in this video I will show you, how to repair domestic ro unit. less water output or taste less product water how to rectify simply and step by step. #RO #HighTDS #LessWater
Пікірлер: 130
@tamizhselvan96462 жыл бұрын
எனக்கு மிகவும் பயனுள்ளதாக இருந்தது மிக்க நன்றி.🙏
@vincent.m8158 Жыл бұрын
Thanks bro... I followed your steps and finally found that the membrane case was damaged, which was newly purchased. So I replaced that case with an old one and the problem is resolved.
@balakrishnank2028 Жыл бұрын
தேங்க் யூ பிரதர் ரொம்ப தெளிவாகவும் நல்லா புரிந்து கொள்ளும் வகையில் சிறப்பாக விளக்கம் கொடுத்தீர்கள் இதை வைத்து நாங்களே சரிசெய்து கொள்ளமுடியும் very thankful bro
@puroskhan2 жыл бұрын
Super sir very good ideas I am self improvement thank you sir
@veeraanan8308 ай бұрын
Very clear explanation 👏👏👏
@prakashsubramanian81445 күн бұрын
அருமையான பதிவு அண்ணா 🙏
@vengatesh9433 Жыл бұрын
Very useful information.thank you so much sir.
@SaravananSandy-nj7dm9 ай бұрын
தெளிவாக வீடியோ போடுவதற்கு நன்றி நண்பா
@manikkama68836 ай бұрын
Thanks BRO for your clear explanation
@pappavelayutham35029 ай бұрын
நன்றி அருமையான விளக்கம்
@devarajansundaram71302 жыл бұрын
நல்ல பதிவு மிகவும் நன்றி
@ganesankrishnasamy5297 Жыл бұрын
நன்றி நல்ல பயனுள்ள தகவல்
@rajeswaripalanirajeswaripa6174 Жыл бұрын
Good & clear explanation
@shanmugam39916 ай бұрын
RO சம்பந்தமாக எவ்வளவோ வீடியோ பார்த்திருக்கிறேன் உங்களின் வீடியோ மட்டுமே 109% தெளிவான servicing முறையை கற்றுக்கொடுத்துள்ளது. RO பற்றிய basic knowledge உள்ளவர்களுக்கு தங்களின் வீடியோ நல்ல useful ஆக இருக்கும். Pressure gaugeல் எவ்வளவு pressure இருக்கவேண்டும் என்பதை சொல்லவில்லையே Gauge விலை எவ்வளவு நன்றி
@rameshpandiyan28966 ай бұрын
Thelivana vilakkam bro pls ennum more video podunga
@rasigurunathanv1270 Жыл бұрын
Super bro. Thank you so much
@m.ragunathanragu58797 ай бұрын
அருமையான பதிவு
@parthasarathy83082 жыл бұрын
Hi bro useful information thanks
@raviravi-tc3oh Жыл бұрын
Very very good 👍
@sekark93452 жыл бұрын
Super aanna
@adi777X Жыл бұрын
Sir, we have installed RO + UV machine but flow was very low like a droplet but rejection water is good. Why its happened could please explain. I filter flow are clear but. Will I'm try to fix I released Fr it was blowed with air lock.
@deepakk9713Ай бұрын
super,thanking u
@gokulkrish4082 Жыл бұрын
Bro yearly once yethu regular ha check pananum compulsory ha ???
@gokulkrishnan6899 Жыл бұрын
Same issue but membrane filter in Vara water flow fast iruku ... membrane output la irunthu post corbon in porapa low ah iruku yenna problem?
@r.keerthivasana.ramachandr4895 Жыл бұрын
provide specification of the pressure gauge and where to buy this in chennai put the information please
@r.keerthivasana.ramachandr4895 Жыл бұрын
Pressure gauge specification and it's price details please
@parasubpt7 ай бұрын
Thank you so much
@gunasekar2039 Жыл бұрын
Super bro
@mariappans83432 жыл бұрын
Thank you sir
@rmjfaizАй бұрын
16:16 good information
@murugantractor9443 Жыл бұрын
நன்றி
@maniprakash579421 күн бұрын
Ro inlet water TDS ஐ விட product water TDS அதிகமாக இருந்தால் என்ன செய்ய வேண்டும்
@KishorekumarPooruli Жыл бұрын
water flowing from the membrane is very slow and does not fill the tank over a period of time, what is problem, where to identify or locate?
It's recommended to change sediment and carbon filter at the same time for long life
@r2_tech_tamil2 жыл бұрын
I already told this video.. All inline filter.
@featureplanet2 жыл бұрын
@@r2_tech_tamil ok. Actually I don't tamil
@featureplanet2 жыл бұрын
Actually I don't know tamil
@Ataturk.135 ай бұрын
Hello. Home water purification devices have features called bypass, which washes the membrane with purified mains water coming from the pre-filters every time we open and close the purification tap. Does this membrane bypass process work?
