RO Flow Restrictor value calculation

  Рет қаралды 253,139

Reviewmaza

Reviewmaza

Күн бұрын

Пікірлер: 291
@Mukeshmiktecrep
@Mukeshmiktecrep 8 жыл бұрын
Everything you said is wrong, Flow restrictor is used to restrict the water flow to create pressure on the membrane so that pressured water molecules can pass through the membrane pores, without the Flow restrictor the water just pass over the membrane and go to drain side and you will not get pure water.
@do-rightsolar6455
@do-rightsolar6455 6 жыл бұрын
What pressure does it create at the membrane? Does it depend on which restrictor one uses? Is the flow restrictor just a skinny tube on the inside? Thanks!
@devawratvidhate9093
@devawratvidhate9093 6 жыл бұрын
What is right calculation for flow restrictor
@gregoriperalmannn
@gregoriperalmannn 4 жыл бұрын
VALIDPOINT!
@ArunShankartheRealOne
@ArunShankartheRealOne 4 жыл бұрын
Not everything, his calculation is correct, but the reasoning is wrong. Using Lowe value flow restrictor would increase water wastage. Let's assume the inlet water has a pump of 700 ppm, the wastage water's ppm coming out of the ro membrane might be 800 approx when 350 FR restrictor is used, when using 450 FR it would be around 900+. So using the wrong Flow restrictor would increase water wastage.
@bganguly100
@bganguly100 4 жыл бұрын
@@ArunShankartheRealOne Sirji I think you told the correct reason but got I confused a bit on your example... Please note that you have mentioned 350 FR would result 800 wastage and 450 would result 900+. Here you are telling that if we increase from 350 to 450 then the wastage would be more? i mean from 800 to 900+? I am sorry to point this but doing it just to clear my confusion. Please don't mind, its not to proof you wrong, but to clarify my understanding
@ROMTHIRTY
@ROMTHIRTY 3 жыл бұрын
Just replaced all my RO filters and I kept hearing constant water being wasted at an incredibly high rate. I found a tiny flow restrictive in my line, maybe the previous filter didn’t need much pressure so it worked before? But your video just helped me determine the importance of having a flow restrictor. I just ordered one based on your calculations. Thank you and I’m confident this will fix my problems.
@DIY_ZINDAGI
@DIY_ZINDAGI 2 жыл бұрын
I replaced all my filters but now water I m having tds of RO water is same as tds of tap water. What should I do?? Is sv not working or fr is not working??
@Swanicorn
@Swanicorn 4 жыл бұрын
If FR value is higher, 450 compared to 800, then that means 800 is more restrictive than 450. I think such a conclusion should have been mentioned in the video. 800 FR is allowing more water to go through the membrane and less water is wasted via blue drain pipe. 450 will waste more water compared to 800. Higher FR value should reduce the life of the membrane IMO since it causes more water to pass through the membrane. More water passing through membrane means more wear and tear or higher possibility of membrane blockage which means lesser lifetime of the membrane.
@mdfaisal216
@mdfaisal216 2 жыл бұрын
No wrong ....fr blocks drain pipe ...if used 300 fr then water wastage would be less but system will work in high pressure ....more water will go through the membrane
@Swanicorn
@Swanicorn 2 жыл бұрын
@@mdfaisal216 I replied to you with a blog post that did all the calculations. It got deleted because it was a website link. You can google it yourself if you want. In short let me explain: The FR number means how much it will restrict the flow of rejected water. Higher value means it will force more water through the membrane. A 75 to 100 GPD RO membrane should use 800 FR. Less GPD membranes should use lesser value FR. Higher FR value means more water will be purified and less will be drained. So FR800 drains less water than FR450.
@Swanicorn
@Swanicorn 2 жыл бұрын
@@mdfaisal216 Whatever I said is mentioned on the supplier/manufacturers website. They have a table for what value FR to use for how much GPD membrane.
@patricpdp7380
@patricpdp7380 Жыл бұрын
I just tried joining 2 FR of 450 in parallel and series both but did not make any difference. I noticed same amount of drain water and pure water coming out.
@Mukeshmiktecrep
@Mukeshmiktecrep 8 жыл бұрын
The Flow restrictor is added to the drain side not to the inlet side, the gasket seal is expanded automatically by the Booster pump pressure at inlet side........... I am sure you don't know anything how it works.
@rabimahapatra8687
@rabimahapatra8687 7 жыл бұрын
MikTecRep ; Dude, I very much agree with you...
