Great video for anyone who wants to tackle a Riello Burner, The only things i wish to comment on is the use of the multi-meter was set to Auto so some of the commentary readings provided were incorrect, so just be aware, when testing the Photo-resistor, the Ohms value will go down when there is more light and the readings for the Solenoid/Coil are different. For testing pins 1-2 expect in the region of 1.4 Kilo-Ohms and for pins 2-8 it is just 1.4 ohms. Many thanks, certainly helped me out!
@lewiskemp81688 жыл бұрын
Hi Steven I am an oil engineer from Scotland and I love watching your video's, It's just lately I came across them and am going through them all. I have been in the oil service and repair game for 40 years but I am learning a lot of tricks from you keep up the good work Louis.
@johnerway72555 жыл бұрын
Steve your series are super, great job and many thanks for your sharing the high skill you have mastered.
@derosa5046 жыл бұрын
Thanks , a troubleshooting flowchart brought me to a point where it said buy a new controller" for $80" which is not the end of the world, but it would have been money thrown away. after watching your video, i checked terminals 1&2 for 1400ohms which led to the coil $10. Thanks for posting :)
@trankt541553 жыл бұрын
How do you know if the control panel is still working?
@vitalcomputing629810 жыл бұрын
Hi Steven, Just want to say a big thanks. I found your videos very helpful.. By comparing the startup up of your Riello to mine, I was able to establish that the motor was not starting when it should... Given that the motor did start some of the time, I suspected the capacitor.. Pulled it out altogether and it measured almost 1 ohm ESR and only 0.94uF capacitance... Changed the cap yesterday, crossed my fingers and the motor has been starting every time since.. :-)
@stevenlavimoniere10 жыл бұрын
Vital Computing looks like you had a bad run cap .the uf will be on the side of the run cap most are 15 uf but depends on what burner you have
@johnrmce Жыл бұрын
Hello I have a nuway nol 5 burner I have changed the oil pump nozzle control box and base control box and I can get the boiler started only if I switch it on and off a few times also when the thermostat cycles it won't restart unless I switch it on and off a few times I also changed the solenoid cable thanks I have learned a lot from your youtube channel
@MyLeafy110 жыл бұрын
when you least expect it. excellent review! i got my notes now. i always change the obvious part but your diagnostics make my note pad for quick checks thanks! my riello manual filed away.
@stevenlavimoniere10 жыл бұрын
dino vistroni good luck with them
@hancecrawford3 жыл бұрын
Very interesting Steve and thanks for sharing how is wee Miss Molly lovely charming little dog :)
@Hammer7572 ай бұрын
Thank you for creating this series Steve. Riello's documentation is kind of sketchy and this series fills in a lot of the gaps.
@trankt541554 жыл бұрын
Thanks for the video. How do you check the transformer to see if it is still working? Thanks.
@klewis6853 жыл бұрын
I’ve literally just learnt to carry out these checks today, good video mate 👍
@CHIBA280CRV6 жыл бұрын
Fantastic explanation thanks . I am looking to install a new boiler myself in my home and I have Burnham / Beckkett oil and hit water unit , with 2 zones. Would you recommend me purchasing a Riello boiler and burner ? Just would like to install an excellent boiler and would like your opinion on it., and if so which one ?
@nyrynbrett37982 жыл бұрын
Hi steve english fan here like your vids just wondered if u can put me in the right direction been trying to get hold of the Riello oil handbook over here that u use for refrence but seem to run into brickwall over here is their somewhere i can buy it from usa
@trankt541553 жыл бұрын
But how do you check the control box to see if the electronic transformer is working or not? And during this checking when the motor is running, wouldn't the oil pump also run and spray out oil?
@robloxian777 Жыл бұрын
I'm only getting 8.6 volts at 3-7, motor. Which part would cause that?
@staszekbroszkiewicz29082 жыл бұрын
What did you want to say about Riell burner? I found nothing what help me in work with this burner
@TheRobWay1 Жыл бұрын
Is there lockout alarm on these ? There is a terminal “X” between N and L. How is this used ?
@dlipter3 жыл бұрын
Steve You explained the CAD reading backwards! Your meter measures 7,000 ohms for low room light and 300 ohms for bright lamp light. The CAD reads high resistance for low light conditions and low resistance for bright light conditions.