@KaruppuSamy-nc3gf Жыл бұрын
Reject water romb athigama iruku bro, product water konjom low ah iruku , enna problem ah irukum bro
@chandrasekaranr74052 жыл бұрын
Sir yanga vitla eruka quard la water yeravum ela plus erangavum ela yana problem nu therla so neega complaint laugh pana direct ah vandhu paapigala
@TUNABGMI Жыл бұрын
SV valve problem
@bharathiarunachalam683810 ай бұрын
Drinking water TDS as per WHO is upto 300. Can we add TDS control to raise drinking water TDS
@Fr4nkSanchez5 ай бұрын
Depends. TDS are minerals but could be any other metals and chemicals. A good RO system should be around 50 TDS or less but you can add a mineralize filter to add magnesium, calcium, etc for our bodies.
@snvgroups1352 жыл бұрын
Bro pump presser minimum yevlo irukavendum maximam yevlo irukum presr gage yengu kidaikum pls reply me
@r2_tech_tamil2 жыл бұрын
Minimum 50 psi, maximum 90 psi..
@JAYANTHAN-fi7ok9 ай бұрын
Pre carbon sediment membrane change panniyum water slowa irruku enna profile irikum?
@r2_tech_tamil9 ай бұрын
SV fault.ah irukalam or pump pressure low.ah irukalam.
@arunkumarkumar27353 ай бұрын
Bro ethu nall membrens solluvengala
@chandrukumar1481 Жыл бұрын
Test varadu yenna pandrudu sir
@ravichandranpondy4872 Жыл бұрын
👍👌✅️
@thimmrayan99902 жыл бұрын
Super Pro 👏
@Ravichandran-fm6cy Жыл бұрын
What is the ratio of rejected and drinking water
@r2_tech_tamil Жыл бұрын
1:3 or 1:4 depending upon water hardness
@vijayanarumugam Жыл бұрын
I have Aquaguard Water purifier Pre filter illama smooth ah work aahuthu.. Pre filter connect panna vittu vittu purify aaguthu What is the problem?
@r2_tech_tamil Жыл бұрын
Pressure switch Ku pressure kedaikala. Pressure switch dummy panaaum or pre filter illama run pananum
@vijayanarumugam Жыл бұрын
@@r2_tech_tamil pre filter illama run pannalama.? Machine problem varatha.?
@r2_tech_tamil Жыл бұрын
Unit inside la oru sediment filter irukum. So no problem. Pre filter additional safety Ku thaan.
@rpgminfo9988 Жыл бұрын
Bro output water bitter taste varuthu bro
@loganathantm23816 ай бұрын
🙏💐🙏👏👍
@venkateshwaran42852 жыл бұрын
Hi ji, product water 71tds, Borewell water 675tds , entha level ok va???
@r2_tech_tamil2 жыл бұрын
Normal than but below 50 TDs vanthathan taste irukum.
@venkateshwaran42852 жыл бұрын
@@r2_tech_tamil ok ji
@venkateshwaran42852 жыл бұрын
Hi ji, contact no?
@chandrukumar1481 Жыл бұрын
Sir kannada video send panno sir
@salomonuq412 жыл бұрын
Hi TDS 39 Is it good for health ?..
@r2_tech_tamil2 жыл бұрын
No.. Above 100 ppm to 500ppm water thaan nama drinking pana suitable agum. But taste irukathu,
@dearcomrade54082 жыл бұрын
No drinking water TDS 50 to 200
@mrvinoth36032 жыл бұрын
Hai bro 39 also good water bro
@mrvinoth36032 жыл бұрын
Suitable for drinking
@petchirajas8825 Жыл бұрын
Precarbon filter la flow nalla tha irukku bro but product water drop drop ah tha irukku
@r2_tech_tamil Жыл бұрын
Membrane change panunga
@parithasan9307 ай бұрын
Ta bro
@ashmeashme Жыл бұрын
Hi bro what if reject water is not coming
@r2_tech_tamil Жыл бұрын
FR block and tube wrongly connected
@rajasekarans67492 жыл бұрын
Bro.. RO la air lock.. eppadi seri pandrathu
@MasterMind-bh1vc Жыл бұрын
Hi brosend me your number
@rd-mu1me10 ай бұрын
Where r u sir
@spkaleekaleeswaran42632 жыл бұрын
உப்பு தண்ணீர் RO இணைக்கலாமா
@r2_tech_tamil2 жыл бұрын
Yes.. salt water ku thaan RO use pannanum.
@rameshkumarmk75682 жыл бұрын
Water full asuna ro off airum but sup moter on la erukkum moter poiratha tel me bro
@r2_tech_tamil2 жыл бұрын
S problem agum. Nama than fill anathuku apram pathu off pannanum.