@sanjeev45087
@sanjeev45087 6 жыл бұрын
english me agar अटक रहे हो तो हिन्दी मे talk kar lo sir,, सभी को जल्दि ओर सही समझ मे आयेगा
@gregoriperalmannn
@gregoriperalmannn 4 жыл бұрын
MIKTECREP....YUP......I HAVE TO FORGET ALL INFO I LEARNED FROM THE VIDOE NOW
@veer1556
@veer1556 3 жыл бұрын
Sab golmaal, kya master banega re tu 😂😂
@someoyou
@someoyou 7 жыл бұрын
I do service for many RO residential systems in my city, most of them have 420ml flow restrictor and 75G memranes, TDS of input water is usually 350 to 500ppm and everything works fine, memranes last for about 3-4 years sometimes more. Usually I try to change the restrictor when changin 75 to 50G membrane and so on. Klaudio Berger very useful tips, thnx!
@reviewmaza
@reviewmaza 7 жыл бұрын
+Oleg Reshetov . Thanks 4 ur valuable feedback
@naveenssps
@naveenssps 7 жыл бұрын
Oleg Reshetov Is it compulsory to change the flow restrictor when we change the RO membrane, if so why?
@someoyou
@someoyou 7 жыл бұрын
you better change flow restrictor if you replace 50gal membrane with 100 or 125gal membrane. When change 50 to 75 I dont change restrictor.
@reviewmaza
@reviewmaza 7 жыл бұрын
Thankyou for your valuable feedback... 😁
@relevation
@relevation 6 жыл бұрын
Hi can i ask you something. My ro doesnt generate waste water at all...Nothing comes out of the drain tube. May i know whats wrong with it?
@Mukeshmiktecrep
@Mukeshmiktecrep 8 жыл бұрын
Flow restrictor is not calculated only the membrane, it also depends on the water pressure, TDS of inlet water.
@bharathiarunachalam1949
@bharathiarunachalam1949 Жыл бұрын
Thank you For 80 and 100 gpd membrane If I add again one more 300 FR after 450 it be comes 750 FR.. Will it work or damage membrane life. Can you give your suggestions. Am waiting for you Mr
@bhaskarscollection9894
@bhaskarscollection9894 2 жыл бұрын
Hi bro, Thank you for this video. I replaced a FR450 with a new one of same value which came alongwith new RO membrane. But I noticed a lot of water going waste and usable water flow was very low. When I connected the old FR alongwith new one in series, I am getting normal flow of usable and waste water. Is it that the new FR is defective or any fault other than FR?
@tarkanmercan9918
@tarkanmercan9918 2 жыл бұрын
Sir . my I use 75 gp membrane and tds is 300 normallya.. Which flow can I use? I use 300 now... What is your opinion? (My pressure is 4 bar and I dont use pomp machine)
@reviewmaza
@reviewmaza 2 жыл бұрын
450
@shardaarvind123
@shardaarvind123 7 жыл бұрын
Hi, I have Kent RO water filter. When I remove wire from FRT , water is coming out from rejected water pipe. But when I add FRT then rejected water is not coming out. Can you suggest what can be the problem.
@reviewmaza
@reviewmaza 7 жыл бұрын
+Arvind Sharda replace the FR
@bganguly100
@bganguly100 4 жыл бұрын
I have a confusion here... I have checked and found that 600 is the highest value of the flow restrictor available on amazon.... that means it is again not suitable with 80 GPD membrane. so what is the alternative
@georgechristepher2118
@georgechristepher2118 5 жыл бұрын
Which shop will we get FR and Y connector
@TheRj_007
@TheRj_007 2 жыл бұрын
bhai 80 gpd membrane or pump h or tds 800 h ot konsa fr lagaye
@prafullsabat
@prafullsabat 7 жыл бұрын
My kent Supreme has a factory fitted Flow Restrictor of Rating 300, and it says capacity of 15L/hr, iam in process of changing the Membrane to 75gpd which flow restricor should i use ideally ?
@reviewmaza
@reviewmaza 7 жыл бұрын
FR 450
@reviewmaza
@reviewmaza 7 жыл бұрын
75 GPD SHALL GIVE YOU 10 TO 12 LITER. BETTER GO FOR 80GPD. WITH FR 450
@mohammadgulab2728
@mohammadgulab2728 3 жыл бұрын
@@reviewmaza but you said for 75 GPD membranes we must use FR 800
@ramborums
@ramborums 5 жыл бұрын
I get good flow from the pure outlet but almost no flow from the reject line. Could the restrictor be clogged? What can i do? Thanks
@reviewmaza
@reviewmaza 5 жыл бұрын
Yes. change the FR
@sundarjaya7244
@sundarjaya7244 3 жыл бұрын
When doing FR calculation it is not properly focused and you can use sketch pen instead of using light color. I am unable to catch perfectly.
