SEE ALL VIDEOS - To view a list of all our LearnElectrics videos, click on the link below. There are many videos on many electrical topics including Installation, Part P, 18th Edition, Testing, Certification, Lighting, Sockets, Ring Circuits and much more. kzbin.info/door/YaJQnpO4XAp0yCgqzMkmfA
@MotherRussiaisforever3 жыл бұрын
Can you do a video on how to do install a socket outside may be in garden or just outside at the front door etc.
@Михаиллеви3 жыл бұрын
A basic subject that is often taught just as a procedure or drill without the student really understanding the reasoning behind the procedures. This explains all and better just with diagrams ! 👏
@learnelectrics44023 жыл бұрын
Thanks for the excellent feedback. That is exactly our method. Show you what you need to understand rather than just tell you the minimum. Thanks again. Dave
@danielteyehuago163311 ай бұрын
Wow! This is video very informative and the best tutorial on the topic for me so far. I really appreciate it. Thanks for sharing it with us.
@learnelectrics440211 ай бұрын
My pleasure Daniel.
@rizgar8121 Жыл бұрын
Thank you Dear for all this help.
@learnelectrics4402 Жыл бұрын
You're most welcome, thanks for watching.
@chrischaralambous2862 жыл бұрын
Another excellent video Dave. Thank you again for the clear explanation.👌 I am now well and truly hooked on your channel.👍
@learnelectrics44022 жыл бұрын
That's what we like to hear Chris. Thanks for watching. Dave.
@michaelcostello6991 Жыл бұрын
Can you do video of safe isolation of alternate supllies eg solar, wind, battery, engine. Risk asessments and safe work method statements ?
@learnelectrics4402 Жыл бұрын
It's now on the list to be done. Thanks.
@michaelcostello6991 Жыл бұрын
Thanks. This could cover transfer switches automatic and manual, Main switches marking and grouping, etc etc etc
@gbelectricks3 жыл бұрын
Great video Dave, one question that has always remained a mystery, is why isn’t disconnecting live and neutral, and making the ends safe inside the consumer unit, considered an approved method of isolation? Surely a physically disconnected circuit is safer than a locked off one? 🤷♂️
@learnelectrics44023 жыл бұрын
You are totally right. The IET approved method though is to leave the wires in situ. Personally, I always took the phase out of the MCB and neutral out of the neutral bar. That way, whatever happened at the MCB would not affect me. Leave the earth in the earth bar for the insulation resistance tests. Good stuff. Dave.
@ramzg54023 жыл бұрын
Thanks a lot Sir
@learnelectrics44023 жыл бұрын
Thank you Ramzi. Dave.
@tonyp28783 жыл бұрын
Thank you as always !
@learnelectrics44023 жыл бұрын
Thank you Tony. Thanks for watching. Dave.
@ifyougetstucklookitup2373 жыл бұрын
Thank you Dave. Appreciate the quality and content of the video.
@learnelectrics44023 жыл бұрын
Thanks for watching. Appreciated comments. Dave
@paborlouise3193 жыл бұрын
Thanks a lot for all your clips. Pls can you do a tut on how to select the right distribution board depending on the electrical load, overheating, etc ?
@learnelectrics44023 жыл бұрын
We could do Pabor, but it all comes down to you on site. How many circuits and what is the loading. Thanks for the request, appreciated. Dave.
@paborlouise3193 жыл бұрын
@@learnelectrics4402 3phase main breaker(switch) 42 circuit breakers, 100amps load. What I really what to know is what really determines the panel to be used?
@learnelectrics44023 жыл бұрын
That's only an average of 2 amps per breaker. the panel must be able to take at least 42 breakers. Everything else can be bought to fit into it, but if the cabinet only takes 30 breakers, well, that's a problem. Consider a 48 way cabinet or split it into 2 x 100A 24 way boards.
@paborlouise3193 жыл бұрын
@@learnelectrics4402 alright, thanks a lot.
@michaelcostello69912 жыл бұрын
At 4:38 you say for reverse polarity L-E is 0 volts. This should be 230 volts. I mean the load is live with neutral switch open. The load is live on each side with no current flowing ? Please confirm if what i say is correct. Thanks for excellent video discussing isolation. Especially the the safety when using double pole switch.
@learnelectrics44022 жыл бұрын
The video is correct. Follow the route of the electric from the supply transformer.
@ursulanield97673 жыл бұрын
Hello Dave thanks for the video. I had a question, are there instances when we have to isolate the whole board and not just the final circuit that we are working on?
@learnelectrics44023 жыл бұрын
Yes of course there are. In fact I have sometimes isolated the whole board when the inside is "messy". Changing MCBs, carrying out an inspection and test on the premises. If you are happier isolating the whole board then do it, after all it's your hands that you are putting inside. The safer the better.
@teyronnewreality3 жыл бұрын
Best video ever
@learnelectrics44023 жыл бұрын
Appreciate your comment, great. Thanks for watching. Dave.
@pauljohncross2 жыл бұрын
In your diagrams, you demonstrate the safe isolation of a single circuit by switching off the associated MCB. However, if the circuit neutral remains connected to the neutral bar and the neutral is then cut, would a neutral-earth fault then result, causing the RCD to trip?
@learnelectrics44022 жыл бұрын
Yes, that sometimes happens Paul. Makes me jump out f my skin. I would often remove phase and neutral when isolating, but we have to show you the way that the book shows for assessments etc. Good point and thanks for watching. Dave.
@pauljohncross2 жыл бұрын
BTW, great content, even for those who've been working in the trade for a number of years
@Mr.Therapist13 жыл бұрын
In your sequence you are not saying when you are switching off the MCBs and the main switch, you should say when that is done! Where is it? INNIT?