@rameshkumarmk75682 жыл бұрын
Apadi ovaru time mum paka mutiyathe apa yena pandarathu
@rameshkumarmk75682 жыл бұрын
Unga mobile numper kudunga bro nanu ro telerthan bro
@r2_tech_tamil2 жыл бұрын
Submersible pump input cable RO flot.la kodutha pump and RO unit same time off agidum.
@r2_tech_tamil2 жыл бұрын
But flot Ku ac 230 v phase in kuduthu out edukanum.
@ramuv48052 жыл бұрын
நீங்கள் மாத்திய பில்டர் என்ன விலை வ௫ம் சாா்
@KumarMayavee2 жыл бұрын
200 to 300 variation depends brand
@ramuv48052 жыл бұрын
@@KumarMayavee நன்றி நண்பரே💐💐
@a1incubator2062 жыл бұрын
Model & price sir
@r2_tech_tamil2 жыл бұрын
Carbon filter or total unit..?
@a1incubator2062 жыл бұрын
@@r2_tech_tamil Total unit sir
@vbaranitharantharan96462 жыл бұрын
Bro membrane filter pure water suthama varala Membrane change panniyachi appavum varla
@vbaranitharantharan96462 жыл бұрын
Please reply
@r2_tech_tamil2 жыл бұрын
Fr connect panirukingala..?
@venkatesanmarimuthu454911 ай бұрын
மெமரின் கண்டிசன் அறிவது எப்படி
@r2_tech_tamil11 ай бұрын
Tds high , less taste, high reject and low product water, ithelam symptums ..
@08041985080419852 жыл бұрын
வணக்கம்🙏 சகோ நல்ல பதிவு. உப்பு தண்ணீர் உள்ள எங்க வீட்டில RO system போட முடியுமா எந்த மாதிரி pre filters use பண்ண வேண்டும். எங்க area ல யாரும் RO system install பண்ண வில்லை. ஏன்னா RO சீக்கிரமே கெட்டுப்போய் விடும் னு சொல்லுகிறார்கள். இதற்கு ஏதாவது தீர்வு இருக்கிறதா . நாங்கள் இந்த தண்ணில தான் குளி ப்போம் குடித்து பார்த்தால் கொஞ்சமா உப்பு கரிக்கிறது மாதிரி இருக்கு. எந்த அளவு TDS வரை RO வால் Filter செய்ய முடியும். இது பற்றிய பதிவு இருந்தால் link குடுங்க இல்ல reply பண்ணுங்க சகோ please
@chandramoulimouli69782 жыл бұрын
Entha oor and area
@08041985080419852 жыл бұрын
@@chandramoulimouli6978 Saltlake in Kolkata இங்க 1600 TO 1900 வரை TDS இருக்கு
@jeeva5388 Жыл бұрын
Message me sir
@mageemahi61672 жыл бұрын
Correct Water tds range yenna irukanum sir
@r2_tech_tamil2 жыл бұрын
I don't know exactly.. But my personal suggestion 35 to 70 ppm.
@mageemahi61672 жыл бұрын
Sir my home ro unit tds is 8 only is good are bad sir
@r2_tech_tamil2 жыл бұрын
Not good.. U can mineral catrage. Its increase our TDs level.
@mageemahi61672 жыл бұрын
Mineral catrage add pannanum maa sir
@r2_tech_tamil2 жыл бұрын
Yes..
@user-oo2ql8yu9z2 жыл бұрын
இன்னும் அனுபவம் தேவை
@r2_tech_tamil2 жыл бұрын
நன்றி..
@ramuv48052 жыл бұрын
சாா் கடை எங்கே ௨ள்ளது
@r2_tech_tamil2 жыл бұрын
Trichy
@Paulmeshak-r8z Жыл бұрын
@@r2_tech_tamil please give me your Phone number Annan
@rajvinith66452 жыл бұрын
Stupid 850 ku 85 normal thaan.,
@r2_tech_tamil2 жыл бұрын
OK genius..
@rajvinith66452 жыл бұрын
@@r2_tech_tamil Medhavi.... Ro formula itself 7-10% of raw water TDS For 3 example tap water is 1000 means good water will be 70-100.... Don't share wrong information video...
@r2_tech_tamil2 жыл бұрын
OK brother you are telling about theory.. I am telling about practical.. 1500 ppm raw water Ku 150 ppm product water vantha customer taste illenu souvanga.. Below 50 ppm vanthathan taste kedaikum.
@rajvinith66452 жыл бұрын
@@r2_tech_tamil For that we can't change membrane formula... Membrane is manufactured on that formula only. If water hardness is less u will get 3-5% output... Purely depends on water hardness only.... If raw water is 1500plus & hardness is also high. Ro will come only 150-200. For that u need to increase the pressure of the pump . So have to go for 36V pump, sv & adaptor..