@TheExcessivemhz
@TheExcessivemhz 5 жыл бұрын
Thanks for the video! Could you please help: my RO filter doesn't produce Waste Water at all! Is it normal ? Or something is wrong ?
@raam1702
@raam1702 4 жыл бұрын
There is a problem in ro candle and check the flow restrictor(pressure valve)
@VijaySingh-ic5px
@VijaySingh-ic5px 5 жыл бұрын
100 gpd membrane n 100 gpd pump me kon sa flowsictor lagana chahiye.. 450 ya 550
@suseelaballina2952
@suseelaballina2952 7 жыл бұрын
Water does not have countnes flow in side the pot after passing through members what is the problem
@siddiquihomeopathy422
@siddiquihomeopathy422 3 жыл бұрын
i have used 100 gpd membrain but fr 300 is it good ?
@ABDULAZIZ272
@ABDULAZIZ272 7 жыл бұрын
My input water tds is 245. I want to bring it down to below 10 tds not for drinking. Which flow restrictor should I use with 300 gpd ro membrane and 300 gpd booster pump. Please help me.
@reviewmaza
@reviewmaza 7 жыл бұрын
+Md.Abdul Aziz ok . Pl give ur no
@ABDULAZIZ272
@ABDULAZIZ272 7 жыл бұрын
Reviewmaza my mobile no. is 9957258567
@vinothkannan4572
@vinothkannan4572 7 жыл бұрын
my bnqs bump not able to generate as they membrane require pressure can i use under value flow resistrictor for create pressure for manually because you told ur videos bnqs bump is the best............
@Studywithumair
@Studywithumair 7 жыл бұрын
sir can we use ro membrane without booster pump ..with high pressure inpit
@reviewmaza
@reviewmaza 7 жыл бұрын
+MOHAMMAD UMAIR no. If pressure is low u cant use ro membrane
@Studywithumair
@Studywithumair 7 жыл бұрын
Reviewmaza :my water pressure is high sir ..sir please make a sall video about without booster pump ro membrane ..please sir
@rajeshnanecha
@rajeshnanecha 6 жыл бұрын
I am using 75 gpd membrane and flow restrictor is 450. Now I want to add 80 gpd membrane in my ro filter should I change ro flow restrictor ? If yes then pl. suggest.
@reviewmaza
@reviewmaza 6 жыл бұрын
Yes you mus use new fr for new membrane
@MrSayog
@MrSayog 6 жыл бұрын
Bhai mere kent prime Ro ki membrane ki out let pipe se drop drop krke water aata he kya wo block ho gyee hein inlet pipe se full pressure ja raha hein carbon filter ka baad I checked just Ro memebrane
@subhashsaini7755
@subhashsaini7755 7 жыл бұрын
Sir, 75gpd membrane ke liye FRT konsa use kre
@Ruthrasivasakthi
@Ruthrasivasakthi 7 жыл бұрын
What is the color of drain water. If is white any problem
@reviewmaza
@reviewmaza 7 жыл бұрын
+Sakthi Vel no problem . Actually in foreign contries blue color is used for pure water and red color is used for reject water. In India we use any color
@pavlosm8827
@pavlosm8827 7 жыл бұрын
If it's whitish this probably means it's high in TDS
@bishwajeetmahato9924
@bishwajeetmahato9924 7 жыл бұрын
my actual water tds is 400 which member should i use for better result, i need 50 tds
@reviewmaza
@reviewmaza 7 жыл бұрын
+Bishwajeet Mahato use pentair. 75 gpd
@bishwajeetmahato9924
@bishwajeetmahato9924 7 жыл бұрын
Reviewmaza and FR 800
@MultiBibhudatta
@MultiBibhudatta 7 жыл бұрын
i want to buy a tds meter from which brand and from where i will buy?please reply sir
@sathishmn5188
@sathishmn5188 7 жыл бұрын
HM brand is good for home use
@vickygpandori5851
@vickygpandori5851 6 жыл бұрын
Sir 70 gpd membrane 70gpd pump per kon sa flow e j kter lagana ha
@ariseagain3423
@ariseagain3423 6 жыл бұрын
vikaram singh 450ccm
@damusscone4373
@damusscone4373 8 жыл бұрын
do you think aquadyne ro coponents are good for local ro systems
@reviewmaza
@reviewmaza 8 жыл бұрын
Damu Sscone dear sir, thanks for the question. aquadyne i suppose if you dont have any option. other wise you can go for good brand names .
@damusscone4373
@damusscone4373 8 жыл бұрын
i have a mineral ro system 1 year old the taste of water is degraded now. also the rejected water coming out is very low. should i change the entire components including the ro membrane. also suggest some good brands
@reviewmaza
@reviewmaza 8 жыл бұрын
+Damu Sscone genrally after 1 year you must replace all components.