@arneyjeff11 жыл бұрын
Thanks as always your videos have made me a better tech.
@stevenlavimoniere11 жыл бұрын
thanks jeff
@antonybrady23456 жыл бұрын
Hi Steven thanks for info on my mums Riello 40,,,still playing her up man..changed the cad cell still not fireing is it the selonoiad ?
@calvinnewcastle58993 жыл бұрын
I have a oil to propane conversation, can I got a switching relay from manufacturer, it's going on a veiszmen boiler for Heating. Is there anything else I require?
@thepallasbull8 жыл бұрын
Thank you for this very detailed video , I have learnt a lot .Thanks
@stevenlavimoniere8 жыл бұрын
+Patrick Harte good luck
@irishguy2000074 жыл бұрын
Has the ignition coil on this controler got two primarys? It has four wires entering the high voltage transformer and two outputs to the electrodes. Has it two primary windings? I was expecting two imput wires and two output connections to the electrodes.
@trankt541553 жыл бұрын
And how do you check to see if the control box with the electronic transformer is working?
@haakon060310 жыл бұрын
Hello. I have a Gulliver Blu burner that has started to run intermittently. It runs for 3 secs and pause for about 12 secs. The water temp does not go above 45 C. On the display it says Error 50-4 and 51-4. Any idea what the problem might be=
@amitsinhmarsarpanch71534 жыл бұрын
Hi sir , am from India I am a burner user , I want know about the reillo oil burner GW model
@mmack32865 жыл бұрын
Hi Steven do you get different kind of riello rbl oil pumps?
@Supanova705 жыл бұрын
Crazy issue with my F5 .When motor starts it shortclcles rough 4 seconds for about 5 times then runs fine. Never locks out. filter /screen electrodes nozlle and control were replaced already. Is the motor on it`s way out possibly or cap? Tstat is calling. going use this test method tonight.
@webbac84914 жыл бұрын
Had a similar problem with a Riello fitted with an air intake fitted on the cover. Without the intake fitted, the burner operated smoothly but when the intake was put back on the cover, it would occasionally short cycle. The air intake was not obstructed. I then found that due to the positions of the flue terminal and air intake cowl positioned near to some bushes, the bushes were not allowing the flue gases to escape to the atmosphere easily. As a result, the air intake was occasionally ingesting some of the flue gases which consequently caused a very brief starvation of air during the combustion process. The bushes were removed and the problem was eliminated.
@MegaRadio9011 жыл бұрын
Very interesting. I'm a wiring and load freak. I like to see these thing's Steven pretty cool!!
@stevenlavimoniere11 жыл бұрын
thanks mike
@ricardoleslie98112 жыл бұрын
So, what if it read 1.41Ω between 2 & 8, would it be bad? Serious question...
@JohnMullee Жыл бұрын
Not bad. Coils fail by fusing to zero ohms, or breaking to infinity ohms ('not reading anything'). So 1.3 or "something like that" is probably fine
@ricardoleslie9811 Жыл бұрын
@@JohnMullee Thanks!
@ryanskinsale379 жыл бұрын
Hey Steve, very useful videos thanks. I have an older Riello 40 G3, I have replace solenoid,photocell and nozzle recently, the burner runs fine for 10mins or so then cuts out, it tries to start but fails , the restart button does nothing then. Any idea what I should be looking at ?
@stevenlavimoniere9 жыл бұрын
+Clan Ryan have you checked the oil flow???? and pump screen?? sounds like you might have a oil problem ,it hard to say over a email unless i am there testing stuff .and running it hard to say whats going on .
@cillianryan48779 жыл бұрын
+steven lavimoniere Hi Steve, I did take off the pump filter and clean it recently and also replaced the shutoff valve to oil tank. the tank is also lowish on oil so perhaps it isn't pulling it in properly
@stevenlavimoniere9 жыл бұрын
you might have a blocked oil line
@nightcrawler6695 жыл бұрын
I've often wondered, is there a way to do a test on the control box for the spark? When diagnosing, how would you know if you have a weak or no spark?
@trankt541553 жыл бұрын
I asked that question to assess the transformer but no one answered. Have you found out how to test the control panel to see if the electronic transformer is still working?
