drop it, kick it, toss it in the back of your truck, or put it in your tool bag with other tool betting it to death and it keeps working.
@kaybhee6
@kaybhee6 3 жыл бұрын
for us, DC block filter, values around... 1.2 Mega ohm carbon type, 1/2 watt, and 1.5 micro farad polyester film , seem to work... with our equipment.... your values might differ, according to your gravitational and biosymbiotic resurgences...etc..
@musarichesmabuyangwa3706
@musarichesmabuyangwa3706 7 жыл бұрын
i cant see the variable resistor and signal gen ...why dont you show those connections?
@sepertude
@sepertude 11 жыл бұрын
Why dont you test beeper speed in diode mode? I usually use diode range when looking for shorted semiconductors and if diode beeper is slow responding for shorts, it gets to my nerves ::) Also with good diodes a meter should short beep once, this also help to speed up the troubleshooting process. Another point would be that meter has to have over 2.00V diode range othervise it wont be able to detect many leaky transistors or diodes. I have seenmany time whereleaky transistor shows around 2.2V
@JojoCruzSolano
@JojoCruzSolano 10 ай бұрын
Sir what is the diffence of fluke 115 to fluke 115C same face.
@themesh8886
@themesh8886 7 жыл бұрын
Common Fluke... no Touch Hold? Im trying to replace an older 73III and this meter is perfect for me except for that missing feature.
@uh6537
@uh6537 7 жыл бұрын
Your information about the amp measurement is misleading. You are right that the meter does not have an mA setting but it autorange and can measure down to 0.1 mA AC/DC. You also not have a mV setting for DC - only for AC - but you still can measure down to 0.1mV AC/DC also.
@billytran1442
@billytran1442 5 жыл бұрын
What fluke model has micro farad capacitance, temperature and milli amp?
@protikbanerjee9323
@protikbanerjee9323 4 жыл бұрын
Hi can you tell me how to fix Loff problem in Fluke115. When ever i switch on it displays Loff and nothing works. There is NO service center near to my location.
@lmarloe
@lmarloe 6 жыл бұрын
I've got the same display contrast issue on 117 and 113, both are brand new
@moleman1961
@moleman1961 8 жыл бұрын
Is it normal that the readout jumps about in DC mode?
@rapsod1911
@rapsod1911 11 жыл бұрын
Can you connect all your dmms in parallel to frequency generator and try their bandwidth? You put 1V sin. rms and watch when they show more than 1% error.
@stearman456
@stearman456 10 жыл бұрын
Is there any way to increase the volume of the continuity beeper on the Fluke 115? I realize I'm old and deaf, etc, but it is what it is. First class unit, though - rock solid, reliable and accurate. Glad I spent the money.
@GhostOfJulesVerne
@GhostOfJulesVerne 10 жыл бұрын
I love my 115. I use it for basic electronics diagnostics/repair, as well as for household wiring work. I don't really ever need to measure microamps, however. The 115 can't do that.
@kaybhee6
@kaybhee6 3 жыл бұрын
mV range does not show ac only,,, mv range is dc coupled,,, so we experiment to make dc block circuit ,,, note fluke 101 does measure mv ac only... that one does not have dc mv
@ImranKhan-ye9pn
@ImranKhan-ye9pn 5 жыл бұрын
How to check board shortage, I have mobile phone Need to check minor and major shortage.
@schachat01
@schachat01 9 жыл бұрын
Hi Martin - how would you compare the Fluke 115 to the Mastech MS8250c? I can purchase a hardly used Fluke 115 for R1000 and a brand new MS8250C for R1369. Thanks Arnold
@kaybhee6
@kaybhee6 3 жыл бұрын
mV range on 115 is DC+AC coupled, yes,,, why no one makes three settings//// true ac only mv ,,,,, dc plus ac mv ,,,,,, and dc mv,,, why
@luffykun5019
@luffykun5019 4 жыл бұрын
How this troubleshooting " beep " in indicator ... I am very down guys ?
@adolfhilter
@adolfhilter 8 жыл бұрын
why is it at AC, the reading shows 0.000? Wouldn't it be 0.001 according to the chart on the right?
@diyelectronics5375
@diyelectronics5375 4 жыл бұрын
question? why we need bar graph indicator in DMM what's the porpuse? Because for me the most inportant view in DMM is Numbers and accurate reading while voltage test or other.
@MrMikesMondoVideo
@MrMikesMondoVideo 11 жыл бұрын
I'm considering purchasing this meter. You state this is no mA range. Fluke's specs state: Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A So the mA resolution is there. Am I missing something?
@gsuburban
@gsuburban 9 жыл бұрын
I agree the display needs to have better design so the face of the meter doesn't have to be directly facing the user to get a clean sharp look at the read out. Other than that, this meter does what it is was designed to.