@HimanshuSharma-bb7mi
@HimanshuSharma-bb7mi 4 жыл бұрын
My membrane is of rating 75 gdp and the water tds is 600 ppm can I use 300 mlm flow restrictor?
@amrinderpalsinghbains1188
@amrinderpalsinghbains1188 2 жыл бұрын
Which fr u used
@ncertzone2249
@ncertzone2249 7 жыл бұрын
Sir plz bataen ki 'nexus' company ka ro filter kaisa rahega for tds between 900 to 1000
@reviewmaza
@reviewmaza 7 жыл бұрын
+anzar ata better go for hitech filters
@ncertzone2249
@ncertzone2249 7 жыл бұрын
Reviewmaza hitech filter nexus nahi hi? agar nahi hi to kon si company ka hitech filter hi plz bataen ?
@patelbijal422
@patelbijal422 5 жыл бұрын
Sir mera ro dulphine ka hai aur mere ro me pani ka test nahi aarha hai tds bhi 94 hai to aub me kya karu jo muje pani ka test acha mile
@reviewmaza
@reviewmaza 5 жыл бұрын
Check membrane
@nileshtikkas9674
@nileshtikkas9674 5 жыл бұрын
Sir 100 gpd membrane ko konsa FR lagana chahiye. Aur 300gpd membrane ko konsa FR lagana chahiye. Plz tell me
@krish2542
@krish2542 5 жыл бұрын
It depends on motor output value. By the way, 100gpd RO system (domestic) and 300gpd RO system (commercial) use different sized pipes, connectors, etc.
@415AS
@415AS 6 жыл бұрын
Livpure purfier Tds is less than 10 what should I do there is no tds adjuster.
@epc123456
@epc123456 5 жыл бұрын
Throw it. Product water TDS should be atleast 200 -250 TDS so that you can get necessary minerals. Very low TDS water is closer to distilled water and gets acidic. Thats why tingling taste which people say its sweter...
@sandeepbompally8998
@sandeepbompally8998 7 жыл бұрын
what will happens if use 100 gbd membrane for 80gbd pump is it creates any problems???
@reviewmaza
@reviewmaza 7 жыл бұрын
after some days membrane will get weak. and also may get damaged
@ariseagain3423
@ariseagain3423 6 жыл бұрын
Kuch nhi hoga tensn na lo
@atulchauhan3931
@atulchauhan3931 7 жыл бұрын
What post carbon does and how it is different from mineral cartridge?????
@davdaamit
@davdaamit 7 жыл бұрын
At present in my ro it's 450 fr should i upgrade to 800 fr ? 75gpd membrane is installed before 2 months
@davdaamit
@davdaamit 7 жыл бұрын
My ro Motor is week as told by installer so do suggest ...
@reviewmaza
@reviewmaza 7 жыл бұрын
+Amit Davda no.if ur motor is weak then jo h wohi thik h.
@RUSHI251
@RUSHI251 5 жыл бұрын
For 80 gpd membrane which FR used ?
@purushothamnikkam6069
@purushothamnikkam6069 6 жыл бұрын
where do u get these spares? also let me know if there is any specific brand?
@reviewmaza
@reviewmaza 6 жыл бұрын
whatsapp me 7972197566
@damusscone4373
@damusscone4373 7 жыл бұрын
is there a need to change a flow restrictor , if yes , when should be change it, after how many days or months
@reviewmaza
@reviewmaza 7 жыл бұрын
Damu Sscone it must be replaced when you replace any inline filter or Membrane
@martinvarkey150
@martinvarkey150 7 жыл бұрын
What is the GPD value of Kent grant plus RO filter (concealed one)
@reviewmaza
@reviewmaza 7 жыл бұрын
+Martin Varkey 80 gpd or 75 gpd
@amanmaheshwari2537
@amanmaheshwari2537 7 жыл бұрын
mereko 300gpd pump &300 gpd membrane me fr lagana hai kitne value ka lagana hoga
@arsxplr
@arsxplr 7 жыл бұрын
i have ro purifier...and waste water not stopped after ro machine switched off...plz tell me the solution ....
@reviewmaza
@reviewmaza 7 жыл бұрын
brother your Solenoid valve has been damaged, please replace it so that problem will be solved. buy solenoid valve amazon : amzn.to/2mXcNqH
@someoyou
@someoyou 7 жыл бұрын
check and replace your 4-way valve if you have one in your system
@arsxplr
@arsxplr 7 жыл бұрын
thank u for kind reply...it is a problem of SV (solenoid Valve) and solved the problem after replacing the valve.
