We are modifying the existing Clockwise (CW) rotation RGP series Gear Pump to Counter-Clockwise (CCW) rotation. As shown in the video is the modification process.
Пікірлер: 8
@s.t.perera85445 жыл бұрын
Good
@abdelhamidhammadi90692 жыл бұрын
Monsieur Hydrolicien s v p est ce que toutes les pompes de ce genre de modèle sont réversibles
@bat2ball.comofficials8622 жыл бұрын
wow
@neilharvey35719 жыл бұрын
You put the rear bearing housing back the same way , so the grooves for lubrication are now on the high pressure side , see 1.06 in your vid and 3.55 . you put it back to original way . ?????
@moghost9 жыл бұрын
Neil Harvey Hi.. we put it back in the original way. So the groove and the inlet outlet port are still in the same position. We only switch the shaft bearing position and reversed the mounting plate. So please noted that after the switching, if you still mount on the same place.. the inlet and outlet position will be totally reversed too. Before 0:19, After 4:19. Check on the mounting plate.