@kiiikoooPT
@kiiikoooPT 5 жыл бұрын
I'm starting to learn about electronics and how to repair stuff, my first sucessefull repair was an old pc monitor, it had 2 blown up capacitors and i just changed them and it works now... now i have 2 LG tvs, one has color stripes on it, is an lcd tv, and the other i got it from the garbage outside my house, was in the rain for about 1 week and then i bring her in to see what it does if it works or not I was kind of scared to even turn it on since it was in the rain for few days, but for my surprise, it didnt drop my electricity and it works, but has a weird noise in the speakers and the image looks like is a bit washed away... im in the process of cleaning all the boards and components carefully and then I go see if is there anything I can do with it, or at least it will serve a a nice training piece since the boards and the tv itselfs are huge, is a Plasma 107 cm (42 pouces) HD TV from LG as well Since I started watching videos on youtube for tv repairs, I found someone saying that this multimeter is really good, so I got it from amazon for around 100€, do you think it is good enough just for tv, pc, radios, and small electronic stuff? That thing you said about not mesuring mA is something that will make me get stuck some day? do you even need that for basic electronic repairs? I dont have to much money, so I cant get another one, hopefully it will serve me well for a whille until I fell good enough to start repairing friends stuff and actually make some money ;)
@JuniorLima_sjc
@JuniorLima_sjc 10 жыл бұрын
Hello friend, between that Fluke 115 and Agilent U1232A which you recommend?
@yossishi221
@yossishi221 4 жыл бұрын
hi i order fluke 115 from amazon usa not chinese and the continuing test is with small delays not like yours at all!!!! i try to replace the cable for new and also fluke but still has small delay possible that fluke made worse model?????? thanks yossi
@steveclark..
@steveclark.. 8 жыл бұрын
I'd like it to have a proper 'Hold' button/function too, when I'm working on a car and can't actually see the screen. Is there a cheap meter that has this function?
@AlainHubert
@AlainHubert 8 жыл бұрын
You can have a "proper" hold function by using the Min/Max feature (and look at the maximum value only).
@steveclark..
@steveclark.. 8 жыл бұрын
None of my meters have a Min/Max button. Lol
@AlainHubert
@AlainHubert 8 жыл бұрын
The Fluke 115 does... ;-)
@hardergamer
@hardergamer 7 жыл бұрын
But please take your Uni T's apart before using them! and you will never use it when you see how its made!
@josephxuereb1289
@josephxuereb1289 7 жыл бұрын
where to buy
@DanFrederiksen
@DanFrederiksen 11 жыл бұрын
The UT61E is an obvious compare but something like a Vichy VC99 at 33$ could also be an interesting comparison and could do a review in itself. Dave Jones once tested it and dissed it a lot because it triggered his irrational anti chinese prejudice but if you actually look at the measurements in his video it shows it was the most accurate of all the meters in the shootout and I think the cheapest so should have won. But he placed it last. I pointed it out to him and he banned me :)
@AnkitGupta-re4tp
@AnkitGupta-re4tp 5 жыл бұрын
how should i measure the current in uA with this meter?
@kiiikoooPT
@kiiikoooPT 5 жыл бұрын
go to the 6th selection, right before A HZ and press the yellow/orange button to aply the second function ;)
@jonathancotner7040
@jonathancotner7040 4 жыл бұрын
1 milliamp is .001 amps. It can measure milliamps, but not microamps.
@kaybhee6
@kaybhee6 3 жыл бұрын
we tested... ac amps down to 0.025 amps works.... dc amps down to 0.005 amps works..... all from about 40 hz to over 2khz.. using sine
@nareshck1344
@nareshck1344 Жыл бұрын
Price plz?
@deivakumarkumar4857
@deivakumarkumar4857 2 жыл бұрын
What really means 'COUNTS'? (2000, 6000) How it is needed for any MM?
@Prince-uv8sx
@Prince-uv8sx 4 жыл бұрын
I have fluke 115 true RMS multimeter nice but it has not showing current in current mode I think internal fuse problem
@megalodonscortex7578
@megalodonscortex7578 6 жыл бұрын
Why does it keep saying OL on my fluke 115 when past the ohm setting?
@downeastoutdoors8713
@downeastoutdoors8713 4 жыл бұрын
On the ohm setting your checking resistance so when u go to ohms and have nothing connected its considered no resistance. Someone else can comment on this but i believe thats correct
@schachat01
@schachat01 9 жыл бұрын
Excellent review.
@JJ-rs6qt
@JJ-rs6qt 6 жыл бұрын
schachat01 .
@hgyfghf
@hgyfghf 10 жыл бұрын
I just got one for 78$. Was that a good purchase? It's for my father who wont really care about milli/micro amps. He has a Fluke 23 that's fading display is unfortunately not worth replacing...
@Winterreise189
@Winterreise189 10 жыл бұрын
Yes, list price for these is 180-211$ depending on America or Canada.