@reviewmaza
@reviewmaza 7 жыл бұрын
Happy to help.. Please subscribe our channel .
@shancochin2010
@shancochin2010 8 жыл бұрын
super macha.Where did you study all this? what about 0.38 factor coming into these calculations?
@reviewmaza
@reviewmaza 8 жыл бұрын
Hi.. I read it in some Membrane manufacturers Website.. I dnt remember it.. but its correct for shure...
@reviewmaza
@reviewmaza 8 жыл бұрын
goo.gl/2EWch8
@dipuxu
@dipuxu 5 жыл бұрын
i use 450 for 80 gpd. If i use 500 or 800 FR is possible that output of flow increasing.
@amrinderpalsinghbains1188
@amrinderpalsinghbains1188 2 жыл бұрын
No output of pure water will decrease
@Peter-kt5rr
@Peter-kt5rr 4 жыл бұрын
Thank you for taking time to this video. It helped me determine the correct size for my 100GPD unit.
@darrinhawkey8913
@darrinhawkey8913 3 жыл бұрын
?? what one was it ?
@Peter-kt5rr
@Peter-kt5rr 3 жыл бұрын
@@darrinhawkey8913 the Flow Restrictor video for RO Units
@deepaksingh-ye1cv
@deepaksingh-ye1cv 7 жыл бұрын
Mere philter ki membrin nai h or kuch dino bad wo kam pani filter kr rhi h sb kuch change kraya tha mene lekin pani der s philter kr rhi h ab mene usme 450 ki 2 fr lgai h pani to sai philter horha h but usse koi pareshani to nai hogi n
@reviewmaza
@reviewmaza 7 жыл бұрын
+deepak singh nai
@reviewmaza
@reviewmaza 7 жыл бұрын
+deepak singh 300 ke 2 Laga do
@chingeshkhan5182
@chingeshkhan5182 7 жыл бұрын
sir my to water is not sweet my TDS is 1800 to membranes 50 gpd CMS, filter ro with bio cera alkaline cartage 260 TDS but water is not sweet kindly tell me how to increase water sweetnees.i want little hard water.
@reviewmaza
@reviewmaza 7 жыл бұрын
+chingesh khan 1800 tds is to high . And product water is also high in tds.
@chingeshkhan5182
@chingeshkhan5182 7 жыл бұрын
Reviewmaza I'm asking you for solution,I knw this already,my tab water is 1800. n ro water is 260 with alkanine cartage,but water is not sweet,n flow of my incoming ro water is dip,so slow, m using csm 50 gpd membrane with 300 fr.
@vinothkannan4572
@vinothkannan4572 7 жыл бұрын
chenge your high tds ro membrane go with dow filmtech is the best for high tds,,,,,
@ariseagain3423
@ariseagain3423 6 жыл бұрын
Brother use multiple post carbon filter it will make water taste sweet And if you want lower TDS water use multiple ro membrane 100 or 80 gpd membrane 1st and second will be 50gpd in series, Re-circulate second membrane product water to pump inlet with main inlet You will see your TDS drop and taste improve. Membrane life increase
@abhijeetjanjalkar3569
@abhijeetjanjalkar3569 6 жыл бұрын
light green colour inside the pipe of ro why?
@lawiez
@lawiez 6 жыл бұрын
hello, nice video! if i'm running 2 100 gpd membranes in series, ie, waste water from 1st membrane feeds the second, what kind of flow restrictor should i get?
@reviewmaza
@reviewmaza 6 жыл бұрын
Fr 650-850
@lawiez
@lawiez 6 жыл бұрын
thank you!
@ariseagain3423
@ariseagain3423 6 жыл бұрын
In series combination system work in 1:1 (clean : waste) you need only 300ccm . Calculate if both membrane work 30% recovery then take 100L(litter) and make 30L clean water and 70L waste In series that 70 went again in next membrane 21L clean and 49L waste So clean water 51L(30+21) and waste only 49L Means now system work 51:49 For your system 250ccm sufficient. So use 300ccm only
@reviewmaza
@reviewmaza 6 жыл бұрын
actually you are correct to some extent, but the membrane which is prior will get damaged soon, due to clogging. if we do not give 1:4 rejection.