@JohnMullee Жыл бұрын
The spark circuit is activated with a relay, so, the control unit removed will have on the spark connectors a small number of ohms. If it's either nothing at all, or shorted at 0 ohms, the secondary coil circuit is toast. You should also be able to get similar readings on the cool primary circuit by unscrewing the control unit base
@Dyt34 Жыл бұрын
Holy shit Steve your a young whipper snapper lol you still have that nice looking hot rod.
@Meantime57 жыл бұрын
Steve, My Riello 40 runs, but does not fire. I checked the oil valve solenoid and got 1.4 K ohms between 1 and 2 and between 1 and 8. The resistance was zero between 2 and 8 (blue and black), even in a new solenoid I got from Ebay. However, the burner sprays oil, which can be seen as a fine mist visible at the chamber window when the burner is started. I'm suspecting the primary control box to be faulty. Is there a way to test the primary control box and the igniter within it?
@trankt541553 жыл бұрын
I think by process of elimination if your pump is still working and the sprayed mist does not ignite then there is not ignition (spark) meaning the transformer is not working. I am thinking you may want to connect leads 3 (neutral) and lead 5 (power) of the control box to 120 v AC power then cover the CAD cell and see if you would get sparks...
@mmack32865 жыл бұрын
If the ceramic from the electrodes where broken or cracked could this have a effect on the burner firing?
@Jason-wc3fh4 жыл бұрын
Yes. The whole point of the ceramic being there is to create an insulation barrier from the high voltage of the sparking electrode jumping prematurely to ground before it jumps to ground near the tip of the nozzle. Once those are cracked, the sparks are always going to try and find the easiest path to the metal ground, which is not the tips of the electrodes.
@sonajuma4 жыл бұрын
Hey Steve, Have a Riello F5 with no power across 3 and 5, no breaker issues, any suggestions?
@stevenlavimoniere4 жыл бұрын
call a local oil burner man for service
@seb00434 жыл бұрын
Hi Everyone, Wanted to know what represents the voltage between 3-7 pins. (39-50Volts) Is this some tachy control or something else ? Thanks
@trankt541553 жыл бұрын
That motor is two speed running at different voltages.
@djianmurphy9 жыл бұрын
Hi steve can you tell me how to check the spark on the transformer as you cant just stick a screwdriver across it
@stevenlavimoniere9 жыл бұрын
***** you can hear the transformer spark there is no way to test it with a screw drive not a reillo if you thing the transformer is bad change it out and see if she fires.
@djianmurphy9 жыл бұрын
thanks steve
@Spencerbuildsit5 жыл бұрын
actually that's just what he does on a service call in another video. Wants it to jump at least 3/4 of an inch
@andysmechanical782511 жыл бұрын
Great job on video Steven Thanks
@stevenlavimoniere11 жыл бұрын
thanks andy
@katherinerodgers531911 жыл бұрын
Thanks again great video.
@stevenlavimoniere11 жыл бұрын
thanks for watching katherine
@InTownPlumbing7 жыл бұрын
your the man ! for this
@ayserabd2 жыл бұрын
Hello, can you help me , I have problem
@kalphanad75268 ай бұрын
What problem
@nicholasceea410910 жыл бұрын
Thanks for the video Steve. I know you don't give a flying crap..lol..but john accer asked about cad cells. They see infrared light and also the normal light spectrum that people see.
@benjaminrideout98934 ай бұрын
I have a riello I replaced control box and I still have no power no noise no sound I hit the reset button multiple times jump 5& 6 no power
@stevenlavimoniere4 ай бұрын
DID YOU CHECK IF THERE IS POWER COMING TO BURNER ??? 5 TO 6 JUST RUNS MOTOR .. YOU PROBE LY HAVE A BAD MOTOR OR CAPACITOR .. IF YOU HAVE POWER TO BURNER AND JUMPED OUT 5 /6 ONLY MOTOR SHOULD RUN FOR PURGING OIL THROUGH PUMP
@nicolaeluchian45057 жыл бұрын
Is anybody have an idea why is furnace smoking,new fuel tank,lines,tigerloop,safety oil valve,ir has air supply straight to the burner but smoke is coming in the house through chimney?
@Spencerbuildsit5 жыл бұрын
check your chimney?
@amitsinhmarsarpanch71534 жыл бұрын
Make down the oil pressure and increase the air pressure if u have black smoke
@amitsinhmarsarpanch71534 жыл бұрын
and check the secondary thermocouple pipe or smoking pipe's thermocouple..