@Mahesh-Budha-Magar
@Mahesh-Budha-Magar 11 жыл бұрын
can you tell me the range and maximum voltage and how is it adjusted on it?? please reply asap thanks in advance :)
@AReResearch
@AReResearch 11 жыл бұрын
The maximum voltage range is 600V, others are 60V and 6V (autoranging on both AC and DC volts). The RANGE button manually toggles between the three ranges if you wish to select the range manually. The mV range is fixed at 600mV. I actually prefer the little, rugged 117 for the odd jobs in and around the house to my 87V which I use on the workbench for electronics only. The 117 has the very handy AutoV-LoZ mode I use all the time and, as mentioned in the video, the very good continuity tester. These are the two functions to get 90% of the jobs done. Still, I don't quite trust the VoltAlert of the 117 and always double-check to stay safe. So the 115 certainly is a great electrician's meter to rely on if you don't want to spend the extra buck for a 117. If you're into (micro-)electronics and digital work, that's the wrong meter.
@kaybhee6
@kaybhee6 3 жыл бұрын
ONLY for the Ac Mv setting...do try the following... seems you can get wide frequency range only for mv ac setting... stick in a sine wave signal, down to 5 mvac seems ok... and vary frequency from 10 Hz upto and over 15KHz.. IF you have DC offset also , you might need to make a DC block filter.... for us, this overly expensive basic meter is now, semi - worthwhile...
@chrishoesing5455
@chrishoesing5455 9 ай бұрын
Think a used one of these would be worth $100 in 2024?
@nilsunderseer2157
@nilsunderseer2157 Жыл бұрын
As everybody know the price is not high, it is quite standard average price for a certified iso norm calibrated multimeter. You cannot compare that to the price of not certified ones in private use area where it doesn't matter that much if your metering is 99.9% garanteed exact. A contruction company or any other project where a client needs your proof that this metering is exact would loose a lot of money if the results are not correct causing damage and the client will sue you.
@kaybhee6
@kaybhee6 3 жыл бұрын
for much less than 1 microfarad,,, one has to fiddle w range button upon power on
@Jin-Ro
@Jin-Ro 5 жыл бұрын
Always seemed pretty lame to me that Flukes can only Diode test to 2v (some flukes go higher), whereas almost any budget brand can diode test to 3.1v, which is way more useful for electronics use. As you exampled in your video, you may need another m/meter to test diodes if you have a fluke.
@rakeshgohil9241
@rakeshgohil9241 3 жыл бұрын
Hi sir, I'm Rakesh gohil, from india, Sir i want to buy meco 108b+ or fluke 115, I'm a electronic technician (tv repairs), please guide me to buy which one is good for me, by price and durability, Thank you.
@joejoseph83
@joejoseph83 8 жыл бұрын
Name the circuit used by the uploader for testing the dmm
@yossishi221
@yossishi221 4 жыл бұрын
hi i want to buy the fluke 115 for check all size of capacitors i see al your videos so do fluke have better model then this 115? thanks yossi
@evgevg9
@evgevg9 10 жыл бұрын
Thank you Martin 115 the best.Like!
@Orrymain1186
@Orrymain1186 10 жыл бұрын
I may have gotten a lemon but this was my first experience and first impressions are what count, what a complete let down.
@TranTek
@TranTek Жыл бұрын
Not my 115 they come with crappy stiff test leads
@akshatkushwah7175
@akshatkushwah7175 5 жыл бұрын
Nice
@mikeadler434
@mikeadler434 10 ай бұрын
👍👍
@Orrymain1186
@Orrymain1186 10 жыл бұрын
I'm returning my fluke 115 for a refund I purchased my first fluke no less than 72 hours ago. I was testing the amp draw on a bilge pump my meter reads nothing the circuit remains open all other functions seem to be working proper, however. My $6.99 meter out performs this 130 dollar unit. My first and last fluke. I will avoid this brand
@DanFrederiksen
@DanFrederiksen 11 жыл бұрын
You still don't compare to other meters : )
@arenetasatrec4939
@arenetasatrec4939 4 ай бұрын
One of not many nice revies and explanations.
Review: Pt 2 Fluke 115 TRMS Multimeter
20:58
mjlorton
Рет қаралды 43 М.
EEVblog #60 - Fluke 117 Multimeter Review and Teardown
20:08
EEVblog
Рет қаралды 309 М.
Who is More Stupid? #tiktok #sigmagirl #funny
0:27
CRAZY GREAPA
Рет қаралды 10 МЛН
진짜✅ 아님 가짜❌???
0:21
승비니 Seungbini
Рет қаралды 10 МЛН
Review: Fluke 17B, Chinese and New International version
44:16
Demonstrating the Fluke 115 Digital Multimeter - Mahwah Campus
13:41
Lincoln Tech eLearning Library
Рет қаралды 50 М.
Review: Mid Range / Priced Multimeter Shootout / Buyers Guide
37:35
Review: Pt 2 - Fluke 107 Palm-sized Digital Multimeter
15:54
mjlorton
Рет қаралды 33 М.
3 Ways to Check Capacitors in Circuit with Meters & Testers
14:48
TampaTec
Рет қаралды 1,7 МЛН
Review: Pt 1 - Fluke 107 Palm-sized Digital Multimeter
25:57
mjlorton
Рет қаралды 137 М.
UNI-T UTG962E 60MHz Arbitrary Waveform Generator Review
48:31
mjlorton
Рет қаралды 4,2 М.
Multimeter review / buyers guide: Fluke 87V / Fluke 87-5 Review
46:20