@ariseagain3423
@ariseagain3423 6 жыл бұрын
I just giving correct fr value for system on the basis of giving information Now one more data needed for considering membrane life waste water TDS If waste water didn't reached 1000+ TDS system can run with 300fr If waste water have more TDS than 1000 then use fr 550 only By using fr550 system run on 1:4
@hemantkvlog8400
@hemantkvlog8400 6 жыл бұрын
Sir..pura pani bahar nikal rha h store nhi ho rha h kya problem batayiye pls
@reviewmaza
@reviewmaza 6 жыл бұрын
watsapp me 7972197566
@chahatkhanna5276
@chahatkhanna5276 7 жыл бұрын
Can flow restrictor be used in opposite direction
@reviewmaza
@reviewmaza 7 жыл бұрын
+chahat khanna no
@9971439099
@9971439099 6 жыл бұрын
Mere ro ka rejected water apne aap bahar aata hai power of hone ke baad bhe ?.
@jaswantsuthar90
@jaswantsuthar90 5 жыл бұрын
CHANGE SV VALVE
@devendrabhattacharya
@devendrabhattacharya 7 жыл бұрын
50gpd membrens which FR no can be use
@reviewmaza
@reviewmaza 7 жыл бұрын
+devendra bhattacharya Fr 300
@surendrakumarmishra2755
@surendrakumarmishra2755 6 жыл бұрын
75gpdmembrens which FR number be use..
@ParveenKumar-zi6se
@ParveenKumar-zi6se 6 жыл бұрын
मेरे घर पर KENT SUPER PLUS 8 Ltr Ro लगा हुआ है। पहले 75 GPD की membrane व FR 550 लगी थी । मैने अब मेम्ब्रेन चेंज कर दी ह जो CSM 50 GPD की है ।क्या अब मुझे FR बदलनी पड़ेगी।
@reviewmaza
@reviewmaza 6 жыл бұрын
ha.. 300 lagao ..
@bramhagyani5018
@bramhagyani5018 2 жыл бұрын
Flow restrictor is not for to expand o ring, it is meant for back pressure generation.
@prashantdubey998
@prashantdubey998 7 жыл бұрын
hey bro nice vedio... really helpful... I have ro purifier and I have replace the ro membrane last month and it's working properly... but from last two three days the output filtered water is coming at a very low speed.. it takes about 12 to 13 hrs to filter 12 ltr of water and waste water is so much... pls help me out to solve the problem... ro membrane is csm 75 gpd ... help me out... pls
@reviewmaza
@reviewmaza 7 жыл бұрын
+prashant dubey did you also replaced the flow restrictor?
@villagersvlogs4565
@villagersvlogs4565 7 жыл бұрын
i watched our most of the videos.now i want to buil ro+uv+tds water purifier at home. where should i get all the components. I am from Pune. Please tell me.
@reviewmaza
@reviewmaza 7 жыл бұрын
+Ajit Anpat you can get many suppliers from indiamart
@villagersvlogs4565
@villagersvlogs4565 7 жыл бұрын
Thank You sir...
@villagersvlogs4565
@villagersvlogs4565 7 жыл бұрын
I saw many suppliers on indiamart now i am confused about brands, so suggest me the brands of all parts please. my email id is ajitanpat55@gmail.com
@hareshdodiya2658
@hareshdodiya2658 7 жыл бұрын
Ajit Anpat for more detail WhatsApp me on 9723477627
@abishekba4149
@abishekba4149 7 жыл бұрын
i would like to use an RO to reduce the TDS of tap water for bathing,not for drinking it.Inlet Water TDS is 900 i would like to reduce it to 250 TDS not to 90.i thinking of using 2 or 3 ro membrane in series with booster pump in between the membrane to reduce waste water waste from the normal ratio of 4:1,Can you give any suggestions How can a flow restrictor be used to increase the RO output to get higher TDS upto 250, i don't mind replacing the ro membrane due to premature fouling once in 6 months also.Suggestions
@reviewmaza
@reviewmaza 7 жыл бұрын
kzbin.info/www/bejne/gXKZkKagn9qnl6M
@reviewmaza
@reviewmaza 7 жыл бұрын
Pls see the reply video...
@sandeepbompally8998
@sandeepbompally8998 7 жыл бұрын
can u tell me about the quality of hi-tech company products
@vipindhiman7645
@vipindhiman7645 6 жыл бұрын
f.r ki jagah nal ki tonti lgaa de aur waste water ki speed slow kar de to Kya nuksan ho jaayga
@reviewmaza
@reviewmaza 6 жыл бұрын
MEMBRANE BLOCK HO JAYEGA
@ROWaterSupports
@ROWaterSupports 4 жыл бұрын
Yes Sir. You say 100% right.
@WaterXpert
@WaterXpert 6 жыл бұрын
In my new RO reject ro continues even i changed sv n housing still problem continues
@reviewmaza
@reviewmaza 6 жыл бұрын
oh .
@asankar228
@asankar228 4 жыл бұрын
Hi can i have ur number please... My RO output water is very slow and RO takes more time to fill 7 lts... How to increase the flow... Please help
@reviewmaza
@reviewmaza 4 жыл бұрын
api.whatsapp.com/send?phone=+917972197566
@reviewmaza
@reviewmaza 4 жыл бұрын
Replace ro membane
@rishitasaini5283
@rishitasaini5283 4 жыл бұрын
When you make vdo plz price must be tell us.
@rajendarsingh4777
@rajendarsingh4777 7 жыл бұрын
how many cost of solenoid valve
@reviewmaza
@reviewmaza 7 жыл бұрын
Rajendar Singh depends on company
@Mukeshmiktecrep
@Mukeshmiktecrep 8 жыл бұрын
Wrong: Flow restrictor does not generates pressure RO Pump does.
@reviewmaza
@reviewmaza 8 жыл бұрын
Mukesh flow restrictior restricts flow so generate reverse pressure
@collins51070
@collins51070 6 жыл бұрын
Miktecrep sir then please tell me how to select the FR against TDS
@subhashsaini7755
@subhashsaini7755 7 жыл бұрын
Sir, mere RO membrane me clean water dire dire(बुंद-बुंद)aa rha h & dirty water fast as rha h,sir please problem btao.
@mrgoludau4690
@mrgoludau4690 6 жыл бұрын
same problam he .....ans. nahi de rahe he sir
@sayurmesh7639
@sayurmesh7639 6 жыл бұрын
I think your membrane is chocked. Replace it
@buddhiprakashmeena2481
@buddhiprakashmeena2481 6 жыл бұрын
मेम्ब्रेन चेंज कर लो
@SadanandaUTube
@SadanandaUTube 7 жыл бұрын
Thanks for your good information about relation of Membrane with flow restrictor
@reviewmaza
@reviewmaza 7 жыл бұрын
+Sadananda Dey welcome bro
@puriaa
@puriaa 7 жыл бұрын
wud u b so kind enough to post it in hindi, so that all people can understand it . now i have a problem dear. one night the over head tank of ours got emptied and d kent machine installed in our house kept running for 6 hours (without water). from then onward very low water with air is coming out from d tube that ejects rejected water and it takes much much time to fill the container. plz help me out as soon as possible. what might have bn happened and if i call the kent personnel how much will it cost to me . plz let me know.
@reviewmaza
@reviewmaza 7 жыл бұрын
+jeetendra kumar pallai membrane has been damaged due to low pressure
@puriaa
@puriaa 7 жыл бұрын
sir thanx a lot for having reciprocated to my message. so what wud d cost i have to incur and is there any other damage caused to the machine
@reviewmaza
@reviewmaza 7 жыл бұрын
+jeetendra kumar pallai how much old is your machine?
@puriaa
@puriaa 7 жыл бұрын
Reviewmaza . It's a 9 yr old machine but 1 1/2 YR back everything including d motor was changed.
@reviewmaza
@reviewmaza 7 жыл бұрын
you will hav to change ro+ inline filters + flow restrictor
@balwantkumar4892
@balwantkumar4892 6 жыл бұрын
What is the measurement of .38
@ankitjangrag8924
@ankitjangrag8924 4 жыл бұрын
50 gpd for which quality fr plz tgol
@YogenderShandilya
@YogenderShandilya 5 жыл бұрын
Sir ro का आउटपुट पाइप कितनी ऊचाई तक पानी पहुंचा सकता है
@shravanghatage1059
@shravanghatage1059 7 жыл бұрын
What stands for. 38
@reviewmaza
@reviewmaza 7 жыл бұрын
it is a value that is used for the calculation.
@Studywithumair
@Studywithumair 7 жыл бұрын
i have uf uv filter ..but i need to ro .
@chayanbhowmick3800
@chayanbhowmick3800 6 жыл бұрын
Hi sir I am looking for a installation training
@karunasagardheram598
@karunasagardheram598 3 жыл бұрын
We understand that you have not understood yourself! A restrictor results in back pressure, which necessary for RO, which itself needs pressure to pass through a membrane. Please go through the process of reverse osmosis!
@MrAnirbanchakrabarty
@MrAnirbanchakrabarty 6 жыл бұрын
How much for 300 GPD ro membrane
@varunsardana2700
@varunsardana2700 6 жыл бұрын
awesome....thats a scientific answer......really impressed.....
@hthiru7016
@hthiru7016 4 жыл бұрын
What is .38
@Swanicorn
@Swanicorn 4 жыл бұрын
Gallon per day to milliliter per minute conversion ratio.
@Civilcontra
@Civilcontra 7 жыл бұрын
bhai installing kaise kare pipe ki ho bata
@subhashchander5572
@subhashchander5572 4 жыл бұрын
Very good topic,but audio is not laud n clear.
@Rajvi14.318
@Rajvi14.318 7 жыл бұрын
angreji ki jagah Hindi me vdo banaoge to bahut logo ko phayda hoga, bahut kam log aapke channel ko subscribe karenge, Hindi me bologe to vdo jaldi banegi aur bahut likes bhi milenge
@reviewmaza
@reviewmaza 7 жыл бұрын
bhai ye to purnana video h.. abi sare naye videos hindi me hi h..
@NeonblueIndustries
@NeonblueIndustries 7 жыл бұрын
Back pressure caused by the restrictor FORCES water molecules to be pushed through the membrane. This is bypassed when you want to flush the R/O surface to help it keep clear. This can add extra life of the R/O membrane.
@reviewmaza
@reviewmaza 7 жыл бұрын
+Neonblue Industries correct
@gopikrishna3226
@gopikrishna3226 4 жыл бұрын
A boku kvle akda vntade sir
@gopikrishna3226
@gopikrishna3226 4 жыл бұрын
Book akkda dhorukuthudhi sir
@sakthivel1788
@sakthivel1788 3 жыл бұрын
Why divide 4
@reviewmaza
@reviewmaza 3 жыл бұрын
1:4
@ziaulislammamun3795
@ziaulislammamun3795 4 жыл бұрын
Can you please explain more how a flow restrictor works and if an RO purifier does have it what will happen? Meaning কি, কি ভাবে কাজ করে, কি জন্য দরকার, না হলে কি সমস্যা ।
@babudhi
@babudhi 4 жыл бұрын
Flow restrictor is used to create pressure on RO membrane. There is one water inlet and 2 outlets(One is for for pure water and other is for waste water) in a RO housing. There is direct flow of water from inlet to outlet. Pure water is taken form membrane from pure water outlet. Now, to extract water through RO membrane requires high pressure. So if we not use flow restrictor, enough pressure will not build up and water will directly pass through outlet. So, by adding flow restrictor pressure build up inside housing and water squeezes through membrane and comes out through pure water outlet. Hope you understand.
@shravan4469
@shravan4469 6 жыл бұрын
Good one Bro...👏👏👍
@vikiraman8398
@vikiraman8398 5 жыл бұрын
Super sir you are very kind thank you you share all knowledge about RO system thank you very much
@biswajitbhattacharyya9217
@biswajitbhattacharyya9217 3 жыл бұрын
Very good info! Thanks! 👍
@reviewmaza
@reviewmaza 3 жыл бұрын
Glad it was helpful!
@vijaymareddi4514
@vijaymareddi4514 4 жыл бұрын
Sir pls hindi main video banaye ta ki sabko samj Main aye. Kyon ki mostly technicians English jante nahi
@VijayKumar-qj3up
@VijayKumar-qj3up 5 жыл бұрын
Angreji kidhar sikhe ho bhaiya
@rishisakuja4347
@rishisakuja4347 7 жыл бұрын
Sir mera mineral water ka business he isme Maine csm ki membrane lagayi he uska flow pehle to 250liter tha kuch Dino baad uska flow kum hota ja raha he kya problem ho sakti he model 4040 or sir membrane kaunsi Badiya hoti he Dow aur hydraunotics phone no 9628300006
@ariseagain3423
@ariseagain3423 6 жыл бұрын
Flow restrictor thoda bada lagao warna membrane kharab ho jayegi
@fareedmd8413
@fareedmd8413 4 жыл бұрын
100gpd membrane aur100gpd pump
@gulishtakhan978
@gulishtakhan978 6 жыл бұрын
Bhai Bhai saree video Hindi mein banaya karo
@palmarcolonche8212
@palmarcolonche8212 7 жыл бұрын
en español por favor o subtitulada
@palmarcolonche8212
@palmarcolonche8212 7 жыл бұрын
en español
function of flow restrictor and its relation with RO Membrane
5:18
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
RO mein Flow Restrictor Konsa Lagaye FR450 ya FR550
6:58
Reviewmaza
Рет қаралды 8 М.
Water Flow and Water Pressure: A Live Demonstration
5:41
Balkan Sewer & Water Main Service
Рет қаралды 91 М.
Replacing your Industrial RO Membrane: When and How to Do It
26:32
Water Purifier For Home | UNCOMFORTABLE TRUTH | Best Water Purifier 2024
22:55
Wirtz pumps are really clever
12:05
Steve Mould
Рет қаралды 15 МЛН
The Ancient City That Mastered Water
9:09
Primal Space
Рет қаралды 2,5 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН